Operating instructions



Similar documents
Operating instructions

Operating instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi 80e & 105e

User's Instructions. Alpha HE CB25/33 and HE SY25

GREENSTAR HEATSLAVE 12/18, 18/25, 25/32

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

For installation guide see reverse of book

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

/2010 US/CA

Response: The combi boiler. Response: The fit anywhere combi

Tankless Water Heater

Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger!

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Link-Up. Solid Fuel Association Guide to Central Heating.

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

SL280UHV SERIES GAS FURNACE WARNING

Factory owners must ensure the boiler is:

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Combi Eco Elite Range. User s Guide and Important Warranty Information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

Combi 30 HE. User s Guide and Important Warranty Information

GREENSTAR 24i Junior/28i Junior

MANAGEMENT AND USE OF WORK EQUIPMENT: PRESSURE SYSTEMS

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

Combi 24 HE. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Session 2: Hot Water Supply

Preventing Overheated Boiler Incidents

building engineering services association specification for: Domestic Heating

PBX Series Quick Fit Connector Bimetallic Steam Traps

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Vaillant s plain English guide to. simple, concise and precise

AMBASSADOR (KITCHEN), COUNTRYMAN (OUTDOOR) & CONSUL (BOILERHOUSE) CONSENSING BOILERS SENATOR (KITCHEN) & COUNTRYMAN (OUTDOOR) COMBI CONSENSING BOILERS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Trouble Shooting. Pump

Installation Instructions for Alarm Module Kit A043F059

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

BoilerMate SP. benchmark. user instructions A - C L A S S

A Class Air Source Heat Pump User Guide

Operating instructions. For the operator. Operating instructions. ecotec plus. Gas-fired wall hung high efficiency boiler GB, IE

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

How To Design A Gas Dryer

orlando OWNER S MANUAL

Hydraulic control unit series

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Energy Efficiency E-module - Guidance. Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector

CARING FOR YOUR WATER HEATER

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Operating Instructions & User s Information Manual VITODENS 100-W WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

User manual and Installation instructions

Manual for Fire Suppression & Methane Detection System

User Guide. Promax System Condensing System Boiler

WORCESTER COMMERCIAL BOILER SERIES GB162-65/80/100

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Condensing Boiler Efficiency

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Boiler Preparation, Start-Up and Shutdown

Electric Flow Boiler

HomeServices Terms and Conditions

High Output Boiler Systems

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Gas Instantaneous Water Heater

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Oil and Coolant Circulating Heating System. Model - OCSM

Mikrofill Ethos Condensing combination boiler

Operating Instructions & User s Information Manual VITODENS 100-W WARNING. IMPORTANT Read and save these instructions for future reference.

DEALING WITH PLUMBING AND HEATING EMERGENCIES

Continuous flow direct water heating for potable hot water

Heat Pump Water Heater IOM Manual

Look after your boiler so it can look after you

This section gives you some helpful information and tips on running your home and the equipment in it.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Installation and Servicing Instructions

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

Alpha CD13R,18R and 24R

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Service Manual Models: 502, 752, 1002, 1302,

ECOCIAT. Domestic hot water heat recovery unit

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Oil - kerosene burners

INSTALLATION & TECHNICAL MANUAL

Installation and maintenance instructions

HeatSource HS1800 Heater

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Transcription:

6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use.

Overview Regulations and directives Installation: 90/396/EEC gas appliance directive 92/42/EEC boiler efficiency directive 73/23/EEC low voltage directive 89/336/EEC EMC directive 97/23/EC pressure equipment directive current Gas safety (Installation and Use) Regulations The Building Regulations Building Standards (Scotland) IEE Wiring Regulations BS 7671 National and ByLaws of the local water undertaking Corgi registered required to work on the appliance (Competent Persons) Oftec registered required to work on the appliance (Competent Persons) Codes of practice: BS 6880 BS 6644 CP 342.2 BS 5449 BS 5546 BS 6891 Code of practice for low temperature hot water heating systems for output greater than 45kW Specification for Installation of gas-fired hot water boilers of rated inputs between 70kW (net) and 1.8 MW (net) (2nd and 3rd family gases) centralised hot water supply Forced circulation hot water systems Installation of gas hot water supplies for domestic purpose (2nd. Family Gases) Low pressure installation pipes BS 5410 Code of practice for Oil firing Part 2 BS 5854 & IM/11 Codes of Pracitice for flues (as appropriate) BS 7074 Application Selection & Installation of Expansion vessels & ancillary for sealed water systems Part 2 IGE/UP/1 Soundness testing & purging of industrial & commercial installations IGE/UP/2 Gas installation pipework and compressors on industrial and commercial premises IGE/UP/7 Gas installations in Timber framed buildings IGE/UP/10 Installation of gas appliances in industrial and commercial premises, part 1: flued appliances CISBE Guide Management of Health and & Safety at work regulations 1992 - Guidance note PM5 Health & Safety at work act 1974 Manual Handling Regulations 1992 The Electricity at Work Regulations, 1989 2 Operating instructions Logano G115 WS oil/gas-fired special boilers Issue 02/2006

