Series 4000. Installation Guide Internal AC Outlet Option Kit



Similar documents
Direct AC Wiring Option Installation Guide

Series User s Guide Series 4000 Badge Timeclock

Gateway Port Replicator User Guide

Timeclock. Maintenance and Troubleshooting Guide 400 Series Timeclock

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

About the HotWire Slot Standalone Shelf

FortiFone QuickStart Guide for FON-370i

GSM-EXT Cable Assembly Installation Guide

FortiFone QuickStart Guide for FON-670i and FON-675i

Sun Enterprise Optional Power Sequencer Installation Guide

Power Over Ethernet Adapters POE101

Regulatory Compliance Statement

Operation Instructions PowerCool Series

AastraLink RP 500. Installation Guide Rev 03

Sun Management Center Change Manager Release Notes

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

Technical Support. Support Information

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

First Data FD130 Terminal. Quick Set-up Guide

Wireless Optical Travel Mouse

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Solaris 10 Documentation README

WARNING CANADIAN D.O.C. WARNING

USB Mini Print Server PS121. Installation Guide

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Media Changer/Recorder VGP-XL1B. Safety Information

Maintenance and Troubleshooting Guide Series 400 Terminal

USER S GUIDE V: BC118 Portable Boombox. For the most up-to-date version of this User s Guide, go to

ASUS Miracast Dongle E-MANUAL E8741

User guide. Miracast Wireless Display IM10

Quick-Start Guide. Arrival Sensor

Migrating Log Manager to JSA

SmartDock for Xperia ion User guide

Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

Power Supply Guide Version 1.0 for D-Show

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

USB 3.0 to M.2 NGFF SSD Enclosure with UASP

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Sun StorEdge A5000 Installation Guide

Wireless Optical Mouse

Mini Speaker. Printed in China Part No P Version D. CWA BT300 Product Information Guide

InnoMedia ESBC B. Quick Install Guide. 1

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In

HLWLAN b/g/n Transceiver Kit

How To Install A Basler Aviator Gige Camera

M.2 NGFF SSD to 2.5in SATA Adapter

Sun Management Center 3.5 Update 1b Release Notes

SunFDDI 6.0 on the Sun Enterprise Server

alkaline fisher-price.com

User guide. Stereo Bluetooth Headset SBH70

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Triple Expansion Chassis

On/Off Relay Switch and 3-Way Switch Kit

Lumencor SOLA light engine Instruction Manual

User Guide. LXX35-LED Light Source. Luxxor LXX35-LED User Guide. Contents

IBM Lotus Enterprise Integrator (LEI) for Domino. Version August 17, 2010

User guide. Stereo Bluetooth Headset SBH80

Lumination TM LED Luminaires Light Bar Retrofit Kit Series

Wireless Internet Keyboard and Laser Mouse

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

3-IN-1 DIGITAL MUSIC PLAYER

In-Site Motion Webcam

Wireless Keyboard and Optical Mouse Bundle

TM111. ERP Integration for Order Management (Shipper Specific) COURSE OUTLINE. Course Version: 15 Course Duration: 2 Day(s)

FTP-1000 Touchpad/Display. Installation Manual. Stay. Away. Disarm. Quick Exit

Radiometrics Guide to FCC & Canada Compliance. for Unintentional Radiators

Adaptive Log Exporter Service Update

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)


FSC130 SAP Bank Communication Management

Instruction Manual PC55O. With PC5OORK Keypad. 1996, 2002 Digital Security Controls Ltd. Toronto, Canada Printed in Canada R3

Open Networking Adapter 1101GT Quick Install Guide

Nevco, Inc. Installation Manual

HP POS Keyboard with MSR for Point of Sale System. User Guide

3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support

User guide. Stereo Bluetooth Headset SBH50

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

REPLACING THE SSL CERTIFICATE

InnoMedia ESBC B. Quick Install Guide. 1

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

MiniBrute Connection software editor 1.0.3

M2M Cellular Signal Amplifier

Network Management Card. Installation and Quick Start Manual

Sun StorEdge RAID Manager Release Notes

CS z/os Application Enhancements: Introduction to Advanced Encryption Standards (AES)

Short Form Description / Sommaire: Carrying on a prescribed activity without or contrary to a licence

Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server

User s Manual VTECH Printed in China

Read this document before using this product.

