Model 111 Mass Flow Instruments

Similar documents
PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Gas Mass Flow Control Products

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Typical Aluminum GFM Mass Flow Meter

TELEDYNE HASTINGS INSTRUMENTS

OEM-EP Pressure Controllers

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

Mass Flow Meters & Controllers

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

VSO MAX HP High Flow Proportional Valve

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

TY-FLO Needle Valves

Precision Mass Flow Meters / Controllers for Liquids and Gases

Thermal Mass Flow Meters and Controllers for Gases

Veriflo Pressure Regulators

Models SFP33 & SFP32 Pressure Transmitters

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

4 Posiflow Proportional Solenoid Valves

Battery Powered Digital Mass Flow Meters for Gases

Battery Powered Thermal Mass Flow Meters for Gases

How To Use A Flowmeter

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

Dual Heat Transfer Coils. Catalog 4295 Revised, December

Aera Transformer Digital Mass Flow Products. Transform your process with greater flexibility and lower cost of ownership

NDP-50 Specifications

Micro Motion 3098 Gas Specific Gravity Meter

Digital inductive conductivity transmitter

Battery Powered Thermal Mass Flow Meters for Gases

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

COMBIMASS. Technical Data COMBIMASS eco-bio +

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Low Frequency Velocity Sensor

Airflow Sensors Line Guide

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

1805 Series Relief Valves

Thermal Mass Flow Meter (Series MST)

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Precision Mass Flow Metering For CVD Applications.

Fundamentals of Mass Flow Control

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Sierra 820 Series Top-Trak ª Mass Flow Meters. Instruction Manual Part Number IM-82 Revision C 06-99

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Aera FC-DR980 Digital Mass Flow Products

The Unique Accelabar Flow Meter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Fisher 657 and 667 Diaphragm Actuators

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Electronic Flow Switches

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Laminar Flow Elements

Variable Area Flowmeters

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Plastic tube flowmeters Series PT/PS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Baumann Way Bronze or Stainless Steel Control Valve

In-Line Electronic Flow Switches

PRODUCT PROFILE FEATURES

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Turbine Flow Sensor Series VTR

O C M III. Open Channel Flow Monitor

Model 5850E Mass Flow Controller

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

HIH-4000 Series Humidity Sensors

General Purpose ph/orp Sensors

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Relative and absolute pressure switch type 529

Micro Motion Model D and DL Coriolis Flow and Density Meters

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Instruction Manual. T3111 T3111L T3111P T3111Ex

Contents. Document information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Powers Controls TH 192 S Single Temperature Room Thermostat

Rosemount 333 HART Tri-Loop

Accumulators and Receivers

Ultra-Filter. Compressed Air Filter. DF Series

LED...A Q Series Sealed High-Intensity

Submersion/Insertion Toroidal Sensor

Electronic Pressure Switch EDS 3000

Rosemount 333 HART Tri-Loop

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

289 Series Spring-Loaded Relief Valves

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Transcription:

111 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flowmeters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas flow applications in the analytical, process, chemical/ petrochemical, environmental, biopharmaceutical and research markets. The 100 and 200 series are the lastest evolution of the original Porter Mass Products. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Meters are available for applications where flow measurement only is required. SPECIFICATIONS: Capacity: Any range from 0-5 SCCM to 0-10 SLPM (nitrogen equivalent). Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds Accuracy and Linearity: ±1% full scale Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control) Ambient and Operating Temperature Range: -10 to 70 C ( ±14 to 158 F) Maximum Operating Pressure: 1500 PSIG Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / C of zero ±0.05% of reading/ C of span Pressure Coefficent (per SEMI E28-92 Total Calibration Effect): ± 0.1%/atmosphere typical using nitrogen (N 2 ) Mounting Orientation: Attitude insensitive Warm-up Time: 10 minutes External Electrical Connector: Nine (9)- pin D-connector Weight (approximate): 0.9 lbs Power Supply Requirements: (Current consumption <45 madc): Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc Current loop models: +15 (±5%) or +24 (±15%) Vdc Setpoint Input/ Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load 0-10 Vdc/0-10 Vdc (3K ohm minimum load 1-5 Vdc/1-5 Vdc (2K ohm minimum load 4-20 madc/4-20madc (refer to load resistance values below) Load resistance values for 4-20 masc flow signal output: 0-450 ohm for 6.5-15 Vdc loop supply 200-750 ohm for 15-30 Vdc loop supply

