1 WUFI-ORNL/IBP A North American Hygrothermal Model Achilles Karagiozis, Ph.D. Hartwig Künzel Andreas Holm ABSTRACT Building envelope designers and architects provide expert advice during the selection of building envelope systems. Until recently, a limited hygrothermal engineering analysis was performed to determine performance of a selected wall system other than review the details of wall systems and subsystems. Infrequently, a glaser or dew point method analysis may have also been performed, but this kind of analysis is only steady state in nature and ignores the hygroscopic effects, such as nonlinear dependencies of hygroscopic material properties, moisture storage, freeze-thawing mechanisms, liquid transport, latent heat, and transient nature of moisture loads at the boundaries. The main reason for not performing a thorough moisture engineering analysis was the lack of an easy-to-use hygrothermal model that integrated the physics and that was accompanied by a material property database and a set of realistic hygrothermal environmental loads for both the interior and exterior of the envelope. Recently, the increasing demand for better performing calculation methods to assess the moisture behavior of building components prompted an international collaboration between the Oak Ridge National Laboratory (USA) and the Fraunhofer Institute in Bauphysics (Germany) to develop a hygrothermal design tool named WUFI-ORNL/IBP. This hygrothermal design model can assess the response of building envelope systems in terms of heat and moisture loads and can also provide a very useful and fair method for evaluating and optimizing building envelope designs. This state-of-the-art model is discussed in detail in this paper and is also available in North America free of charge at INTRODUCTION In civil and architectural engineering, there is an increasing demand for calculative methods to assess and predict the long-term heat, air, and moisture (hygrothermal) performance of building envelope systems. Assessing the particular performance of a complete envelope system or a subsystem is a critical task for an architect or building envelope designer. This need for better tools to assess the hygrothermal performance of designed systems has been necessitated by numerous catastrophic moisture-related failures, by codes, and by higher expectations and demands by the consumer. Indeed, even today the majority of the building envelope designs rarely undergo a design assessment for moisture control; instead, prescriptive requirements are sometimes followed that occasionally apply. Until very recently, even if a North American building envelope designer applied a moisture design assessment approach, such as the one recommended by ASHRAE, the analysis was steady state (stagnant environmental loads) and did not account for the important dynamic and thermal and moisture transport mechanisms. However, recent advancements by Künzel (1995), Salonvaara and Karagiozis (1998), Karagiozis (1997, 2000), and IEA Annex 24, reported in Hens (1996), in fundamental understanding of combined heat, air, and moisture transport have aided in the development of advanced hygrothermal computer models. Several advanced models have been developed and detailed reviews of these are included in a new chapter in the ASTM manual, Moisture Analysis and Condensation Control in Building Envelopes (Karagiozis 2001). At present, only a limited number of these models have been termed as moisture engineering models. Karagiozis Achilles is senior research engineer and hygrothermal project manager at Oak Ridge National Laboratory, Oak Ridge, Tenn. Künzel Hartwig is director of hygrothermics and Holm Andreas is senior researcher and hygrothermal modeling manager, Fraunhofer Institute of Building Physics, Holzkirchen, Germany. Buildings VIII/Moisture Model Inputs Principles 1
2 Essentially, moisture engineering models deal with the characterization of the complex hygrothermal behavior of building envelope systems. The service life of a building envelope is strongly correlated with how the individual systems of building envelope components (walls, roofs, and basements) manage their responses to heat, air, and moisture transport excitations. The main advantage of modeling is that, if the building envelope system has been carefully characterized, the long-term hygrothermal performance of the system under different climatic conditions, effect of changes in the interior conditions (HVAC), and the effect of various energy retrofits to the building durability (hygrothermal performance) can be predicted. Moisture load tolerances of various envelope designs can also be investigated with respect to the drying potential and the total system effect of various design alternatives by employing modeling. Modeling, however, is not meant to replace valuable lab and field investigations but, rather, to challenge them and extend the information they may provide. In many experimental evaluations of complex envelope systems, simulations can be performed to design, explain, and interpret the experimental results. Over the last 40 years, moisture engineering heavily relied on experimental approaches to resolve moisture performances of building envelopes. Hundreds of research investigations employing laboratory and field monitoring have been performed in both North America and Europe on specific building envelope case studies (Hens 1996; Trechsel 1994). A disproportionate number of these have only concentrated on the thermal performance characterization of building systems. However, the majority of our current design guidelines have essentially been generated by past experimental analysis. This has provided invaluable results in some case, but more questions than answers in others. During the same period (1960 to 1990), moisture modeling of building envelope systems was not developed to the same level of expertise as that provided by experimental approaches. A review of the state-of-the-art model by Karagiozis (1997) stated, Sophisticated hygrothermal models have not yet been available to building envelope designers, as they are mainly research models. As the shift of regulatory design code (NBCC) approaches from the limited prescriptive design to performance and objective based building envelope codes is being adopted, the demand for design assessment and performance models will increase many-fold. Scaled down versions of these sophisticated moisture modeling tools will eventually be distributed to building envelope designers. This North American gap has been recently bridged by the development of the WUFI-ORNL/IBP hygrothermal model. In this paper, a brief description of that model is given. BACKGROUND ON WUFI-ORNL/IBP The WUFI-ORNL/IBP hygrothermal model is an operating-system-based personal computer program for the hygrothermal (heat and moisture) analysis of building envelope constructions. WUFI-ORNL/IBP is an advanced hygrothermal model that was specifically tailored to the needs of architects and building envelope designers. The software is an easy-to-use, menu-driven program for use on a personal computer that can provide customized solutions