Schedule of Quantities



Similar documents
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

NATIONAL INSTITUTE OF BIOLOGICALS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL.

BOQ for Plumbing, Sanitary Works

BILL OF QUANTITIES FOR CIVIL WORKS FOR 8MW POWER PLANT

Tender schedule. Rate in

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Department of Industrial and Systems Engineering Indian Institute of Technology, Kharagpur TENDERNOTICEON TURN KEYBASIS

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

CHAPTER NO. 27 QUANTITIES OF MATERIALS

CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP)

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: -

LAYING BLOCK AND BRICK

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY

PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

How To Run A Test Lab In Rourkela

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

PART 1 GENERAL 1.1 SECTION INCLUDES

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

STATE BANK OF INDIA.

INSTALLATION OF A BAY WINDOW

DENVER MODEL 30 X 30 SPECIFICATIONS

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

12.1 Schlüter -KERDI-BOARD

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete

Chapter. Restoration of Damaged Structures

HOPLEYS OPENWEBSTEELJOISTS

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

PUBLIC RESTROOMS, DESIGN INTENT

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Preformed Metal Roofing and Siding

BILL OF QUANTITIES Part No.: Part Description

ATLANTA MODEL SPECIFICATIONS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Window Installation Instructions

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

CLEAR-DIVISIONS APERTO

800 Communications Circuits

Linkeo 19" freestanding cabinets

Rooflight INSTALLATION INSTRUCTIONS

Installation Window Building In Details

TARIFF CODE and updates standard

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

Important Information for Installer & Homeowner

March 14, Installation of Bay, Bow and Garden Windows

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

Chapter 10 - Scaffolding Systems

IF YOU NEED A POLE BARN OR DIY KIT CALL NOW AND LETS MAKE A DEAL

Holz Choices & Specifications

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Mark Cramer Inspection Services, Inc.

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Triarch Products Over Various Interior Substrates

MRI RF SHIELDING DESIGN

Sports Buildings: budget costs for the Flood Relief Fund

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

CLEAR-DIVISIONS CENTERFOLD

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

FIRE RATED GLAZING System Guide

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

Data Centre Solutions

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Solicitation DTFACN-11-R Attachment #9

ICRC WORK SPECIFICATIONS IRAQ WATER AND HABITAT

6. BILLS OF QUANTITIES

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT

Batibox TM flush-mounting boxes for dry partitions

Revised Specifications & Scale of Amenities for General Pool Residential Accommodation (Type I to VI) Revised Amenities.doc

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

Removable Aluminium posts

SECTION PIPE HANGERS AND SUPPORTS

GYPSUM BOARD AND PLASTER

Packaged Terminal Air Conditioner Wall Sleeve Installation

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Ver. 2. Guide to. Inspecting Residential Brick Veneer

LONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY

swimming pool accessories

Transcription:

CIVIL WORK (A) 1 Providing and fixing corrugated galvanised iron sheets of 20 B.W.G. for roofing with wind ties including fastening with galvanised iron screw and bolts and lead and bitumen washers as per drawing complete. (TATA CG I) 2 Providing, fabricating and erecting at site of work the tubular steel structure (shed) of standard size as per standard design and specifications having various spans ranging from 6 mt. to 18 mt. Length in between trusses and in multiples of standard length of bays as specified as per standard specifications inclusive of cost of steel tubular trusses, tubular columns, purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade complete Spec. No. : As directed by Engineer-in-charge. Schedule of Quantities sqm 113.40 MT 2.00 3 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in super structure including striking joints, racking out joints wateringand scaffolding complete. 4 Providing internal/external cement plaster 12 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surface in all positions including scaffolding and curing etc. complete. cum 13.00 sqm 282.00

5 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding. 6 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design. (Section weight of only steel members shall be measured for payment without weight of glass & other fittings) Kg 100.00 Kg 200.00

7 Providing and fixing suspended white/colour decorative ceiling of gypsum board which includes G.I. Perimeter channel ( MF6) of size 0.40 mm thick ( having one flange of 20 mm and another flange of 30 mm and web of 27 mm) along with perimeter of ceiling, screw fixed to brick wall / partition with the help of nylon sleeves and screws at 610 mm centers. Thereafter suspending G.I. intermediate channel ( MF 7) 600 mm. C/C of size 45mm (0.9 mm thick with two flanges of 15 mm each) from the soffit at 450 mm centre with connecting angle (ie ceiling angle) of width 25mm x 10mm x 0.40mm thick fixed to soffit with G.I.cleat and teel expansion fasteners. sqm 65.00 Celling sections ( MF 5 ) of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 450 mm centers. 12.5 mm tapered edge Gyp board (conforming to IS 2095-1982) is then screw fixed to celling section with dry wall screws at 230 mm centers. Screw fixing is to be done mechanically with suitable attachment. The boards are to be joined and finished so as to have flush look which includes filling and finishing the tappered & square edges of the boards with jointing compound, joint paper tape and appropriate suitable primer and three coats of plastic acrylic paint. The item includes for light fitting, grill diffuseres and cut out etc. have to be made with frame of perimeter channels of size 20mm x 30mm x0.55mm.thick supported suitable and angle bead is to be used at steps to get straight line finish etc. complete Spec.No. : As directed by Engineer- in-charge