Index 1 For your safety...............................................4 1.1 About this manual............................................4 1.2 Correct use................................................4 1.3 Key to symbols..............................................4 1.4 Please observe these notes.......................................4 2 Product description............................................5 3 Operation of the heating system...................................6 3.1 Switching on the heating system....................................6 3.2 Switching off the heating system....................................6 3.3 Emergency measures..........................................6 3.4 Check the operating pressure, if necessary top up with heating water and vent the system...7 3.4.1 When should you check the operating pressure?.........................7 3.4.2 Operating pressure, checking...................................7 3.4.3 Filling the heating system and checking for leaks.........................7 3.4.4Filling the heating system.......................................8 3.5 Operating tips...............................................9 3.6 Why is regular maintenance important?................................9 4 Trouble shooting............................................. 10 Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006 3

1 For your safety 1 For your safety 1.1 About this manual These installation and maintenance instructions contain important information for the safe and correct installation, initial start-up and maintenance of this boiler. In the following text, the Logano G215 WS oil and gasfired boilers will generally be described as the boiler. 1.2 Correct use The boiler is designed for generating heating water and domestic hot water (DHW) when used with hot water cylinder, for example, in detached homes or in apartment buildings or smaller commercial properties. 1.3 Key to symbols In these instructions, the following symbols are used: WARNING! RISK TO LIFE Identifies possible risks which may lead to serious injury or death if appropriate care is not taken. RISK OF INJURY/ SYSTEM DAMAGE Identifies potentially dangerous situations which might lead to medium or slight injuries or to material losses. PLEASE NOTE User tip for the optimum utilisation and setting of the control(s) plus useful information. WARNING! RISK TO LIFE by unqualified personnel. Installation, commissioning and maintenance must only be carried out by a specialist installer. Work on electrical and fuel-bearing components in particular must only be carried out by suitably qualified personnel. 1.4.1 If you notice a smell of gas WARNING! RISK TO LIFE through the explosion of volatile gases. There is a risk of explosion if you can smell gas. Keep naked flames away. Do not smoke. Do not use lighters. Avoid sparks! Do not operate electrical switches, including telephones, plugs or doorbells. Close the main gas shut-off valve. Open windows and doors. Warn all occupants, but do not use doorbells. Leave the building. Call your gas supplier and your local heating engineer from outside the building. If necessary, notify police or fire brigade! Immediately leave the danger zone if you hear gas escaping. Cross-references Cross-references to a specific point or another document are identified by an arrow. 1.4 Please observe these notes You will learn how to use your heating system by letting your installer instruct you when the system is handed over and reading these operating instructions carefully. Do not carry out any work on the boiler that is not described in these operating instructions. 1.4.2 Tips regarding the installation room WARNING! WARNING! RISK TO LIFE through poisoning. Insufficient ventilation can lead to dangerous flue gas leaks. Never close or obstruct air ducts and vent apertures or reduce their size. The boiler must not be operated, until the obstruction has been removed. RISK OF FIRE through flammable material or liquids. Never store flammable materials or liquids in the immediate vicinity of the boiler. 4 Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006

Product description 2 2 Product description This boiler is a low temperature boiler for oil or gas 1 combustion with modulating boiler water temperature control. Your specialist heating company has equipped the boiler with a suitable burner. The boiler comprises: Control device Boiler casing Boiler block with thermal insulation The control device monitors and controls all electrical boiler components. The boiler casing prevents energy losses and acts as sound insulation. The boiler block transfers the heat generated by the burner to the heating water. The thermal insulation prevents energy losses. Fig. 1 Boiler without burner 4 2 3 This product meets all basic requirements of relevant standards and directives. 1 Control device 2 Boiler casing 3 Boiler block with thermal insulation 4 Burner door casing Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006 5

3 Operation of the heating system 3 Operation of the heating system 3.1 Switching on the heating system Before switching the system on, check that the operating pressure is high enough, that the fuel supply at the main shut-off valve is open and that the heating system emergency stop switch is switched on. Switch the boiler water thermostat to "AUT" (Automatic). Switch the ON/OFF switch to ON (position "I"). This switches on the entire heating system. PLEASE NOTE Operating instructions, e. g. how to set the temperature, can be found in the control unit documentation. 2 I 0 3.2 Switching off the heating system Switch the ON/OFF switch on the control to OFF (position "0"). This switches the boiler and all its components OFF (for example the burner). Close the main fuel shut-off valve. 1 Fig. 2 Switching on the heating system (Logamatic 2000) 1 Set the boiler water thermostat 2 ON/OFF switch SYSTEM DAMAGE through frost. The heating system can freeze up, if it has been shut down. Leave the heating system switched ON as long as possible. Protect your heating system against freezing by draining the heating system and DHW pipework at the lowest possible point. 1 2 Fig. 3 Switching on the heating system (Logamatic 4000) 1 Set the boiler thermostat 2 ON/OFF switch 3.3 Emergency measures In the event of an emergency, e. g. a fire, proceed as follows: Close the main fuel shut-off valve. Isolate the heating system from the mains power supply via the heating system emergency stop switch or a corresponding domestic fuse. 6 Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006

