MERO Floor Systems - CleanRoom



Similar documents
MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing

Modular Access Floor for Data Center. From Rack to Row to Room to Building

A few inches will give your business room to grow...

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to

User guideline NORTEC sonic

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Morgue refrigeration unit

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

How to secure your property after a disaster

Transformer oil cooler ALFA A02

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

mechanics PP-Profiles Panel Profiles PT-Profiles T-Groove Plates RE-Profiles Rectangular Profiles PU-Profiles Universal Profiles

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Knürr Synergy The New Product Family For Uniform Equipment In Your Control Room. Knürr Technical Furniture

sound reduction systems for commercial, educational and industrial environments

Authorized Dealers Access Floors Limited The Studio 15 Huntsmead Northampton NN3 5HT

HORIZONTAL INSTALLATION

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

FLUID FLOW Introduction General Description

SERVER ROOM CABINET INSTALLATION CONCEPTS

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Technical Data Sheet W13. Edition Knauf Fire Walls

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Roof Curbs, Extensions and Equipment Supports

information information

Knürr Smaract. Knürr Smaract. CompactRack

172 Holesaws Overview Bosch Accessories for Power Tools 09/ Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Accessories for GF and RA machines

UNIVERSAL RAILING, STEEL

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

K17.12 Door closers K17. Doors

CABLE SUPPORT SYSTEMS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Confort 160. Sliding Systems. Sapa Building System

Passive Fire Protection

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

Confort 26. Sliding Systems. Sapa Building System

Linkeo 19" freestanding cabinets

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

Iso Floor Raised Floor System

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

CABINET & ENCLOSURE STANDARD FEATURES MATERIALS APPLICATION N C B C A B I N E T P/N:NCB

Product Catalogue HW-B150H

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

12.1 Schlüter -KERDI-BOARD

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Cable Trays Technical Instructions & Specifications

Plaisance 24. Sliding Systems. Sapa Building System

Rockwool Flexi Insulation Application Guide

Tubular connection elements

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

Fire Barrier Duct Wrap 15A

English version. Raised access floors

How To Build A T7 Rack For Information Technology

Puddle Flange. FRANK Puddle Flange

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05


Embedded Parts Introduction - Anchors

THE IDEAL SOLUTION SHELVING. Sales Telephone: Sales Fax:

Under sill units. Type FSL-B-ZAS

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Structural fire design Eurocode Timber structures

Services Enclosures and Protected Shafts - Maintaining Compartmentation

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

High-speed folding doors. F Series

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Colonnade Security Pipe

SHOT BLAST TECHNOLOGY

HS-Alu-Premium. Curing chambers for the concrete industry in an innovative aluminium version

TARIFF CODE and updates standard

Grilles & Diffusers Series LFP Incorporating

Timber Decks. Technical Note. March 2007

Chapter. Restoration of Damaged Structures

Vitraflex Classic Modular Combination Shower and Changeroom Cubicles (c/w Telescopic Stainless Steel Leg Anchors)

Machine devices, jig devices

YTONG Product list.

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

TruLaser Tube: Optimal tube. and. profile cutting. Machine Tools / Power Tools Laser Technology / Electronics Medical Technology

FRACASSO SCAFFOLDING PS 720

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

BETONYP building boards. The modern way of living.

BLADE S-MAX Cabinet for Blade Server

Transcription:

MERO Floor Systems - CleanRoom Innovative solutions out of one hand Development Access floor Consulting Hollow floor Planning Floor covering and Manufacturing Installation Installation Services Floor systems

Cleanest conditions for your projects MERO-TSK CleanRoom The production of component parts in the field of microelectronics or nanotechnology can only be managed under optimal clean room conditions. In the field of biotechnology sterile environments are an indispensable requirement for successful research and later production. Production and research are subject to permanent changes which should already be taken into consideration during the planning stage of clean rooms. Partitions and media service lines must allow for rapid and economical adjustment to new requirements. The MERO-TSK CleanRoom access floor accommodates all service lines such as special media, water and air, electrical wiring etc. perfectly and allows an effective absorption of used air due to perforated panels. The uniform arrangement of the vent holes guarantees turbulence-free air. The solid substructure and the prefabricated access floor elements guarantee an oscillationfree working. 2

Solid and flexible High demands on the construction The steel construction of the CleanRoom access floor is a solid foundation above the sub floor allowing the transport of heavy equipment. Even without surrounding walls the CleanRoom access floor is forming a self-supporting rigid construction. The lateral stability of the Clean- Room access floor is guaranteed by angles and diagonal bracings preventing the transmission of oscillations. Stable pedestals are permanently fixed to the sub floor. Intermediate braces allow an easy and clear arrangement of media lines. The pedestals are exactly levelled and secured against dynamic forces. The pedestals of the substructure are galvanized and yellow passivated. Machinery which must work absolutely oscillation-free is installed on shock-absorbers. Oscillation areas are separated from the other CleanRoom access floor areas by special profiles. The sub floor is provided with a abrasion-proof sealant before installation which guarantees dust free conditions. Changing conditions require flexible installation and reorganization Research labs or high sensitive production units are subject to permanent optimization and changing requirements. New distribution or redistribution of the floor module is possible at any time even under operating conditions. The permanent underpressure in the CleanRoom area and below the access floor allows to lift the panels whenever needed. Each floor panel can be taken out by a lifting device allowing to retrofit power and service lines quick and easy. 2