to moisture engineering and damage assessment problems for various building envelope systems. The model was jointly developed by the Fraunhofer Institute for Building Physics (IBP) in Holzkirchen, Germany, and Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, USA, both internationally established in the area of building energy performance and durability assessments. The joint effort of these two laboratories has created easy-to-use and intuitively accessible building moisture engineering software on the market. This model is also an educational tool for both the experienced and the novice user, building envelope design engineer, and architect. This advanced model has been described in detail in a new ASTM handbook, Moisture Analysis and Condensation Control in Building Envelopes, MNL 40 (Trechsel 2001). The model is a transient, one-dimensional heat and moisture transfer model that can be used to assess the hygrothermal behavior of a wide range of building material classes under climatic conditions found in North America. This version of the model was specifically developed to provide an educational overview of the complicated moisture transport phenomena occurring in construction assemblies and to allow both building envelope designers and architects insight into design decisions. The model can be used to estimate the drying times of masonry, solid concrete, and lightweight structures with trapped or concealed construction moisture; investigate the danger of interstitial condensation; or study the influence of driving rain on exterior building components. The program can also help to select repair and retrofit strategies with respect to the hygrothermal response of a particular wall assembly subjected to various climates. This allows the comparison and ranking of different designs with respect to total hygrothermal performance. This design tool can aid in the development and optimization of innovative building materials and components. For example, WUFI simulations led to the development of the smart vapor retarder (Künzel 1998), a successful application of a software tool to a practical moisture control problem. Once the user supplies the model with the data it needs, it will calculate the time evolution of the temperature and moisture fields in the building component. During or at the end of the simulation, you will be given three types of distribution results that describe the temporal evolution of certain quantities taken at specified locations or as mean values over specified layers. 2 Buildings VIII/Moisture Model Inputs Principles
3 Figure 1 Film display of the cross section distributions of temperature, relative humidity, and moisture content and heat and moisture fluxes. The following parameters are given as courses: the heat flux densities through the interior and exterior surface, respectively; the temperature and relative humidity at monitoring positions of your choice (e.g., at the interior and exterior surfaces or in the middle of an insulation layer); and the mean moisture content of each material and the total moisture content of the entire building component. Additionally, the following profiles (graphs), which show the spatial distribution of a quantity across the building component at a specified point in time of the following quantities, are available: the temperature across the assembly, the relative humidity across the assembly, and the moisture content across the assembly. A film file, which contains the transient profiles over all time steps, allows the display of the thermal and hygric processes in the building component as an animation. Figure 1 shows an example of a film file displayed as the model performs a simulation. A recently added feature is the way the moisture and thermal fluxes are displayed at the interface of each material interface. Courses, profiles, and the film are written to a single file in a compact binary format. This file is currently imbedded in the input file to allow better control of each simulation case. The model offers graphics functions that allow you to view the computed courses and profiles and print them. The film viewer allows you to view the film at your leisure after completion of the calculation. The predecessor of this program, WUFI, was released in Europe in 1994 (Künzel 1995) and has since been widely used by building envelope designers, architects, building physicists, consulting specialists, and universities in Europe. The WUFI-ORNL/IBP model is an educational tool for understanding the basic principles and interactions present during moisture transport. Physical Background The WUFI-ORNL/IBP model is a heat and moisture transport model that is customized for predicting the performance of building envelope systems in North and South America. In this section of the paper, some of the fundamental equations used in the main WUFI engine by Künzel (1995) are discussed. For more details on the theory, consult the corresponding chapter 40 in the new ASTM manual, Moisture Analysis and Condensation Control in Building Envelopes (Künzel et al. 2001). Buildings VIII/Moisture Model Inputs Principles 3
4 Moisture Storage The application of hygrothermal simulation tools requires some basic knowledge about material properties. Most building materials are hygroscopic, which means that they absorb water vapor from the environment until equilibrium conditions are achieved. This behavior can be described by sorption curves over a humidity range between 0% and 95% RH. For some materials, the equilibrium water content is not very sensitive to changes in temperature these sorption curves are also called sorption isotherms. The capillary water range stretches from 95% RH up to capillary saturation at 100% RH. In this range, the equilibrium water content of a material is still a function of relative humidity. However, this function can no longer be determined by sorption tests in climatic chambers. Here, a pressure plate apparatus is necessary in order to complete the sorption curve in the high humidity range. The resulting water retention curve is a prerequisite for simulations including liquid transport. Figure 2 shows some examples of these curves for typical building materials with different sorption capacities. While wood has a similar moisture capacity in both humidity ranges, clay brick has a very low sorption capacity in the hygroscopic range but high water retention in the capillary water range. For concrete, the opposite is true. These differences have an important effect on the transient moisture behavior of the materials and may not be neglected. The hysteresis between absorption and desorption isotherms is usually not very pronounced this is approximated in the model as the absorption isotherm. Figure 2 Moisture retention curve for three typical building materials. Shaded area is the part the capillary water range determined with pressure plate apparatus. Moisture Transport The moisture transport in porous materials is largely due to vapor diffusion, surface diffusion, and capillary conduction. The coincidence of these transport phenomena in practice will be explained by Figure 3. Considered is a capillary in a masonry wall under winter conditions when the vapor pressure indoors is higher than outdoors and the inverse is true for the relative humidity. In the dry state, the vapor is driven outward by the vapor pressure gradient. However, such a dry state rarely exists and there is a layer of absorbed water at the inner surface of the pore. This layer has a higher molecular density (it is thicker ) at the outdoor end compared to the indoor end of the capillary due to the gradient in relative humidity that is opposed to the vapor pressure gradient. By molecular motion in the surface, film moisture is thus transported inward. Vapor and surface diffusion can counterbalance each other to such an extent that the overall moisture transport and, therefore, the amount of condensation are Figure 3 Moisture transport mechanism. 4 Buildings VIII/Moisture Model Inputs Principles
