Thermal Mass Flow Meter (Series MST)



Similar documents
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

For Multi-Parameter Meters see mvx

FCI ST75 Series Flow Meters

COMBIMASS. Technical Data COMBIMASS eco-bio +

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Micro Motion 3098 Gas Specific Gravity Meter

Thermatel Model TA1 Mass Flow Transmitter

Immersible Thermal Gas Mass Flow Meter FeaTures DescrIpTIon

The Unique Accelabar Flow Meter

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Take total control of your HVAC system with cost-saving flow and thermal energy meters

How To Use A Ds340 (Dsp)

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Open channel & partially filled pipe Ultrasonic flow meters

F-5100 Inline Thermal Mass Flow Meter Installation and Operation Guide

Electronic Flow Switches

QuadraTherm 640i/780i HIGH ACCURACY : FOUR-SENSOR : MASS FLOW METER

AYSIX-SAGE GAS MASS FLOW METERS FOR INDUSTRY

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Regards from the Team at Rheology Solutions.

PIEZOMETER AIRFLOW MEASURING RING

Turbine Flowmeters for Gas Applications

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

TELEDYNE HASTINGS INSTRUMENTS

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

In-Line Electronic Flow Switches

Battery Powered Digital Mass Flow Meters for Gases

Centro-Matic Automatic Lubrication Systems System Controls

API Marine. BMS Presentation. Ballast Measurement Systems

Micro Motion Model D and DL Coriolis Flow and Density Meters

T U R B I N E G A S M E T E R

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

Typical Aluminum GFM Mass Flow Meter

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Plastic tube flowmeters Series PT/PS

Sanitary Type Electronic Flow Switches

Battery Powered Thermal Mass Flow Meters for Gases

Laminar Flow Elements

Gas Mass Flow Control Products

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Heating Cable. Construction

Mass Flow Meter Product Guide

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Series DFMT Digital Paddlewheel Flowmeter

Thermal Dispersion Mass Flow

Model 111 Mass Flow Instruments

SITRANS F flowmeters SITRANS F M

SAGE GAS MASS FLOW METERS

Thermal Mass Flow Meters and Controllers for Gases

How To Use A Flowmeter

OPTIMASS 1400 Technical Datasheet

3DLevelScanner II TECHNICAL DATA SHEET

Battery Powered Thermal Mass Flow Meters for Gases

Micro Motion 7829 Visconic Viscosity Meter

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Heating, air-conditioning, cooling

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Temperature & Humidity SMS Alert Controller

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

VSO MAX HP High Flow Proportional Valve

Mass Flow Meters & Controllers

Electronic Control Devices The European Product Catalogue 2007

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

PRODUCT PROFILE FEATURES

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

Thermal Mass Flow Meters

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

O C M III. Open Channel Flow Monitor

OPTIMASS 6000 Technical Datasheet

IMVIB. Online vibration monitoring for Ariel compressors

Buckeye Detection Systems Fixed Detection Systems Application Survey

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

Technical Data Sheet. 3DLevelScanner

LED...A Q Series Sealed High-Intensity

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications

Electronic Control Devices The European Product Catalogue 2007

The. Hoffer Collection. Perfecting Measurement " A powerful source of Turbine Flowmeters and Electronics for a wide range of flow applications.

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Turbine Flow Sensor Series VTR

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

IFC 070 Technical Datasheet

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Transcription:

Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant temperature differential technology and is able to measure gas flow in the range between 0 and 160 NMPS. 100% Customer Satisfaction Because neither temperature nor pressure measurement is required, MST series reduces installation cost and vastly improves system accuracy. The meter is easily installed or retrofitted with minimum downtime and provides superior, long-term process productivity and easy serviceability. MST series can have either inline sensor or insertion sensor. The inline sensor size ranges from 1 (25mm) to 12 (300mm) with either NPT thread connection or flange connection. The insertion sensors are available from 1 (25 mm) and above with the sensor mounting option of either compression fitting or flange. The indicator/transmitter provides a 4-20mA, pulse, RS- 485, HART, alarm, etc. Main Features Thermal Mass Flow Meter (Series MST) THERMAL MASS FLOWMETER Can measure gas/air flow without pressure or temperature compensation It can measure mass flow and also volume flow. No moving parts High accuracy of 1.0% of reading/1.5% FS ±0.5 Reading Wide turndown ratio of 100:1 Field-programming capability available SUS 316 stainless steel material for sensor body and sensing elements Lightening protection Measuring Principle MST series Thermal Mass Flow Meter utilizes both constant temperature differential (dt) and constant current technologies. The sensor has two elements. The reference RTD measures the gas temperature. The electronics heats the heated element above the gas temperature. It is the job of the electronics to maintain a constant current ( & 300) or a constant dt between the gas temperature and the heated element (). The electronics measures the dt and the current to measure the flow rate. 1