MATERIALS OF CONSTRUCTION ORDERING INFORMATION Body: 316 Stainless Steel Sensor Assembly: 316L Stainless Steel Elastomers (O-rings and Valve Seat): Buna N, EPDM, Kalrez, Neoprene or Viton Process Connections: 316 Stainless Steel Kalrez and Viton are the property of their respective owners Specifications subject to change To order, please specify: number of output signal Elastomer material Process connection size and type capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Additional accessories required DIMENSIONAL DATA Dimensions shown in inches Process Connection Size X Dimension & 1/8 Compression 4.027 1/4 Compression 4.027 3/8 Compression 4.327 1/4 CPI 4.207 3/8 CPI 4.327 1/4 A-Lok 4.207 3/8 A-Lok 4.327 1/4 MMGFS (2) 4.067

MODEL NUMBER AND DESCRIPTION 111 - F K A S V C AA Example: - Assembly/Calibration Features 111 AA: Factory Standard Revision Level F: Current Revision PC Board Electrical Connector K: Nine (9)-Pin D Setpoint Signal/Output Signal A: 0-5 Vdc B: 4-20 madc (sinking) D: 1-5 Vdc E: 0-10 Vdc H: 4-20 madc (sourcing) Body Material S: 316 Stainless Steel A-LOK, CPI, UltraSeal, VacuSeal - Seal Parker Hannifin Corp. (1) MORFS = Male O-Ring Face Seal (2) MMGFS = Male Metal Gasket Face Process Connection Size and A 3/8 CPI M 1/4 UltraSeal B 1/8 Compression P 1/4 MMGFS (2) C 1/4 Compression Q 3/8 MMGFS (2) D 3/8 Compression R 3/8 UltraSeal E 1/2 Compression S 1/2 MMGFS (2) H 10 mm Compression U 3/8 A-LOK I 1/4 CPI W 6 mm Compression J 1/4 MORFS (1) X No Connections K 3/8 MORFS (1) Y 1/4 A-LOK L 1/2 MORFS (1) Z Special Connections Elastomers (Valve Seat/O-Rings) B: Buna N E: EPDM K: Kalrez N: Neoprene V: Viton For model number options not shown above, please consult factory OTHER AVAILABLE ANALOG MASS FLOWMETER AND MASS FLOW CONTROLLER MODELS Meters 111 10 1500 2 121 10 3000 2 112 100 1500 2 122 100 3000 2 113 500 1000 2 114 1000 1000 2 2111 10 200 2 3211 10 1000 2 Controllers 201 10 1000 7 261 10 1000 7 221 10 3000 7 251 50 1000 35 202 100 1000 60 222 100 3000 60 202A 100 200 10 203A 500 200 40 204A 1000 200 80 2201 10 200 7 3201/3261 10 1000 7 Note: The flow ranges listed are the minimum and maximum nitrogen (N2) flow ranges available for each given model. Intermediate flow ranges are available. For correct sizing when operating parameters are questionable, please consult the factory. Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA (215) 723-4000/ fax (215) 723-2199 WS-0002 Rev. C 02/12

112 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flowmeters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas flow applications in the analytical, process, chemical/ petrochemical, environmental, biopharmaceutical and research markets. The 100 and 200 series are the lastest evolution of the original Porter Mass Products. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Meters are available for applications where flow measurement only is required. SPECIFICATIONS: Capacity: Any range from 0-10 SLPM to 0-100 SLPM (nitrogen equivalent). Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds Accuracy and Linearity: ±1% full scale Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control) Ambient and Operating Temperature Range: -10 to 70 C ( ±14 to 158 F) Maximum Operating Pressure: 1500 PSIG Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / C of zero ±0.05% of reading/ C of span Pressure Coefficent (per SEMI E28-92 Total Calibration Effect): ± 0.1%/atmosphere typical using nitrogen (N 2 ) Mounting Orientation: Attitude insensitive Warm-up Time: 10 minutes External Electrical Connector: Nine (9)- pin D-connector Weight (approximate): 2.1 lbs Power Supply Requirements: (Current consumption <45 madc): Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc Current +15 (±5%) loop or models: +24 (±15%) Vdc Setpoint Input/ Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load 0-10 Vdc/0-10 Vdc (3K ohm minimum load 1-5 Vdc/1-5 Vdc (2K ohm minimum load 4-20 madc/4-20madc (refer to load resistance values below) Load resistance values for 4-20 masc flow signal output: 0-450 ohm for 6.5-15 Vdc loop supply 200-750 ohm for 15-30 Vdc loop supply