5 considerably reduced. In the case of wet conditions (e.g., after rain penetration), when the pores are filled with water, capillary conduction sets in. This very efficient moisture transport is governed by differences in capillary pressure. Since there is a direct relation between the capillary pressure and the relative humidity (Kelvin s law), the latter can also be considered as a driving force for capillary flow. Governing Transport Equations The governing equations employed in the model for mass and energy transfer are as follows: Moisture transfer w φ Energy transfer H T φ = ( D t φ φ + δ p ( φp sat )) T = ( k T) + h t v ( δ p φp ( sat )) where c = specific heat, J/kgK D φ = liquid conduction coefficient, kg/ms H = total enthalpy, J/m³ h v = latent heat of phase change, J/kg k = thermal conductivity, W/(mK) p sat = saturation vapor pressure, Pa t = time, s T = temperature, K w = moisture content, kg/m³ δ p = vapor permeability, kg/(mspa) φ = relative humidity The storage terms are on the left-hand side of Equations 1 and 2. The fluxes on the right-hand side in both equations are influenced by heat as well as moisture the conductive heat flux and the enthalpy flux by vapor diffusion with phase changes in the energy equation strongly depend on the moisture fields and fluxes. The liquid flux in the moisture transport equation is only slightly influenced by the temperature effect on the liquid viscosity and, consequently, on D φ. The vapor flux, however, is simultaneously governed by the temperature and the moisture field because of the exponential changes in the saturation vapor pressure with temperature. Due to this close coupling and the strong nonlinearity of both transport equations, a stable and efficient numerical solver had to be designed for their solution. Material Properties and Boundary Conditions The accuracy of simulation results depends largely on the availability of consistent material properties. The lack of reliable material data has been the main handicap for the largescale application of modern simulation tools. Therefore, a temporary educational North American material property (1) database (ASHRAE 2000) is included in the program. The minimum parameters required for each material are specific heat capacity c, thermal conductivity λ, bulk density ρ, total porosity ε, and the vapor diffusion resistance factor µ. If hygroscopicity and capillarity should be accounted for, the moisture retention curve (see Figure 2) and the liquid conductivity D φ have to be added. All building components interact with their hygrothermal environment. This means that the ambient conditions influence the building component and vice versa. This reciprocal influence, which is mainly confined to the interior environment, may have to be considered for the formulation of the boundary conditions. For most applications, an annual sine wave for indoor temperature and humidity is appropriate. The formulation of the exterior climatic conditions is more complex. If solar radiation or precipitation should be accounted for, hourly weather data become necessary. A complete data set (including precipitation) for more then 50 North American locations is included in the model. Bill Seaton from ASHRAE is gratefully acknowledged for his assistance. Calculation Procedure The transient calculation procedure of the model is outlined by the flow chart in Figure 4. The necessary input data include the composition of the examined building component, its orientation, and inclination, as well as the initial conditions and the time period of interest. The material parameters and the climatic conditions can be selected from the attached database. Starting from the initial temperature and water content distributions in the component, the moisture and energy balance equations have to be solved for all time steps of the calculation period. Both equations contain the storage terms on the left and the transport terms on the right-hand side. The moisture balance includes the derivative of the moisture retention curve (l.h.s.), the liquid transport and the vapor diffusion, which are related to gradients in relative humidity and vapor pressure, respectively. The enthalpy of solid and moisture forms the storage of the energy balance. The energy flux consists of the thermal transmittance and the latent heat due to condensation and evaporation of moisture. The coupled transfer equations are solved numerically by an implicit finite volume scheme. The resulting output contains the calculated moisture and temperature distributions and the related fluxes for each time step. The results may be presented as animated moisture and temperature profiles over the cross section of the building component or as plots of the temporal evolution of the variables. WUFI-ORNL/IBP HYGROTHERMAL MODEL FEATURES The model is one of the most advanced hygrothermal models for building envelope analysis for architects, engineers, and consultants. It is based on a state-of-the-art understanding of building physics with regard to sorption and Buildings VIII/Moisture Model Inputs Principles 5
6 Figure 4 Flow chart of WUFI-ORNL/IBP. suction isotherms, vapor diffusion, liquid transport, and phase changes. The model is also well documented and has been validated by many comparisons between calculated and field performance data (Künzel et al. 1995; Künzel and Keiβl 1996; Holm and Künzel 1999). The model requires a limited number of standard, readily available material properties. A materials database that is part of the program includes a full range of materials commonly used in North America. At present, existing data are used from ASHRAE and other sources, but these will be upgraded to complete material properties at Oak Ridge in the near future. This database will also be published on the Internet and registered users can download it for free. As material properties that pass the high-quality assurance required to be included in the database are not readily available, this is a limitation for all hygrothermal models. The model requires hourly weather data, such as temperature, relative humidity, wind speed and orientation, driving rain, and solar radiation, which are employed in the hygrothermal calculations. These data are available for a wide range of North