Trends in Power Quality



Similar documents
SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES

Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

Make your electric distribution network safe

Electricity Service Standards

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

VOLTAGE CONTROL IN DISTRIBUTION SYSTEMS AS A LIMITATION OF THE HOSTING CAPACITY FOR DISTRIBUTED ENERGY RESOURCES

Integration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering

Development of an Electrical Power Quality Monitor Based on a PC

Laboratory and field measurements of the power factor and the harmonic emission from energy-efficient lamps

High Frequency Power Quality

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

SUMMARY - RELATIONSHIP BETWEEN QUALITY OF SERVICE DEMANDED AND TARIFF

EGSTON Standard E2xFxWx 12W

Ingegneria Elettrotecnica. Development of Human Visual System Analysis Methods for the Implementation of a New Instrument for Flicker Measurements

Size template. Grid Connection Masterclass Energex John Lansley Senior Network Solutions Engineer

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

PLAN YOUR PERFECT WINTER!

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

Power Meter Series 700

CERN Accelerator School. Electrical Network and Power Converters. Hans Ulrich Boksberger Paul Scherrer Institute 5232 Villigen PSI Switzerland

Project Management Professionals Hot Topics & Challenges Quality Management. Topic: Seven Basic Quality Management Tools

INTRODUCTION TO HARMONIC ASSESSMENT IN POWER SYSTEMS

Audit Report Rottnest Island 2015 Network Quality and Reliability of Supply Performance Audit - Operation of Compliance Monitoring Systems

Developing a Utility/Customer Partnership To Improve Power Quality and Performance

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

How To Limit Voltage Unbalance

Power products and systems. Intelligent solutions for power distribution Zone concept

LAUREA MAGISTRALE - CURRICULUM IN INTERNATIONAL MANAGEMENT, LEGISLATION AND SOCIETY. 1st TERM (14 SEPT - 27 NOV)

REINVESTMENT STRATEGY MAKING FOR DISTRIBUTION NETWORKS

4 th Benchmarking Report on Quality of Electricity Supply 2008

SIMULATING HYBRID ENERGY GRIDS IN SMART CITIES FOCUS ON ELECTRIC ENERGY SYSTEMS

15 Series - Electronic step relay and dimmer. Features SERIE

Chapter 4. Probability Distributions

Power Quality Standards for Electric Service

SZI IR Audio Transmission Technology Modulators/Radiators

An International Railway Network at your service

Power Quality & Custom Power

Data driven approach in analyzing energy consumption data in buildings. Office of Environmental Sustainability Ian Tan

Electromagnetic Compatibility (EMC) Low-Frequency Standards. Standards on Low-Frequency Emission: IEC

NET METERING SUB-CODE. for Connecting Renewable Energy Generating Systems to the Distribution Network in Ghana

Systematic Optimisation of Gearboxes for Hybrid and Electric Vehicles in Terms of Efficiency, NVH and Durability

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Modeling of PV Based Distributed Generator Systems with Diverse Load Patterns

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Network Analyzer for Low-, Medium- and High-Voltage Networks

2. Filling Data Gaps, Data validation & Descriptive Statistics

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

Enhancing the SNR of the Fiber Optic Rotation Sensor using the LMS Algorithm

Network Consulting for Power Grid Optimization

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

A Network Reference Model for Distribution Regulation and Planning: the Spanish Case

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Probabilistic Forecasting of Medium-Term Electricity Demand: A Comparison of Time Series Models

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

7-41 POWER FACTOR CORRECTION

Test & Data Management Software

A Regime-Switching Model for Electricity Spot Prices. Gero Schindlmayr EnBW Trading GmbH

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Supply Standards: Electricity Supply Standard July JULY 2011 ISSUE 6 UNCLASSIFIED UNCONTROLLED COPY IF PRINTED

Point Biserial Correlation Tests

De Jaeger, Emmanuel ; Du Bois, Arnaud ; Martin, Benoît. Document type : Communication à un colloque (Conference Paper)

Kit Watt Audio Amplifier

English version. Voltage characteristics of electricity supplied by public distribution systems

INFLUENCE ANALYSIS OF SMALL REPOWERED WIND POWER PLANTS ON THE RELIABILITY OF THE LOCAL GRID

STRATO LED Drivers 70W, Single output

CONTENTS PREFACE 1 INTRODUCTION 1 2 DATA VISUALIZATION 19

2013 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list

TELEPHONE SYSTEM F.A.Q.