MATERIALS OF CONSTRUCTION ORDERING INFORMATION Body: 316 Stainless Steel Sensor Assembly: 316L Stainless Steel Elastomers (O-rings and Valve Seat): Buna N, EPDM, Kalrez, Neoprene or Viton Process Connections: 316 Stainless Steel Kalrez and Viton are the prpoerty of their respective owners Specifications subject to change To order, please specify: number of output signal Elastomer material Process connection size and type capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Additional accessories required DIMENSIONAL DATA Dimensions shown in inches Process Connection Size X Dimension & 1/4 Compression 4.584 3/8 Compression 4.704 1/4 CPI 4.584 3/8 CPI 4.704 1/4 A-Lok 4.584 3/8 A-Lok 4.704 1/4 MMGFS (2) 4.444

MODEL NUMBER AND DESCRIPTION 112 - F K A S V C AA Example: - Assembly/Calibration Features 112 AA: Factory Standard Revision Level F: Current Revision PC Board Electrical Connector K: Nine (9)-Pin D Setpoint Signal/Output Signal A: 0-5 Vdc B: 4-20 madc (sinking) D: 1-5 Vdc E: 0-10 Vdc H: 4-20 madc (sourcing) Body Material S: 316 Stainless Steel A-LOK, CPI, UltraSeal, VacuSeal - Parker Hannifin Corp. (1) MORFS = Male O-Ring Face Seal (2) MMGFS = Male Metal Gasket Face Seal Process Connection Size and A 3/8 CPI M 1/4 UltraSeal C 1/4 Compression P 1/4 MMGFS (2) D 3/8 Compression Q 3/8 MMGFS (2) E 1/2 Compression R 3/8 UltraSeal H 10 mm Compression S 1/2 MMGFS (2) I 1/4 CPI U 3/8 A-LOK J 1/4 MORFS (1) W 6 mm Compression K 3/8 MORFS (1) X No Connections L 1/2 MORFS (1) Y 1/4 A-LOK Z Special Connections Elastomers (Valve Seat/O-Rings) B: Buna N E: EPDM K: Kalrez N: Neoprene V: Viton For model number options not shown above, please consult factory OTHER AVAILABLE ANALOG MASS FLOWMETER AND MASS FLOW CONTROLLER MODELS Meters 111 10 1500 2 121 10 3000 2 112 100 1500 2 122 100 3000 2 113 500 1000 2 114 1000 1000 2 2111 10 200 2 3211 10 1000 2 Controllers 201 10 1000 7 261 10 1000 7 221 10 3000 7 251 50 1000 35 202 100 1000 60 222 100 3000 60 202A 100 200 10 203A 500 200 40 204A 1000 200 80 2201 10 200 7 3201/3261 10 1000 7 Note: The flow ranges listed are the minimum and maximum nitrogen (N 2 ) flow ranges available for each given model. Intermediate flow ranges are available. For correct sizing when operating parameters are questionable, please consult the factory. Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA (215) 723-4000/ fax (215) 723-2199 WS-0003 Rev. C 02/12