INDICATORS AND SENSORS MST Series Indicator/Transmitter Models Model Description Graphic LCD Indicator with Totalizer Principle: Constant Current Method Graphic Backlight LCD Indicator with Totalizer Principle: Constant Temperature Method Graphic LCD Indicator with Totalizer with Inline Sensor 1 ~12 (25~300mm) Principle: Constant Current Method Only for Air and Nitrogen Gases The indicator/transmitter can be mounted integrated with the sensor or mounted separately by option. Sensors Division Description Connection Pipe Size /Fitting Inline NPT Thread Flange 1 ~ 12 (25 ~ 300mm) with Insertion Sensor 2 ~ 40 (50~1000mm) Insertion Compression Fitting 1 ~ 40 Flange Fitting (25 ~ 1000mm) For insertion type sensors, mounting accessories (such as compression fitting and flange fitting are supplied upon request. with Insertion Sensor 2 ~ 40 (50~1000mm) with Insertion Sensor 1 ~ 12 (25~300mm) 2

Technical Specifications SPECIFICATIONS Technolog y & Feature Flow Velocity Range Constant Current Method Constant Temperature Method 0.6 ~ 60 Nm/s (Optionally up to 160 Nm/s) Constant Current Method Special Edition Only for Air and Nitrogen Gases Indicator /Converte r Flow Rate, Temperature, Density, Frequency & Totalizer Graphic LCD Flow Rate & Totalizer 16 x 2 Alphanumeric LCD with Backlight Flow Rate, Totalizer, Velocity & Temperature Graphic LCD Key 3-keys 4-keys 3-keys Output 4-20mA, Frequency, RS- 485 (MODBUS), HART 4-20mA, Pulse, RS-485 & Alarm 4-20mA, Frequency, RS-485 (MODBUS), HART Flow Rate Units Material Max. Pressure Max. Temperat ure Enclosure Power Supply Fixed at the Factory Indicator: -40~ 150 Weather proof (NEMA 4x), IP-65, Ex-proof (Exd IIC T3) Nm3/h, Nm3/m, Kg/d, Kg/hr, Kg/m, Kg/s, SCFM, SCFH, Lb/d, Lb/h, Lb/m, Lb/s, NLPH, NLPM, SLPM, SMPS, NMPS, SFPM Indicator Housing Cast Aluminum, Sensor SUS316 16 barg Sensor: Standard: -40 ~ 121, High-Temperature: 0 ~ 204 Weather proof (NEMA 4x), IP- 65 Fixed at the Factory Indicator: -40~ 150 Weather proof (NEMA 4x), IP-65 24VDC/220VAC 24VDC/220VAC 24VDC Accuracy ±1.5% FS ±0.5 Reading ±1.0% of Reading ±1.5% FS ±0.5 Reading Repeatabi lity ±0.5%, Reading ±0.2%, Full Scale ±0.5%, Reading 3

DIMENSIONS /300 Compression Fitting Flange Fitting 4

DIMENSIONS In-Line Type Flange Connection Screw Connection Remote Configuration Insertion Type Compression Fitting Smart Electronics Cable Gland by Customer Junction Box, Ex-proof Shielded Cable, 5 cond. 18 GA, 100 Ft, max. Compression Fitting, ¾ NPT Remote Configuration 5

Model Selection Guide Model Designator MST###-###-#-##-##/Options Constant-Current Method Thermal Mass Flow Meter Constant-Temperature Method Thermal Mass Flow Meter Constant-Current Method Thermal Mass Flow Meter for N2 Gas and Air Code Pipe Size in mm (Describe the dimensions in case of duct) ### Indicator/Converter Sensor Integral Remote Threaded (NPT Male) Inline Type Flanged (ANSI 150#) Insertion Type Compression Fitting (1/2 or 3/4" NPT) Flanged Fitting I R FT FF IC IF Power Supply Options 220VAC 24VDC HART instead of RS-485 Pressure Input (Built-in, for only) Flow Meter Cleaning for Oxygen P1 P2 HT PI CL We are here for you For further information, visit us at www.maxiflo.co.kr Seil Enterprise Co. Seoul Korea www.maxiflo.co.kr MAXIFLO TM is a registered trademark of Seil Enterprise Co. 6