Thermal, moisture and biological behaviour of natural insulating materials



Similar documents
Energy and Buildings

Post-insulation of cellar ceiling and cellar walls

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

TEXTILE FABRICS AS THERMAL INSULATORS

European technical approval

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

SIP (STRUCTURAL INSULATED PANEL)

Module 3.7. Thermal bridging

Moisture Content in Insulated Basement Walls

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Mold Preventing I nterior System

Mineral fibreglass insulation

Control Mold Through Water Activity Prevent Mold Growth on Building Materials

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions

Rockwool Cladding Roll

Long-Term Hygrothermal Performance of Green Roofs

METHODOLOGY OF LIFE-CYCLE ASSESSMENT OF RC STRUCTURES USING HIGH PERFORMANCE CONCRETE

Embodied Energy of Building Envelopes and its Influence on Cooling Load in Typical Indonesian Middle Class Houses

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

High performance thermal insulation materials

CLT - healthy, solid and cost-efficient

Dubai Municipality Standard DMS 1: Part 5: 2004

Tuula Putus, M.D. Professor in Occupational Health Care and Occupational Medicine, University of Turku, Finland

HEAT TRANSFER ANALYSIS OF COLD STORAGE

European Technical Approval ETA 13/0526

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

Mold Questions and Answers Questions and Answers on Stachybotrys chartarum and other molds

Energy efficient windows, doors and conservatories. Make a better choice

Testing Rules for Thermal Conductivity October 2015

Crawl space heat and moisture behaviour

How To Make An Oriented Strand Board

Development of conservation compatible new materials for envelope retrofitting of historic buildings

Molds and mildew are fungi that grow

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Improving thermal insulation of concrete sandwich panel buildings

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Rockwool Flexi Insulation Application Guide

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Life Cycle Assessment of zero- emission façade construction

Building materials thermal conductivity measurement and correlation with heat flow meter, laser flash analysis and TCi

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

HFM Heat Flow Meter Thermal Conductivity Analyzer

Software Development for Cooling Load Estimation by CLTD Method

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Distance Staff Cooperation in On-Line Engineering

LIGHTWEIGHT SCREEDS MADE OF CONCRETE AND RECYCLED POLYMERS: ACOUSTIC, THERMAL, MECHANICAL AND CHEMICAL CHARACTERIZATION

Effect of Thermal Barrier on Thermal Protective Performance of Firefighter Garments

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings

Composite Panel Firewall Systems

IUB Water Damage Restoration Guideline

THERMAL INSULATION PROPERTIES OF EXPANDED POLYSTYRENE AS CONSTRUCTION AND INSULATING MATERIALS ABSTRACT

saving energy in comfort Factsheet Recair Enthalpy

Architectural integration of solar thermal collectors into the building envelope

Ageing effect and long term performance of cement bonded particleboard. Prepared for: Viroc Portugal Indústrias de Madeira e Cimento S.A.

Innovation #9/12. of all Formaldehyde for up to

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Performance Test of Solar Assisted Solid Desiccant Dryer

CONDENSATION IN REFRIDGERATED BUILDINGS

Linear thermal transmittance of the assembly of the glazing and the frame in windows

Drying of brick walls after impregnation

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

Ongoing R&D projects in COST member countries

Study of durability of sprayed concrete

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Biological Contamination in the HVAC System

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

Fungal Assessment. Smith Recreation Community Centre 1019 Hwy 2A, Smith, Alberta

Comparison of two calculation methods used to estimate cooling energy demand and indoor summer temperatures

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

HIGH PERFORMANCE THERMAL INSULATION - EXAMPLES FROM THE SWISS BUILT ENVIRONMENT

1 0 0 % E C O - F R I E N D LY

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

WUFI-ORNL/IBP A North American Hygrothermal Model

The University of Birmingham (Live System)

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

Energy and Buildings

All Weather Hall. Efficient, multipurpose & quick to build

Thermal Performance of Steel Beam Junctions using Different Connection Methods

National Building Code of Canada 2010

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

2050 LOW CARBON ECONOMY Executive Summary THE EUROPEAN CEMENT ASSOCIATION

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

Determination of equilibrium moisture content of building materials: some practical difficulties

Models and Methods in Applied Sciences

Soils, Foundations & Moisture Control

Confort 160. Sliding Systems. Sapa Building System

Transcription:

Available online at www.sciencedirect.com ScienceDirect Energy Procedia 00 (2015) 000 000 www.elsevier.com/locate/procedia 6th International Building Physics Conference, IBPC 2015 Thermal, moisture and biological behaviour of natural insulating materials Martin Volf a,b, Jakub Diviš a,b, Filip Havlík a, * a Czech Technical Univeristy in Prague, Faculty of Civil Engineering, Thákurova 7, 160 00 Prague, Czech Republic b Czech Technical Univeristy in Prague, University Center of Energy Efficient Buildings, Třinecká 1024, 273 43 Buštěhrad, Czech Republic Abstract Besides having positive impact on sustainable development, natural building materials also have technical properties comparable with standard materials and important additional qualities. This article focuses on thermal, moisture and biological properties of thermal insulating materials based on vegetal and animal fibres. There is a lack of data regarding natural building materials and furthermore the properties of these types of materials can be sitedependent. Therefore the natural insulating materials have been tested for thermal, moisture and biological properties. In the research array, there were following materials: treated sheep wool, raw sheep wool, wood fibre, hemp, flax, straw bale and compressed straw panel. The main examined parameters are the thermal capacity, thermal conductivity, volume density and sorption isotherm, which are stated and compared. In addition to that, the microbiological identification tests were made together with the mould growth observation. The results of all tests and measurements are stated and discussed in the article with the emphasis on the situation in the real building stock where the test bordering conditions possibly occur 2015 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the CENTRO CONGRESSI INTERNAZIONALE SRL. Keywords: natural insulating materials; sorbtion; conductivity; capacity; measurments 1876-6102 2015 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the CENTRO CONGRESSI INTERNAZIONALE SRL.

2 Author name / Energy Procedia 00 (2015) 000 000 1. Preface 1.1. Context Being the largest contributor to the world s waste production, building industry should focus on sustainability [13]. Natural and recycled materials have remarkably lower environmental impact than the ones standardly produced. These materials are well-performing in the life cycle assessment, even their thermal and moisture properties seem to be favourable. On the other hand, there is a lack of comparable data, regarding available natural building materials Moreover, the properties of these types of materials can be site-dependent (different densities, raw materials and processing). Therefore it is important to analyse and collect new data. A set of measurements has been done during last year to add data to the present state of knowledge. The main argument against the use of natural building materials is their durability and constancy of material qualities. The description of the thermal, moisture and biological characteristics of natural insulations, earth plasters and clay building elements is the main aim of the project held at Czech Technical University in Prague, Department of Building Structures. This paper discusses the test results obtained for the first material array, the insulating materials. 1.2. Material samples selection The selection of the materials was done based on multiple research results, ie. [10], [11], [12] and on the previous research carried out by the authors [1]. The environmental impact (global warming potential, primary energy input and acidification potential) of the concrete frame building can be significantly lowered by using better performing concrete to lower down the mass of concrete needed. Together with that, the building impact can be lowered more by utilizing the sustainable building envelope made of natural or recycled materials. Therefore, the test array was set to describe natural insulating materials, which are the important compound of such composition. The test specimens were following: Compressed straw bale, Flax fibre, Treated sheep wool, Untreated sheep wool, Wood fibre, Hemp fibre, Ordinary mineral wool as reference for selected measurement. All these materials are supposed to be used in the building envelope walls, roof or ceiling composition etc. and they are suitable as the main insulating layer of those compositions. The materials for all the test specimens were taken from similar batch (one plate or bale). The samples came from the standard products obtained at the local market without any additional treatment. 2. Material tests After the environmental-oriented material selection, the description and comparison of the other properties was the next step. The tests were carried out to ensure the sufficient knowledge for the natural material application: thermal conductivity, heat capacity, volume density, sorption parameters and basic mold tests. The material tests were made at the Faculty of Civil Engineering at Czech Technical University in Prague and at the University Centre for the Energy Efficient Buildings in Buštěhrad, Czech Republic.

2.1. Thermal conductivity, thermal diffusivity Author name / Energy Procedia 00 (2015) 000 000 3 For the thermal qualities description, the dynamic measuring method was applied in the beginning. Measuring was performed using portable measuring device ISOMET 2114 with the needle probe IPN 1100. This particular method was selected because of the speed of measuring process and multiple results obtained from one measurement (thermal conductivity, volume heat capacity and thermal diffusivity). The instrument applies a dynamic measurement method analyzing the time dependence of thermal response on pulse transmitted from the heat flow into the material. The heat flow is generated by electrical energy by the probe which is in the direct contact with the measured material. All measurements were done multiple-times to get the relevant data. The measurement accuracy in the range 0,015 0,7 W.m -1.K -1 is 5 % for the particular instrument [2]. For the thermal conductivity particularly, the data was compared with the heat flow meter measurement done according to the [3] where the compliance of the measurement was in the accuracy tolerance. 2.2. Volume density, heat capacity The volume heat capacity values are obtained from the previously described measurement at the same time. Determination of the density was carried out according to the European Standard EN 1602:2013. [4] Table 1. Measured material parameters Thermal conductivity Thermal diffusivity Dry density Volume heat capacity Specific heat capacity Number Sample λ [W.m -1.K -1 ] a [m 2.s -1 ] ρ [kg.m -3 ] c ρ [J.m -3.K -1 ] c m [J.kg -1.K -1 ] 1 Straw bale 0,065 0,43 98,0 0,16 1,58 2 Flax fibre 0,052 0,54 27,0 0,10 3,60 3 Hemp fibre 0,052 0,52 36,2 0,10 2,75 4 Wood fibre 0,048 0,39 51,5 0,12 2,40 5 Treated sheep wool 0,063 1,23 11,3 0,05 4,55 6 Untreated sheep wool 0,062 1,03 29,7 0,06 2,02 7 Mineral wool - reference 0,039 0,43 14,9 0,09 6,04 Fig. 1. Comparing volume heat capacity (a) and thermal conductivity (b).

