Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors



Similar documents
How To Install A Carbon Monoxide Detector

System-Connected Carbon Monoxide Detectors

GC2 Panel User Guide

ICC CODE CORNER 2012 IFC Code & Commentary

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Smoke Detector/Carbon Monoxide Detector Inspections

Alarms. State of Wisconsin Rules ss (2) and (3) Comm Comm

Fire Standards & Regulations Are you confused?

User s Guide. Security Systems D220

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

The Buhl Electric Secure Home. Brought to you by Buhl Electric. Security Packages and Options

Wireless Security System

Using your LED Plus keypad

Low Frequency Notification Appliances

Smoke & Carbon Monoxide

Effective June 27, TEXT (CO Detection Commercial Buildings)

MINERVA MX MX Virtual Multi-Sensor Detectors

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section , to read as follows:

P/N Rev D

SECTION DETECTION AND ALARM

System off. Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork

Fire & Security DETECTORS

Y7230A CO 2 Alarm System

INSTALLATION AND OPERATION MANUAL

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Wireless Security System

Fire detection equipment

Know Your Smoke Alarm

SECURITY SYSTEM NOTES

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

ERS-2400B. PERS-2400B Personal Emergency Reporting System

USER S MANUAL. SMDC-16 Digital Control Communicator and SMPC-32 Personal Control

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

System off. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

D287/D288/D292/D293A/D293E

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

The Alberta Fire Code requires all homes in the province to have working smoke alarms.

HERNANDO COUNTY FIRE ALARM GUIDELINES

SECURITY SYSTEM NOTES

616, 626, 636 & 646 Keypads

Requirements for Smoke/Carbon Monoxide & Fire Extinguisher Certification

Smoke Alarms Save Lives!

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Rogers Smart Home Monitoring QUICK START GUIDE ROG_6093_QST_GDE_EN.indd 1 9/22/12 8:29 AM

Fire Alarm system Installation Guide

TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

University Design Standard. Fire Alarm Systems

GEORGIA DEPARTMENT OF COMMUNITY AFFAIRS (DCA) STATE CODES ADVISORY COMMITTEE (SCAC) CARBON MONOXIDE DETECTORS FOR SCHOOLS TASK FORCE

CERTIFICATE OF COMPLIANCE

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Smoke & Carbon Monoxide

908.7 (New) [IBC [F] (New)], (New), Chapter 47 (IBC Chapter 35)

ESL 429/449 Series Self-Diagnostic Photoelectric Smoke Detectors Installation Instructions

Palos Verdes Estates Police Department 340 Palos Verdes Drive West, Palos Verdes Estates, CA (310)

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

USER INSTRUCTIONS CONTENTS

Welcome to Bell Aliant NextGen Home Security

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Smoke Detectors Ordering Information DS230 DS230 Series Heat Detectors DS230F DS233F Peripheral Accessories EOL200 TP280 Bases Features

Module 5. Fire and Emergency Alarm System Part I- Basics

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

Fire Sprinkler Monitoring PRODUCTS. Accessories Alarm Bells Waterflow Detectors Pressure Switches Supervisory Switches Explosion-Proof

BS5839 Part 1:2002 Overview

TX Carbon Monoxide Alarm Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Call reduction guidance for false alarm/ unwanted fire signals

Macurco CM-E1 Carbon Monoxide Detector

Total Protection Alarm System

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

NetworX NX-6V2. LED Keypad User Manual

System off. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

Solution Ultima ICP-CC488 Home security you can rely on

Smoke Alarm Legislation

User Guide for the DS7060 Control/Communicator

tattletale User Guide Consumer unit version P a g e

Stove Guard Kit User Manual


! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

Guide to Massachusetts Smoke & Carbon Monoxide Requirements

Contact ID Event Definition Codes

Residential & Commercial Alarm Systems by Gross Security, LLC

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Instructions for Obtaining a Certificate of Smoke Detector, Carbon Monoxide Alarm, and Kitchen Fire Extinguisher Compliance

SECURITY & MONITORING QUICK GUIDE

Transcription:

Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors

2

Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable electrochemical sensing technology to measure CO levels in the air. If a dangerous amount of CO is detected, the CO1224T/CO1224TR will alert residents by sounding a Temporal 4 alarm tone and flashing its red LED. Protection is guaranteed 24/7 by an alarm transmission to a central station, regardless of whether residents are away from home, sleeping, or already suffering from the effects of CO. Benefits of Monitored Detection CO detectors monitored by a central station provide peace of mind by including an extra level of protection when: The residence is empty CO1224T Carbon Monoxide Detector Residents are sleeping Pets, children, and elderly are alone Residents are already suffering from symptoms of CO exposure (drowsiness, unconsciousness, etc.) A maintenance problem arises with the detector If CO concentration reaches dangerous levels and triggers an alarm, the central station has the ability to contact the occupant and/or first responders. The central station will also alert the end user if the detector: Has been tampered with 15 % Of homes have CO detectors installed. Is experiencing mechanical trouble Is in sensor end-of-life due to the limited life span of CO detection technologies systemsensor.com/co 3

