1 Lumencor SOLA light engine Instruction Manual Lumencor, Inc NW Greenbrier Parkway, Beaverton, OR T F
2 Emissions Certifications This equipment has been tested and found to comply with the limits of EMC directive 2004/108/EC. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Safety Certifications 2006/95/EC CB Scheme CE Declaration of Conformity TUV NRTL Listing TUV Canadian Listing TUV European License 1 SOLA light engine Instruction Manual
3 Table of Contents 1 Introduction 2 Precautions and Warnings 3 Installation and Operating Instructions 4 Spectral Output 5 Routine Maintenance and Trouble Shooting 6 Customer Support 7 Product Specifications 8 Connectors 9 Declaration of Conformance 10 Warranty 2 SOLA light engine Instruction Manual
4 1. Introduction The Lumencor SOLA light engine (SOLA LE) is designed for laboratory use by bioanalytical researchers and/or developers of life science instrumentation. The light engine provides a white light output by combining 6 discrete, bright, light outputs directly to a sample; or in the case of fluorescence microscopy, to the objective. Model numbering for SOLA LE is defined as follows: SOLA 6-YYY-ZZ. 6 denotes the number of colors, YYY denotes a unique customer code and ZZ denotes option and revision. The first Z denotes simultaneous output S and the second Z denotes the revision level. The light sources within the SOLA LE are controlled by software; either via a serial interface (RS-232 or USB) to a computer running a Lumencor supplied GUI or a third party microscopy software application. The only manual control is a power switch on the rear panel to turn on/off the 24-30VDC power into the unit. A green power indicator on the rear cover is lit ( ON ) when the power supply is connected to the SOLA LE and the power switch is in the on position. 2. Precautions and Warnings {Précautions et mises en garde} A few simple practices will ensure trouble-free operation for the life of the light engine. Les quelques règles simples suivantes permettront d assurer un fonctionnement fiable pendant toute la durée de service de la source lumineuse. Safety Instructions: Please read and follow all safety instructions provided BEFORE using your new SOLA light engine. Failure to comply with the safety instructions may result in fire, electrical shock, or personal injury and may damage or impair protection provided by equipment. Please save all safety instructions. Instructions de sécurité: Veiller à lire et à respecter toutes les instructions de sécurité fournies AVANT d utiliser le nouveau SOLA afin d écarter les risques d incendie, de décharge électrique, de blessure corporelle et de possibles dommages ou défaillance de la protection offerte par l appareil. Conserver toutes les instructions de sécurité. Safety Definitions {Définitions relatives à la sécurité}: Warning: Statements identify conditions or practices that could result in personal injury. Avertissement: déclarations qui identifient des situations ou des pratiques susceptibles d entraîner des blessures corporelles. Caution: Statements identify conditions or practices that could result in damage to your equipment. Attention: déclarations qui identifient des situations ou des pratiques susceptibles d endommager le matériel. Safety Items {Mesures de sécurité}: 3 SOLA light engine Instruction Manual
5 Warning: DO NOT use an unapproved power supply. The Lumencor-supplied external power supply is recommended for use with the SOLA light engine. Alternate 24-30VDC power supplies may be used provided that the current is limited to 7.9A max. Also, it is imperative that it has output over-current protection, as the power input of the SOLA LE is not fused. The equipment is required to be supplied by a DC power source that has been assessed to meet the requirements of a limited current circuit per clause 9.3 of IEC Connect the AC power cord to a receptacle with a protective safety (earth) ground terminal. Avertissement : NE PAS