1 User s Guide and Important Warranty Information Combi 0 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.
2 Contents Natural Gas Main Combi 0 HE G.C.N o Section Page.0 Quick Reference Guide.0 Troubleshooting.0 Fault Indication 6.0 System Pressure & Temperature Clearances Care of the Boiler Legislation 0 Where fitted, user label for optional timer to be applied here 8.0 Emergency 9.0 Warranty & Service The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 988. Applications for the copyright owner s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park, Stanier Way, Derby, DE 6BF. Full acknowledgement of author and source must be given. Boiler Controls - see opposite page for Operating Quick Reference Guide WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages ISO 900 FM 00866
3 .0 Quick Reference Guide 0 bar ON/OFF/ Selector Switch Indicator Neons Central Heating Temperature Control Domestic Hot Water Temperature Control System Pressure Gauge Position of Optional Timer OFF Position The boiler will not operate. Central Heating & Hot Water Both Heating & Hot Water will operate. Domestic Hot Water Hot Water will operate. Hold for approx 5 seconds and release. Power On Indicator - The indicator will illuminate when there is power to the boiler. Domestic Hot Water Indicator - The indicator will illuminate when hot water is being supplied to a tap or shower. Boiler On - The indicator will illuminate when there is a demand for heat to the boiler. Indicator Neons Burner On Indicator - The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water. Central Heating Temperature Control Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 5-85 C. Domestic Hot Water Temperature Control Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 5-65 C. 0 bar Central Heating System Pressure - The normal operating water pressure is between and.0 bar. If the pressure exceeds bar the safety pressure valve will operate and a fault is indicated. Contact your Installer.
4 Boiler not working START.0 Troubleshooting Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). Is the ON/OFF/ Select Switch in the ( ) position and the Power ON indicator lit? Is the ( ( ) on? ) light on and the If no gas, consult your supplier. Boiler On Indicator Burner On Indicator Check electricity to the boiler is switched on. Power On Indicator Boiler operating satisfactorily. Is the Central Heating System Pressure needle in the GREEN section, between and.5 bar? Is the ( ) indicator neon on? Flame Failure Neon 0 bar If the reading falls below bar repressurise the system as described in section.. Turn the ON/OFF/ Selector Switch to. If boiler does not
5 Troubleshooting Is the Timer ON and calling for heat? Is the Room Thermostat (if fitted) set high enough? Typical examples of external timer CH ON CH OFF Turn Room Thermostat to maximum setting (typical example shown). Ensure timer is set for Central Heating ON (see any instructions supplied with timer) CONTACT YOUR INSTALLER OR SERVICE ENGINEER. If you don t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible. 5
6 .0 Fault Indication. Air Flow Monitor TE: The neons annotated have a dual function, indicating the temperature of the central heating water when constantly illuminated or begin to flash to indicate a fault.. The boiler is fitted with an air pressure sensing device. This monitors the flue system. Safety Thermostat Neon Flame Failure Neon Air Flow Monitor Neon Pump/Low Pressure Neon Sensor Fault Neons. If the ( ) neon illuminates it indicates that the flue or flue terminal is blocked or obstructed in some way, or that there is an internal fault. If there is no external blockage of the flue terminal that can be easily removed contact your Installer or Service Engineer (Fig. ).. Pump Fault or Low Pressure. The neon ( ) will illuminate if the circulating pump is faulty or the system pressure drops below the minimum requirement (Fig. ). Fig.. Check the pressure gauge as described on page 8. If the pressure is in the normal range, a pump fault is indicated. Contact your Installer or Service Engineer to determine the nature of the fault.. Sensor Fault. When either of the ( ) or ( ) neons is illuminated a fault on one of the temperature sensors is indicated (Fig. ). Contact your Installer or Service Engineer.. Pump Protection. With the selector switch in the on position (Fig. ) the pump will automatically operate for minute in every hours to prevent sticking..5 Safety Thermostat. Your Baxi Combi HE is fitted with an additional safety devices, which shut down the boiler in the event of the system, boiler or flue overheating. The safety thermostat neon ( ) will light in this instance (Fig. ). Fig..6 Flame Failure. The red flame failure neon ( ) will illuminate in the event of the burner failing to light, when incomplete lighting of the burner occurs or blockage of the condensate drain (Fig. )..7 To the Safety Thermostat or Flame Failure Fig.. To reset: Turn the selector fully anti-clockwise against the spring pressure to the position for at least two seconds and release (Fig. ).. If after turning the selector to the position the boiler does not relight or the safety thermostat or flame failure operates repeatedly, causing boiler shutdown, a fault is indicated. Your Installer or Service Engineer should be contacted as soon as possible. 6