American climatic zones The model has several enhanced features. Some attractive modeling capabilities are as follows: The model is an excellent educational tool for understanding the complex interactions during the transport of heat and moisture in construction assemblies. The visual design allows one to understand the complex effects that nonlinear material properties play in the transport of moisture. The model may be used to understand the transient heat and moisture diffusion and capillarity in any one-dimensional wall geometry. The model can employ either SI or IP units. This is particularly useful for design consultants, students, or architects who may be familiar with one system and not with the other. The model is equipped with a limited North American material property database. Future upgrades will introduce a wider range of materials, as manufacturers test all properties in a consistent manner. The model accounts for night sky radiation, as this can be an important thermal and moisture load in various climates in North America. This new feature allows one to take into account surface wetting during the night. The model contains new algorithms for modeling the effect of wind-driven rain as a function of building height. The model uses real-time meteorological data to account for the exterior environmental conditions that affect the performance of the envelope system. (For all U.S. locations, two weather data sets have been included, representing the 10% coldest and warmest weather periods from a 30-year period; for Canadian cit- 6 Buildings VIII/Moisture Model Inputs Principles
7 ies, one weather data set is included. The WYEC2 files are used for Canadian cities as full weather data, including rain, are not available to the public at present.) This new feature allows the user to compare the effect of climate on the performance of the structure. Interior conditions are set conditions and vary depending on time of year. The model's new visual interface was designed for simplicity and to assist the user by offering lists of predefined parameters for selection. EXPERIMENTAL VALIDATION The model is most likely the most validated and benchmarked model for hygrothermal applications. The validation of a numerical model requires reliable experimental investigations with well-documented initial and boundary conditions, as well as accurate material properties. The following three examples were chosen because they meet these criteria: Figure 5 Transient behavior of a stone facade. The output is the measured and calculated mean water content evolving with time. The actual weather input conditions are shown in the two figures above. The output is shown in the figures below (Künzel 1995). Moisture behavior of an exposed natural stone facade. The degradation of natural stone facades is mainly due to moisture-induced weathering or damaging processes. Therefore, these facades are often treated with water repellent or reinforcing chemicals that may not always be beneficial. Such a treatment not only reduces the water absorption but also the drying rate. In order to investigate the hygrothermal behavior and the durability implications of natural stone facades, sandstone samples were thoroughly examined in the laboratory to obtain reliable material parameters for the simulations. Afterward, the samples were dried and exposed to the natural climate in a field test. During this test, the exact climatic conditions were recorded and the moisture behavior of the samples was determined by weighing and NMRprofile measurements. The material parameters and the recorded weather data (hourly values of indoor and outdoor temperature, relative humidity, driving rain, and solar radiation) served as input for the calculations. Figure 5 shows a comparison of the calculated and the recorded water content of the facade samples as well as the climatic conditions during the observation period. This excellent agreement in total water content between experiment and calculation can be confirmed by examining the moisture profiles at certain time intervals in Figure 6. Figure 6 Transient behavior of a stone facade. Measured and calculated moisture content profiles for four subsequent time periods (Künzel 1995). Buildings VIII/Moisture Model Inputs Principles 7
8 graph dries mainly to the interior of the building, which prolongs the drying-out process compared to the wall in the bottom graph. The high vapor permeability of the mineral-fiber insulation results in an effective dry-out to both sides. However, in this case, the stucco must also have high permeability in order to avoid excessive condensation beneath its surface, which can cause frost damage. WUFI-ORNL/IBP MODEL INTERFACE/APPLICATION CASE To demonstrate the user-friendly capabilities of the model, an example case was developed. A snapshot of the master screen for the WUFI-ORNL/IBP model is displayed in Figure 8. The user can return to this screen after inputting all needed parameters. The following simple steps are required to set up a wall system: 1. The user develops a project. Within each project, the user may introduce up to two separate sets of modeling cases. The interface functions for data input are organized in the following three groups: Figure 7 Measured and calculated moisture content profiles at different time periods after finishing the construction for an EIFS with EPS insulation (top) and mineral wool (bottom) (Künzel 1995). Drying of masonry with exterior insulation. Exterior insulation finish systems (EIFS) applied on masonry can prolong its dry-out time. In severe cases, the construction moisture in the masonry can severely damage the stucco of the EIFS if moisture is accumulating beneath it through vapor diffusion. Therefore, a test house was erected with calcium silica brick masonry and insulated with two types of EIFS. The insulation layers were 80 mm thick and consisted of expanded polystyrene slabs (EPS) or high-density mineral fiber. Mineral-fiber insulation is mainly used for fire protection or sound insulation purposes. The drying process of the walls was monitored by drill probing the walls several times after completion of the house. Figure 7 depicts the measured and calculated moisture profiles over the cross section of the walls at subsequent time intervals. The results correspond well and they show a great influence of the insulation material on the drying behavior of the wall. Due to the rather low water vapor permeance of the EPS, the masonry in the top Component: The user specifies the modeling scenario and details of the envelope system of the modeling, such as geometrical makeup, the material parameters, orientation, rain parameters, surface characteristics, and initial conditions. Control: The user defines the time period for which the simulation is to be carried out as shown. Climate: The user defines the exterior and interior environmental exposure conditions of the construction. 2. Run. The user starts the simulation. During the calculation, WUFI-ORNL/IBP displays the computed thermal and hygric profiles as an animation. 3. Output. The user can display and print out the input data summary, check the status of the simulation, and view and print the results. 4. Options. The user can define the unit system (either IP or SI units), configure warnings, and select save options. All these functions are needed to establish each case within a project. Following the sequence order in the project explorer or in the menu bar, you can successfully prepare all inputs, perform the simulation, and review output results. Of significant value is that the user can watch the simulated performance of the wall envelope graphically while the simulation is being performed. This graphical presentation of all the important quantities as a function of time while the simulation is being performed is of excellent educational value. One of the main objectives during the development of the WUFI-ORNL/IBP model was to provide an educational value imparted by visually displaying the simultaneous heat and moisture performance of building envelope systems as a function of time and space. Also, providing many drop-down 8 Buildings VIII/Moisture Model Inputs Principles