Panel types for any field of application Panel type 5 or type 6 with MERO air outlet Floor panels of high density wooden material or fibre-reinforced mineral material. Panel edges are bevelled and protected all round by synthetic trim. Panel underside can be provided with galvanized steel sheet or aluminium foil. Up to 4 air outlets can be installed in one floor panel. The MERO air outlet can be used for a concentrated load up to 5.000 N and can also be supplied with dust basket and air flow control. Panel thickness of wooden material panels: 38 mm Panel thickness of mineral material panels: 36 mm Module: Panel material - Building material class : wooden material B > mineral material A Free airflow of one air outlet = 84 cm 2 Free airflow of four air outlets = 336 cm 2 MERO steel air conditioning panel The MERO air conditioning panel consists of a welded steel profile frame with a perforated covering steel sheet on top. The panel is protected by conductive powder coating. Panel thickness: 44 mm Panel module: Building material class: A (non-combustible) Free cross-section up to 40% possible. MERO aluminium panel The panel consists of ribbed die cast aluminium cut to size by high precision milling machines. The floor covering is simultaneously cut with the aluminium panel which guarantees maximum edge accuracy. Panel thickness: 44 mm Module: Building material class: A (non-combustible) Free cross-section up to 40% possible.

Constant conditions for research and production Clean air by steady air circulation Tests in renowned institutes for air-conditioning technology ascertained that the permeability of an access floor is the optimal solution for the vertical and turbulence-low air flow. Lateral air extraction systems are causing air turbulences and disturbing air flow at the working place. A CleanRoom access floor avoids the swirl up of dust particles and transports them on the shortest way through the perforated floor panels out of the clean room. In order to get a permanent steady air flow panels are equipped with holes of different sizes or air flow control. Protection against static charging All construction parts and equipment of a clean room must be protected against static charging which guarantees the CleanRoom access floor. Dust particles which are brought into the clean room by people or machinery must be conducted out with the permanent air flow to avoid adherence to electrical charged surfaces. Furthermore, product damages caused by static electricity charge must be avoided. The measuring methods and tests for the electrostatic discharge are determined according to DIN EN 1081 or DIN IEC 61340-4-1.

Technical Data*: CleanRoom 1 2 3 4 5 6 7 8 9 *For detailed technical data please see the data sheets of the different types or internet page under www.mero-tsk.de 1. Floor covering 2. Floor panel 3. Gasket 4. Profile Clean 5. Screw 6. Pedestal head 7. Hexagonal nut 8. Tube 9. Pedestal base plate glued to the sub floor (dowelled on request) Steel Aluminium Wood/Mineralmaterial 44 mm ~ 64 kg/m² 44 mm ~ 28 kg/m² 38/36 mm ~ 36 67 kg/m² Panel weight: Panel material: ~ 22 kg/piece Steel construction powder coated ~ 9 kg/piece die casting aluminium ~12 22 kg/piece High density chipboard panel/ fibre-reinforced mineral material Understructure: Module: Pedestal material: Galvanized steel pedestals, aluminium pedestals on request, glued to the sub floor,profiles screwed with pedestal heads ~ 80 1800 mm ~ 80 1800 mm ~ 80 1800 mm Panel: Dimension: Panel thickness: System weight: (without covering, floor height 250 mm) Construction height (without covering) Recommendation: Stringers should generally be used from a floor height of > 500 mm e.g. U-type stringers Diameter of holes: Standard module Different diameters possible Electrostatic: Depending on systems and floor covering Fire protection: Building material class acc. to DIN 4102 T1 A1 A1 B2 / B1 / A2 Thermal conductivity (base material) ~ 50 W/mk ~ 160 W/mk ~ 0,13 0,44 W/mk TÜV certificate since 2005-01-20 For advisory service and further information please do not hesitate to contact us. MERO-TSK International GmbH&Co. KG Floor System Division Lauber Straße 7 D-97357 Prichsenstadt/Germany Phone: +49 (0) 9383/203-351 Fax: +49 (0) 0383/203-629 Email: bodensysteme@ mero-tsk.de Internet: www.mero-tsk.de 02.07 / Clean-Room / Subject to change without further notice Load values: Concentrated load acc. to DIN EN 12825 class 3 6 class 3 6 class 1 6 Nominal load 4.000 N 7.000 N 4.000 N 7.000 N 2.000 N 6.000 N Ultimate load >8.000 N 14.000 N >8.000 N 14.000 N >4.000 N 12.000 N