MAINTENANCE STRATEGIES FOR DISTRIBUTION NETWORKS

SOLAR300N Rel /01/10

Power Electronics Testings

Flicker happens. But does it have to?

The ITER Earthing Topology: Mesh-Common Bonding Network

Federal Ministry for Transport, Innovation and Technology (Austria)

Exploratory Data Analysis

Protect. Surge Protection for home and small office

InputFile.xls - Introduction - page -1 -

There e really is No Place Like Rome to experience great Opera! Tel: to discuss your break to the Eternal City!

TDMS Test & Data Management Software

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

Kinetic energy recovery on railway systems with feedback to the grid

TL084 TL084A - TL084B

SOFTWARE FOR THE OPTIMAL ALLOCATION OF EV CHARGERS INTO THE POWER DISTRIBUTION GRID

AMI Implementation in Energa Operator

DATA SHEET. TDA1543 Dual 16-bit DAC (economy version) (I 2 S input format) INTEGRATED CIRCUITS

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

ENA Customer Guide to Electricity Supply

Electricity Network Performance Report 2012/13

Transcription:

Trends in Power Quality Herwig Renner Graz University of Technology Institute for Electrical Power Systems

Contents Results from long term harmonic and flicker measurement in Austria Discussion flicker - lamp type Application of wide area PQ monitoring in Austria Unified PQ-index for benchmarking Towards Voltage Quality Regulation in Europe An ERGEG Conclusions Paper 2

Long term monitoring of power quality Selected results from long term monitoring of power quality in Austria Flicker Harmonics Power quality measurement results by Association of Austrian Electricity Companies (VEÖ) VEÖ-Journal, April 07, Spannungsqualität: Koordinierte Messungen österreichischer EVU, Teil XIII/XIV, p.38-41 Power quality measurement results from regional grid operator 3

Long term monitoring of power quality Power quality measurement by VEÖ random sample of measurement locations each year one week in summer, one week in winter no. date participating grid operators LV MV HV 1 6/2000 17 24 8 8 2 1/2001 15 34 9 11 3 6/2001 12 31 9 10 4 1/2002 12 34 17 11 5 6/2002 14 41 21 12 6 1/2003 13 38 20 17 7 6/2003 8 14 4 9 8 1/2004 14 33 10 11 9 6/2004 15 51 30 8 10 1/2005 15 47 30 9 11 6/2005 15 63 32 9 12 1/2006 12 47 29 11 13 6/2006 12 50 28 10 14 1/2007 14 47 30 11 Power quality measurement by regional grid operator continuos power quality measurement since 2002 7 MV locations, 7 LV locations 4

Harmonics Harmonics in LV, 95% quantile of VEÖ measurement 6/2000 1/2007 5

Harmonics Harmonics in MV, 95% quantile of VEÖ measurement 6/2000 1/2007 6

Harmonics Harmonics in HV, 95% quantile of VEÖ measurement 6/2000 1/2007 7

Harmonics THD in LV, weekly 95% quantile, regional measurement 4 3.5 3 2.5 2 1.5 1 0.5 0 0 20 40 60 80 100 120 140 160 180 200 2002 2004 2006 8

Harmonics THD in MV weekly 95% quantile, regional measurement 4 3.5 3 2.5 2 1.5 1 0.5 0 0 20 40 60 80 100 120 140 160 180 200 2002 2004 2006 9

Harmonics THD is dominated by 5 th harmonic Clearly decreasing trend for 5 th harmonic and THD Constant level for 7 th, 11 th, 13 th harmonic More electronic devices in operation, less power for individual device larger variation of phase angle, especially for 5 th harmonic 10

Flicker Results from VEÖ measurement, LV, no trend published LV Plt 1,02 Pst 0,91 11

Flicker PST, weekly 95% LV, regional measurement 3 2.5 2 1.5 1 0.5 0 0 20 40 60 80 100 120 140 160 180 200 2002 2004 2006 12

Flicker PST, weekly 95% MV, regional measurement 07 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 20 40 60 80 100 120 140 160 180 200 2002 2004 2006 13

Flicker Disturbing limit: Slovenian study: Complaints starting with Pst 1.3 Changes in lighting technology: From Nov 2008, the importation of non compliant lighting (including incandescent globes) into Australia will be banned and from Nov 2009 the retail sale of non compliant lighting (including incandescent globes) will be banned. The UK announced plans to phase out the sale of incandescent light bulbs by 2011. Italy will ban the sale of incandescent light bulbs as of 2010. The European Union has proposed a ban on incandescent light bulbs, planned to come into effect in the near future. Adaptation of flicker limit Adaptation of measurement procedure (filter) (like IEC 61000-4-15 for 110 V-lamps 14

Flicker Adaptation of measurement procedure (filter) 2 1.5 1 H L 05 0.5 0.2 incandescant IL60 lamp 230V/60W halogen HL20lamp, 12V/20W fluorescent FL36indlamp, 230V/36W, ind. ballast energy ESL11 saving lamp, 230V/11W 0.1 0.1 0.2 0.5 1 2 5 10 20 35 f m [Hz] source: Hennerbichler, TU Vienna 15

PQ monitoring Permanent wide area measurement of power quality: low voltage level excluded serve the long-term observation of the power quality show possible development trends find specific values that characterize the power quality of a network Legal base in Austria: Elektrizitätsstatistikverordnung 2007 (electricity statistics regulation 2007) 13. Grid operators are obliged to record power quality - area-wide for MV grids, using appropriate statistic ti ti method - spot sample for LV grids - measurement period from 1.1. 0:00 to 31.12. 24:00 (=permanent) 16

PQ monitoring Challenge for economic reasons: Minimum number of necessary measuring devices Optimal mounting place Avoid redundant measuring results and information loss Parameters to be considered: network topology (radial network, meshed network) network impedance (line length, cable, overhead line) disturbing dstub gsouces sources single, independent disturbing sources with high rated power evenly distributed disturbing sources with similar characteristics disturbances from superior HV grid 17

PQ monitoring Grid calculation based on grid s admittance matrix creation of synthetic time courses of disturbing currents for each node calculation of distorted voltage Correlation and regression analysis of all combinations of calculated voltage time courses due to correlation and regression applying limits for correlation coefficient and regression coefficient results in binary matrix Determination of optimal measuring location minimizing number of measuring devices checking infrastructure of locations (PT available, communication facilities) 18

PQ monitoring Example harmonics V h Harmonic voltage I h harmonic current from disturbung load Z grid s impedance matrix creation of synthetic harmonic current time course (10-min rms values for a week) based on customer structure calculation of harmonic voltage time course with impedance matrix applying correlation and regression analysis to all combinations of voltage time series to detect similar measurement results 19

PQ monitoring Combination of binary result matrices from correlation and regression analysis regression coefficient correlation coefficient Regressionskoeffizient Korrelationskoeffizient 0.8 < 0,8<a a 1 < 1.25 <1,2 r > 0.8 r>0,8 1 A A A B B B C C C D & D D = E E E F F F G G G xy Adequate sorting of nodes in matrix Determination of clusters with similar behaviour Number of clusters equals minimum number of measurement devices 20

PQ monitoring UW Suggested measurement locations Möglicher Messknoten Nodes with sufficient i correlation to suggested measurement Korrelierender locations Knoten 21

Measurement results In 2004 an Austrian grid provider started to install an area wide power quality monitoring system. Meanwhile 200 measuring devices were positioned accordingly to the results of the study in 40 MV grids of the above mentioned grid operator. The proposed method achieved a coverage of about 18 to 60 stations by one measuring device After one year successful operation it is possible to evaluate the developed method according to its ability to cover up the area-wide power quality. This evaluation resulted in further approvements of the algorithm. 22

Measurement results Examples for measured time courses (5th harmonic) 4 4 4 2 2 2 0 Mon Tue Wed Thu Fri Sat Sun 0 Mon Tue Wed Thu Fri Sat Sun 0 Mon Tue Wed Thu Fri Sat Sun 4 4 4 2 2 2 0 Mon Tue Wed Thu Fri Sat Sun 0 Mon Tue Wed Thu Fri Sat Sun 0 Mon Tue Wed Thu Fri Sat Sun 4 4 2 2 0 Mon Tue Wed Thu Fri Sat Sun 0 Mon Tue Wed Thu Fri Sat Sun 23

Measurement results 2 main characteristics identified: 5 th harmonic level dominated by housholds, high level in the evening (TV prime time) and on weekends, lower level during working hours 5 th harmonic level dominated by (light) industry, constant high level during working hours, decreasing level during evening and weekend From theory, single phase power electronic devices (household, h office) and three phase power electronic devices (industry) show 150 phase shift in 5th harmonic current, leading partly to cancellation. Basic knowledge of customer structure which means basic knowledge of the harmonic current phase angle - is required 24