utiliser une alimentation électrique non homologuée. Il est conseillé d utiliser l alimentation électrique externe fournie par Lumencor avec la source lumineuse SOLA. Il est possible d utiliser une autre alimentation électrique continue V à condition que l intensité soit limitée à 7,9 A maximum. En outre, il est impératif qu elle présente une protection de sortie contre les surintensités, car l entrée d alimentation du SOLA ne comporte pas de fusible. Le matériel doit être alimenté par une source d alimentation continue qui a été déclarée conforme aux critères d un circuit d énergie limitée en vertu de la clause 9.3 de CEI Brancher le cordon électrique sur une prise de courant protégée par une borne de terre. Warning: DO NOT stare into the output of the light engine. The brightness of this light source is higher than most commercial lighting fixtures and is intended to couple directly into a microscope or other bioanalytjcal instrument. Avertissement: NE PAS regarder directement la sortie de la source lumineuse. L intensité lumineuse de cette source est supérieure à celle de la majorité des appareils d éclairage disponibles dans le commerce et est conçue pour un raccordement direct à un microscope ou autre appareil de bioanalyse. Caution: DO NOT open the unit. There are no serviceable parts inside and opening the light engine enclosure will void the manufacturer s warranty. Attention: NE PAS ouvrir l appareil. Il ne contient aucune pièce réparable et l ouverture de son boîtier a pour effet d annuler la garantie. Caution: DO NOT set liquids on the light engine. Spilled liquids may damage your light engine. Attention: NE PAS placer de liquide sur la source lumineuse. Les liquides renversés peuvent endommager la source lumineuse. Caution: DO NOT drop the light engine. It contains glass optical components that could be damaged or misaligned by the shock produced by a drop onto a hard surface. Attention: NE PAS laisser tomber la source lumineuse. Elle contient des composants optiques en verre susceptibles d être endommagés ou désalignés par le choc résultant d une chute sur une surface dure. 4 SOLA light engine Instruction Manual
6 DISCLAIMER: Lumencor shall not be liable for injury to the user or damage to the product resulting from the SOLA light engine being used in a way for which it was not intended and in complete disregard for all posted safety precautions and warnings. AVIS DE NON-RESPONSABILITÉ: Lumencor décline toute responsabilité pour les blessures corporelles ou les dommages au produit résultant d une utilisation du SOLA autre que celle prévue et du mépris total de toutes les mesures de sécurité et mises en garde affichées. 3. Installation and Operating Instructions The SOLA light engine ships with the following list of standard components. 1. SOLA light engine configured with one white output. 2. One 28V/7.9A power supply (Lumencor part no ). 3. One 6ft AC power cord for the power supply (for North American customers, Lumencor part no , for UK customers, Lumencor part no and for European customers, Lumencor part no ). 4. One USB-to-RS232 cable (Lumencor part no ). 5. One 3mm LLG adapter with one 3mm LLG, 1 meter (Lumencor part no ). When setting the SOLA LE up for use, be sure to place the unit on a hard surface and avoid blocking or restricting airflow at the air inlets or exhaust ports on the enclosure. Restricting the airflow will cause the unit to operate at elevated temperatures and will result in decreased product life and/or premature failure. Position the unit in such an orientation that allows unrestricted access to the DC power connector. In an emergency, you may need to disconnect power to the unit quickly. The SOLA light engine can either be controlled by a Lumencor supplied GUI, by 3rd party laboratory software or by the Remote Control Accessory (RCA) via the RS-232 port. The GUI provides a quick and easy way to control your new light engine. You will have the ability to turn the source within the unit on/off, adjust the power of the source from minimum to maximum power. Refer to the photo below of the rear panel for the location of the various connectors. Rear Panel of SOLA light engine 5 SOLA light engine Instruction Manual