Operation of the heating system 3 3.4 Check the operating pressure, if necessary top up with heating water and vent the system 3.4.1 When should you check the operating pressure? Recently topped-up heating water loses much of its volume in the first few days because it releases gases. This causes air pockets, and the heating system will start to rumble. After installing a new heating system, check the operating pressure daily for the first few days. If necessary top up with heating water and bleed the radiators. After a while the operating pressure will only need to be checked monthly. If necessary top up with heating water and bleed the radiators. 3.4.2 Operating pressure, checking The installer will have set the red needle on the pressure gauge to the required operating pressure (at least 1 bar pressure). Check that the pressure gauge needle is within the green range. Top up with heating water if the pressure gauge needle is below the green range. 2 1 3.4.3 Filling the heating system and checking for leaks Before commissioning the heating system, check for leaks to prevent problems during operation. Pressurise the heating system to 1.3x permissible operating pressure (observe the safety pressure of the safety valve). 3 SYSTEM DAMAGE over pressure during leak testing. Pressure, control and safety equipment may be damaged through excessive pressure. When you carry out a leak test, make sure that no pressure, control or safety equipment is fitted which cannot be isolated from the boiler water chamber. Fig. 4 Pressure gauge for sealed systems 1 Red needle 2 Pressure gauge needle 3 Green marking Shut off the pressure expansion vessel from the system by closing the cap valve. Check the connections and pipework for leaks. Opening the mixing and shut-off valves on the hot water (primary) side. Fill the system via an approved filling link. Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006 7

3 Operation of the heating system 3.4.4 Filling the heating system Filling and refilling of the heating circuit must been carried out by a method that has been approved by the Water Regulation Advisory Scheme (WRAS), for the type of heating appliances, i.e. Domestic (in-house) Fluid Category 3. Non-Domestic (other than in-house) Fluid Category 4. Depending on the Fluid Category the approved method should comprise of the following: 1. Requirements Fluid Category 3 systems (fig see below) Control valve (stop valve) including a double check valve on the mains cold water supply pipe Temporary connection to e removed after filling (filling loop) Control valve (stop valve) on the heating system pipework Fig. 5 Requirements Fluid Category 3 systems 2. Requirements Fluid Category 4 systems (fig see below) Control valve (stop valve) on the mains cold water supply pipe Strainer Verifiable Backflow Prevention Device with reduced pressure Zone(RPZ valve assembly) incorporating a Type BA air gap Tundish Control valve (stop valve) on the heating system pipework Shut off the pressure expansion vessel from the system by closing the cap valve. Slowly fill the heating system. Observe the pressure gauge whilst filling. Close the water tap and the boiler fill & drain valve once the required operating pressure has been reached. Fig. 6 Requirements Fluid Category 4 systems 8 Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006

Operation of the heating system 3 3.5 Operating tips Correct fuel This heating system requires fuel of the correct type and grade to ensure its proper operation. Use the following fuel only: SYSTEM DAMAGE through incorrect fuel. Only use the fuel specified. Follow the advice of your installer if you want to convert your heating system to another type of fuel or use fuel with a different specification. Location Company stamp/date/signature BOILER DAMAGE through contaminated drawn into the boiler air. Never use chlorinated cleaning agents or halogenated hydrocarbons (as, for example, contained in spray cans, solvents or cleaning agents, paints and adhesives). Avoid very dusty atmospheres. 3.6 Why is regular maintenance important? Heating systems should be regularly maintained for the following reasons: to achieve a high level of efficiency and to operate the system economically (low fuel consumption), to achieve a high level of operational reliability, to maintain the highest level of environmentally responsible combustion. SYSTEM DAMAGE through a lack of, or unsatisfactory, cleaning and maintenance. Have your system inspected, cleaned and maintained annually by your installer or a service engineer. We recommend you enter into a contract covering an annual inspection, and maintenance as required. Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006 9

4 Trouble shooting 4 Trouble shooting We differentiate between two types of faults Burner faults and Control unit and heating system faults. A fault lamp on the burner illuminates if the burner develops a fault. Generally, such faults can be reset by pressing the reset button on the burner. Control device and heating system faults are indicated on the control device display, subject to the control device being equipped with a display. For further information see control device documentation. Correcting burner faults Press the burner reset button ( burner documentation). 1 SYSTEM DAMAGE through frost. The heating system can freeze up, if it has been switched OFF through a fault shutdown. Try to remedy the fault. Contact your installer immediately if this is not possible. Fig. 7 Resetting the burner 1 Burner 10 Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006

Notes Operating instructions Logano G215 WS oil/gas-fired special boilers Issue 02/2006 11

Your installer: Buderus Cotswold Way, Warndon, Worcester WR4 9SW Tel.: 01905 752794, Fax: 01905 753130 www.buderus-commercial.co.uk In the UK, Buderus is a trading name of BBT Thermotechnology Ltd.. BBT Thermotechnik GmbH D-35573 Wetzlar www.heiztechnik.buderus.de info@heiztechnik.buderus.de