Inductive sensor NI10-M18-Y1X-H1141



Similar documents
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Inductive slot sensor

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Control- and feedback head for integrated mounting on Robolux valves Type 2036

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Inductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing

Magnetic proximity switches

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Electronic Pressure Switch EDS 300

Solenoid Valve Island Type 3965

Series 8146/5-V37 and Series 8150/5-V37

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Plastic tube flowmeters Series PT/PS

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Cable Plug acc. to DIN EN , Form A

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Use A Flowmeter

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Relative pressure transmitter type 520

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Givare NC-SRS 280 och 880

RY2 miniature industrial relays

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

SEISMIC VELOCITY TRANSDUCER T1-40

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Inductive sensors. Compact, fast, reliable. Edition 2013

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Digital input modules

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

BL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI

2.12. page Products for Explosion hazardous Environment

Digital display DA 48

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Capacitive Prox E2K-X

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Inductive Proximity Sensors

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Connection technology from ifm.

SAFETY MANUAL SIL Switch Amplifier

Safety Manual BT50(T) Safety relay / Expansion relay

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Conductive Level Switch FK 2 Technical Data:

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Flow switches Series AD/VH

Electric Rotary Actuator - On/Off or programmable control actuator

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Differential-Hall-Effect based Sensors Series A5S Overview

Control and Distribution Boxes made of Stainless Steel Series 8150

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Linear Luminaire with LED Series EXLUX 6402/2

Mobile data carrier TW-L80-50-P-B128

Sense it! Connect it! Bus it! Solve it! EncoderS

A good connection. International approvals.

3/2-way Solenoid Valve, direct-acting, NC or NO

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Three-phase monitoring relay CM-PFE

Fast, reliable, ultra-precise. My-Com precision switches.

Plug and Socket Devices CES 63 A Series 8579

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Contents. Document information

NX safety stand-alone

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Transcription:

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12 x 1 male connector Wiring Diagram Type code Ident no. 40153 Rated switching distance Sn 10 mm Mounting conditions non-flush Assured switching distance ð (0,81 x Sn) mm Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeatability ð 2 % of full scale Temperature drift ð ± 10 % Hysteresis 1 10 % Ambient temperature -25 +70 C Output function Switching frequency Voltage Non-actuated current consumption Actuated current consumption 2-wire, NAMUR 0.5 khz Nom. 8.2 VDC ï 2.1 ma ð 1.2 ma Functional principle Inductive sensors detect metal objects contactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil. Approval acc. to KEMA 02 ATEX 1090X Internal capacitance (C i) / inductance (L i) 150 nf / 150 µh Device designation É II 1 G Ex ia IIC T6 Ga/II 1 D Ex ia IIIC T115 C Da (max. U i = 20 V, I i = 20 ma, P i = 200 mw) Construction Threaded barrel, M18 x 1 Dimensions 52 mm Housing material Metal, CuZn, chrome-plated Active area material Plastic, PBT Max. tightening torque housing nut 25 Nm Connection Flange connector, M12 x 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Switching state LED yellow 1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Distance D Distance W Distance T Distance S Distance G Distance N 3 x B 3 x Sn 3 x B 1.5 x B 6 x Sn 2 x Sn Diameter of the active area B Ø 18 mm 2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories IMC-Di-22Ex-PNO/24VDC 7560003 2-channel isolating switching amplifier with M12x1 males, for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia, PNP transistor output NO IM1-22EX-R 7541231 Isolating switching amplifier, 2-channel; 2 relay outputs; input NAMUR signal; selectable ON/OFF mode for wire-break and short-circuit monitoring; adjustable output mode (NO / NC mode); removable terminal blocks; width 18 mm; universal power supply unit BST-18B 6947214 Fixing clamp for threaded barrel devices, with dead-stop; material: PA6 QM-18 6945102 Quick-mount bracket with dead-stop; material: Chrome-plated brass Male thread M24 x 1.5. Note: The switching distance of proximity switches can be reduced by the use of quick-mount brackets. MW-18 6945004 Mounting bracket for threaded barrel devices; material: Stainless steel A2 1.4301 (AISI 304) 3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories BSS-18 6901320 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene Wiring accessories RKC4.221T-2/TEB 6628420 Connection cable, female M12, straight, 2-pin, cable length: 2 m, sheath material: PVC, black; culus approval; other cable lengths and qualities available, see www.turck.com 4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and É II 1 D Ex ia IIIC T115 C Da acc. to EN60079-0 Local admissible ambient temperature ATEX category II 2 G electrical equipment -40 +70 C, category II 1 D -25 +70 C. The corresponding temperature classes are provided in the ATEX type-examination certificate. Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits compliant to EN60079-0 and -11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). When employed in safety systems to IEC 51408 it is required to assess the failure probability (PFD) of the complete circuitry. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com