7 3.1 GUI Installation Installation instructions follow for GUI control of the SOLA light engine. Connectivity between the computer and your SOLA LE can be accomplished one of two ways; either using a RS-232 straight-thru cable or using the provided USB-to-RS232 adapter cable. Both methods are covered below. GUI Installation and Operating Instructions (using RS-232 straight-thru cable) 1.Download the zip file for the SOLA GUI from 2.Unzip the file and run setup.exe to install the SOLA GUI. 3.Connect the RS-232 cable between the PC and the SOLA LE. 4.Connect the power supply to the SOLA LE. 5.Toggle the power switch on the rear panel to the ON 1 position. The green LED next to the switch should light. 6.Run the GUI by going to the Program Menu and selecting SOLA Controller. 7.In the COM pulldown menu, select the COM port assigned to serial communications. Generally this is COM1. [If you are unsure which one that is then go to Control Panel, then System, then the Hardware tab. Select Device Manager to see the hardware profile. Expand PORTS (COM & LPT) to see which COM port is assigned to the Communications Port and select that port in the GUI.] The PC should now have control of all color channels in unison in the SOLA light engine. You will have the ability to turn all colors ON or OFF and adjust the intensity of all sources in unison. Next, hit the INIT button. THIS STEP IS REQUIRED TO RE-ESTABLISH THE COMMUNICATION LINK WHENEVER THE SOLA LIGHT ENGINE IS POWER CYCLED OR WHENEVER THE GUI IS STARTED. GUI Installation and Operating Instructions (using USB-to-RS232 cable) 1.Download the zip file for the SOLA GUI from 2.Unzip the file and run setup.exe to install the SOLA GUI. 3.Connect the USB-to-RS-232 cable between the PC and the SOLA LE. If the PC does not recognize the FTDI device in the cable then you must run the FTDI driver installer, CDM20814_Setup.exe. 4.Connect the power supply to the SOLA LE. 5.Toggle the power switch on the rear panel to the ON 1 position. The green LED next to the switch should light. 6.Run the GUI by going to the Program Menu and selecting SOLA Controller. 7.In the COM pulldown menu, select the COM port assigned to USB-to-Serial communications. [If you are unsure which one is correct then go to Control Panel, then System, then the Hardware tab. Select Device Manager to see the hardware profile. Expand PORTS (COM & LPT) to see which COM port is assigned to the USB-to-Serial Comm Port and select that port in the GUI.] The PC should now have control of all color channels in unison in the SOLA light engine. You will have the ability to turn all colors ON or OFF and adjust the intensity of all sources in unison. Next, hit the INIT button. (THIS STEP IS REQUIRED TO RE-ESTABLISH THE COMMUNICATION LINK WHENEVER THE SOLA LIGHT ENGINE IS POWER CYCLED OR WHENEVER THE GUI IS STARTED.) 6 SOLA light engine Instruction Manual
8 4. Spectral Output The spectra of the SOLA light engine s white output (BLUE) is shown below along with a 75W Xenon trace (GOLD) and a 120W metal halide lamp output (GREEN). 5. Routine Maintenance and Trouble Shooting Remove any built-up dust or accumulation on the air intake ports. A vacuum may be used to remove debris so that a steady supply of air is available for cooling. It is recommended that these dust-filters be cleaned by a gentle suction device at least every 6 months and more often in dusty or smoke-filled environments. There are no user-replaceable components or sub-assemblies in SOLA light engines. 7 SOLA light engine Instruction Manual