ARCHOS (

EPSON USB/Parallel Adapter User s Guide

Installation & User Manual

Bounce & Spin ZebraTM

OPERATOR S Manual All specifications are subject to change without notice

AXIS 291 1U Video Server Rack Installation Guide

Transcription:

Installation Guide Internal AC Outlet Option Kit Series 4000 Instructions for installing the internal AC outlet option in the Series 4000 badge timeclock Document Part Number: 4702573-002 Document Revision: A

The information in this document is subject to change without notice and should not be construed as a commitment by ADP, Inc. ADP is not responsible for any technical inaccuracies or typographical errors which may be contained in this publication. Changes are periodically made to the information herein, and such changes will be incorporated in new editions of this publication. ADP may make improvements and/or changes in the product and/or the programs described in this publication at any time without notice. This document or any part thereof may not be reproduced in any form without the written permission of Kronos Incorporated. All rights reserved. 2001, Kronos Incorporated. ADP provides this publication "as is" without warranty of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. The ADP Logo is a registered trademark of ADP of North America, Inc. Enterprise etime is a trademark and etime is a registered trademark of Automatic Data Processing, Inc. CardSaver, Datakeeper, Datakeeper Central, Gatekeeper, Gatekeeper Central, Imagekeeper, Improving the Performance of People and Business, Jobkeeper, Jobkeeper Central, Keep.Trac, Kronos, the Kronos logo, ShopTrac, ShopTrac Pro, the ShopTrac logo, Solution In A Box, Start.Time, TeleTime, Timekeeper, Timekeeper Central, TimeMaker, and VisionWare are registered trademarks of Kronos Incorporated. CommLink, Comm.Mgr, DKC/Datalink, HyperFind, Kronos Connect, Kronos e-central, Labor Plus, Prism, Smart Scheduler, Starter Series, Start.Labor, Start.Quality, Start.WIP, Tempo, the Tempo logo, Timekeeper Decisions, Timekeeper Express, Timekeeper Web, Workforce Activities, Workforce Accruals, Workforce Central, Workforce Central Suite logo, Workforce Decisions, Workforce Express, Workforce Manager, Workforce Scheduler, Workforce Smart Scheduler, Workforce TeleTime, Workforce Timekeeper, Workforce Genie, Workforce Professional, Workforce Mobile Time, and Workforce Web are trademarks of Kronos Incorporated. Adaptive Server is a trademark of Sybase, Inc. iseries and WebSphere are trademarks, and AIX, AS/400, and IBM are registered trademarks of International Business Machines Corporation. Lotus and 1-2-3 are registered trademarks of Lotus Development Corporation. Carbon Copy and OpenVMS are trademarks of Compaq Computer Corporation. pcanywhere is a trademark of Symantec Corporation. Cognos, Impromptu, and PowerPlay are registered trademarks, and PowerCube is a trademark of Cognos Incorporated. Crystal Reports is a registered trademark of Crystal Decisions. Ethernet is a registered trademark of Xerox Corporation. HandLink is a trademark of Time and Technology Systems. HandPunch is a trademark of Recognition Systems Corporation. INFORMIX-OnLine is a registered trademark of Informix Software, Inc. INTERSOLV is a registered trademark of Intersolv, Inc. Java and all Java-based trademarks and logos referenced in this document are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. Microsoft and Windows NT are registered trademarks and Windows 95 is a trademark of Microsoft Corporation in the United States and/or other countries. Netscape and Netscape Navigator are registered trademarks of Netscape Communications Corporation in the United States and other countries. Net8 is a trademark, and ORACLE, SQL*Net, and SQL*Plus are registered trademarks of Oracle Corporation. NexTrak is a trademark of Intellisys Corporation. Corel and Quattro are registered trademarks of Corel Corporation or Corel Corporation Limited. PeopleSoft is a registered trademark of PeopleSoft, Inc. Pervasive.SQL is a registered trademark of Pervasive Software Inc. in the United States and/or other countries. Show N Tel is a registered trademark of Brooktrout Technology, Inc. Solaris and Sun are registered trademarks of Sun MicroSystems, Inc. in the United States and other countries. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company Ltd. Velcro is a registered trademark of Velcro Industries B.V. Visual DataFlex is a registered trademark of Data Access Corporation. All other trademarks are the property of their respective owners.

When using and applying the information generated by ADP products, customers should ensure that they comply with the applicable requirements of federal and state law, such as the Fair Labor Standards Act. FCC Compliance After testing, this equipment complies with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it can cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case, the user, and not Kronos Incorporated, is required to correct the interference. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Canadian DOC Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Cet appareil numérique respecte les limites de rayonnement de bruits radioélectriques applicables aux appareils numériques de classe A, prévues au Règlement sur le matériel brouilleur du ministère des Communications du Canada. EN 55022 (CISPR 22) This product is a Class A product. In a domestic environment, it may cause radio interference in which case the user may be required to take adequate measures. Published by ADP, Inc. ADP, Inc. One ADP Boulevard Roseland, NJ 07068 For more information, see the following ADP, Inc. Web page: http://www.adp.com Document Revision History Document Revision Product Version Release Date A 1.0 September 2001

ADP, Inc.