9 Figure 8 Enter project account details. menus where the user simply selects rather than inputs the required parameters, permits a higher level of confidence that the simulation is being performed correctly. It is expected that future upgrades of the model will aim at providing a greater selection of construction materials. CONCLUSIONS Major progress has been achieved in the last few years in the development of advanced hygrothermal models. An easyto-use moisture engineering model is available to the building envelope design community. By keeping the input requirements to simply defining the wall structure, the user can easily determine the performance of a wide range of wall systems as a function of climate and interior environment. The additional degree of accountability also reduces the possibility of input errors. It is expected that as more accurate material properties are measured at ORNL, the existing limited material property database will be improved and be available to designers. Currently the WUFI-ORNL/IBP educational version is freely available to North America from the ORNL website, and the professional version from the Fraunhofer website, to the architectural and building envelope community. ACKNOWLEDGMENTS The authors would like to acknowledge the support of DOE Director of Building Research and Standards Ed Pollock and DOE Program Manager Arun Vohra to ORNL s new advanced hygrothermal activities at ORNL. Thanks are also due to ORNL Manager and Director Andre Desjarlais and Jeff Christian for their enthusiasm and support of this project. Finally, we would like to thank Mr. Bill Seaton, Director of Research for ASHRAE, for providing ASHRAE s environmental conditions and material properties, which was highly appreciated. REFERENCES Hens, H Modeling, Final Report. IEA-Annex 24, Task 1, ACCO, Leuven. Holm, A., and H.M. Künzel Combined effect of temperature and humidity on the deterioration process of insulation materials in ETICS. Proceedings of the 5th Symposium on Building Physics in the Nordic Countries, Göteborg, Vol. 2, pp Karagiozis, A.N Moisture engineering. Proceedings of the Seventh Conference on Building Science and Technology, Durability of Buildings Design, Maintenance, Codes and Practices, Toronto, Ontario, pp Karagiozis, A.N Advanced hygrothermal model MOISTURE-EXPERT, Oak Ridge National Laboratory, Report I. Künzel H.M Simultaneous heat and moisture transport in building components One- and two-dimensional calculation using simple parameters. IRB Verlag. Künzel, H.M., K. Kießl, and M. Krus Moisture in exposed building components. Proceedings of the inter- Buildings VIII/Moisture Model Inputs Principles 9
10 national symposium on moisture problems in building walls, Porto, pp Künzel, H.M., and K. Kießl Drying of brick walls after impregnation. Internationale Zeitschrift für Bauinstandsetzen 2 H.2, S., pp Künzel, H.M Austrocknen von Wandkonstruktionen mit Wärmedämmverbundsystemen. Bauphysik 20, H.1, S., pp Künzel, H.M More moisture load tolerance of construction assemblies through the application of a smart vapor retarder. Thermal Performance of the Exterior Envelopes of Buildings VII, pp Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Künzel, H.M., A.N. Karagiozis, and A. Holm WUFI- ORNL/IBP A hygrothermal design tool for architects ans engineers, Manual 40 in Moisture Analysis and Condensation Control in Building Envelopes. Salonvaara, M.H., and A.N. Karagiozis EIFS hygrothermal peformance due to initial construction moisture as a function of air leakage, interior cavity insulation and climate conditions. Thermal Performance of the Exterior Envelopes of Buildings VII, pp Atlanta: American Society of Heating, Refrigerating and Air-Conditiong Engineers, Inc. Trechsel, H.R Moisture control in buildings. Philadelphia: American Society for Testing and Materials. Trechsel, H.R Moisture Analysis and Condensation Control in Building Envelopes. Philadelphia: American Society for Testing and Materials. 10 Buildings VIII/Moisture Model Inputs Principles
Long-Term Hygrothermal Performance of Green Roofs
Long-Term Hygrothermal Performance of Green Roofs D. Zirkelbach B. Schafaczek H. Künzel, PhD Member ASHRAE ABSTRACT Green roofs are becoming more and more popular because their thermal inertia, combined
Influence of rain water leakage on the hygrothermal performance of exterior insulation systems
Influence of rain water leakage on the hygrothermal performance of exterior insulation systems Hartwig M. Künzel, Dr.-Ing. Department of Hygrothermics, Fraunhofer Institute for Building Physics; [email protected]
Frost Damage of Roof Tiles in Relatively Warm Areas in Japan
Frost Damage of Roof Tiles in Relatively Warm Areas in Japan Influence of Surface Finish on Water Penetration Chiemi IBA Hokkaido Research Organization, Japan Shuichi HOKOI Kyoto University, Japan INTRODUCTION
Drying of brick walls after impregnation
Drying of brick walls after impregnation H.M. Künzel and K. Kießl Fraunhofer-Institute of Building Physics (Director: Prof. Dr.-Ing. habil. Dr. h.c. Dr. E.h.mult. Karl Gertis) Abstract Elevated moisture
Frost Damage of Masonry Walls A hygrothermal Analysis by Computer Simulations
Frost Damage of Masonry Walls A hygrothermal Analysis by Computer Simulations K. SEDLBAUER, H.M. KÜNZEL INTRODUCTION AND OBJECTIVES Frost damage occurs especially if damp building elements are subjected
Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction
T e c h n i c a l n o t e Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction Number J450 February 2009 Controlling against moisture damage in structures depends upon proper system
Moisture Content in Insulated Basement Walls
Moisture Content in Insulated Basement Walls Peter Blom,PhD, SINTEF Building and Infrastructure; [email protected], www.sintef.no/byggforsk Sverre B. Holøs M.Sc. SINTEF Building and Infrastructure;
Wall Moisture Problems in Seattle
Wall Moisture Problems in Seattle Andre O. Desjarlais Achilles N. Karagiozis Michael A. Ki-Kramer ABSTRACT In the past few years, major moisture-related problems have appeared in the northwestern U.S.