9 6. Customer Support T: E: W: Specification Detail Temperature Operating 32 to 95 F (0 to 35 C) Non-operating -4 to 158 F (-20 to 70 C) Humidity Operating and non-operating 0 to 80% relative humidity, non-condensing Altitude Operating Non-operating Dimensions (LxWxH) Weight Lifetime 0 to 10,000 feet (3,048 meters) 0 to 20,000 feet (6,096 meters) 11.0 x 7.0 x 4.0 in / 27.9 x 17.8 x 10.2 cm 9 lb / 4.1 kg > 15,000 hr Input Power Requirements VDC / 7.9A Warm-up Period Protection Sound Level Connectivity Warranty Less than 1 minute IP Rating of X0 Sound Level at 1 meter < 65db(A) RS-232, USB 36 months parts and labor for end users M: Lumencor, Inc., NW Greenbrier Parkway, Beaverton, OR U.S.A. 7. Product Specifications The SOLA must be operated and stored within the environmental conditions specified. 8 SOLA light engine Instruction Manual
10 8. Connectors 8.2 RS-232 Connector This port conforms to standard RS-232 Interface Protocol. Pins Definition DC Characteristics 1, 2, 3, 4, 6, 7, 8 DCD, RXD, TXD, DTR, D3R, RTS, CTS VCC = 5.0V, Vilow (max) = 0.8V, Vihigh (min) = 2.4V, Iilow = 0.5mA, Iihigh = 1.0μA 5 Gnd 9 N/C DB9 Connector Pin Definitions 9. Declaration of Conformance Manufacturer: Lumencor, Inc NW Greenbrier Parkway, Beaverton, OR USA We declare under our sole responsibility that the SOLA Light Engine conforms to the following directives and norms: EMC directive 2004/108/EC 2006/95/EC CB Scheme CE Declaration of Conformity TUV NRTL Listing TUV Canadian Listing TUV European License 10. Warranty The SOLA light engine is backed by a 36 month warranty to end users. 9 SOLA light engine Instruction Manual
SOLA SE II Light Engine Instruction Manual
SOLA SE II Light Engine Instruction Manual Lumencor, Inc. Document Number 52-10034, Rev. A www.lumencor.com Emissions Certifications This equipment has been tested and found to comply with the limits of
Operation Instructions PowerCool Series
Operation Instructions PowerCool Series TOP VIEW BOTTOM VIEW PDCOOL-05RA PDCOOL-00RK PDCOOL-5R PDCOOL-0R ALSO AVAILABLE Thank you for purchasing the PowerCool Series component cooler and power distribution.
Regulatory Compliance Statement
Regulatory Compliance Statement 0560 EU Declaration of Conformity The declaration of conformity may be consulted at www.kobo.com/userguides SAR Limits The exposure standard for wireless devices employs
User Guide. LXX35-LED Light Source. Luxxor LXX35-LED User Guide. Contents
User Guide Luxxor LXX35-LED User Guide LXX35-LED Light Source Contents Symbol Descriptions... 3 Set Up... 6 Operation... 8 Mounting... 9 Cleaning... 10 Troubleshooting... 10 Ratings & Specifications...
Gateway Port Replicator User Guide
Gateway Port Replicator User Guide Using the Port Replicator Identifying features Connecting and disconnecting the port replicator 1 Using the Port Replicator Top Power button Component Icon Description
OPERATING MANUAL PUBLIC ADDRESS POWER AMPLIFIER PA-9336
OPERATING MANUAL PUBLIC ADDRESS POWER AMPLIFIER PA-9336 1 UNPACKING AND INSTALLATION Although it is neither complicated to install nor difficult to operate your PA amplifier, a few minutes of your time
AD511 Active Iridium Antenna User Manual Mar 12 V4.0
AD511 Active Iridium Antenna User Manual Mar 12 V4.0 AD511 Active Iridium Transmitter/Receiver Antenna with up to 160 metres of coaxial down-lead and DC Power Break-In Box for Iridium Satellite Systems
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION
UR Series LED Upgrade Kit Includes: 48" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL
Backup Scanner Module
Backup Scanner Module Catalog Number 1747-BSN Installation Instructions 2 Backup Scanner Module Important User Information Because of the variety of uses for the products described in this publication,
Direct AC Wiring Option Installation Guide
Revision A Direct AC Wiring Option Installation Guide The direct AC wiring option enables you to wire AC power directly in to the ADP InTouch. The option kit contains the following parts. 25mm 12mm Caution:
FortiFone QuickStart Guide for FON-370i
