Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Similar documents
On-line PD Monitoring Makes Good Business Sense

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

Predictive Maintenance in a Mission Critical Environment

Electrical Predictive and Preventative Maintenance

Electrical Distribution Services from Schneider Electric

Predictive Maintenance

Electrical Distribution Services for Mining and Metals Industries

electrical services

WHAT IS INFRARED (IR) THERMOGRAPHY

A Practical Guide to Maximizing Machine Uptime

21 st Century Facilities

Ultrasound Condition Monitoring

Risk Mitigation of Aging Electrical Infrastructure

GE Energy Transformer Monitoring: How Moving forward from Monitoring to Diagnostics can Positively Impact Indian Business and Industry

Arc Terminator Active Arc-Resistant Switchgear

employed to ensure the continuing reliability of critical systems.

Electrical Maintenance Workshop

Monitoring and diagnostics

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Electrical Network Management System

THE VALUE OF POWER FACTOR TESTING

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Arc flash can kill. Arc flash can be considered as a short circuit through

Engineering innovation

Effective Condition Assessment of Medium Voltage Switchgear

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Extend the Life of Existing Switchgear

DISTRIBUTION OPERATIONS AND MAINTENANCE

On-line monitoring of substation condition a Romanian experience. V. ZAHARESCU, Vl. ROSCA Nova Industrial SA. CN Transelectrica SA Romania

13 common causes of motor failure

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Safe and secure distribution of medium voltage with AX1

DGA - Method in the Past and for the Future

Appendix B Audit Forms for PdM Program Assessment

Dissolved Gas Analysis Guide for Transformers Filled with Beta Fluid

Nuclear Power Plant Electrical Power Supply System Requirements

Arc Flash Energy Mitigation Techniques

COMMON EQUIPMENT FAILURES AND CAUSES. How breakdowns can impact the bottom line. A handy reference guide from Hartford Steam Boiler.

How To Use A Power Supply Unit (Upu)

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Hydro Plant Risk Assessment Guide

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Condition Monitoring of equipment to improve quality of supply to customers by averting failures

Technical Electrical Field Service Support. Knowledge + Experience = Power. Field Service

Siemens TMDS transformer monitoring and diagnostic system. Solutions for transformer life-cycle management. Answers for energy.

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

Alstom Grid Services. Transformer lifecycle management GRID

ACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES

PD Monitor GIS. 24/7 Partial Discharge (PD) monitoring system for Gas Insulated Switchgear. Benefits NEW PRODUCT

14. Troubleshooting Guide

Fusible Disconnect Switch

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Practical Transformers: Operation, Maintenance and Testing

Energy Transmission and Distribution Services

AC-Synchronous Generator

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Standard for an Electrical Preventive Maintenance (EPM) Program

User s Manual AURORA 1.2K/2.2K

ON-LINE DIAGNOSTIC CASE STUDY INVOLVING A GENERAL ELECTRIC TYPE U BUSHING

uptimeplus.co.uk predictive maintenance strategy galileo Supported by

Understanding Arc Flash

New standardized approach to arc flash protection

EVALUATING WAVE FILES TO DETERMINE THE SEVERITY OF THE ULTRASONIC EMISSIONS

SIEMENS Transmission and Distribution

Understanding Insulation Resistance Testing

Data Center Solutions. Envirotran HDC Transformers Deliver Superior Reliability and Efficiency for Substantial Savings Everyday

Advanced Distribution Grid Management for Smart Cities

Evaluating Fire- and Heat-Damaged Electrical Equipment

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

Lastest Development in Partial Discharge Testing Koh Yong Kwee James, Leong Weng Hoe Hoestar Group

Power plant safety: a wise business move

Statement Of Work. Data Center Thermography Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Evaluating Water-Damaged Electrical Equipment

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

Use your troubleshooting superpowers for good Application Note

Common Power Problems & Power Protection Solutions

Power-factor testing of rotating machinery is another valuable test

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Transformer Fleet Management with e-terraassetcare

Power Monitoring for Modern Data Centers

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Offshore oil platform power and control system

Primary and Secondary Electrical Distribution Systems

Power-Zone 4 Arc Resistant Low Voltage Switchgear

How To Test For Safety On A Power Cable

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

Single Phase UPS Management, Maintenance, and Lifecycle

Response, Reliability and Results in the delivery of leak detection services

Online Hydro Machinery Monitoring Protection, Prediction and Performance Monitoring Solutions

Transcription:

Enhance Power Equipment Reliability with Predictive Maintenance Technologies November 2012/1910DB1208 by S. Frank Waterer, Electrical Engineerinig, Fellow Schneider Electric USA, Inc. Make the most of your energy SM

Summary 1.0 The Importance of Electrical Equipment Maintenance...3 2.0 Approaches to Electrical Equipment Maintenance...4 3.0 What is Predictive Maintenance?...4 4.0 Predictive Maintenance Technologies...5 4.1 Power System Assessments...5 4.2 Infrared (Thermographic) Inspections...5 4.3 Online Temperature Monitoring...6 4.4 Oil Analysis...6 4.5 Partial Discharge Monitoring...7 4.6 Circuit Monitor Analysis...7 4.7 Intelligent Protective Devices...8 5.0 Benefits of a Predictive Maintenance Program...8

1.0 The Importance of Electrical Equipment Maintenance A comprehensive preventive maintenance and testing program should incorporate all electrical power distribution equipment, regardless of the manufacturer, to ensure that all electrical equipment and components operate safely and reliably as originally designed and intended. The ultimate goal is to minimize equipment malfunction, power outages, or interruptions to operations or service. An effective and reliable electrical installation is critical to any operation. Studies of electrical equipment maintenance show a strong correlation of maintenance level to reliability. The rate of electrical component failures is three times higher in facilities that do not perform preventive maintenance. - Source: Institute of Electrical and Electronics Engineers (IEEE) Routine maintenance verifies proper functionality, both electrically and mechanically. Protective devices are to help ensure safety for people and assets. The 2012 edition of NFPA 70E references NFPA 70B and now requires an Electrical Preventive Maintenance (EPM) program with documentation. The Liberty Mutual Research Institute for Safety reports that electrical injuries are the second most costly worker s compensation claim. Electrical equipment should be installed, operated, serviced, and maintained only by properly trained and qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Following are the most common causes of electrical equipment breakdowns:* Mechanical Failure Loose connections, overheating, load changes and/or additions Environmental conditions Humidity, corrosive environments, dirt, or dust may require preventive maintenance more frequently than the OEM s recommended schedule Work Improperly performed OSHA and NFPA require electrical equipment maintenance to be performed by qualified personnel * Source: Hartford Steam Boiler Inspection and Insurance Company White paper on Predictive Maintenance Technologies 3

2.0 Approaches to Electrical Equipment Maintenance Depending on the process, operating environment or age of equipment, companies may adopt one or more of the following maintenance strategies: Reactive Maintenance Repair work conducted after a failure or breakdown, often completed as an emergency The most costly of all maintenance strategies Preventive Maintenance Routinely performed maintenance, regardless of the condition of the equipment May be unnecessary, based upon the equipment s condition Specified list of inspections, cleaning, testing and part replacement Less expensive than reactive maintenance, but more costly than predictive maintenance Predictive Maintenance (or Periodic Diagnosis) Scheduled based on diagnostic evaluations Factors such as equipment age, environmental stresses, criticality of equipment, utilization, etc. affect decisions concerning maintenance schedule Provides significant reduction in equipment-related incidents Least expensive maintenance strategy An efficient maintenance strategy will identify the type and amount of maintenance to be performed as well as the frequency for maintenance activities to be carried out. on each piece of electrical distribution equipment. The True Cost of Downtime Every facility should know what the monetary impact of an unplanned outage means to their respective operations. However, when an event happens, the focus is usually on restoring power as fast as possible and at all costs. Often, the tangible and intangible costs are not accounted for during the event. The best way to avoid this financial impact is to reduce the risk of an unplanned outage, which requires time, effort, planning and money. 3.0 What is Predictive Maintenance? Predictive maintenance technologies enable companies to perform an effective amount of maintenance at an appropriate or practical time. Often referred to as condition-based maintenance, predictive maintenance tools monitor the condition of in-service equipment, either continuously (online) or at periodic intervals. Disruptions to facility operations can be reduced, since many predictive maintenance technologies are performed on inservice equipment. Having regular access to the current state of the equipment provides valuable information to determine when maintenance should be performed. From a cost-effective standpoint, it should take place before the equipment loses optimum performance. Conditions that can be monitored in electrical equipment include: Transformer Temperature, SF 6, insulation breakdown Tap Changer Operating time Circuit Breaker Opening, closing time, available magnitudes of I²t energy Switchgear Temperature of connections, insulation condition Motor Starting time, number of operations, power, insulation breakdown Cable Connections Insulation breakdown Monitoring the condition of equipment provides trending data to help anticipate and plan future maintenance activities. 4 White paper on Predictive Maintenance Technologies