Revision of method Revision of method: - improvement in consideration of influence of high voltage grid - improvement in consideration of harmonic current of phase angle - improvement in assumption of fluctuating load currents causing flicker results in better consistency of simulation and real measurement results decreased number of necessary measurement devices 25

Modification of method Messknoten D Messknoten F Messknoten E Messknoten A Messknoten C 9 clusters in MV grid with 220 MV/LV transformer Messknoten B 26

Modification of method Messknoten D Messknoten F Messknoten E Messknoten A Messknoten C Messknoten B 9 clusters in MV grid with 220 MV/LV transformer 27

Statistical results Time range Statistical evaluation, distribution of approx. one year measurement (52416 values) Statistical evaluation, distribution of one week measurement (1008 values) Analyzed parameters flicker (P st -values) harmonics (5 th harmonic, 10 min average values) Typical no normal distribution, statistic methods based on normal distribution might lead to wrong results 28

Statistical results Flickerlevel, approx. one year measurement no. of 10 min values: 52416 5 th harmonic, approx. one year measurement no. of 10 min values: 52416 8000 µ = 0.108 7000 σ = 0.060 p = 0.000 % 6000 5000 4000 3000 1000 800 600 400 µ = 0.632 σ =0237 0.237 p = 0.000% 2000 1000 200 0 0-0.5 0 0.5 1-1 0 1 2 P ST H 5 in % ST 5 29

Statistical results Flickerlevel, one week measurement no. of 10 min values: 1008 5 th harmonic, one week measurement no. of 10 min values: 1008 200 150 µ = 0.101 σ = 0.050 p = 0.000 % 140 µ = 0.890 σ = 0.310 120 p = 0.000 000 % 100 100 80 60 50 40 20 0-0.5 0 0.5 0-1 0 1 2 P ST H 5 in % 30

Combining results (Perrera) 31

Data compression Continuos measurement: 3 phases x (P st + 40 harmonics + THD + unbalance + voltage level + frequency) x 1008 10min-values = 136080 values/week,instrument Additional: event triggered measurement data compression is necessary! - compression in time domain - local compression - combining of PQ-parameters Publications: University of Wollongong (S. Perera e.a.) 32

Data compression 1. Compression in time domain: level 1: level 2: level 3: 10 min average weekly 95% quantile annual value, mean/maximum value of weekly 95% quantiles 2. Local compression: level 1: cluster, containing 1 instrument level 2: level 3: level 4: MV-grid, containing several cluster grid operator, operating several grids nation wide parameter Compression method: mean/max value of weekly 95% quantiles, weighting according power, no. of customers,... 33

Data compression 3. Combining of PQ parameters Scaling to pu-values, refer measurement values to power quality limits Combining of parameters, calculating Unified Power Quality Index UPQ with specific weighting parameters a i (specification needs a lot of discussion) mean value UPQ = i a i PQ n i maximum value { } UPQ = max a PQ i i Gosbell, Perrera { i i} max { i i} ( ) max { } max a PQ für a PQ < 1 UPQ = 1 + PQi 1 für ai PQi 1 i 34

Unified Power Quality Index Possible use of the Unified Power Quality Index Chance for regulation authorities to detect and quantify power quality problems also without deep knowledge Benchmark for comparison of different grids within a country Benchmark for international comparison Measure for use in regulation formula (power quality regulation) 35

ERGEG Conclusions Paper Towards Voltage Quality Regulation in Europe An ERGEG Conclusions Paper July 2007 based on: - Public Consultation Paper: Towards Voltage Quality Regulation In Europe - Evaluation of the Comments Received 36

ERGEG Conclusions Paper Main focus: revision of EN 50160 Improve definitions and measurement rules Close gaps (e.g. between dips and voltage variation) Definition of rapid voltage changes Definition of interruption Limits it for voltage variation 95% -> 100% Enlarge the scope of EN 50160 to high and extra-high voltage systems Usually very specific Consider duties and rights for all parties involved 37

ERGEG Conclusions Paper Avoid ambiguos indicative values for voltage events Introduce limits for voltage events differentiated according to the network characteristics Analysis of influencing factors: - under control of grid operator (protection system, ARC, maintenance,..) - out of control of grid operator (regional lightning density, snow,...) Power quality contracts Scope of EN 50160? 38

ERGEG Conclusions Paper 39

ERGEG Conclusions Paper 40

ERGEG Conclusions Paper 41

Contact Dr. Herwig Renner Graz University of Technology Institute for Electrical Power Systems herwig.renner@tugraz.at t www.ifea.tugraz.at 42