FortiFone QuickStart Guide for FON-370i FortiFone QuickStart Guide for FON-370i Revision 2 August 17, 2015 Copyright 2015 Fortinet, Inc. All rights reserved. Fortinet, FortiGate, FortiCare and FortiGuard,
USER S GUIDE V:1614-0805-10. BC118 Portable Boombox. For the most up-to-date version of this User s Guide, go to www.gpx.com
USER S GUIDE V:1614-0805-10 BC118 Portable Boombox For the most up-to-date version of this User s Guide, go to www.gpx.com Warnings and Precautions CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE
Operation Manual. Multi Channel Power Amplifier DPA-430L
Operation Manual Multi Channel Power Amplifier DPA-430L Welcome A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent
16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)
16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg) ŸGuide d'installation rapide (1) ŸTechnical Specifications (3) ŸTroubleshooting (4) 1.02 1. Avant de commencer Contenu
FortiFone QuickStart Guide for FON-670i and FON-675i
FortiFone QuickStart Guide for FON-670i and FON-675i FortiFone QuickStart Guide for FON-670i and FON-675i Revision 2 September 25, 2015 Copyright 2015 Fortinet, Inc. All rights reserved. Fortinet, FortiGate,
L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR
MECHANICAL CHARACTERISTICS CARACTERISTIQUES MECANIQUE PRINCIPAL TECHNICAL CHARACTERISTICS CARACTERISTIQUES TECHNIQUES PRINCIPALES 3 possible versions - Single indicator - Momentary action pushbutton (1
Sun Management Center Change Manager 1.0.1 Release Notes
Sun Management Center Change Manager 1.0.1 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0891 10 May 2003 Copyright 2003 Sun Microsystems, Inc. 4150
Read this document before using this product.
VistaMAX Series Safety Precautions Read this document before using this product. Download and read the full user manual for complete information (see the VistaMAX Support File Access document for download
Sun Enterprise Optional Power Sequencer Installation Guide
Sun Enterprise Optional Power Sequencer Installation Guide For the Sun Enterprise 6500/5500 System Cabinet and the Sun Enterprise 68-inch Expansion Cabinet Sun Microsystems, Inc. 901 San Antonio Road Palo
Lumination TM LED Luminaires Light Bar Retrofit Kit Series
GE Lighting Installation Guide Lumination TM LED Luminaires Light Bar Retrofit Kit Series BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING AVERTISSEMENT RISK OF FIRE OR ELECTRIC
Sun StorEdge A5000 Installation Guide
Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-7273-11 October 1998,
GSM-EXT Cable Assembly Installation Guide
GSM-EXT Cable Assembly Installation Guide For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/mywebtech General Information The GSM-EXT cable assembly is used to connect
Tablet Management Rack 16
Tablet Management Rack 16 User's Guide Table of Contents Hazard Symbols Review... 2 Components... 2 Charging Set-up... 3-4 LED and Syncing... 4-5 Cleaning and Maintenance... 6 Specifications... 6 Service
User Manual: Important Safety and Operating Instructions
Delta-Q IC Series IC650 IC900 IC1200 User Manual: Important Safety and Operating Instructions Save these instructions. This manual contains important safety and operating instructions for the Delta-Q IC
SunFDDI 6.0 on the Sun Enterprise 10000 Server
SunFDDI 6.0 on the Sun Enterprise 10000 Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-3610-11 November 1999, Revision A Send
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
767 Diagnostic System
767 Diagnostic System 3.5v 767 Wall Transformer Patent Pending Listed to: UL 60601-1 CSA C22.2 No. 601 Thank you for purchasing the Welch Allyn 3.5v 767 Wall Transformer. This manual is meant to provide
Professional USB to Serial Adapter Hub with COM Retention
Professional USB to Serial Adapter Hub with COM Retention ICUSB2321X ICUSB2322X ICUSB2324X *actual product may vary from photos *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
Instruction Sheet PDS SERIES. Single Circuit Power Sequencer FRONT VIEW POWER ON I. DOWN 120V 12A 60Hz REAR VIEW. (PDS-615R Shown)