Features and Benefits RealTest The CO1224T and CO1224TR detectors from System Sensor offer RealTest: a true functional CO test that s the first of its kind. With RealTest, a simple short spray of canned CO is all it takes. Now you can leave your job knowing the detector is doing its job. UL Listed The CO1224T/CO1224TR is fully compliant with UL 2075. Electrochemical Sensing Electrochemical detectors are the newest, most reliable CO detectors available. They take the most accurate readings of CO, from low levels of CO that may be hazardous over long periods of time to high concentrations that present an immediate danger. They are also less prone to false alarms than other types of CO sensing technologies. End-of-Life Notification 62,000 People Poisoned by CO Annually The CO1224T and CO1224TR are equipped with a six-year endof-life notification system that alerts the central station at the end of each detector s functional life span. This enables service providers to proactively make service calls without the homeowner worrying about checking the detector. SEMS Terminals The CO1224T/CO1224TR features SEMS terminals that provide electrical supervision and fast, easy wiring. Versatile Mounting Options The CO1224T/CO1224TR can be mounted to a single-gang electrical box or surface mounted to the wall or ceiling with ample room for wire entry. Low Current Draw The CO1224T/CO1224TR has a current draw of 20 ma in standby and 40 ma in alarm. This means that more CO detectors can be connected to the panel without purchasing a more expensive panel or an extra auxiliary power supply. 24-Hour Protection Protect your customers with 24/7 central station monitoring; you can protect your customers from a poison they cannot see, smell, or taste. 4

Save Lives RealTest You can save lives! According to the Journal of the American Medical Association (JAMA), carbon monoxide is the number one cause of unintentional poisoning deaths in the United States. The System Sensor CO1224T and CO1224TR CO Detectors provide RealTest the first functional CO test fully compliant with NFPA 720: 2009. With a simple short spray, anyone can test the CO sensing cell to verify it is working. Installation Guidelines The CO1224T/CO1224TR can be mounted to a single-gang box or surface mounted to the wall or ceiling. In a wall location, the detector should be at least as high as a light switch and at least six inches from the ceiling. In a ceiling location, the detector should be at least 12 inches from any wall. 1. Where to Install CO Detectors Within 10 feet of each sleeping area Inside each sleeping area if occupied by the hearing impaired Near kitchens with a gas burning stove Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. On each floor of the house Away from vents and the reach of children and pets In the vicinity of flame-fueled appliances, but no closer than 10 feet 2. Spray canned CO agent into the detector. CO Detector Placement Bedrooms 3. Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. Kitchen Basement Carbon Monoxide Detector location for multi-level residence systemsensor.com/co 5

CO1224T & CO1224TR Carbon Monoxide Detectors The CO1224T and CO1224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code-required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the CO1224T and CO1224TR will operate on most security and fire alarm control panels. Carbon Monoxide Detectors CO1224T CO122TR 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest Technology, Square 12/24 volt, 4-wire system-monitored round carbon monoxide detector with RealTest Technology, Round Features RealTest enables a functional test using canned CO Full compliance with UL 2075 A code-required trouble relay Wiring supervision with SEMS terminals Simplify Replacements with CO-PLATE To upgrade competitive detectors to the CO1224T, installers can easily connect the CO1224T to existing wiring. In cases where the footprint of the old detector must be covered, the CO-PLATE perfectly covers the outline of the old and bulky competitive detector. The CO1224T then mounts to the CO-PLATE for a clean, low-profile finish ideal for commercial and residential applications. A six-year end-of-life timer 12/24 VDC A low current draw of 20 ma in standby and 40 ma in alarm Versatile mounting for wall or ceiling Accurate and reliable electrochemical sensing technology Optional CO Detector Replacement Plate, CO-PLATE, to upgrade previously installed competitor detectors to the CO1224T CO-PLATE CO detector replacement plate 6

i 4 Series Combination CO/Smoke Detectors 4 The i 4 Series Combination CO/Smoke Detector includes a variety of features that simplify installation and maintenance while increasing the level of protection for your customers. Single detector for CO and smoke detection that uses less wiring and fewer junction boxes Requires the use of the i4 Interface and Synchronization Module Interface module connects up to 12 detectors to panel and is compatible with a wide range of control panels Sends distinct smoke and CO signals to the panel Sounds Temp 3 for smoke and Temp 4 for CO Built-in 85dB sounder LEDs display operational, CO, and smoke status External IR LED provides extended range smoke sensitivity testing Versatile mounting allows for wall or ceiling placement Easily replaceable electrochemical CO cell with 6-year end-of-life timer that signals the panel and chirps to alert the homeowner RealTest enables functional gas testing using canned CO Drift compensation and smoothing algorithms provide false alarm immunity Compatible with SENS-RDR smoke sensitivity tester For product specifications, visit www.systemsensor.com/i4 i 4 Series CO/Smoke Detectors COSMO-2W COSMO-4W 12/24 volt, 2-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology 12/24 volt, 4-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology i 4 Series Interface Modules The required i 4 Interface Module enables the system to send distinct CO and smoke signals over only two or four wires, greatly reducing installation time and cost. i 4 Series Interface Modules COSMOD2W 2-wire interface and reversing relay module COSMOD4W 4-wire interface and reversing relay module systemsensor.com/co 7

Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology. System Sensor develops products for real-world applications worldwide. With sales, service, and manufacturing facilities throughout the Americas, Europe, and Asia, System Sensor places a premium on research and development to provide the most reliable, innovative, and comprehensive line of products in the industry. www.systemsensor.com/co 2014 System Sensor. Product specifications subject to change without notice. COBR43501 12/14