4.0 Predictive Maintenance Technologies 4.1 Power System Assessments Power system assessments are often the first inspections performed since equipment was originally installed. Completed by professional electrical engineers trained in power system analyses, power system assessments provide for visual inspections of portions or all of the existing power distribution system. Power system assessments determine the electrical and mechanical health of the electrical equipment and power distribution system and how long they will likely continue to function as originally designed and intended. Defects, deficiencies, deteriorations, hazards, or weaknesses in existing electrical power distribution system installations are also identified as part of a power system assessment. Issues discovered as a result of the assessment are prioritized based upon one of four factors: 1. The safety hazard to electrical workers 2. The impact of the occurrence to key process elements 3. The probability of an occurrence 4. The ability to respond quickly to correct the negative effects of the occurrence (vulnerability) Power system assessments can be customized based upon the need to reduce risk to your facility from reliability issues, process disruptions, code violations and/or outdated workplace safety requirements. 4.2 Infrared (Thermographic) Inspections Infrared inspections use an infrared camera to detect anomalies not noticeable to the naked eye. In an electrical setting, infrared inspections identify hot spots, which can be a precursor to equipment malfunction, which leads to unplanned downtime. Heat rise in electrical equipment can be the result of: 1. Poor or loose electrical contacts or connections 2. Unbalanced electrical loads 3. Defective components Having infrared inspections routinely performed may qualify a company for reduced insurance premiums. Infrared Windows Enhance Safety Since infrared inspections are performed while equipment is on-line, equipment covers typically need to be removed. Having infrared windows installed in equipment panels enables permanent access for inspection of electrical components without disturbing operations. The window is made of a glass-like material that is transparent to infrared rays and allows hot spots to be registered by a thermographic camera. White paper on Predictive Maintenance Technologies 5

4.3 Online Temperature Monitoring Online temperature monitoring technology provides 24/7 access to critical connection points where traditional thermography cannot be used. Continuous monitoring provides the means to evaluate the equipment s current condition and detect abnormalities at an early stage. Conduction problems caused by loose connections or deterioration of contact surfaces result in a local temperature rise, which contributes to the reduction of the contact quality. Thermal runaways induced by conduction problems deteriorate the insulating material and cause disruptive dielectric discharges resulting in arcing faults. How it Works: During a planned outage, wireless temperature sensors are installed in low-voltage and medium-voltage equipment* in areas usually not accessible with an infrared camera. Utilizing wireless technology eliminates the need for special cables and provides lower installation costs than other types of online condition monitoring equipment. Temperature data is transmitted from the sensors to a nearby receiver via radio frequency signals. The receiver is connected to a computer via serial or Ethernet. The data can be alarmed on, compiled, analyzed and reported by a dedicated software package or via a SCADA program with Modbus TCP connectivity. Photo shows the placement of temperature monitor sensors attached to service entrance bussing. * Sensors can also be installed on equipment with high arc flash ratings, allowing equipment condition to be monitored without a risk of danger to personnel or equipment. 4.4 Insulating Fluid Analysis This predictive maintenance technology measures the physical and chemical properties of oil in an oil-filled transformer. Since transformers represent a substantial investment in a company s electrical distribution system, they must be maintained properly to maximize their reliability. An oil analysis can detect the breakdown of the oil paper insulating system along with a variety of other potential issues. Common tests performed on electrical insulating oils include: Moisture Content Increased moisture content can negatively affect the insulating properties of the oil and cause dielectric breakdown. Acid Number As oil degrades, it produces charged by-products including acids and hydroperoxides that adversely affect the oil s insulating properties. Dielectric Strength This is the maximum voltage that can be applied across the fluid without electrical breakdown. A significant reduction in the dielectric strength may indicate the oil can no longer perform as intended. Power Factor In transformers, a high power factor is an indicator that the insulating oil has a significant power loss, usually caused by contaminants (water, oxidized oil or degrading cellulose paper). Dissolved Gas Analysis (DGA) Concentrations and ratios of certain gases in the oil may be indicators of operational problems with the transformer. Two examples are shown below: High levels of carbon monoxide in relation to other gases may be a symptom of thermal breakdown of cellulose paper. High hydrogen levels, in conjunction with methane, may point to a corona discharge within the transformer. Possible issues can be discovered in time and outages can potentially be avoided. In addition, an efficient approach to maintenance can be adopted and the optimum intervals determined for oil processing, repairs or replacement. 6 White paper on Predictive Maintenance Technologies