113 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flowmeters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas flow applications in the analytical, process, chemical/ petrochemical, environmental, biopharmaceutical and research markets. The 100 and 200 series are the lastest evolution of the original Porter Mass Products. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Meters are available for applications where flow measurement only is required. SPECIFICATIONS: Capacity: Any range from 0-100 SLPM to 0-500 SLPM (nitrogen equivalent). Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds Accuracy and Linearity: ±1% full scale Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control) Ambient and Operating Temperature Range: -10 to 70 C ( ±14 to 158 F) Maximum Operating Pressure: 1500 PSIG Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / C of zero ±0.05% of reading/ C of span Pressure Coefficent (per SEMI E28-92 Total Calibration Effect): ± 0.1%/atmosphere typical using nitrogen (N 2 ) Mounting Orientation: Attitude insensitive Warm-up Time: 10 minutes External Electrical Connector: Nine (9)- pin D-connector Weight (approximate): 5.2 lbs Power Supply Requirements: (Current consumption <45 madc): Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc Current loop models: +15 (±5%) or +24 (±15%) Vdc Setpoint Input/ Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load 0-10 Vdc/0-10 Vdc (3K ohm minimum load 1-5 Vdc/1-5 Vdc (2K ohm minimum load 4-20 madc/4-20madc (refer to load resistance values below) Load resistance values for 4-20 masc flow signal output: 0-450 ohm for 6.5-15 Vdc loop supply 200-750 ohm for 15-30 Vdc loop supply

MATERIALS OF CONSTRUCTION ORDERING INFORMATION Body: 316 Stainless Steel Sensor Assembly: 316L Stainless Steel Elastomers (O-rings and Valve Seat): Buna N, EPDM, Kalrez, Neoprene or Viton Process Connections: 316 Stainless Steel Kalrez and Viton are property of their respective owners Specifications subject to change To order, please specify: number of output signal Elastomer material Process connection size and type capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Additional accessories required DIMENSIONAL DATA Dimensions shown in inches Process Connection Size X Dimension & 3/8 Compression 5.939 1/2 Compression 6.159 1/2 CPI 6.159 1/2 A-Lok 6.159 3/8 A-Lok 4.704 3/8 & 1/2 MMGFS (2) 6.179

MODEL NUMBER AND DESCRIPTION 113 - F K A S V C AA Example: - Assembly/Calibration Features 113 AA: Factory Standard Revision Level F: Current Revision PC Board Electrical Connector K: Nine (9)-Pin D Setpoint Signal/Output Signal A: 0-5 Vdc B: 4-20 madc (sinking) D: 1-5 Vdc E: 0-10 Vdc H: 4-20 madc (sourcing) Body Material S: 316 Stainless Steel Process Connection Size and D 3/8 Compression Q 3/8 MMGFS (2) E 1/2 Compression S 1/2 MMGFS (2) F 1/2 CPI T 1/2 UltraSeal G 3/4 Compression V 1/2 A-LOK K 3/8 MORFS (1) X No Connections L 1/2 MORFS (1) Z Special Connections Elastomers (Valve Seat/O-Rings) B: Buna N E: EPDM K: Kalrez N: Neoprene V: Viton A-LOK, CPI, UltraSeal, VacuSeal - Parker Hannifin Corp. (1) MORFS = Male O-Ring Face Seal (2) MMGFS = Male Metal Gasket Face Seal For model number options not shown above, please consult factory OTHER AVAILABLE ANALOG MASS FLOWMETER AND MASS FLOW CONTROLLER MODELS Meters 111 10 1500 2 121 10 3000 2 112 100 1500 2 122 100 3000 2 113 500 1000 2 114 1000 1000 2 2111 10 200 2 3211 10 1000 2 Controllers 201 10 1000 7 261 10 1000 7 221 10 3000 7 251 50 1000 35 202 100 1000 60 222 100 3000 60 202A 100 200 10 203A 500 200 40 204A 1000 200 80 2201 10 200 7 3201/3261 10 1000 7 Note: The flow ranges listed are the minimum and maximum nitrogen (N 2 ) flow ranges available for each given model. Intermediate flow ranges are available. For correct sizing when operating parameters are questionable, please consult the factory. Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA (215) 723-4000/ fax (215) 723-2199 WS-0004 Rev. C 02/12