Hygrothermal Simulations and Analysis of Solar- Driven Inward Water Vapor
ROXUL Hygrothermal Simulations and Analysis of Solar- Driven Inward Water Vapor January 2014 Prepared by: Building Science Consulting Inc. 167 Lexington Court, Unit 5 Waterloo, Ontario Canada N2J 4R9 www.buildingscienceconsultinginc.com
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions
Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions M. Bianchi Janetti 1, F. Ochs 1 and R. Pfluger 1 1 University of Innsbruck, Unit for Energy Efficient Buildings,
EPSRC Research Project EP/G00028X/1. Environmental Assessment of Domestic Laundering. Final Modelling Report
ESRU Report EPSRC Research Project EP/G00028X/1 Environmental Assessment of Domestic Laundering Final Modelling Report Kelly N J K, Markopoulos A and Strachan P A March 2012 Energy Systems Research Unit
Basement Insulation: Best Practices for Efficient, Durable, & Healthy Homes
Basement Insulation: Best Practices for Efficient, Durable, & Healthy Homes Midwest Regional Energy Codes Conference October 3, 2012 Indianapolis, IN Patrick H. Huelman Cold Climate Housing Coordinator
The Influence of Low-Permeance Vapor Barriers on Roof and Wall Performance
The Influence of Low-Permeance Vapor Barriers on Roof and Wall Performance J.F. Straube, Ph.D. ABSTRACT Low-permeance vapor barriers are widely used on the interior of wall and roof systems in large parts
BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS. Wagdy Anis, FAIA, LEED ap*
BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS Wagdy Anis, FAIA, LEED ap* Abstract: Six of the ways condensation can occur on cold surfaces in buildings are discussed here. They are: 1. Air Leakage,
Mold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
Field Performance of Different Interior Basement Insulation Systems
Field Performance of Different Interior Basement Insulation Systems Marc Zuluaga Robb Aldrich Dianne Griffiths, P.E. Associate Member ASHRAE ABSTRACT With the support of the Department of Energy s Building
Martin Krus, Klaus Sedlbauer, Herbert Sinnesbichler
Martin Krus, Klaus Sedlbauer, Herbert Sinnesbichler Artificial thermal bridge with a dew point switch to accomplish an appropriate control of the ventilation for the prevention of mould growth in buildings
THERMAL STORAGE WITH PCM VS. THERMAL INSULATION IN WARM AND HOT CLIMATES
THERMAL STORAGE WITH PCM VS. THERMAL INSULATION IN WARM AND HOT CLIMATES G. C HRISTOPH SPAEH, PE, LEED BD+C SUTTON KENNERLY & ASSOC., INC. 300 Pomona Dr., Greensboro, NC 27403 Phone: 336-855-0993 Fax:
Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film
Article Protecting the Building Envelope from Water Damage Vapor Retarders Play a Crucial Role in Moisture Management Whether we like it or not, moisture in the form of water vapor diffusion and humid
Moisture risk in prefabricated wooden wall elements (TES-elements) with a vapour retarder of OSB/3
Passivhus Norden 2013 Moisture risk in prefabricated wooden wall elements (TES-elements) with a vapour retarder of OSB/3 Silje Korsnes Author, SINTEF Building and Infrastructure, 7465 Trondheim, [email protected]
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E
An information series from the national authority on concrete masonry technology R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS TEK 6-2C Energy & IAQ (201) INTRODUCTION Single wythe concrete
10DBMC International Conference On Durability of Building Materials and Components LYON [France] 17 20 April 2005
10DBMC International Conference On Durability of Building Materials and Components Wall Cladding System Durability Lessons Learned from the Premature Deterioration of Wood-Framed Construction Clad with
Development of conservation compatible new materials for envelope retrofitting of historic buildings
Development of conservation compatible new materials for envelope retrofitting of historic buildings Carsten Hermann, Senior Technical Officer, Historic Scotland Glasgow is one of seven EFFESUS case study
Presented by: Jennifer Doyle, P.E., RRC, LEED AP
Presented by: Jennifer Doyle, P.E., RRC, LEED AP Moisture Gas: Molecules are spread out "Vapor" suspended in air forms a mixture, present everywhere Liquid: Molecules are closer Rain Condensation Pipes
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group Since water intrusion is among the most damaging problems
National Building Code of Canada 2010
National Building Code of Canada 2010 Emergency Change Issued by the Canadian Commission on Building and Fire Codes The table that follows lists two emergency changes that apply to the National Building
In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11,