4 Author name / Energy Procedia 00 (2015) 000 000 The materials were dried out in a drying room at 50 C to the constant weight. The next step was to measure of the linear dimensions of the samples according to the EN 12085 [5]. Length, width and height were measured by the electronic digital caliper with a resolution of 0,01 mm. A Samples volumes were calculated from these dimensions. Results for the material array are stated in the Table 1. 2.3. Sorption Recording of hygroscopic sorption properties was carried out according to the European Standard EN ISO 12571:2013. [6] All natural materials and the reference material were measured in sets of three samples. Each of them had a weight about 50 g. Larger samples take longer time to stabilize at the equilibrium weight, and taking too small samples (less than 10 g) in account may lead to inaccuracy in weighting. Fig. 2. Sorption isotherms (moisture content mass by volume) The materials were dried out in a drying room at 50 C (higher temperatures may change the structure of some natural materials) at the equilibrium weight. The experimental measurement of sorption properties was carried out in the glass desiccator at constant temperature and atmospheric pressure. A data logger for measuring relative humidity and temperature was placed inside each desiccator. Aimed level of relative humidity in the desiccator was created by saturated solutions. These present the particular points in the sorption curve. The first step has been measured using a saturated solution of LiCl (RH 11,3 %). All samples were exposed to that environment until reaching the equilibrium weight. This state was achieved when the weight change during 24 hours was less than 0,1 %. The weight was measured using a digital lab scale with precision of 0,001 g. Next points in the sorption curve were made using saturated solution of KC 2 H 3 O 2 (RH 24,0 %); K 2 CO 3 (RH 43,2 %); NH 4 NO 3 (RH 62,0 %); NaCl (RH 75,5 %); KCl (RH 85,5 %); KNO 3 (RH 95,0 %); K 2 SO 4 (RH 97,6 %). The relative humidity values mentioned in the parenthesis are only proximate. Exact RH values were measured with a datalogger. The Fig.2 shows the measured results of the sorption isotherms.

Author name / Energy Procedia 00 (2015) 000 000 5 3. Biological health risk Talking about the natural materials, it is very important to complete the knowledge of the material with the information about biological qualities. There was no mould growth observed in the samples, while they were in the usual interior environment condition. The simple mould identification was made in the laboratory: all the material samples were put in to the environment suitable for the mold growth (nutrient agar at temperature of 25 C, RH above 80%). These conditions may occur in the wrong designed building details or in the case of faults in the structure composition. This test showed the predominant mould types naturally present in each material. The results are summed up in the Table 4, the potential risks description is done according to [7] and [8]. Table 4. Possible mould growth risks according to [7] and [8] Material Mould Identification Possible risks Sheep wool Alternaria alternata pathogenic, frequent, highly toxic, causing allergy and asthma, cutaneous infections, paranasal sinusitis, osteomyelitis and peritonitis in patients on continuous ambulatory peritoneal dialysis (CAPD) Stachybotrys sp. possibly toxic, causing stachybotryotoxicosis Flax fibre Acremonium sp. seldomly pathogenic: hyalohyphomycosis, arthritis, osteomyelitis, peritonitis, endocarditis, pneumonia, cerebritis and subcutaneous infection. Wood fibre Penicillium (expanzum, biverticillata) pathogenic, toxic (patulin), carcinogenic Hemp fibre Penicillium (biverticillata) pathogenic, toxic Straw bale Alternaria alternata pathogenic, frequent, highly toxic, causing allergy and asthma, cutaneous infections, paranasal sinusitis, osteomyelitis and peritonitis in patients on continuous ambulatory peritoneal dialysis (CAPD) Fusarium sp pathogenic, seldom, causing mycotoxicosis 4. Discussion From the test results it is obvious that thermal conductivity of thermal insulation materials based on natural fibers is 25 % higher than mineral wool. This usually is the only parameter on which is the focus within building design approach. To follow the environmental goals mentioned in the beginning of this paper and by [13], we should consider also other properties. For instance, the volume heat capacity is 11 % (natural fibres) or 78 % (mineral wool) higher with straw bale. Considering that during the design process can favourably affect the thermal comfort of the building. Porous materials can absorb moisture from the air inside their structure. It depends primarily on the size and the inner surface of the pores. The results show that the natural insulation materials sorb more air humidity than the reference material from mineral wool. This ability is due to more complex organic structure of natural materials and it can contribute to creation of healthier indoor environment in the buildings [14]. It is possible to substitute easily insulating materials as mineral wool for natural insulating material (i.e. two-byfour design for wooden building). Insulating layers made of flax, hemp and especially wood fibres have competitive thermal conductivity values (Fig.1b) and are produced in mats of standard size. This brings the need to design constructions slightly thicker to achieve equal thermal resistance (U-value). Straw has the highest thermal capacity (Fig.1a) and best sorption properties among all tested materials. On the other hand it has higher thermal conductivity which would lead to greater wall thickness for equal thermal resistance as eg. with mineral wool. But when the way of processing straw into straw bales is considered, the construction would anyway have greater thickness. The important difference brought by using natural insulating material is significantly better sustainability. Compared to mineral wool, primary energy input, global warming potential or acidification potential levels of natural insulations are about 95 % lower [9].