114 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flowmeters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas flow applications in the analytical, process, chemical/ petrochemical, environmental, biopharmaceutical and research markets. The 100 and 200 series are the lastest evolution of the original Porter Mass Products. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Meters are available for applications where flow measurement only is required. SPECIFICATIONS: Capacity: Any range from 0-1000 SLPM to 0-5000 SLPM (nitrogen equivalent). Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds Accuracy and Linearity: ±1.5% full scale Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control) Ambient and Operating Temperature Range: -10 to 70 C ( ±14 to 158 F) Maximum Operating Pressure: 1500 PSIG Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / C of zero ±0.05% of reading/ C of span Pressure Coefficent (per SEMI E28-92 Total Calibration Effect): ± 0.1%/atmosphere typical using nitrogen (N 2 ) Mounting Orientation: Attitude insensitive Warm-up Time: 10 minutes External Electrical Connector: Nine (9)- pin D-connector Weight (approximate): 6.6 lbs Power Supply Requirements: (Current consumption <45 madc): Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc Current loop models: +15 (±5%) or +24 (±15%) Vdc Setpoint Input/ Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load 0-10 Vdc/0-10 Vdc (3K ohm minimum load 1-5 Vdc/1-5 Vdc (2K ohm minimum load 4-20 madc/4-20madc (refer to load resistance values below) Load resistance values for 4-20 masc flow signal output: 0-450 ohm for 6.5-15 Vdc loop supply 200-750 ohm for 15-30 Vdc loop supply

MATERIALS OF CONSTRUCTION ORDERING INFORMATION Body: 316 Stainless Steel Sensor Assembly: 316L Stainless Steel Elastomers (O-rings and Valve Seat): Buna N, EPDM, Kalrez, Neoprene or Viton Process Connections: 316 Stainless Steel Kalrez and Viton are property of their respective owners Specifications subject to change To order, please specify: number of output signal Elastomer material Process connection size and type capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Additional accessories required DIMENSIONAL DATA Dimensions shown in inches Process Connection Size X Dimension & 1/2 Compression 7.594 3/4 Compression 7.914 1/2 CPI 7.594 1/2 A-LOK 7.594 3/8 & 1/2 MMGFS (2) 7.614

MODEL NUMBER AND DESCRIPTION 114 - F K A S V C AA Example: - Assembly/Calibration Features 114 AA: Factory Standard Revision Level F: Current Revision PC Board Electrical Connector K: Nine (9)-Pin D Setpoint Signal/Output Signal A: 0-5 Vdc B: 4-20 madc (sinking) D: 1-5 Vdc E: 0-10 Vdc H: 4-20 madc (sourcing) Body Material S: 316 Stainless Steel Process Connection Size and E 1/2 Compression Q 3/8 MMGFS (2) F 1/2 CPI S 1/2 MMGFS (2) G 3/4 Compression T 1/2 UltraSeal K 3/8 MORFS (1) V 1/2 A-LOK L 1/2 MORFS (1) X No Connections Z Special Connections Elastomers (Valve Seat/O-Rings) B: Buna N E: EPDM K: Kalrez N: Neoprene V: Viton A-LOK, CPI, UltraSeal, VacuSeal - Parker Hannifin Corp. (1) MORFS = Male O-Ring Face Seal (2) MMGFS = Male Metal Gasket Face Seal For model number options not shown above, please consult factory OTHER AVAILABLE ANALOG MASS FLOWMETER AND MASS FLOW CONTROLLER MODELS Meters 111 10 1500 2 121 10 3000 2 112 100 1500 2 122 100 3000 2 113 500 1000 2 114 1000 1000 2 2111 10 200 2 3211 10 1000 2 Controllers 201 10 1000 7 261 10 1000 7 221 10 3000 7 251 50 1000 35 202 100 1000 60 222 100 3000 60 202A 100 200 10 203A 500 200 40 204A 1000 200 80 2201 10 200 7 3201/3261 10 1000 7 Note: The flow ranges listed are the minimum and maximum nitrogen (N 2 ) flow ranges available for each given model. Intermediate flow ranges are available. For correct sizing when operating parameters are questionable, please consult the factory. Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA (215) 723-4000/ fax (215) 723-2199 WS-0005 Rev. C 02/12