In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1.5 hours of
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi
Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction
Post-insulation of cellar ceiling and cellar walls
WP5 Education and Economic Promotion Post-insulation of cellar ceiling and cellar walls Educational product: New lecture material for training modules dealing with knowledge and skills how to apply suitable
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration
Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
Determination of equilibrium moisture content of building materials: some practical difficulties
http://irc.nrc-cnrc.gc.ca Determination of equilibrium moisture content of building materials: some practical difficulties NRCC-48382 Kumaran, M.K.; Mukhopadhyaya, P.; Normandin, N. A version of this document
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
WUFI 2D. Calculation Example Step by Step. D. Zirkelbach Th. Schmidt H.M. Künzel M. Kehrer Ch. Bludau
WUFI 2D Calculation Example Step by Step D. Zirkelbach Th. Schmidt H.M. Künzel M. Kehrer Ch. Bludau WUFI 2D Short Introduction PREFACE This introduction will show you how to model a building component
STADIUM Software Overview. Durability and Service Life of Concrete Structures
STADIUM Software Overview Durability and Service Life of Concrete Structures Eric Samson Cementitious Barriers Partnership SIMCO Technologies Inc. August 2014 Who we are SIMCO is a specialized engineering
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
Curriculum Map Earth Science - High School
September Science is a format process to use Use instruments to measure Measurement labs - mass, volume, to observe, classify, and analyze the observable properties. density environment. Use lab equipment
EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS
EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS Thermal Properties ENGR 3350 - Materials Science Dr. Nedim Vardar Copyright 2015 Thermal Properties of Materials Engage: MSEIP Engineering Everyday Engineering
Molds and mildew are fungi that grow
Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate
Vapor Permeability Provides No Performance Benefit for in Ventilated Attics
Vapor Permeability Provides No Performance Benefit for Roofing Underlayments in Ventilated Attics Testing Shows Breathable Underlayment Provides Little or No Moisture Transfer Value in Asphalt Roofing
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
CONDENSATION. Section Break (Next Page)
CONDENSATION Elimination of condensation on or within walls and floors is as important as reducing the heat loss through the wall or floor. In addition to the moisture damage caused to buildings by condensation,
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
Performance of 8 Passive House Envelopes in Cold Climates
7 th Annual North American Passive House Conference September 27-30, 2012 Denver CO Performance of 8 Passive House Envelopes in Cold Climates Rolf Jacobson, LEED AP CSBR, University of Minnesota ZEB, Norwegian
Subject Index. MNL18-EB/Oct. 2009
Subject Index A adhered bonded wood products, 59 61 adsorption, 2 3 adsorption isotherm, 2 aerated concrete, 48 aerobiology, bacteria, 82 air ambient, 111 barrier systems, 18 19 barriers, high-rise, 416
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
Analysis II Façade Redesign: Architectural Precast Panels
Analysis II Façade Redesign: Architectural Precast Panels Analysis II Façade Redesign: Architectural Precast Panels Overview: This analysis covers the comparison of the current EIFS façade and my proposed
Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi
Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi Module - 03 Lecture 10 Good morning. In my last lecture, I was
Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract
Commissioning of Exterior Building Envelopes of Large Buildings for Air Leakage and Resultant Moisture Accumulation using Infrared Thermography and Other Diagnostic Tools Mario D. Gonçalves, Patenaude-Trempe
HVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
Opening the Bonnet. Prof Darren Woolf WYSINWYG 1
Opening the Bonnet Prof Darren Woolf WYSINWYG 1 WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2 WYSIWYG implies a user interface that allows the
TEXTILE FABRICS AS THERMAL INSULATORS
TEXTILE FABRICS AS THERMAL INSULATORS Zeinab S. Abdel-Rehim 1, M. M. Saad 2, M. El-Shakankery 2 and I. Hanafy 3 1 Mechanical Engineering Department of the National Research Center, Dokki, Giza, Egypt 2
*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.
Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.
