IQCP GUIDELINES and TEMPLATE FOR GETTING STARTED

Similar documents
Individualized Quality Control Plan (IQCP) Frequently Asked Questions Date: May 5, 2015 (last updated 05/13/2016)

Individualized Quality Control Plan

TEST METHOD VERIFICATION AND VALIDATION

CLIA & Individualized Quality Control Plan (IQCP)

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests

Laboratory Director Responsibilities

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

CHAPTER 13. Quality Control/Quality Assurance

LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency?

Center for Clinical Standards and Quality/Survey & Certification Group

Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate of Waiver

Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD

2009 LAP Audioconference Series. How to Prepare and Comply with Your Quality Management Plan

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

Standards for Laboratory Accreditation

Examples: collecting the right sample on the right patient; labeling the sample accurately;

Using and Maintaining Documents and Records. Finding the information when you need it

Flow Cytometry. CLIA Compliance Manual*

Calibration Verification

State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist

Medical Cannabis Laboratory Approval Program

Antimicrobial Resistance Surveillance

General. What is a laboratory test? What is a waived test?

Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard

Diane Kadidlo MT(ASCP) SBB University of Minnesota Joanna Stanson, M.S. University of Pittsburgh

Answers to Your Questions About Blood Bank Proficiency, Competency and QC Follow Up to April 28, 2016 Webinar

Is Your Lab s Competency Assessment a Competent Assessment?

How to Verify Performance Specifications

Mycoplasma Testing Products & Services. M-175 CELLshipper Mycoplasma Detection Kit (In-house sample preparation and slide fixation)

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

Document and Record Control in a Hospital Clinical Laboratory

CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD

Patient Safety and the Laboratory

SAMPLE. Accuracy in Patient and Sample Identification; Approved Guideline. This guideline describes the essential elements of systems and processes

Checklist. Standard for Medical Laboratory

Chapter 2: Quality Assurance and Legal Issues

CLSI TRAINING COURSES CATALOG

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

LabGuide 71. Incident Management: Developing a Plan

Content Sheet 5-1: Overview of Sample Management

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

United States Department of Agriculture Agricultural Marketing Service, Science & Technology Microbiological Data Program

Incident Management: Developing a Plan

New York State Department of Health Wadsworth Center Clinical Laboratory Reference System Clinical Laboratory Evaluation Program

URINE CULTURES GENERAL PROCEDURE

ISO 14971: Overview of the standard

XL-I 2011: Understanding and Explaining the CAP POCT Checklist: A Tool for Laboratorians to Use With POCT Staff

Hazard/Risk Identification and Control Procedure

Welcome to Implementing Inquirybased Microbial Project. Veronica Ardi, PhD

Laboratory Exercise # 11: Differentiation of the Species Staphylococcus and Streptococcus

ASSURING THE QUALITY OF TEST RESULTS

Assay Qualification Template for Host Cell Protein ELISA

Quality Requirements of a Point of Care Testing Service

PROCEDURES FOR HANDLING OOS RESULTS

Procedure: Quality Assurance Policy Version 5 Quality Assessment Policy Version 3

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

General Information. Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations

Contents. Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions...

AN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189

Prepublication Requirements

Bureau of Clinical Laboratories Quality Assessment Plan

VENTURA COUNTY HEALTH CARE AGENCY INVITES APPLICATIONS FOR: Microbiologist III 1398HCA-14AB (SM) An Equal Opportunity Employer

Lean Strategies Used to Optimize Automation. Why Lean Six Sigma? Laboratory Goals. Decreased TAT. Accurate Results. LEAN Goals.

Working Copy - 1,- / t&,1 r. Responsibilities of the Laboratory Quality Assurance Officer. EffectiveDate: 7/ltl/ l'rritials: tuwt

Good Clinical Laboratory Practice (GCLP) An international quality system for laboratories which undertake the analysis of samples from clinical trials

XV.Quality Assurance in the Blood Bank

UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN

Hemostasis analyzer system

Quality control in dental practice Peter Kivovics DMD, BDS, MDSc, PhD, Chief Dental Officer for Hungary

MEDICAL DEVICE GUIDANCE

Equipment Qualification

Edwin Lindsay Principal Consultant. Compliance Solutions (Life Sciences) Ltd, Tel: + 44 (0) elindsay@blueyonder.co.

Going Beyond Laboratory Automation: Do Less Accomplish More. Swedish Covenant Hospital

Guidance on Risk Assessment and Control

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

CLTAC SUBCOMMITTEE ON CLS EDUCATION AND TRAINING POSITION PAPER

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

Quality Assurance (QA) & Quality Control (QC)

Title: Basic Principles of Risk Management for Medical Device Design

RISK MANAGEMENT POLICY. Version 3

College of American Pathologists Accreditation for Public Health Laboratories

Validation and Calibration. Definitions and Terminology

Quality Assurance Guidelines for Testing Using Rapid HIV Antibody Tests Waived Under the Clinical Laboratory Improvement Amendments of 1988

Quality Management Systems Manual

Audits must be conducted with due concern for employee safety and environmental protection.

