Martin Krus, Klaus Sedlbauer, Herbert Sinnesbichler

Similar documents
Frost Damage of Masonry Walls A hygrothermal Analysis by Computer Simulations

Long-Term Hygrothermal Performance of Green Roofs

Moisture Content in Insulated Basement Walls

Drying of brick walls after impregnation

Sustainable construction criteria to evaluate the thermal indoor climate - further development of the BNB assessment tool and practical implementation

Heating and Ventilation

A COMPARISON OF DIFFERENT MOULD PREDICTION MODELS. B-3001 Leuven, Belgium

Molds and mildew are fungi that grow

COMPARISON OF DIFFERENT HVAC SYSTEMS IN MULTI- STOREY APARTMENT BUILDINGS IN HELSINKI

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

A Roof Integrated Solar Heating System Without Storage

Crawl space heat and moisture behaviour

Moisture risk in prefabricated wooden wall elements (TES-elements) with a vapour retarder of OSB/3

National Building Code of Canada 2010

WUFI-ORNL/IBP A North American Hygrothermal Model

Outline of the joint research project of SWT, ZfS, ISFH and FhG-ISE: Analysis and evaluation of large thermal solar combi-systems

Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions

Passive house rehabilitation of post war residential building in Zug, Switzerland

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Basement Insulation: Best Practices for Efficient, Durable, & Healthy Homes

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Influence of Moisture Buffering Effects on the Risk of Mould Growth. Martin Krus

Home inspectors are not mold inspectors, however they do inspect for defects that

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Before You Start an Energy Efficiency Retrofit The Building Envelope

air conditioners how to choose a cooling system

How To Get A Passive House

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Field test of a novel combined solar thermal and heat pump system with an ice store

Wall Moisture Problems in Seattle

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

Service & Maintenance:

Roof Insulation Building. Energy. Environment friendly e-library

White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014

Housing Fact Sheets. Moisture Condensation at the Windows

Energy savings in the residential area are essential in

THERMAL STORAGE WITH PCM VS. THERMAL INSULATION IN WARM AND HOT CLIMATES

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

All the best brands all under one roof

THE IMPORTANCE OF EXTERNAL WALLS IN ENERGY EFFICIENCY OF BUILDINGS

Completion of the Technology and Innovation Center

Old Dominion University Mold Management Plan

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

Liabilities of Vented Crawl Spaces, Their Impacts on Indoor Air Quality in Southeastern U.S. Homes and One Intervention Strategy

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

New technical solutions for energy efficient buildings

Best Practices for Crawl Space Insulation

Technical Series

New Trends in the Field of Automobile Air Conditioning

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Field Performance of Different Interior Basement Insulation Systems

CRAWLSPACE ISSUES IN THE NORTHWEST

CONDENSATION EXPLAINED

ROOFS, SNOW AND ICE DAMS

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

CONDENSATION - THE BASICS

The Fallacies of Venting Crawl Spaces January 3, 2002 Craig DeWitt, PhD, PE

Energy efficient windows, doors and conservatories. Make a better choice

CONDENSATION. Section Break (Next Page)

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

Material test chamber with mechanical convection

Environmental Data Center Management and Monitoring

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Renovating Your Basement

Preventing Ice Dams on Roofs

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

Lesson 36 Selection Of Air Conditioning Systems

Technology: Heating, Ventilation and Air Condition (HVAC) Zone Controls

Energy Concept and Technology in the Rosenheim Solar Decathlon House

CFD AND MULTI-ZONE MODELLING OF FOG FORMATION RISK IN A NATURALLY VENTILATED INDUSTRIAL BUILDING

European technical approval

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

WHOLE-HOUSE VENTILATION SYSTEMS

Description and Syllabus of the international, modular Wood Building & Construction Course

Performance of 8 Passive House Envelopes in Cold Climates

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

State of the Art Energy Efficient Data Centre Air Conditioning

Module 3.7. Thermal bridging

Performance Testing of Solar Combisytems

BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS. Wagdy Anis, FAIA, LEED ap*

RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption

Moisture-Safe Unvented Wood Roof Systems

Energy Efficiency HOSPITALITY.

ENHANCED LABORATORY HVAC SYSTEM

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

Signs of insulation problems In the winter. In the summer. conditioning system

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Glossary of Heating, Ventilation and Air Conditioning Terms

Transcription:

Martin Krus, Klaus Sedlbauer, Herbert Sinnesbichler Artificial thermal bridge with a dew point switch to accomplish an appropriate control of the ventilation for the prevention of mould growth in buildings Fraunhofer-Institute of Building Physics, Valley/Oberlaindern, Germany Abstract The well known problem of global warming due to the green house effect has provoked the Kyoto Protocol, which first of all means energy saving. In colder regions the highest amount of energy is consumed by the heating of buildings. Beside a better insulation the diminishment of ventilation losses is a common way for saving energy. Unfortunately this increases the risk of mould growth, which is determined by the temperature and relative humidity of the inner wall surface. An appropriate ventilation system has to prevent surface conditions suited for mould. For energy saving purposes permanent ventilation is no solution. Instead the ventilation has to take place subjected to unsteady humidification processes like cooking or bathing. The measurement of surface temperature and humidity to control the ventilation is too expensive and needs continuous maintenance. Instead the proposed innovative control system uses a thermal bridge, designed in such a way, that there dew water occurs just at the same time, when in problematic areas like corners conditions for mould are reached. The thermal bridge is equipped with a dew sensor switching the ventilator. Just when condensation has stopped and the surface of this sensor has dried the ventilator will be deactivated. This ensures that the ventilation occurs only when required. Additional advantages are the simplicity and cheapness of this system combined with the lack of necessary service. Keywords: Prevention of mould, ventilation control, dew point switch 1 Introduction The growth of mould is frequently observed after carrying out energy-saving renovation measures in existing buildings (i.e. installation of air-tight windows) due to traditional but now insufficient way of airing the rooms (see figure 1). Mould growth on the interior surfaces of external component parts may be a risk to the health of the occupants. It is possible to avoid fungal decay in rooms for a certain period of time by using biocides or similar agents, yet health risks caused by these products cannot be excluded. Temperature and humidity are the decisive factors to allow the growth of mould. Figure 2 shows the life cycle of mould fungi. However, indoor air temperature and humidity are not decisive for the risk of mould growth, but the hygrothermal boundary conditions on the internal wall surface. It is important to know that mould growth doesn t need condensed water.