7 .0 System Pressure & Temperature Fig. Fig bar bar Normal Pressure Requires Repressurising. Central Heating System Pressure. The normal operating water pressure is between and.5 bar (Fig. ). If the pressure exceeds bar the safety pressure valve will operate and a fault is indicated (Fig. 6). Contact your installer.. It may be necessary to repressurise the system occasionally (Fig. 5). A filling device (the filling loop) will be fitted on the system. If you are unsure of its position, or cannot identify it, consult the installer who fitted the boiler.. The filling loop will probably consist of two taps and a separate metal braided hose with connection fittings.. Only when repressurising should the hose be connected between the two taps. Ensure that the nuts on the pipe ends are tightened onto the taps. 5. Fully open one of the taps first, and then while watching the pressure gauge, carefully open the second tap. 0 bar 6. When the needle on the gauge is indicating or more turn both taps off. 7. Disconnect the metal braided hose from the taps (a small amount of water may be present) and remove it. Keep the hose in a safe place for future use. Fig. 6 Fault. Temperature Control. Central Heating: The central heating hot water flow temperature can be adjusted between 5 C (± 5 C) minimum and 85 C (± 5 C) maximum.. Turn the control knob clockwise to increase the temperature (Fig. 7). In normal winter usage we recommend that the central heating temperature be set at maximum.. Domestic Hot Water: The temperature of the domestic hot water can be adjusted by turning the control knob clockwise to increase up to a maximum of 65 C (Fig. 8).. The temperature of the water is also dependent on the water flow rate and the temperature of the mains coming into the house. 5. By slightly reducing the flow from the tap the temperature will increase up to the maximum if required. 6. The flow rate can be reduced down to as low as.5 litre/min. The boiler will still recognise the need to heat the water. Fig. 7 Central Heating Fig. 8 Temperature Control Domestic Hot Water Temperature Control 7
8 5.0 Clearances 5mm Min 50mm 0mm/5mm Min see *TE: 5. For your Safety. This appliance must have been installed in accordance with the manufacturer s instructions and the regulations in force. 00mm Min. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. GB - Heating Industry definition meaning England, Scotland, Wales, Northern Ireland, Isle of Man and the Channel Isles. Your boiler must not be operated without the casing correctly fitted. 780mm. Do not interfere with any sealed components on this boiler. 5. Take note of any warning labels on your boiler. 6. Your boiler should have the following minimum clearances for Safety and Maintenance (Fig. ):- 00mm Min Top Bottom Left side Right Side Front - 00mm - 00mm - 5mm - 5mm - 5mm (In Operation) - 50mm (For Servicing) *TE: The boiler can be operated with a clearance of 5mm at the right. This is also sufficient for routine maintenance. However a clearance of 0mm is required if it is necessary to remove the secondary heat exchanger. This should be considered when siting the appliance and in the event of any subsequent alteration in the area of installation. 7. If your boiler is installed in a compartment, do not use it for storage purposes. Do not obstruct any purpose provided ventilation openings. 8. Flammable materials must not be stored in close proximity to your boiler. 50mm Min For Servicing Purposes 9. Avoid skin contact when your boiler is in operation, as some surfaces may get hot e.g. pipework. 0. Ensure that the flue terminal, outside the house, does not become damaged or obstructed, particularly by foliage.. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 5mm Min In Operation 8
9 6.0 Care of the Boiler 6. Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO T USE ABRASIVE CLEANING AGENTS. 6. Protection & Precaution. The boiler incorporates an integral frost protection feature that will operate when the selector switch is in the ( ) position. If the boiler temperature falls below 5 C, then the boiler will operate until the water temperature has been raised.. If a system frost thermostat has been fitted (your installer will be able to advise you), then to operate correctly and protect your system, the gas and electricity must be left on and the appliance set in the central heating mode.. The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated. To prevent seizure, the pump will operate for approximately minute if it has not run in the last hours. 6. To Shut Off the Boiler (Fig. 9). For short periods: Turn the selector switch to the Off position.. For long periods: Turn off the selector switch, electricity and gas supplies. Fig. 9 OFF Position (Selector Switch) If your home is to be left unoccupied for long periods during cold weather the boiler and whole system should be drained unless there is additional frost protection.. Your installer will advise you about frost protection and draining the system. 9
10 7.0 Legislation 7. Installation, Commissioning, Service & Repair. This appliance must be install in accordance with the manufacturer s instructions and the regulations in force. Read the instructions fully before installing or using the appliance.. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations.. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant ACS modules, is deemed competent.. In IE (Eire), this must be carried out by a competent person as stated in I.S. 8 Domestic Gas Installations. All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning or online at The boiler meets the requirements of Statutory Instrument The Boiler (Efficiency) Regulations 99 No 08 and is deemed to meet the requirements of Directive 9//EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels:- Type test for purpose of Regulation 5 certified by: Notified Body 005. Product/Production certified by: Notified Bodies 005 & For GB/IE only. 7. Benchmark Commissioning Checklist. Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales).. All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist.. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service.. The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack. 0
