Title: Low EMI Spread Spectrum Clock Oscillators



Similar documents
Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

Reducing EMI and Improving Signal Integrity Using Spread Spectrum Clocking

Electromagnetic. Reducing EMI and Improving Signal Integrity Using Spread Spectrum Clocking EMI CONTROL. The authors describe the

ICS379. Quad PLL with VCXO Quick Turn Clock. Description. Features. Block Diagram

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

SPREAD SPECTRUM CLOCK GENERATOR. Features

AND9015. A Solution for Peak EMI Reduction with Spread Spectrum Clock Generators APPLICATION NOTE. Prepared by: Apps Team, BIDC ON Semiconductor

ICS SPREAD SPECTRUM CLOCK SYNTHESIZER. Description. Features. Block Diagram DATASHEET

TRIPLE PLL FIELD PROG. SPREAD SPECTRUM CLOCK SYNTHESIZER. Features

Spread Spectrum Clock Generator

Spread Spectrum Clock Generator

LOW POWER SPREAD SPECTRUM OSCILLATOR

High Precision TCXO / VCTCXO Oscillators

RX-AM4SF Receiver. Pin-out. Connections

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D.

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

4 OUTPUT PCIE GEN1/2 SYNTHESIZER IDT5V41186

VCO Phase noise. Characterizing Phase Noise

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

MATRIX TECHNICAL NOTES

V CC TOP VIEW. f SSO = 20MHz to 134MHz (DITHERED)

Chapter 6 PLL and Clock Generator

Design and Certification of ASH Radio Systems for Japan

AN-837 APPLICATION NOTE

PCI-SIG ENGINEERING CHANGE NOTICE

Signal Types and Terminations

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

ICS514 LOCO PLL CLOCK GENERATOR. Description. Features. Block Diagram DATASHEET

Spread-Spectrum Crystal Multiplier DS1080L. Features

This application note is written for a reader that is familiar with Ethernet hardware design.

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

How Spread Spectrum Clock Generators Accelerate FCC Certification of System Designs

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Pericom PCI Express 1.0 & PCI Express 2.0 Advanced Clock Solutions

Clocking. Figure by MIT OCW Spring /18/05 L06 Clocks 1

Configurable High Performance SMD TCXO/VCTCXO

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

PECL and LVDS Low Phase Noise VCXO (for MHz Fund Xtal) XIN XOUT N/C N/C CTRL VCON (0,0) OESEL (Pad #25) 1 (default)

Spread Spectrum Clock Generator AK8126A

Vi, fi input. Vphi output VCO. Vosc, fosc. voltage-controlled oscillator

Timing Errors and Jitter

Selecting the Optimum PCI Express Clock Source

ILB, ILBB Ferrite Beads

VME IF PHASE MODULATOR UNIT. mod

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/ FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

Phase-Locked Loop Based Clock Generators

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

Current Probes. User Manual

Understanding Power Impedance Supply for Optimum Decoupling

Rail-to-Rail, High Output Current Amplifier AD8397

2 TO 4 DIFFERENTIAL PCIE GEN1 CLOCK MUX ICS Features

Clocking Solutions. Wired Communications / Networking Wireless Communications Industrial Automotive Consumer Computing. ti.

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

ICS Pentium/Pro TM System Clock Chip. Integrated Circuit Systems, Inc. General Description. Pin Configuration.

11. High-Speed Differential Interfaces in Cyclone II Devices

Experiment # (4) AM Demodulator

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

MITSUBISHI RF MOSFET MODULE RA07H4047M

Cable Analysis and Fault Detection using the Bode 100

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

PL-277x Series SuperSpeed USB 3.0 SATA Bridge Controllers PCB Layout Guide

DS2187 Receive Line Interface

Input and Output Capacitor Selection

Introduction to Receivers

Digital to Analog Converter. Raghu Tumati

Application Note 58 Crystal Considerations with Dallas Real Time Clocks

Product Datasheet P MHz RF Powerharvester Receiver

CLOCK AND SYNCHRONIZATION IN SYSTEM 6000

Time and Frequency Domain Analysis for Right Angle Corners on Printed Circuit Board Traces

Absolute maximum. User Manual

LOW POWER FM TRANSMITTER SYSTEM

DATA SHEET. SiGe LOW NOISE AMPLIFIER FOR GPS/MOBILE COMMUNICATIONS. Part Number Order Number Package Marking Supplying Form