Description Description The internal AC outlet allows you to secure the power connection for the Series 4000 timeclock inside the timeclock itself. The internal AC outlet option kit includes the following items:! AC outlet! Enclosure to house, ground, and anchor the outlet to the timeclock base! Screws and hex nuts to ground and install the AC outlet Caution You must have a licensed electrician connect the internal AC outlet to an AC power line. Attention Vous devez faire appel à un électricien agréé pour relier la prise c.a. interne à la source d alimentation électrique. Internal AC Outlet Option Kit Installation Guide 1

Before You Begin Before You Begin Electrical wiring must comply with all applicable national, federal, state, and local codes and standards. Use the documentation to guide you through the installation process as follows: 1. Follow the instructions in the Series 4000 Badge Timeclock Installation Guide (that shipped with the timeclock), until it refers you to this Internal AC Outlet Option Kit Installation Guide. At that time, you should have completed the following:! Run an AC power line through the wall at the point of entry into the timeclock! Mounted the base of the timeclock to the wall! Ensured that power to the AC power line is turned off 2. Follow the instructions in this guide, starting with Installing the Internal AC Outlet on page 3. 3. Go back to the Series 4000 Badge Timeclock Installation Guide and continue following those instructions, beginning with Installing the Transformer in Chapter 2. Caution The AC line that supplies power to the timeclock must be equipped with an appropriate disconnect device (proper fuse or circuit breaker). Do not connect the Series 4000 timeclock s power line to circuits being used for electrical devices that draw large amounts of power, such as air conditioning units, electrical motors, and compressors. Also avoid running communications cable near devices that interfere with data transmission (for example, large electrical motors, flourescent light ballasts, and transformers). Attention La source utilisée pour alimenter le terminal doit être munie d un dispositif de disjonction adéquat (fusible ou disjoncteur de circuit). Ne branchez pas le timeclock de la série 4000 sur les mêmes circuits que ceux qui alimentent des appareils électriques qui consomment beaucoup de courant, comme les climatiseurs, les moteurs et les compresseurs. En outre, assurez-vous que le cable de communication ne passe pas près d appareils électriques qui pourraient causer des interférences et nuire à la transmission des données (par exemple, les gros moteurs, les ballasts et les transformateurs). 2 ADP, Inc.

Installing the Internal AC Outlet Installing the Internal AC Outlet Caution Before you begin, ensure that power to the AC line you will use to connect to the internal AC outlet is turned off. 1. Route the AC power line into the timeclock and through the hole at the base of the molded wall inside the timeclock. The following illustration shows how to route the line through the wall and into the timeclock: Number Description 1 AC line routed into the timeclock 2 Wires threaded through an access hole at the base of the molded wall Internal AC Outlet Option Kit Installation Guide 3

Installing the Internal AC Outlet The following illustration shows the knockout holes you can use to run an external power line up through the bottom of the timeclock. Thread the line as shown by callout 2 in the previous illustration. Number Description 1 Access holes for running cable into the timeclock 2. Have a licensed electrician connect and assemble the internal AC outlet. Warning You must have a licensed electrician connect the internal AC outlet to an AC power line. This connection requires 14 AWG (or higher) conductors to the AC outlet installed within the timeclock. Also, the AC line must be equipped with an appropriate disconnect device (proper fuse or circuit breaker). The electrician must connect the ground wire from the AC line to the stud on the AC outlet enclosure, and then connect the grounding strap between the stud and the ground screw on the AC outlet itself. 4 ADP, Inc.

Installing the Internal AC Outlet Avertissement Vous devez faire appel à un électricien agréé pour relier la prise c.a interne à la source d'alimentation électrique. Seuls des conducteurs de calibre 14 AWG (ou plus petits) peuvent être branchés à la prise c.a. interne. En outre, la source utilisée pour alimenter le timeclock doit être munie d'un dispositif de disjonction adéquat (fusible ou disjoncteur de circuit). L'électricien doit connecter le fil de mise à terre de la ligne c.a. à la tige de l'enveloppe de la prise, puis connecter la tresse de mise à terre (fournie) entre cette même tige et la vis de mise à terre sur la prise elle-même. Number Description 1 Internal AC outlet enclosure 2 AC line connection to the outlet 3 Ground wire 4 Grounding strap Internal AC Outlet Option Kit Installation Guide 5

What To Do Next 3. Complete the assembly of the internal AC outlet using the following steps, and referring to the following illustration: a. Connect the AC outlet to its enclosure using two 6-32 x 1/2 inch screws. b. Attach the AC outlet assembly to the timeclock. What To Do Next If you purchased the optional backup battery, refer now to the Backup Battery Option Kit Installation Guide that you received with the option kit. To continue assembling the timeclock, return now to the Series 4000 Badge Timeclock Installation Guide and continue with Installing the Transformer in Chapter 2. 6 ADP, Inc.