MeriCal Quality Profile

PROFICIENCY TESTING. Clinical Laboratory Improvement Amendments (CLIA) DOs and DON Ts. Brochure # 8

CDC-Lipid Standardization Program. Laboratory Data Collection System (LDCS) Instruction Manual

Laboratory Accreditation. Personnel Qualifications. What s New? March 17, 2010

Medical Laboratory Technology Program. Student Learning Outcomes & Course Descriptions with Learning Objectives

Pharmaceutical Wholesaler Site Inspection Checklist

Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI

laboratorymedicine> august 2001> number 8> volume 32

College of American Pathologists Laboratory Accreditation Program. Document Control Management

Medical Technology Training at the University of Technology, Jamaica (UTech) P.Williamson-Munroe PGDE, MSc., BSc. (MT)

Everything you want to know about ISO 15189:2012 Medical Laboratories Requirements for Quality and Competence

Diagnosis of HIV-1 Infection. Estelle Piwowar-Manning HPTN Central Laboratory The Johns Hopkins University

Transcription:

IQCP GUIDELINES and TEMPLATE FOR GETTING STARTED Linda C. Bruno, M.A., MT(ASCP) Director, Microbiology and Molecular Labs ACL Laboratories, Rosemont, IL June 1, 2015

Disclosures - No disclosures 2

IQCP OUTLINE IQCP applications in Microbiology Current and future CMS QC standards for Microbiology Getting started on sample IQCP template 3

GOING AWAY 12/31/2015 Equivalent Quality Control (EQC) Aka: QC performed once every 30 days and any frequency other than each day of patient testing COMING 1/1/2016 Individualized Quality Control Plan (IQCP) Aka: QC frequency will need to be determined based on IQCP Risk Assessment 4

IQCP Applications in Microbiology? 5

Microbiology Test Systems where IQCP May Apply All QC not performed each day of testing for NON-WAIVED tests: ID systems (M50 Streamline), including Yeast ID systems Sensitivity testing (eg Vitek, MicroScan, Etests, Disk diffusion testing) Rapid/Direct antigen kits (eg Rotavirus, RSV, Strep A, Legionella Urinary Antigen, Strep pneumoniae urinary Antigen, Flu) Reagent tests (Refer to current CMS reqs) Exempt Culture Media Rapid Molecular tests (eg Illumigene, BioFire, Cepheid) 6

Let s look what is in CMS/CLIA Standards And What CLSI documents are being DELETED from the Standards 7

Current CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Frequency: Each day of use QC Pos Neg D5473 493.1256 AFB Stains (eg Kinyoun, Ziehl-Neelsen) Yes Yes D5501 493.1261 Beta-lactamase other than Cefinase Yes Yes *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 8

Current CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Frequency: Each time of use QC Pos Neg D5475 493.1256 Fluorescent stains (includes fluorochrome AFB) and immunohistochemical stains Yes Yes *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 9

Current CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Pos QC Frequency: Each new batch, lot #, and shipment D5471 493.1256 (e)(1) Neg Bacitracin Yes Yes Catalase Yes Yes Cefinase Yes Yes Coagulase plasma Yes Yes Germ Tube test Yes No *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 10

Current CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Pos QC Frequency: Each new batch, lot #, and shipment D5471 493.1256 (e)(1) Neg ONPG Yes Yes Optochin Yes Yes Oxidase Yes Yes Spot indole Yes Yes X and V factor strips and disks Yes No *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 11

CLSI M50 being DELETED from CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Frequency: Each new lot # and shipment D5471 493.1256 (e)(1) QC Pos Neg Identification systems Yes Yes Check (systems using two or more substrates or two or more reagents, or a combination) when prepared or opened for positive and negative reactivity of each substrate (includes mycology ID systems) *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 12

DELETED from CMS/CLIA CLSI M50 Quality Control for Commercial Microbial Identification Systems Are you doing Stream-line QC? If so, to continue stream-line QC you will need to do an IQCP 13

CLSI M22 being DELETED from CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing Checks QC Frequency: Each new batch, lot #, and shipment check before or concurrent with initial use D5477 493.1256 (e)(4) Media - Sterility - Ability to support growth - Select or inhibit specific organisms - Produce biochemical response - Document when compromised deterioration *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 14

Deleted from CMS/CLIA CLSI M22 Quality Control for Commercially Prepared Microbiological Culture Media (since 1986) Exempt culture media listed in Table 1B of M22 will require IQCP (eg Blood agar, Thio broth, urease agar, blood culture media, CNA, MacConkey etc) NOTE: CMS does not distinguish between exempt and non-exempt culture media 15