121 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flowmeters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas flow applications in the analytical, process, chemical/ petrochemical, environmental, biopharmaceutical and research markets. The 100 and 200 series are the lastest evolution of the original Porter Mass Products. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Meters are available for applications where flow measurement only is required. SPECIFICATIONS: Capacity: Any range from 0-5 SCCM to 0-10 SLPM (nitrogen equivalent). Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds Accuracy and Linearity: ±1% full scale Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control) Ambient and Operating Temperature Range: -10 to 70 C ( ±14 to 158 F) Maximum Operating Pressure: 3000 PSIG Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / C of zero ±0.05% of reading/ C of span Pressure Coefficent (per SEMI E28-92 Total Calibration Effect): ± 0.1%/atmosphere typical using nitrogen (N 2 ) Mounting Orientation: Attitude insensitive Warm-up Time: 10 minutes External Electrical Connector: Nine (9)- pin D-connector Weight (approximate): 0.9 lbs Power Supply Requirements: (Current consumption <45 madc): Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc Current loop models: +15 (±5%) or +24 (±15%) Vdc Setpoint Input/ Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load 0-10 Vdc/0-10 Vdc (3K ohm minimum load 1-5 Vdc/1-5 Vdc (2K ohm minimum load 4-20 madc/4-20madc (refer to load resistance values below) Load resistance values for 4-20 masc flow signal output: 0-450 ohm for 6.5-15 Vdc loop supply 200-750 ohm for 15-30 Vdc loop supply

MATERIALS OF CONSTRUCTION ORDERING INFORMATION Body: 316 Stainless Steel Sensor Assembly: 316L Stainless Steel Elastomers (O-rings and Valve Seat): Buna N, EPDM, Kalrez, Neoprene or Viton Process Connections: 316 Stainless Steel Kalrez and Viton are property of their respective owners Specifications subject to change To order, please specify: number of output signal Elastomer material Process connection size and type capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Additional accessories required DIMENSIONAL DATA Process Connection Size X Dimension & 1/2 Compression 7.594 3/4 Compression 7.914 1/2 CPI 7.594 1/2 A-Lok 7.594 3/8 & 1/2 MMGFS (2) 7.614 Dimensions shown in inches

MODEL NUMBER AND DESCRIPTION 121 - F K A S V C AA Example: - Assembly/Calibration Features 121 AA: Factory Standard Revision Level F: Current Revision PC Board Electrical Connector K: Nine (9)-Pin D Setpoint Signal/Output Signal A: 0-5 Vdc B: 4-20 madc (sinking) D: 1-5 Vdc E: 0-10 Vdc H: 4-20 madc (sourcing) Body Material S: 316 Stainless Steel A-LOK, CPI, UltraSeal, VacuSeal - Parker Hannifin Corp. (1) MORFS = Male O-Ring Face Seal (2) MMGFS = Male Metal Gasket Face Seal Process Connection Size and A 3/8 CPI M 1/4 UltraSeal B 1/8 Compression P 1/4 MMGFS (2) C 1/4 Compression Q 3/8 MMGFS (2) D 3/8 Compression R 3/8 UltraSeal E 1/2 Compression S 1/2 MMGFS (2) H 10 mm Compression U 3/8 A-LOK I 1/4 CPI W 6 mm Compression J 1/4 MORFS (1) X No Connections K 3/8 MORFS (1) Y 1/4 A-LOK L 1/2 MORFS (1) Z Special Connections Elastomers (Valve Seat/O-Rings) B: Buna N E: EPDM K: Kalrez N: Neoprene V: Viton For model number options not shown above, please consult factory OTHER AVAILABLE ANALOG MASS FLOWMETER AND MASS FLOW CONTROLLER MODELS Meters 111 10 1500 2 121 10 3000 2 112 100 1500 2 122 100 3000 2 113 500 1000 2 114 1000 1000 2 2111 10 200 2 3211 10 1000 2 Controllers 201 10 1000 7 261 10 1000 7 221 10 3000 7 251 50 1000 35 202 100 1000 60 222 100 3000 60 202A 100 200 10 203A 500 200 40 204A 1000 200 80 2201 10 200 7 3201/3261 10 1000 7 Note: The flow ranges listed are the minimum and maximum nitrogen (N 2 ) flow ranges available for each given model. Intermediate flow ranges are available. For correct sizing when operating parameters are questionable, please consult the factory. Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA (215) 723-4000/ fax (215) 723-2199 WS-0006 Rev. C 02/12