11 8.0 Emergency Warning! If you smell gas Turn off the gas supply at the meter and call your gas supplier immediately. It is possible to isolate the boiler at the isolating valve (Fig. 0). In GB, Transco operate a hour emergency service and the telephone number will be listed in your telephone directory. Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. In an Emergency If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; Gas Tap. Using a suitable open ended spanner, turn the square nut on the gas tap through 90 ( / turn) to isolate the gas supply at the boiler (Fig. 0).. The water isolating valves are positioned under the boiler and can be closed by turning their taps to the right towards the wall (Fig. 0). Fig. 0. Call your Installer or Service Engineer as soon as possible. Heating Flow and Heating Return Isolating Valves
12 Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Term & Conditions Months Free Warranty - register today To receive your months free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on Date of Installation D D M M Y Y Installer Details (name, address and contact number(s)) Our promise to you If you experience a fault with your new boiler, we aim to provide a safe and high quality repair service supported by our dedicated national network of highly skilled engineers. If your installer can t resolve the problem for you, we will do everything we can to get an engineer out to you as quickly as possible. Nothing in this warranty will affect your statutory consumer rights. What you need to do if you experience a problem with your heating system or the operation of the boiler You should always contact your installer first, because the fault may not be related to the boiler. If your installer confirms that the fault is within the boiler it self and he/she can t repair it, our friendly customer service team is on hand to help. Simply call our service division heateam on to book an engineer visit or for any general advice that you may need. Our contact centre is open Monday to Friday 8am - 6pm, weekends and Bank Holidays 8.0am - pm, excluding Christmas Day and New Years Day. When calling heateam it would be helpful if you could have the following information to hand:- boiler serial number (see opposite). boiler make and model number. Your installer name and address details. Proof of purchase (if you do not have the boiler serial number). What this warranty covers Free of charge repair or replacement of components found to be faulty from manufacture. Free of charge replacement of the complete unit provided always that the failure is related to a manufacturing fault that cannot be repaired or is uneconomic to repair. The warranty runs for months from the date your product is installed. What this warranty does not cover Repairs to boilers which haven t been installed and commissioned properly, and as set out in the installation instructions (this includes the need to flush the system effectively and add a suitable corrosion inhibitor). Any damage caused by hard water scale deposits and/or aggressive water resulting from corrosion. Any other defects or failures, either in the connected heating system or outside of the boiler itself. Information Label All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. MAIN A Trading Division of Baxi Heating UK Ltd (87956) A Division of Baxi Group Brooks House, Coventry Road, Warwick. CV LL After Sales Service Technical Enquiries Website e&oe Faults caused by inadequate supply of electricity, gas or water to the property. Installations within commercial settings for which this boiler was not designed. Reimbursement of any third party repair or replacement costs that we haven t been told about or agreed with you in advance. Compensation for consequential losses (e.g. loss of earnings, business losses, stress and inconvenience) arising from a production breakdown, including repair delays caused by factors outside our reasonable control. Annual Service To ensure you receive the maximum efficiency from your boiler we recommend your boiler has an annual service so you and your family can continue to enjoy heating and hot water comfort. To arrange an annual service from one of our Baxi Heating UK Ltd heating experts, please call UK Comp No Iss 6-8/09
User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on
You can rely on User Guide and Important Warranty Information Suprima HE Range Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Combi 24 HE. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi 4 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 0 Contents
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Combi Eco Elite Range. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi Eco Elite Range Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents Natural Gas
User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler
User Guide and Important Warranty Information Suprima 30L - 100L Wall Mounted Fan Assisted Balanced Flue Gas Boiler These instructions are for use with boilers whose serial numbers end C (or higher) only.
Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler
User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
User Guide. Promax System 12-15 - 18-24 - 32. Condensing System Boiler
United Kingdom en User Guide Condensing System Boiler Promax System - 5-8 - 4 - Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents Natural
User Guide. Main Heat 12-15 - 18-24. Condensing Central Heating Boiler
United Kingdom en User Guide Condensing Central Heating Boiler Main Heat 12-15 - 18-24 Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
User Guide. Titanium Combi 24-28 - 33-40. Condensing Combination Boiler
United Kingdom en User Guide Condensing Combination Boiler Titanium Combi - 8 - - Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS
sustainable solutions under one roof HEATING HOT WATER VENTILATION Hi-Spec Warm Air Heaters Publication No. ZZ 0782-11 June 2012 with System E-T & Basic Control USERS INSTRUCTIONS J25 - G.C. No. 42-416-99
Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER
Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER G.C. NUMBER SABRE 25 HE N 470 94 70 SABRE 29 HE N 470 94 71 SABRE 35 HE N 470 94 72 Contents Introduction Page Dear customer 2
User Guide. EcoBlue Advance Heat 13-16 - 19-25 - 30. Gas Fired Wall Mounted Condensing Boiler
United Kingdom en User Guide Gas Fired Wall Mounted Condensing Boiler EcoBlue Advance Heat 13-16 - 19-25 - 30 Please keep these instructions in a safe place. If you move house please hand them over to
User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)
User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers
For the owner Instructions for use ecotec Wall hung room sealed fan assisted condensing boilers GB Contents Specified use Notes on these instructions Specified use... Notes on these instructions.... Storage
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
GREENSTAR HEATSLAVE 12/18, 18/25, 25/32
8 716 106 253f 30/3/10 12:59 Page 1 USER INSTRUCTIONS & CUSTOMER CARE GUIDE FLOOR STANDING OIL FIRED CONDENSING COMBINATION BOILER CONVENTIONAL FLUE & ROOM SEALED FLUE GREENSTAR HEATSLAVE 12/18, 18/25,
Look after your boiler so it can look after you
Look after your boiler so it can look after you This guide covers the steps you can take to ensure that your Vokèra boiler continues to operate efficiently and safely. No-one knows your boiler better than
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser
FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on
GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER
GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER 6 720 611 927-00.1O THE APPLIANCE IS FOR USE WITH NATURAL GAS OR
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
Design Utility Lever Thermostatic Bath Shower Mixer
Design Utility Lever Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
BoilerMate SP. benchmark. user instructions A - C L A S S
A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the
Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List
Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification
Energy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
Thermostatic bar showers. Troubleshooting and maintenance
Thermostatic bar showers Troubleshooting and maintenance General Fault Diagnosis Outlet too cold Outlet too hot - Hot water supply must be 10ºC higher than desired mixed outlet for the mixer to operate
Vaillant s plain English guide to. simple, concise and precise
Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when
Getting the best from your urn
444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat
GREENSTAR 24i Junior/28i Junior
USER INSTRUCTIONS WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 4i Junior/8i Junior FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER The appliance is for use with Natural
Artisan Thermostatic basin mixer. Fitting Instructions & Contents List
Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature
LHZ USER GUIDE LHZ User Guide LHZ would like to thank you for purchasing your LHZ radiator. You have purchased a high quality, German designed and manufactured heating device, which will give you soft
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
Morco House Riverview Road Beverley HU17 0LD
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email [email protected] Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS
AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification
MULTIPOINT BF Gas Fired Balanced Flue Water Heater
Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 GB (04.10) JS Natural Gas Main Multipoint
Contact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: [email protected]
ferroli Boiler Replacement Optimax HE- Modena HE