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

Fairchild Solutions for 133MHz Buffered Memory Modules

Application Note 58 Crystal Considerations for Dallas Real-Time Clocks

ZLPLL Local Oscillator

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

MoCA 1.1 Specification for Device RF Characteristics

EMC-conform development of a Tablet-PC

AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC

Single Transistor FM Transmitter Design

Photolink- Fiber Optic Receiver PLR135/T1

Module 11: Conducted Emissions

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

VS-500 Voltage Controlled SAW Oscillator

Baseband delay line QUICK REFERENCE DATA

EVALUATION KIT AVAILABLE Single-Chip Global Positioning System Receiver Front-End BIAS CBIAS GND GND RFIN GND GND IFSEL

Real Time Clock Module with I2C Bus

Push-Pull FET Driver with Integrated Oscillator and Clock Output

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

Simplifying System Design Using the CS4350 PLL DAC

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

MAINTENANCE & ADJUSTMENT

3 V/5 V Low Power, Synchronous Voltage-to-Frequency Converter AD7740*

Transcription:

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 1 of 1 Background Title: Low EMI Spread Spectrum Clock Oscillators Traditional ways of dealing with EMI (Electronic Magnetic Interference) problems include using EMI filters, ferrite beads, chokes, adding power layer and ground plane to the board, more metal shielding and special coating and RF gaskets. However, the principle sources of EMI problem come from the system clocks including frequency timing generators, crystal oscillators, VCOs and PLLs. It is obvious that the most efficient and economic way to reduce EMI for the whole system is to use low EMI spread spectrum clock (SSC) oscillators. The advantages of using low EMI oscillators are easy passage of regulatory testing, short time-to-market and cost reduction. Spread Spectrum Technology (SST) Maximum allowable EMI radiation is normally referred to the peak EMI emissions not the averaged emissions. A good approach is to spread out the concentrated mode energy on one particular frequency to a broader bandwidth and controlled frequency range (for example: center frequency ±1%) with a controlled modulation rate. The total mode energy remains the same but the peak energy got spread out to near-by frequencies. This frequency modulation technique is known as Spread Spectrum Technology (SST). In stead of patching the EMI problems with filtering and shielding, SST provides efficient and low cost solutions to the expensive EMI problems. Spread Spectrum Clock Oscillator (SSC) takes advantage of the SST to provide low EMI frequency sources. In most of the cases, system designers face the EMI problem at the time their products fail the EMI/EMC regulations at the test labs. Mercury HM series low EMI crystal oscillators provide drop-in replacement solution for situation like these. The big plus is no board re-spinning. As shown in the following spectrum comparison graphs, a conventional clock (un-modulated) has narrow band width and peak radiation energy. By the SST, a 1 db or more of the EMI reduction can be expected. The modulation carrier frequency is usually in the range of 6 to 55 KHz (Mercury model and frequency dependent) which makes the modulation process transparent to the oscillator frequency. Consequently, electronic devices have lower EMI emissions but not affected by the resultant instantaneous frequencies. Center Spread vs. Down Spread The controlled modulation process can be on all of one side of the nominal frequency (down spread) or 5% up and 5% down (center spread). Pick 1 MHz SSC as an example, its center frequency is modulated between 99.5 MHz and 1.5 MHz with center spread of.5%; the frequency range is between 99.5 MHz and 1. MHz if down spread at.5%. By moving the center frequency, a down spread.5% modulation can be considered a process equivalent to a center spread of.25%. In another word, modulation between 99.5 MHz and 1. MHz (down.5%) is equivalent to center spread.25% with center frequency at 99.75 MHz. Instantaneous Frequencies (min.) Center Frequency Instantaneous Frequencies (max.) A. 1 MHz at center spread.5% 99.5 1. 1.5 B. 1 MHz at down spread.5% 99.5 1. B is equivalent to 99.75 MHz at center spread of.25% 99.5 99.75 1. The down spread is preferred if a system can not tolerate operating frequency higher than the nominal frequency (over-clocking problem). In the above 1 MHz center spread.5% example, there is a period of time that the system running between 1. MHz and 1.5 MHz, these instantaneous frequencies are higher than the system clock and may erode system timing margin. Using down spread can avoid this problem with the sacrifice of a slightly slower clock rate. Down-center spread (also called asymmetric spread), a compromised way of the two, is another choice and available in some Mercury HM series