Depending on the temperature mould growth may start already at surface moistures of approximately 75 % relative humidity. Figure 1 Here an adequate ventilation is only possible by drafty windows or by means of additional ventilation equipment Figure 2 Life cycle of mould fungus Consequently, an adequate ventilation system which is to prevent the growth of mould, must ensure that these boundary conditions on surfaces do not occur, at least not for longer periods. An enforced permanent ventilation is not

acceptable from the energetic point of view. Ventilation must occur depending on the boundary conditions on the surfaces caused primarily by transient moisturising processes (cooking, showering etc.). But permanently measuring the surface moisture and surface temperature is hardly justifiable the complexity and costs. Therefore, in most cases, ventilation systems are controlled only by air quality (CO 2 concentration) at present, whereas moisture load and the risk of mould growth remain unconsidered. 2 Development concept The novel concept described here is to install an artificial thermal bridge at selected positions of an external wall. By means of innovative modelling programmes (WUFI ([1], [2])), Hygrothermal Room Model [3], Biohygrothermal Method for Assessing the Risk of Mould Growth [4], [5], which were developed at the Institute of Building Physics (IBP), this "thermal bridge" can be thermally designed in a way that condensed water is formed there as soon as the surface moisture on the interior surface of an external wall in problematic areas (i.e. corners) has just reached a value to allow mould growth. Figure 3 shows a draft of the simple design of such an artificial "thermal bridge". Figure 3 Schematic design of an artificial "thermal bridge" with dew point switch If simple switching dew point switches are installed on the internal surface of this artificial "thermal bridge" (design for example as shown in figure 4, but also simple resistive sensors or similar equipment), ventilation systems can be activated this way as long as dewing conditions exist. As soon as dewing conditions cease, the ventilation system will be switched off automatically, since it is no longer needed.

Figure 4 Schematic design of a dew point switch to control ventilation The advantage of using a dew point switch is that the ventilation will be switched on only if the external air temperature is below the internal air temperature, conforming with the principles of building physics. The ventilation system is running only when the indoor humidity is high and the temperature of the interior wall is so much lower than the indoor air temperature that the moisture on the interior surfaces will be too high. Thus, unnecessary or even harmful ventilation is almost impossible. The significant advantage of applying this kind of dew point switch is that it works without any additional measurement equipment. It is cheap and virtually maintenancefree, and regular calibration measures are unnecessary. 3 Prospects The patent for the described development concept has already been granted [6]. In the near future it is intended to design a model, consisting of a dew point switch and a suitable ventilation system to test practical feasibility. It is planned to use standard equipment to the greatest possible extent. The model will be tested in the laboratory in a climate chamber under different boundary conditions at first. Then the results will be used to optimise the design. Later, outdoor testing will be carried out at test houses. The outdoor testing site of the IBP has two buildings, identical in construction ("twin houses"), where the operability of the newly developed system can be tested under realistic conditions as well as its advantages in comparison to conventional solutions. These tests should be carried out during at least one heating period. For this reason, it would be desirable to start the examinations in late autumn to be able to test the most interesting period, namely the cold winter months, from the very beginning.

4 References [1] Künzel H.M. 1995. Simultaneous Heat and Moisture Transport in Building Components. - One- and two-dimensional calculation using simple parameters. IRB Verlag Stuttgart (1995), pp 1-154, ISBN 3-8167-4103-7. [2] Krus, M.: Moisture Transport and Storage Coefficients of Porous Mineral Building Materials. Theoretical Principles and New Test Methods. IRB-Verlag Stuttgart (1996),pp 1-172, ISBN 3-8167-4535-0. [3] Holm, A.; Sedlbauer, K.; Künzel, H.M.; Radon, J.: Berechnung des hygrothermischen Verhaltens von Räumen Einfluss des Lüftungsverhaltens auf die Raumluftfeuchte (Calculation of the hygrothermal behaviour of rooms Influence of the ways of airing on the relative humidity of the room). Tagungsbeitrag für das 11. Bauklimatische Symposium der TU Dresden. 26. 30. Sep. 2002, Dresden, pp 562 575. [4] Sedlbauer, K.: Beurteilung von Schimmelpilzbildung auf und in Bauteilen (Assessment of mould growth on and in building components). Thesis University of Stuttgart (2001). [5] Sedlbauer, K; Krus, M; Zillig, W.: Vorhersagemodell zur Schimmelpilzbildung bei Wechselklima Praktische Beispiele. Tagungsbeitrag zum Architekten- und Ingenieurtag zum Thema Bauphysik im Holzbau (A new model for mould prediction for transient ambient conditions - Practical Examples). 27. Apr. 2002, Nürnberg, pp 43-55. [6] Sedlbauer, K; Krus, M; Sinnesbichler, H.: Verfahren und Vorrichtung zur Vermeidung von Schimmelpilzbefall (Method and device for the prevention of mould growth). Patent Nr. DE10321253, 7. Mai 2003.