Hygrothermal Performance of Basement Foundation Systems
Hygrothermal Performance of Basement Foundation Systems Patrick H. Huelman 1 and Marilou Cheple 2 Abstract This paper provides a brief review of below grade energy and moisture impacts on basement foundations,
Application of Building Energy Simulation to Air-conditioning Design
Hui, S. C. M. and K. P. Cheung, 1998. Application of building energy simulation to air-conditioning design, In Proc. of the Mainland-Hong Kong HVAC Seminar '98, 23-25 March 1998, Beijing, pp. 12-20. (in
Crawl space heat and moisture behaviour
Crawl space heat and moisture behaviour Miimu Airaksinen, Dr., Technical Research Centre of Finland, VTT [email protected], www.vtt.fi KEYWORDS: crawl space, moisture, evaporation from ground, ground
) and air spaces (R a
5.3.3 Thermal Resistance (R-value) Common thermal properties of materials and air spaces are based on steady state tests, which measure the heat that passes from the warm side to the cool side of the test
Building Information Modelling (BIM); How it Improves Building Performance. R.P. Kumanayake Lecturer, Department of Civil Engineering
Building Information Modelling (BIM); How it Improves Building Performance R.P. Kumanayake Lecturer, Department of Civil Engineering R.M.P.S. Bandara Lecturer, Department of Mechanical Engineering Faculty
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
Water Permeability vs Waterproof
ASCE Met Section Construction Group, Cooper Union Student Chapter, May 25, 2000 Water Permeability vs Waterproof by Patrick F. McGrath, Ph.D. Xypex Chemical Corporation, Richmond, B.C., Canada The paper
BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program
BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program Use of Moisture Measuring Devices in Evaluating Water Damage in Buildings July 2007 The evaluation of mold colonization of building
R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION
An information series from the national authority on concrete masonry technology R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS TEK 6-2B Energy & IAQ (2009) INTRODUCTION Single wythe concrete
Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015
EcoPelmet Pty Ltd c/- Geoff Hesford Engineering 45 Market Street FREMANTLE WA 6160 Version: Page 2 PREPARED BY: ABN 29 001 584 612 2 Lincoln Street Lane Cove NSW 2066 Australia (PO Box 176 Lane Cove NSW
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
The Optimum Basement Wall
The Optimum Basement Wall Solutions to the Wet Blanket Basement Problem February 27 th, 2014 1 Adapting to Change! We ve made significant advances in water management. Customers no longer accept that musty
WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.
WET/DAMP BASEMENTS PROBLEM. IS THIS BASEMENT LEAKING OR COULD WE HAVE ANOTHER PROBLEM? Water line arching up on wall in corners of basement. Water collecting on concrete floor starting in corners. ANSWER:
Roof Insulation Building. Energy. Environment friendly e-library
Roof Insulation Building Codes & Energy Efficiency Environment friendly e-library Building Code Driver Buildings consumer almost 50% of all energy. Experts believe that a 30% increase in building efficiency
Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving
346 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving S. Ferrari Politecnico
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
Measuring The Right Thing For Humidity Control It s the Dew Point Stupid!
Page 1 of 6 Measuring The Right Thing For Humidity Control It s the Dew Point Stupid! By Mike Schell, AirTest Technologies Corp. A version of this article appeared in the June 2004 edition of Indoor Air
Fire and Concrete Structures
Fire and Concrete Structures Authors: David N. Bilow, P.E., S.E., Director, Engineered Structures, Portland Cement Association 5420 Old Orchard Road, Skokie, IL 60077,Phone 847-972-9064, email: [email protected]
Adaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
Conductive and Radiative Heat Transfer in Insulators
Conductive and Radiative Heat Transfer in Insulators Akhan Tleoubaev, Ph.D. LaserComp, Inc., December 1998 Heat transfer for most thermal insulation materials occurs via both conduction and radiation.
CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER
International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)
Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings
Best2 Airtightness of Buildings Session WB6-2 Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Mario D. Gonçalves, Patenaude-Trempe and Robert Jutras, Air-Ins Introduction
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.
In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance
Repair of Spalling and Leaking Clay Brick Building Walls
B etter buildings Repair of Spalling and Leaking Clay Brick Building Walls Overview A few years after being built in Waterloo in 1980, a condominium of three, six-storey buildings showed severe spalling
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Exterior and Interior Insulation of Heavy Masonry Buildings. In North America and Norway. A comparison
Exterior and Interior Insulation of Heavy Masonry Buildings In North America and Norway A comparison Figure 1: Bygningsdetaljer 723.312 (SINTEF) Victoria Nordhagen ARCH 4672 March 8th 2012 Introduction
Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems
Abstract Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems M. Jaradat, R. Heinzen, U. Jordan, K. Vajen Kassel University (Germany), Institute
Natatorium Building Enclosure Deterioration Due to Moisture Migration
Buildings 2012, 2, 534-541; doi:10.3390/buildings2040534 OPEN ACCESS buildings ISSN 2075-5309 www.mdpi.com/journal/buildings/ Case Study Natatorium Building Enclosure Deterioration Due to Moisture Migration
Moisture Mitigation for Concrete Slabs
Moisture Mitigation for Concrete Slabs A brief description of alternative methods for dealing with slab moisture problems By Peter A. Craig M oisture-related problems with floor coverings and coatings
DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple
CHAPTER SEVEN L. Glicksman and J. Lin (eds), Sustainable Urban Housing in China, 116-123 2006 Springer. Printed in the Netherlands. DESIGN OF NATURAL VENTILATION WITH CFD Qingyan Chen INTRODUCTION As the
Common Problems with Walls
Common Problems with Walls Common Problems with Walls There are problems and concerns that are shared by all walls and siding installations. In this article, we will learn about the following commonly
A Kingspan Summary of a Building Science Corporation Report
Insulated Panels REVIEW & ANALYSIS OF EXTERIOR WALL ASSEMBLY PERFORMANCE A Kingspan Summary of a Building Science Corporation Report REVIEW & ANALYSIS OF EXTERIOR WALL ASSEMBLY PERFORMANCE Exterior Wall
RESNET National Rater Test Study Guide Outline
RESNET National Rater Test Study Guide Outline The RESNET national home energy rating standard spells out a listing of the knowledge base and skills set for Home Energy Ratings. Trainers and Rating Quality