122 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flowmeters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas flow applications in the analytical, process, chemical/ petrochemical, environmental, biopharmaceutical and research markets. The 100 and 200 series are the lastest evolution of the original Porter Mass Products. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Meters are available for applications where flow measurement only is required. SPECIFICATIONS: Capacity: Any range from 0-10 SLPM to 0-100 SLPM (nitrogen equivalent). Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds Accuracy and Linearity: ±1% full scale Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control) Ambient and Operating Temperature Range: -10 to 70 C ( ±14 to 158 F) Maximum Operating Pressure: 3000 PSIG Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / C of zero ±0.05% of reading/ C of span Pressure Coefficent (per SEMI E28-92 Total Calibration Effect): ± 0.1%/atmosphere typical using nitrogen (N 2 ) Mounting Orientation: Attitude insensitive Warm-up Time: 10 minutes External Electrical Connector: Nine (9)- pin D-connector Weight (approximate): 2.1 lbs Power Supply Requirements: (Current consumption <45 madc): Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc Current loop models: +15 (±5%) or +24 (±15%) Vdc Setpoint Input/ Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load 0-10 Vdc/0-10 Vdc (3K ohm minimum load 1-5 Vdc/1-5 Vdc (2K ohm minimum load 4-20 madc/4-20madc (refer to load resistance values below) Load resistance values for 4-20 masc flow signal output: 0-450 ohm for 6.5-15 Vdc loop supply 200-750 ohm for 15-30 Vdc loop supply

MATERIALS OF CONSTRUCTION ORDERING INFORMATION Body: 316 Stainless Steel Sensor Assembly: 316L Stainless Steel Elastomers (O-rings and Valve Seat): Buna N, EPDM, Kalrez, Neoprene or Viton Process Connections: 316 Stainless Steel Kalrez and Viton are property of their respective owners Specifications subject to change To order, please specify: number of output signal Elastomer material Process connection size and type capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Additional accessories required DIMENSIONAL DATA Dimensions shown in inches Process Connection Size X Dimension & 1/4 Compression 4.584 3/8 Compression 4.704 1/4 CPI 4.584 3/8 CPI 4.704 1/4 A-LOK 4.584 3/8 A-LOK 4.704 1/4 MMGFS (2) 4.444

MODEL NUMBER AND DESCRIPTION 122 - F K A S V C AA Example: - Assembly/Calibration Features 122 AA: Factory Standard Revision Level F: Current Revision PC Board Electrical Connector K: Nine (9)-Pin D Setpoint Signal/Output Signal A: 0-5 Vdc B: 4-20 madc (sinking) D: 1-5 Vdc E: 0-10 Vdc H: 4-20 madc (sourcing) Body Material S: 316 Stainless Steel A-LOK, CPI, UltraSeal, VacuSeal - Parker Hannifin Corp. (1) MORFS = Male O-Ring Face Seal (2) MMGFS = Male Metal Gasket Face Seal For model number options not shown above, please consult factory Process Connection Size and A 3/8 CPI M 1/4 UltraSeal C 1/4 Compression P 1/4 MMGFS (2) D 3/8 Compression Q 3/8 MMGFS (2) E 1/2 Compression R 3/8 UltraSeal H 10 mm Compression S 1/2 MMGFS (2) I 1/4 CPI U 3/8 A-LOK J 1/4 MORFS (1) W 6 mm Compression K 3/8 MORFS (1) X No Connections L 1/2 MORFS (1) Y 1/4 A-LOK Z Special Connections Elastomers (Valve Seat/O-Rings) B: Buna N E: EPDM K: Kalrez N: Neoprene V: Viton OTHER AVAILABLE ANALOG MASS FLOWMETER AND MASS FLOW CONTROLLER MODELS Meters 111 10 1500 2 121 10 3000 2 112 100 1500 2 122 100 3000 2 113 500 1000 2 114 1000 1000 2 2111 10 200 2 3211 10 1000 2 Controllers 201 10 1000 7 261 10 1000 7 221 10 3000 7 251 50 1000 35 202 100 1000 60 222 100 3000 60 202A 100 200 10 203A 500 200 40 204A 1000 200 80 2201 10 200 7 3201/3261 10 1000 7 Note: The flow ranges listed are the minimum and maximum nitrogen (N 2 ) flow ranges available for each given model. Intermediate flow ranges are available. For correct sizing when operating parameters are questionable, please consult the factory. Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA (215) 723-4000/ fax (215) 723-2199 WS-0007 Rev. C 02/12