Instruction Sheet PDS SERIES Single Circuit Power Sequencer FRONT VIEW POWER ON I SEQUENCE SYSTEM OFF 120V-12A-60Hz UNSWITCHED STATUS REMOTE 5 6 CLOSED - All channels on OPEN - All channels off UP COM
4- and 8-Zone Power Amplifier Installation and Setup Guide
4- and 8-Zone Power mplifier Installation and Setup Guide VETISSEMENT! Pour réduire les risques d incendie, ne pas installer cet appareil dans une armoire qui est plus petit que 20" (50.8 cm) de large
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information
Owner s Manual Phoenix CAM
PO Box 8680 Madison, WI 53708 Owner s Manual Phoenix CAM Installation, Operation & Service Instructions Read and Save These Instructions Low amp draw, balanced airflow characteristics and maximum velocity
USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854
USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854 FCC Information This equipment has been tested and found to comply with the limits for a Class B digital
ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS
EHD TRACK LEVEL, (SET LEVEL ON PLASTIC HEADER. DO NOT PLACE LEVEL ON ALUMINUM TRACK.) TRACK IS FLUSH WITH TOP OF HEADER JUNCTION BOX IDLER PULLEY LOCATOR PINS LOCATOR PINS OPERATOR DOOR STOP JUNCTION BOX
BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:
WTI Part No.: 13963 Rev.: PM Series Metered Rack Mount PDUs Models Covered: PM-8HS20-1 PM-16VS30-1 PM-24VS30-1 PM-24VS30-D PM-8HS20-2 PM-16VS30-2 PM-24VS30-2 PM-24VS30-Y PM-16VS20-1 PM-24VS20-1 PM-24VS20-D
Zebra RW 420 Mobile Battery Eliminator Kits
Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA Zebra RW 420 Mobile Battery Eliminator Kits Installation Instructions September, 2010 RW 420 Mobile Battery Eliminator
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Open Networking Adapter 1101GT Quick Install Guide
Open Networking Adapter 1101GT Quick Install Guide 2016 Avaya Inc. 1 NN48800-300 01-07 2016 Avaya Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure that the information
ES-3305P V2 / ES-3308P V2. Quick Installation Guide. 09-2013 / v1.0
ES-3305P V2 / ES-3308P V2 Quick Installation Guide 09-2013 / v1.0 1 COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
INVENTEK SYSTEMS ISM34x-USB Embedded Serial-to-WiFi Module es-wifi 802.11 a/b/g/n, Bluetooth 4.0, NFC
INVENTEK SYSTEMS ISM34x-USB Embedded Serial-to-WiFi Module es-wifi 802.11 a/b/g/n, Bluetooth 4.0, NFC Preliminary Data Sheet Page 1 Table of Contents 1 GENERAL DESCRIPTION... 3 2 PART NUMBER DETAIL DESCRIPTION...
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Wideband Optical Splitters FOS Series
Wideband Optical Splitters FOS Series Guide to Installation and Operation M949-9100-103 13 Mar 2014 Miranda Technologies 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 2C6 Tel. 514-333-1772 Fax.
Solaris 10 Documentation README
Solaris 10 Documentation README Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0550 10 January 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network Circle, Santa
VoiceTone T1 USER S MANUAL
VoiceTone T1 USER S MANUAL Important Safety Instructions 1 Read these instructions. 2 Keep these instructions. 3 Heed all warnings. 4 Follow all instructions. 5 Do not use this apparatus near water. 6
About the HotWire 7900 10-Slot Standalone Shelf
TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed
FERRORESONANT BATTERY CHARGERS
WorkHorse SERIES 1 FERRORESONANT BATTERY CHARGERS Installation and Operating Instructions Applied Energy Solutions, LLC. One Technology Place Caledonia, New York 14423 (585) 538-4421 www.appliedenergysol.com
ETRX3USB ETRX3USB-LRS ETRX3USB+8M ETRX3USB-LRS+8M PRODUCT MANUAL
Telegesis TG-ETRX357USB-PM-014-102 ETRX3USB Product Manual 1.02 ZigBee USB STICKS: ETRX3USB ETRX3USB-LRS ETRX3USB+8M ETRX3USB-LRS+8M PRODUCT MANUAL 2013 Telegesis (UK) Ltd ETRX3USB Product Manual (Rev
VS-0202 VS-0204. User Manual
User Manual VS-0202 VS-0204 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.
Compact I/O End Caps/Terminators
Installation Instructions Compact I/O End Caps/Terminators Catalog Numbers 1769-ECL, 1769-ECR Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval
ZigBee Extender 3. Features. Supported Models and Requirements. Important Safety Instructions. What Is Included: Specifications
ZigBee Extender 3 Features The Card Access ZigBee Extender 3 operates as a ZigBee (IEEE 802.15.4) router and mesh extender. The Extender is designed to improve ZigBee signal latency that can occur when
Sun StorEdge RAID Manager 6.2.21 Release Notes
Sun StorEdge RAID Manager 6.2.21 Release Notes formicrosoftwindowsnt Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-6890-11 November
Media Changer/Recorder VGP-XL1B. Safety Information
Media Changer/Recorder VGP-XL1B Safety Information Notice 2006 Sony Electronics Inc. Reproduction in whole or in part without written permission is prohibited. All rights reserved. This manual and the
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
USER GUIDE. For more information visit www.caldigit.com
USER GUIDE For more information visit www.caldigit.com Table of Contents Section 1 : General Information Introduction 3 General Use Warnings 3 Safety Warnings 3 System Requirements 4 In the Box 4 Thunderbolt
DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide
DSA E-Series E2600, DE1600, DE6600 en Storage System Site Preparation Guide DSA E-Series Table of Contents en 3 Table of contents 1 About This Guide 5 2 Specifications of the E2600 Controller-Drive Tray
M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013
M3 ORANGE Snap-On User Guide Product Model: A-SNO-ATYP-060-R00 Compatible Device: M3 ORANGE Version 2.2 Released in March 2013 Contents Copyright and Agreement... 3 Notice. 4 Warnings and Cautions for
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
15-INCH TFT-LCD MONITOR
15-INCH TFT-LCD MONITOR 15RTV INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. SAFETY INSTRUCTION.2-3 CAUTIONS....4 FCC RF INTERFERENCE STATEMENT.5
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
ASUS Miracast Dongle E-MANUAL E8741
E-MANUAL E8741 E8741 First Edition November 2013 COPYRIGHT INFORMATION No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in
Installation Instructions
Installation Instructions ControlNet PCI Communication Interface Card Catalog Number 9904-PCIC This document describes how to install the 9904-PCIC ControlNet TM communication interface card. Topic: Page:
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 0735 December 2004 Copyright 2004 Sun Microsystems,
Series 4000. Installation Guide Internal AC Outlet Option Kit
Installation Guide Internal AC Outlet Option Kit Series 4000 Instructions for installing the internal AC outlet option in the Series 4000 badge timeclock Document Part Number: 4702573-002 Document Revision:
Cisco TelePresence MCU 4500 Series safety and compliance information
Cisco TelePresence MCU 4500 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information
M2M Cellular Signal Amplifier
CSB.01 M2M Cellular Signal Amplifier Operator s Manual and Installation Guide www.taoglas.com Designed & Manufactured in The U.S.A. Contents 1. Overview 3 2. Parts List 3 3. Installation Guide 4 4. Installation
SECTION 7 - REPAIR/REPLACEMENT PROCEDURES
SECTION 7 - REPAIR/REPLACEMENT PROCEDURES INTRODUCTION Although the modular power system is designed to give long, troublefree service, some components may need to be replaced periodically. This section
Technical Support. Support Information
Technical Support Please refer to the Support Information card that shipped with your product. By registering your product at www.netgear.com/register, we can provide you with faster expert technical support
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
User guide. Stereo Bluetooth Headset SBH80
User guide Stereo Bluetooth Headset SBH80 Contents Introduction...3 Function overview...3 Hardware overview...3 Basics...5 Charging the battery...5 Battery status...5 Turning the headset on and off...5
16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide
16-port Gigabit Switch 10/100/1000 Mbps GS116 Installation Guide Introduction The NETGEAR 16-port Gigabit Switch Model GS116 provides you with a low-cost, reliable, high-performance switch to connect up
Quick-Start Guide. Arrival Sensor
Quick-Start Guide Arrival Sensor Meet your Arrival Sensor The Arrival Sensor lets you stay connected to people, pets, and cars by sending you a push notification when they arrive and leave home. How to
alkaline fisher-price.com
Y6965 BMD91 Please keep this instruction sheet for future reference, as it contains important information. Requires three AA (LR6) alkaline batteries (not included) for operation. Adult assembly is required.