Current CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Frequency: Each week of use QC Pos Neg D5503 493.1261 (a)(2) Gram stain Yes Yes *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 16

Current CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Pos Neg QC Frequency: Each lot # and shipment, and once every 6 months D5505 493.1261 (a)(3) Salmonella and Shigella antisera, streptococcal serotyping systems Yes Yes *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 17

CLSI M100 being DELETED from CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Organisms QC Frequency: Each batch of media AND each lot # and shipment of antimicrobial agents before, or concurrent with initial use D5507 493.1261 (b) Antimicrobial susceptibility test Yes *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 18

CLSI M100 being DELETED from CMS Laboratory Standards *SubPart K - Quality System for Nonwaived Testing QC Organisms QC Frequency: Each day tests are performed, must use appropriate control organisms to check procedure D5507 493.1261 (b)(1) Antimicrobial susceptibility test Yes *CLIA Advance copy-revised Appendix C-Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 19

Deleted from CMS/CLIA CLSI M100 Performance Standards for Antimicrobial Susceptibility Testing All disk diffusion and MIC susceptibility testing with weekly QC will need IQCP Labs performing gradient MIC susceptibility testing with weekly QC will need IQCP 20

CLSI References being DELETED CMS/CLIA Clinical Lab Standards M100 Sensitivity QC M22 Media QC M50 Microbial ID Systems Streamline QC 21

Individualized Quality Control Plan (IQCP) 1 Risk Assessment 2 Quality Control Plan 3 Quality Assessment IQCP 22

Individualized Quality Control Plan (IQCP) 1 Risk Assessment 2 Quality Control Plan 3 Quality Assessment IQCP 23

IQCP Risk Assessment (RA) 1. Risk Assessment: Five components that MUST be covered are: Specimen (collection, transport, integrity, receiving, processing ) Lab Environment (temperature, humidity, power failure ) Testing personnel (training, competency, proficiency testing, staffing ) Reagent/QC (shipping, storage, preparation, expiration date ) Test system (sample failure, reagent failure, software failure, hardware failure..) Test results (transmission of results ) NOTE:May be separated out from Test System 24

RISK ASSESSMENT: Identification of Potential Failures 1 Specimen 2 Environment 3 Testing Personnel Specimen integrity Identify Potential Hazards Factors Operator Function Incorrect Test Results Reagent Integrity QC Organism(s) Instrument QC organism Reported Results 4 Reagents 5 Test System 6 Test Results 25 Pre-analytical Analytical Post-analytical

RA - Specimen Review all policies and procedures relating to: Patient identification Collection containers Specimen collection Specimen rejection criteria Labelling of containers Specimen volume Transport Storage HOW OFTEN WERE THERE ERRORS? AND WHAT WAS SEVERITY OF PATIENT HARM? 26

RA Environment Factors that may affect test system: Temperature review records Humidity review records Ventilation Electric are there power surges? Space If cramped, could test system be compromised? Noise / vibration Water quality does test system require DI water? If so, review those records HOW OFTEN DID ISSUES OCCUR? AND WHAT WAS THE SEVERITY OF PATIENT HARM? 27

RA Testing Personnel Are there records / documentation for: Training checklists for each person trained to perform test? Competency assessment is there documentation for each person performing this test system or assay? Proficiency Testing is there PT for this test system and is there remedial action for unsatisfactory results? Is it reviewed? Staffing HOW OFTEN WERE THERE ISSUES? AND WHAT WAS THE SEVERITY TO PATIENT HARM? 28

RA - Reagents Reagent Integrity: Shipping and storage any documented issues? Expiration dates review policy and procedure any issues? Reagent preparation review policy and procedure any issues? QC any issues? HOW OFTEN WERE THERE ISSUES? AND WHAT WAS THE SEVERITY OF PATIENT HARM? 29

Instrument / Assay: RA Test System Software documentation of installs, validation data afterwards, any issues? Hardware or LIS interface any issues Contamination Maintenance review of all records, any trends or recurring issues? Proper specimen sampling any issues Calibration any issues QC any failures, review of all records HOW OFTEN WERE THERE ISSUES? AND WHAT WAS THE SEVERITY OF PATIENT HARM? 30

RA Test System Also review: Manufacturer s package insert what are the limitations of the test / assay What are the interfering substances? Verification/validation data review, any issues? Physician or client complaints 31

RA Test Results Reported results: Transmission of results to Hospital Information Systems (HIS) Review of released results Clinician feedback HOW OFTEN WERE THERE ISSUES? AND WHAT WAS THE SEVERITY OF PATIENT HARM? 32

RA - Risk Assessment After identifying all potential sources of risk/error for each of the five (5) or six (6) components: determine the Frequency of occurrence and the Possible severity of harm for each risk identified, based on documented records of failure or error 33

RA - Risk Assessment Why do you want to do this? Per CMS To conduct a risk assessment, the laboratory must identify the sources of potential failures and errors for a testing process, and evaluate the frequency and impact of those failures and sources of error. * * CMS Ref: Survey and Certification: 13-54-CLIA, August 16, 2013 34

RA What Determines Frequency of Occurrence and Severity of Harm? Review all failure/error data, how many times in a week, month, year did a particular failure or error occur? Did it cause harm to the patient? Corrective action reports Proficiency Testing corrective action Retraining of personnel Temperature out-of-control records QC failures 35

Determining Risk Frequency of occurrence How often does this error occur? Review all data to determine frequency Severity of harm When error occurred, what was the harm to the patient or possible harm that could be to the patient? 36

Determining Risk Example 4 levels Frequency of Occurrence Unlikely (once /2-3 yrs) Occasional (1/yr) Probable (1/mo) Frequent (1/wk) Severity of Harm Negligible (temporary discomfort) Minor (temporary injury; not requiring medical intervention) Serious (impairment requiring medical intervention) Critical (permanent impairment requiring medical intervention) 37

Determining Risk Example 5 levels Frequency of Occurrence Severity of Harm Rare (once /2-3 yrs) Unlikely (1/yr) Possible (1/mo) Likely (2/mo) Negligible (temporary discomfort) Minor (temporary injury; not requiring medical intervention) Moderate (may require medical intervention) Serious (impairment requiring medical intervention) Almost certain (1/wk) Critical (permanent impairment requiring medical intervention) 38

Probability of harm (Frequency) Risk Matrix from CLSI EP-23 Severity of harm (Impact) Negligible Minor Serious Critical Catastrophic Frequent U U U U U Probable A U U U U Occasional A A A U U Remote A A A U U Improbable A A A A A A = Acceptable risk U = Unacceptable risk 39

Risk Assessment Table The following table is an example of how to present the risk. Table/grid represents each of the five or six components and the identified related risk/error frequency of occurrence and severity of harm Measures to control risk Relevant SOP 40

RISK ASSESSMENT: Identification of Potential Failures 1 Specimen 2 Environment 3 Testing Personnel Specimen Integrity Identify Potential Hazards Factors Operator Function Incorrect Test Results Reagent Integrity QC Organism(s) Instrument QC organism Reported Results 4 Reagents 5 Test System 6 Test Results 41 Pre-analytical Analytical Post-analytical

1 Specimen List each risk identified Risk Assessment Specimen EXAMPLE of TABLE FORMAT Frequency of Occurrence List frequency of occurrence Severity of Harm List degree of severity of harm Measures to control risk List how risk will be controlled Relevant SOP Reference SOP that support control measure Repeat this process for each component and all risks identified under that component UNACCEPTABLE risks must be included in Quality Control Plan ACCEPTABLE risks may be included in the Quality Control Plan at the discretion of the Laboratory Director. 42

Individualized Quality Control Plan (IQCP) 1 Risk Assessment 2 Quality Control Plan 3 Quality Assessment IQCP 43

Quality Control Plan (QCP) Resulting Risk Assessment is then used to develop the Quality Control Plan (QCP) Risks identified as UNACCEPTABLE must be included in QCP and address: How will these risks be controlled? How often does QC need to be performed based on the potential risks identified? What QC material needs to be used? What is the criteria for QC acceptability? 44

Quality Control Plan (QCP) What Is It? Document (or chart/table) that describes practices, resources, and procedures used to control the quality of a test system. Must monitor accuracy and precision of test performance MUST include: number of QC, type of QC, frequency of QC and define criteria for acceptability of QC MUST have Lab Director s review, approval, signature (this cannot be delegated) NOTE: Lab Director is the name on the lab CLIA license 45

Individualized Quality Control Plan (IQCP) 1 Risk Assessment 2 Quality Control Plan 3 Quality Assessment IQCP 46

Quality Assessment - Overview Laboratory must establish a review system for on-going monitoring of effectiveness of their QCP. Monitoring must include at least the following: Specimens Testing personnel Testing environment Test reagents Test system 47

Quality Assessment Overview (cont) When a testing process failure is discovered, lab must conduct and document an investigation to: Identify cause of the failure, its impact on patient care, and make appropriate modifications to their QCP Modifications will need review and approval by Lab Director QCP signed / dated again 48

Individualized Quality Control Plan (IQCP) 1 Risk Assessment 2 QC Plan 3 Quality Assessment IQCP 49

References CLIA Advance copy-revised Appendix C- Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services, Jan 9, 2015 CMS Ref: Survey and Certification: 13-54-CLIA, August 16, 2013 50

THANK YOU 51