2200 Series Mass Instruments Precise & Affordable Mass Control The Porter 2200 Series Mass Instruments bring a new dimension to affordable mass flow control. Series 2200 utilizes the same proven thermal sensor assembly, control circuitry and unique laminar flow elements found in the standard Porter mass flow products. 2201 includes the Porter EPC proportional control valve, the same valve assembly used by many analytical instrument manufacturers for accurate gas flow control. This results in mass flow instruments that are affordable without compromising precision, control integrity or reliability. Materials of Construction Body Aluminum Valve Base (Body) Aluminum Orifice Brass ( 2201) Valve Components (Wetted) Stainless Steel ( 2201) Elastomers (O-rings and Valve Seat) Buna N, EPDM, Neoprene or Viton Nickel-plated brass Process (inlet) and aluminum Connections (outlet-integral to body) Viton is a registered trademark of DuPont Dow Elastomers L.L.C. Contact Information: Specifications Capacity Response Time Accuracy and Linearity Repeatability Rangeability (Control Range) Ambient & Operating Temperature Range Maximum Operating Pressure Temperature Coefficient Maximum flows from 40 SCCM to 10 SLPM (based on nitrogen [N 2 ] @ 70 F & 5 PSIG) 3 to 4 seconds ±2% full scale Within ±0.2% full scale at any constant temperature within operating temperature range 50:1 (2%-100% full scale) -10 C to 70 C (+14 F to 158 F) 200 PSIG ±0.1%/ C Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 phone 215 723 4000 fax 215 723 2199 Industrial@parker.com www.parker.com Pressure Coefflcient ±0.1%/atmosphere typical using N 2 Setpoint Input/ Signal Output 0-5 Vdc (2K ohm minimum load resistance for flow signal output) Power Supply Requirements (current consumption <250 madc) +12 (±5%) or +15 (±10%) Vdc +24 Vdc (used for 4-20 madc PCB) Mounting Orientation Attitude insensitive Warm-up Time External Electrical Connector Inlet/Outlet Process Connections 10 minutes Nine (9)-pin D-connector 1/8" female NPT

Dimensions 2211 2201 Ordering Information To order, please specify: capacity Gas type Operating temperature Inlet (supply) pressure Outlet pressure Calibration standard (i.e. 0 C, 20 C, 21.1 C or 25 C) Elastomer material Additional accessories required (e.g., interface module, interconnecting cable assembly, etc.) 2201 A A A V C 1 AA Basic Number 2211 Mass meter 2201 Mass Controller *Setpoint, valve orifice and seat applicable to 2201 only Revision A Factory Specified Body Orifice*/ Inlet Adapter Materials A Aluminum/Brass/Brass (nickel-plated) Setpoint Signal*/Output Signal A 0-5 Vdc/ 0-5 Vdc B 0-5 Vdc/4-20 madc (sinking) (add $50 for 4-20mAdc output signal) H 4-20 madc/ 4-20 madc (sourcing) (add $50 for 4-20 madc output signal) J 4-20 madc/4-20 madc (sinking) (add $50 for 4-20 madc output signal) Elastomer Material (O-Rings/Valve Seat*) B Buna N/Buna N E EPDM/EPDM N Neoprene/Neoprene V Viton /Viton WARNING USER RESPONSIBILITY Valve Designator (Factory Specified, based on flow and pressures) Use X for model 2211 Inlet & Outlet Process Connections 1 1/8" Female NPT 2 1/8" Compression Fitting 3 1/4" Compression Fitting Customer Application AA (Factory Specified) Example: 2201AAAVC1AA This example part number describes a 2201 model mass flow controller, factory revision A, with 0-5 Vdc setpoint and output signals, Viton elastomers and 1/8" female NPT inlet and outlet process connections. FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. 2011 Parker Hannifin Corporation Bulletin FM-918 Rev G Dec 2011