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 2 of 2 Conventional Clock Conventional Clock db db EMI reduction Spread spectrum clock EMI reduction fc fo - (fo*1%) fc fo - (fo*.5%) fo=fc fo + (fo*.5%) F F fo + (fo*.5%) fo T fo T fo - (fo*.5%) Modulation Carrier frequency fo - (fo*1%) Modulation Carrier frequency Figure 1: Spectrum comparisons. 1% down spread and ±.5% center spread as examples Modulation Carrier Frequency: The modulation carrier frequency (sweep rate) is typically around KHz range which is relatively slower compared with the MHz range of the clock frequency. As shown in figure 1, the output frequency is slowly swept within the pseudo triangle shape wave envelope from the f(max). to fo(nominal) then to f(min) then to fo(nominal)., back and forth. The resultant instantaneous frequencies are always between f(max) and f(min). The modulation percentage determines the bandwidth of the span while the modulation carrier frequency determines the spacing of the spectral. EMI Reduction at Harmonics: As seen in figure 2 and figure 3, higher order harmonic frequencies do get stronger EMI reduction. They also show that the greater modulation percentage reduces EMI emissions more. It needs to be pointed out that the fundamental frequency as well as every harmonics all gets EMI reduction by the SST.

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 3 of 3 Group: P SST Fout = 125 MHz EMI Reduction (db) 28 25 22 19 16 13 1 7 1 3 5 7 9 11 13 15 17 19 HARMONICS.5% 1% 1.5% 2% 3% 3.5% Figure 2: EMI reduction at harmonics for Mercury HM series group P Group: W SST Fout = 16.384 MHz EMI Reduction (db) 18 16 14 12 1 8 6 4 2 1 3 5 7 9 11 13 15 17 19 HARMONICS 1.25% 3.75% Figure 3: EMI reduction at harmonics for Mercury HM series group W

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 4 of 4 Measurement Data: EMI reduction data shown below are actual measurement data taken from Mercury 3HM57 series group R. SSC 1 MHz at various spread percentages and harmonics at each percentage are shown. TS35B Spectrum analyzer Waveform @SSC=OFF TS35B Spectrum analyzer Waveform @SSC=+/-.25% -1-2 -3-4 -5-6 -7-8 -9-1 -3.33dBm 96 97 98 99 1 11 12 13 14-1 -2-3 -4-5 -6-7 -8-9 -1-11.19dBm 96 97 98 99 1 11 12 13 14 TS35B Spectrum analyzer Waveform @SSC=+/-.5% TS35B Spectrum analyzer Waveform @SSC=+/-1.5% -1-2 -3-4 -5-6 -7-8 -9-1 -12.98dBm 96 97 98 99 1 11 12 13 14-1 -2-3 -4-5 -6-7 -8-9 -1-18.54dBm 96 97 98 99 1 11 12 13 14 TS35B Spectrum Analyzer Waveform @SSC=OFF -1-3.21-1.4-2 -2.15-24.25-25.4-3 -35.4-4 -5-6 -7-8 -9-1 1 2 3 4 5 6 7 8 9 1 11 12 TS35B Spectrum Analyzer Waveform @SSC=+/-.25% -1-11.21-2 -2.19-3 -33.37-37.72-38.87-4 -48.97-5 -6-7 -8-9 -1 1 2 3 4 5 6 7 8 9 1 11 12 TS35B Spectrum Analyzer Waveform @SSC=+/-.5% TS35B Spectrum Analyzer Waveform @SSC=+/-1.5% -1-2 -3-4 -5-6 -7-8 -9-1 -12.8-24.45-36.75-41.23-42.47-51.4 1 2 3 4 5 6 7 8 9 1 11 12-1 -2-3 -4-5 -6-7 -8-9 -1-19.46-29.9-41.22-46.35-48.47-58.77 1 2 3 4 5 6 7 8 9 1 11 12

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 5 of 5-24 Gain (db) -22-2 -18-16 -14-12 -1 5 MHz 32.768 MHz 25 MHz 25 MHz 32.768 MHz 5 MHz SSC is off -1.1 db -9.9 db -1.1 db SSC=±.25% -15.5 db -15.6 db -16.3 db SSC=±.5% -17.6 db -17.8 db -18.2 db SSC=±1.5% -22.9 db -23. db -23.3 db 25 MHz, 32.768 MHz and 5. MHz at center spread ±.25%, ±.5% and ±1.5%. -8 off.25.5.75 1. 1.25 1.5. SSC % TS32B(Down Spread) Spectrum Analyzer Waveform @SSC=OFF TS34B(Center Spread) Spectrum Analyzer Waveform @SSC=OFF -1-3.78dBm -2-3 -4-5 -6-7 -8-9 -1-1 -3.76dBm -2-3 -4-5 -6-7 -8-9 -1 TS32B(Down Spread) Spectrum Analyzer Waveform @SSC=-3.% TS34B(Center Spread) Spectrum Analyzer Waveform @SSC=+/-1.5% -1-2 -3-4 -5-6 -7-8 -9-1 -17.11dBm TS32B SSC : OFF - (-3.%) Reduction = 13.33dBm -1-2 -3-4 -5-6 -7-8 -9-1 -16.82dBm TS324 SSC : OFF - (+/-1.5%) Reduction = 13.6dBm 25 MHz at down spread -3% and center spread ±1.5%. The EMI reduction is about the same.