6 Author name / Energy Procedia 00 (2015) 000 000 The health risk is low in properly designed buildings. The toxic nature of fungi spores could be present in natural insulations shows that proper and safe construction design is extremely important for natural materials. In buildings built with the amateur approach or buildings where the risk of failure in structures is high (i.e. RH value grows up above 80 % together with the temperature above 15 C), natural insulating materials can cause illnesses as proven by our biological health risk analysis. 5. Conclusion Natural insulations can be favourably used in standard buildings in combination with common building materials to achieve more sustainable solution and healthy indoor environment. It was found that natural insulations have comparable thermal properties to common building insulation materials and can bring advantages in thermal and moisture buffering. The biological pollution has been tested under laboratory conditions (use of agar, increased stable temperature and moisture). It is a question whether the conditions that would promote biological degradation will occur in real constructions. Therefore a long term testing in real Czech weather conditions is held to study the real risk of fungus growth. Acknowledgements The presented work has been supported by the European Union, OP RDI project No. CZ.1.05/2.1.00/03.0091 University Centre for Energy Efficient Buildings; OP RDI project No. CZ.1.05/3.1.00/13.0283 Intelligent Buildings. This outcome has been also financially supported by internal grants of CTU SGS14/113/OHK1/2T/11 Analysis and optimization of properties of natural building materials effecting quality of interior microclimate of buildings. References [1] C. Fiala, P. Hájek, T. Pavlů, M. Volf. Solution of prefabricated systems made of high performance concrete in combination with curtain wallsbased on wood, recycled materials and biomaterials, project final report, 2010 [2] Applied Precision Ltd., ISOMET: Portable heat transfer analyzer, [Online]. Available: http://www.appliedp.com/download/catalog/isomet_pc_en.pdf. 2015 [3] EN 12667:2001 Thermal performance of building materials and products Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance [4] EN 1602:2013. Thermal insulating products for building applications. Determination of the apparent density. 2013 [5] EN 12085:2013. Thermal insulating products for building applications. Determination of linear dimensions of test specimens. 2013 [6] EN ISO 12571:2013. Hygrothermal performance of building materials and products. Determination of hygroscopic sorption properties. 2013 [7] M. Němec, Miniatlas mikroorganismů, VŠCHT v Praze, 2008.(in Czech) [Online]. Available: http://old.vscht.cz/obsah/fakulty/fpbt/ostatni/miniatlas/. [8] D. Ellis, Mycology Online, The University of Adelaide, 2015. [Online]. Available: http://www.mycology.adelaide.edu.au/. [9] Swiss Centre for Life Cycle Inventories, The ecoinvent Database, 2015. [Online]. Available: http://www.ecoinvent.org/database/. [10] M. Asif, T. Muneer, R. Kelley, Life cycle assessment: A case study of a dwelling home in Scotland, Building and Environment, Volume 42, Issue 3, March 2007, Pages 1391-1394, ISSN 0360-1323 [11] Kenneth Ip, Andrew Miller, Life cycle greenhouse gas emissions of hemp lime wall constructions in the UK, Resources, Conservation and Recycling, Volume 69, December 2012, Pages 1-9, ISSN 0921-3449 [12] Asdrubali F.The role of life cycle assessment (LCA) in the design of sustainable buildings: thermal and sound insulating materials. In: Proceedings of Euronoise 2009, Edinburgh,Scotland;26 28 October2009. [13] Cuchí, A., et al. Global Vision Report [online], Barcelona: WSB14 Barcelona Conference, 2014. Available: http://www.wsb14barcelona.org/downloads/global-vision-report.pdf [14] RICHTER, J., et al. Stabilization of indoor humidity by rammed earth. Advanced Material Research, Vol. 1000, pp. 342-345. ISSN 1022-6680