8 Providing and laying cement concrete flooring 40 mm thick with 1:2:4 cement concrete laid to proper level and slope in alternate bays, including compacting, PVC/ Glass/Aluminum strips at joints, marking lines to give appearance of tiles of 30 cm x 30 cm or other size laid diagonally/square etc. finishing smooth(with extra cement) in any colour as directed and curing complete. sqm 65.00 9 EXTERIOR FINISHING Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm). sqm 141.00 10 INTERIOR FINISHING Application of J K White cement based J K Wall putty in 2 coats on old/new surface including removing of existing painted surface, cleaning of all loose particlea on the surface, washing of wall, prepare the surface for wall putty including one coat of primer. (including all labour charges) complet 11 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 12 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. sqm 206.00 cum 0.20 sqm 25.00 13 Any other item which is not covered under this schedule will be paid as per DSR 2007 if not than SOR-2011-2011 Nagpur CIVIL WORK (A) % above or below 10000.00 Total in Rs.

ELECTRICAL WORK (B) 14 Supplying of 1200 mm (48") ceiling fan of Bajaj, Orient,Khaitan, Usha or equivalent make complete with all accessories as required as per the direction of engineer in charge. 15 Supply of following lighting fixtures complete in all respect with lamps and necessary control gear including supply of all connected materials ceiling rose, clamps, supports, chains, anchors, fastners, bolts, nuts and washers etc. as required and as per direction of Engineer-in-charge. Each 6 a b Surface/Pendent Mounting Industrial T5 Luminaires with white powder CRCA sheet steel housing with reflector cover T5 channel luminaires of Bajaj,CG, or equivalent make. Outdoor lighting with CFL luminaries with Bulkhead fittings water proof of Bajaj/Khaitan/CG or equivalent make. 16 Supply and drawing of LAN cable in existing PVC conduit pipe with RJ-45 connector of D-link or equivalent make. 17 Window mounted with stand,desert cooler (approx. covering 3000 Cu.m)with multiple speed regulator and submursible pump with the approval of Engineer-in - charge. 18 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required. Nos. 10 Nos. 2 RMT 60 Nos. 2 a Group C Point 25

19 Wiring for twin control light point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable in surface/recessd PVC conduit, 2 way modular switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required. 20 Wiring for light/power plug with 2x4 sq. mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit alongwith 1 No. 4 sq. mm. FR PVC insulated copper conductor single core cable for loop earthing as required. 21 Wiring for light/power plug with 2x2.5 sq. mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit alongwith 1 No. 2.5 sq. mm. FR PVC insulated copper conductor single core cable for loop earthing as required. 22 Supplying and drawing following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed stell/ PVC conduit as required. Point 2 Metre 20 Metre 50 2 pair Metre 60 23 Supplying & fixing 25mm PVC conduit of ISI mark RMT. 90 alongwith accessories in recess including cutting the wall & making good the chases. 24 Supplying, fixing and commissioning of following way, three pole and neutral, sheet steel, MCB Distribution board, 415 volts on surface / Recess, complate with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconections phosphatised and powder painted including earthing etc. as required complete with RCCB & MCCB as under. a 4 Way, Single door, horizontal type. Each 1 b Incoming 1 x 25 Amp RCCB Each 1

c Outgoing 5 to 32 Amp single pole MCB for 1 DB. Each 5 25 Installation, testing and commissioning of pre-wired, Each 10 flourescent fitting/compact flourescent fitting of all types, complete with all accessories and tube etc. including connection with 1.5 sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. 26 Installation, testing & commissioning of Ceiling fan at different locations complete including wiring the down rods with 1.5 sq. mm. FR PVC insulated copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 27 Supply and fixing stepped type electronic fan regulator of Anchor (ROMA) or equivalent modular regulator with the approval of Engineer-In-Charge on the existing modular switch box including connections etc. as required. Each 6 Each 6 28 Supplying and fixing following modular switch/socket on the modular plate & switch box including connections with modular plate etc. as required of Anchor (ROMA) or equivalent make with the approval of Engineer-In-Charge. a 5/6 amps. Switch Each 25 b 2 way 5/6 amps. Switch Each 1 c 15/16 amps. Switch Each 2 d 3 Pin 5/6 amps. Socket outlet Each 7 e 6 Pin 15/16 amps. Socket outlet Each 2 f Telephone Socket outlet Each 1 MAINS AND SUB MAINS

29 Circuit/sub-main wiring in PVC conduit: Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. a 2 X 2.5 sqmm + 1 X 2.5 sq.mm earth wire RM 20 b 4 X 10 sqmm + 2 X 10 sq.mm earth wire ELECTRICAL WORK (B) Total quoted amount (Rs.), (A+B) RM 25 Total (in Rs) IN FIGURE (Rs) IN WORDS (Rs)