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 6 of 6 Start-up Time (u. sec.) Current Consumption (ma) Tr Rise Time (n. sec.) Tf Fall Time (n. sec.) Duty Cycle (%) Logic 1 2 3.1 1.9 2. 48.4 3.4.14 SSC=OFF 29 3. 2.1 2.3 48.5 3.31.25 2 3. 1.9 2.5 48.6 3.39.16 Center 78 8.4 2.2 2.5 49.1 3.31.14 Spread 78 8.1 2.8 2.3 5. 3.23.18 ±.25% 88 8.3 2.3 2.1 48.9 3.3.15 Center 88 8.4 2.4 1.5 49.4 3.16.25 Spread 78 8.5 2.6 2.3 49.5 3.32.6 ±.5% 88 8.5 2.7 2.1 49.2 3.36.11 Center Spread ±1.5% 78 8.9 1.4 1. 48.6 3.19.14 88 8.7 1.7 1. 49.1 3.16.14 98 8.5 2.1.5 49.1 3.4.14 +3.3V, 25. MHz, group R oscillator parameter comparisons, Ta=25 C, CL=15 pf SSC Block Diagram: Spread spectrum technology can be simplified and expressed as follow. Logic Modulation carrier frequency in KHz range Frequency Input Ref. Phase Detector ø Low Pass Filter VCO SSC output

Title: Low EMI oscillators Date: March 3, 24 TN No.: TN-2 Page 7 of 7 Jitter Due to Frequency Modulation: Although the SST modulation is processed in the background and the modulation carrier is at least one thousand times slower compared with the nominal frequency, one still concerns the jitter contributed to the whole system due to the instantaneous frequency. A comparison between clocks with and without SST modulation shows that the modulation process contributes less than.5% of the cycle-to-cycle jitter to the system. This negligible jitter contribution makes the spread spectrum oscillators gain more popularity. Mercury 3HM57 series has 25 ps typical and 3 ps max. for the group R and ±1 ps max. for the group P. Concerns of using SSC on PLL Most of the PLLs can work with SST clocks without any timing problem. However, downstream PLLs (defined as PLLs that receive clock signal from other PLLs in the circuit) requires extra precaution in terms of tracking skew. There are PLLs (Zero delay buffers ) available in the market specifically designed to work with spread spectrum clocks. Another area to be concerned is the tracking rate of a PLL needs to be faster than the modulation rate of the SST. All Mercury HM series has modulation carrier frequency below 6 KHz, downstream PLLs with 6 u sec tracking capability will work fine. Power Supply to the SSC Power supply filtering plays important role to the EMI reduction and optimum jitter performance. Circuit below shows the recommended power supply filtering configuration. This lowpass Ð (PI) filter can remove power supply noise and prevent clock noise from feeding back to the supply. C 1 is low frequency supply decoupling capacitor, a tantalum type and 22 uf is recommended. C 2 is high frequency supply decoupling capacitor, a.1 uf ceramic chip capacitor is recommended. C 3, a decoupling capacitor for the SSC, can be a.1 uf ceramic chip capacitor. If ferrite bead, C 1 and C 2 are not available, tantalum type capacitor is preferred for the C 3. All capacitors should be placed as close to the SSC as possible, otherwise the increased trace inductance will negate its decoupling capability. System Power Supply Ferrite Bead C 1 22uF Tantalum Cap. +.1uF Ceramic Chip Cap. V DD to SSC C 2 C 3.1uF Ceramic Chip Cap. 5.±.15 Rs SSC Output Series Termination Resistor (Rs) SSC output traces over one inch should use series termination. The output impedance of group P and group R SSCs is 3 ohms. Therefore, for typical 5 ohm trace impedance boards, a 22 ohm chip resistor is recommended. 47 ohm is recommended for 75 ohm trace impedance boards. The series resistor should be placed in series with the clock line and as close to the SSC output pin as possible. The series resistor helps to maintain the signal integrity and enhance the EMI emissions reduction.