4.5 Partial Discharge Monitoring Partial discharge is a leading indicator of insulation breakdown and occurs in electrical equipment under high voltage stress, usually greater than 2,000 V. The higher the voltage, the higher the potential for damage or downtime. Specifically, partial discharge is a localized electrical discharge in an insulation system that does not completely bridge the electrodes. As insulation systems age, they become more susceptible to breakdown. Continuous monitoring provides early warning alarms to help prevent equipment damage or downtime. Technology is available to detect and notify facility engineers of impending insulation breakdown. Partial discharge monitoring is applicable on equipment rated 5 kv to 500 kv where the age of the insulation could be cause for concern. Specific equipment applications include: Metalclad switchgear and switches: 5kV and 15kV Motors and generators 2.4kV Large power transformers and bushings Substation yard structure-mounted voltage transformers and current transformers Generator step-up transformers and bushings How it Works: Sensors are installed to equipment during a planned outage. They are wired to a monitoring unit, which can be tied into an existing SCADA system via open protocol (web hosting is also available). The sensors monitor: Magnitude (mv or pc) - Size or volume of the deficiency Pulse Count (PS) - Number or growth of deficiency Intensity / Power (mw) - Destructive power of the partial discharge events Signature - Includes phase of deficiency as well as type of deficiency Monitored results are evaluated and compared against an existing database. Trending data helps anticipate and plan future maintenance activities. Photo shows connection of a partial discharge sensor into the capacitive coupler port of a high voltage transformer bushing. Photo shows clear indications of corona tracking due to damaged insulation laminate on bussing and long term electron tracking prior to a phaseto-ground fault condition. 4.6 Circuit Monitor Analysis Circuit monitors record data relating to voltage, current, and power. They also offer a full-range of power quality features to help facility managers and engineers understand where and when dangerous and destructive transients, sags and swells occur. These include: Wave form capture and wave shape analysis Disturbance recording Disturbance direction detection Transient Analysis Some circuit monitor models can provide data on other utilities, including gas, compressed air, water, and steam to help management control operating costs. Whether addressing operational or power quality, circuit monitors have the capacity to diagnose potential problems to minimize downtime. White paper on Predictive Maintenance Technologies 7

4.7 Intelligent Protective Devices Circuit Breakers Electronic trip units or separate monitors can provide intelligent information regarding the circuit breaker s status, which include: General Condition: Identification, position, number of operations, cumulative interrupted currents, integrity of interrupting medium for medium-voltage (SF 6 or vacuum) Mechanical Condition: Operating times, charging time, travel-time curve, excess closing energy, wear of contacts Control Circuit / Auxiliaries: Supply voltage; supervision of trip coil circuit, of sensors circuit Provides advanced planning ability as condition-based activity instead of routine maintenance Motor Control Centers Intelligent motor starters allow cost-effective monitoring of motor current and power. Motor control centers are upgraded and networked into a centralized or distributed control scheme Digital display can be mounted on the door to minimize the need to open/close Motor run time can be easily tracked Intelligent monitoring functions include: Current: Thermal capacity, line currents, average current, ground current, motor temperature (sensor) and current phase imbalance Voltage: Frequency, line to line voltage, line voltage imbalance Power: Active and reactive power, power factor, active and reactive energy Electrical signature analysis can detect: Rotor bar damage Stator electrical faults Defective bearings Maintenance can be scheduled on an as-needed basis. Motor control center outages can typically be attributed to: Power Quality Voltage and Current Waveforms Harmonic Voltage Factor Voltage THD 5.0 Benefits of a Predictive Maintenance Program Industry trends point to reduced maintenance staffs and budgets as well as aging electrical equipment. Predictive maintenance provides costefficient solutions to maximize reliability and enhance workplace safety. Benefits of incorporating predictive maintenance technologies into a company s maintenance strategy include: 1. Determines the operational status of equipment 2. Evaluates present condition of equipment 3. Detects abnormal conditions in a timely manner 4. Initiates actions to prevent possible forced outages Monitoring the condition of equipment provides trending data to help anticipate and plan future maintenance activities, which saves time and money. According to the U.S. Department of Energy, independent surveys indicate the following average industrial savings or improvements when a functional predictive maintenance program is implemented: 10 times Return on investment 25-30% Reduction in maintenance costs 70-75% Elimination of breakdowns 35-45% Reduction in downtime 20-25% Increase in production 8 White paper on Predictive Maintenance Technologies

Schneider Electric USA 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7500 www.schneider-electric.com/us Document Number 1910DB1209 1910DB1208 November 2012 2012 Schneider Electric. All rights reserved.