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
PEARL Portable Reading Camera
PEARL Portable Reading Camera Quick Start Guide Freedom Scientific, Inc. 440528-001 Rev. D Freedom Scientific, Inc., 11800 31 st Court North, St. Petersburg, Florida 33716-1805, USA www.freedomscientific.com
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 Installation Guide Introduction The NETGEAR 5-Port Gigabit Ethernet Switch Model GS105 provides you with a low-cost, reliable, high-performance switch
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
Mini Speaker. Printed in China Part No. 480-919-P Version D. CWA BT300 Product Information Guide
Mini Speaker Printed in China Part No. 480-919-P Version D CWA BT300 Product Information Guide IMPORTANT To get the full capability of your new Cobra Airwave Mini, please read this manual. It's more than
How To Set Up An Ecm Display On A D210 (D210) (D2) (Ecm) (Emc) (Mcd) (Power Supply) (Mm) (Camellom) (Ios)
English Customer Display DM-D210 Installation Manual 401285101 CAUTIONS This document shall apply only to the product(s) identified herein. No part of this document may be reproduced, stored in a retrieval
MITSUBISHI ELECTRIC JET TOWEL HAND DRYER CANNON AIR JET
File No. NJNE3737D MITSUBISHI ELECTRIC JET TOWEL HAND DRYER MODEL: JT-SB216ESH-W-CE JT-SB216ESH-DG-CE JT-SB216GSN-W-CE JT-SB216GSN-DG-CE CANNON AIR JET MODEL: JT-SB216ESH-W-CH JT-SB216ESH-DG-CH TECHNICAL
User guide. Stereo Bluetooth Headset SBH70
User guide Stereo Bluetooth Headset SBH70 Contents Introduction...3 Function overview...3 Hardware overview...3 Basics...5 Charging the battery...5 Battery and power management...5 Turning the headset
Messager USB Digital Messaging System
Messager USB Digital Messaging System Installation & Users Guide Model # V-9988 Valcom 5614 Hollins Road Roanoke, VA 24019 Support: 1-800-VALCOM1 HQ: 1-540-563-2000 Fax: 1-540-362-9800 www.valcom.com [email protected]
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Product Documentation on the World Wide Web
Hotwire M/SDSL Standalone Termination Units Models 7974-A2, 7975-A2, and 7976-A2 Installation Instructions Document Number 7900-A2-GN11-00 August 2000 Product Documentation on the World Wide Web We provide
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
SMART Board interactive flat panel with appliance Model 8055ie-SMP
Specifications SMART Board interactive flat panel with appliance Model 8055ie-SMP Physical specifications Size 52 3/8" W 32 5/16" H 3 11/16" D (133 cm 82 cm 9.3 cm) (See Physical dimensions on page 7 for
918AC Series System Interface Installation, Operation, and Maintenance Instructions
918AC Series System Interface Installation, Operation, and Maintenance Instructions The 918AC Series is designed to provide a visible and audible alarm. It is an A.C. powered device intended to be located
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200
Linux Device Server IGW/922 with DIL/NetPC ADNP/9200 Hardware Reference SSV Embedded Systems Heisterbergallee 72 D-30453 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: [email protected]
Sun Enterprise 420R Server Product Notes
Sun Enterprise 420R Server Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 806-1082-12 May 2001, Revision A Send comments about
4 Port VGA Video Audio Switch with RS232 control
4 Port VGA Video Audio Switch with RS232 control VS410RVGAA *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,