ferroli Boiler Replacement Optimax HE- Modena HE Introduction The new Ferroli Modena 32C HE high efficiency condensing combination boiler is an ideal replacement for the Ferroli Optimax HE 31 C and the
Artisan Thermostatic Bath Shower Mixer
Artisan Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank you for choosing
service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear
3in1 Plan Dear As per our recent conversation, the SGS Service Plan offers complete peace of mind because for a small premium your central heating equipment will be serviced and covered in the event of
Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
INSTALLATION & TECHNICAL MANUAL
The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: [email protected]
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
A boiler breakdown can really be costly
Platinum Protection Britain is switching to Energy Efficiency Central Heating Breakdown Insurance Warranty A boiler breakdown can really be costly Unless you care for your boiler with HomePlatinum from
Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service
Housing Solutions Limited Terms and Conditions Fixmy Boiler Service Housing Solutions Limited Crown House, Crown Square Waldeck Road Maidenhead SL6 8BY Tel: 0800 876 6060 Web: www.fixmy.org.uk Terms and
MODELS BR517R & BR517S (G.C. 32-032-11 & 32-032-12) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires
O W N E R G U I D E MODELS BR517R & BR517S (G.C. 32-032-11 & 32-032-12) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires *Covered by GB Patent 2.202.622.B This Owner Guide is
Contact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: [email protected]
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers
Installation and Servicing Instructions Alpha 240/280 Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0870
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Having a gas appliance installed or serviced? Doing home improvements?
Keeping you safe Having a gas appliance installed or serviced? Think Safety. Think RGI. In your home, safety comes first. If you are having a gas appliance installed, serviced or repaired, always use a
Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Colonial Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading
Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB
Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible
Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant
Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Safe management of industrial steam and
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:
Operating instructions. For the operator. Operating instructions. ecotec plus. Gas-fired wall hung high efficiency boiler GB, IE
Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall hung high efficiency boiler GB, IE Inhaltsverzeichnis Inhaltsverzeichnis 1 Notes on the documentation...3 1.1 Storing
Instructions For SF 6 Refill Kit
S&C Vista Underground Distribution Switchgear UnderCover, Vault-Mounted, and Pad-Mounted Styles Instructions For SF 6 Refill Kit TABLE OF CONTENTS Section Page Section Page INTRODUCTION..................................
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
VIESMANN. Installation and service instructions VITOTROL 100. for contractors
Installation and service instructions for contractors VIESMANN Vitotrol 100 Type UTDB-RF2 Room temperature controller with digital time switch and wireless receiver For applicability, see the last page
www.morphyrichards.co.uk
43922 rev2:x 06/01/2010 15:06 Page 1 Upon registration with Morphy Richards (UK & ROI only) Register online for your 2 year guarantee. See back of this instruction book for details. (UK and Ireland customers
Combi 30 HE. Installation & Service Instructions
Installation & Service Instructions Combi 30 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 2009 Natural Gas Main
HomeServices Terms and Conditions
HomeServices Terms and Conditions Contents Definitions 03 The Contract 04 Start date 04 General Exclusions 11 Payment 12 Cancellation 13 Appointments 16 Product Renewal 16 Changes to contract 16 Safety
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
Daikin Altherma Hybrid Heat Pump
Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes
Ducoterra Radiant Heating Panel Installation Manual
Ducoterra Radiant Heating Panel Installation Manual 1. Introduction Your new radiant heating panels are designed to heat living and working spaces rapidly and efficiently by radiant heating. Like the sun,
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.
Boiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product
Wireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable