Gas Meter Clearances and Service Installation Requirements



Similar documents
Gas Meter Clearances and Service Installation Requirements

ELECTRIC SERVICE GUIDELINES (For Indiana)

March 2015 GAS SERVICE HANDBOOK. Commercial/Industrial & Multifamily Developments. Form No (Rev. 15)

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

MOBILE HOME SERVICE REQUIREMENTS GAS

Electric Service Conversion Overhead-to-Underground. Minnesota

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

Underground Service Requirements and Instructions

SECTION 5 DRAFTING STANDARDS

Section 2 Gas Service

SHALLOW UTILITIES JOINT PROVISIONING GUIDELINES SCOPE

Gas Appliances and Gas Piping

June 2014 Electric Service Handbook

Residential Decks. Planning and Development Services Department

Beacon Hill Sewer District Standard Specifications

Please check with your local inspection authority for any additional requirements before installation.

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Underground Commercial Electric Service

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Fiberstars Mini Lighted Laminar Flow Fountains

The City of Basehor, Kansas

Specifications for Residential Property Owners Connection to New Public Sewer

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

2010 Residential Water Heater Replacement Check List

Contents General Requirements Location Size Inlet and Outlet Piping Protection Security Electrical Automatic Meter Reading (AMR)

SECTION SELECTIVE DEMOLITION

Arapahoe County Residential Water Heater Installation and Inspection Guide

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

June 2014 Electric Service Handbook

Mobile Home Pre-Inspection Checklist

new construction departments...

TABLE OF CONTENTS. PUD SERVICE TERRITORY & CONTACTS... Page 1. NEW SERVICE QUESTIONNAIRE... Page 2. GENERAL... Page 3

BUILDING PERMIT SPECIFICATIONS

Town House Center Highway North Huntingdon, PA 15642

Builder/developer gas service application

Vision Home Inspection

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

2. What building projects are exempted? (permit not required)

Electrical Service Guidelines

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Section TREE AND PLANT PROTECTION

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

GENERAL ELECTRICAL REQUIREMENTS

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Eric Six Heath Consultants Incorporated

Fiberstars Lighted Laminar Flow Fountain Installation Manual

GENERAL WIRING RULES FOR HOUSES

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Windbrooke Townhome Association, Inc. Maintenance & Service Responsibility Chart

New Commercial Service Application

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

Guidelines for Earthquake Bracing of Residential Water Heaters

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Trenching and Excavation Safety

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Utilities and existing services

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

SECTION SITE PREPARATION

IRRIGATION PUMPING Table of Contents - Section 900

SECTION EARTH MOVING

Ontario Electrical Safety Code - Info Sheet

SANITARY SEWER SERVICE CONNECTION INSTRUCTIONS

FY08 SEWER POINT REPAIRS BID TABULATION

Chapter 7 Plumbing Connections

Does Wall Township require an inspection by the building department on resale of a home?

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

October 5, 2015 Dear Client,

Elevating Your House. Introduction CHAPTER 5

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

COMMONLY USED RESIDENTIAL BUILDING CODES

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Installation of Underground LP-Gas Systems

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Close-Out Documents... 9

What to Expect From the Examination. How to Study the Plumbing Codes

Merrimac Municipal Light Department. Residential Developments Policy

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

Building Permit Application

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Residential Foundations and Basements

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Table 4.9 Storm Drain Inlet Protetion Applicable for

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Transcription:

March 2015 Gas Meter Clearances and Service Installation Requirements Builder/Owner/Developer Requirements Call PSE s Customer Construction Services 1-888-321-7779 or visit PSE.com/CustomerConstruction for more information. The clearances in this handout also apply to features on buildings adjacent to the building where the gas meter is located. Final grade of the service line route must be in place before the service line can be installed. If you are unable to meet the meter location requirements in this handout, contact PSE for further assistance. Puget Sound Energy reserves the right to designate gas meter locations so that they comply with PSE standards. For gas meter installations in Cle Elum and west of Cle Elum within Upper Kittitas County, see the Gas Meter Protection from Snow and Ice in Snow Country handout (Form 3736). Gas Meter Locations Locate gas meter on the front wall, or within the front 1/3 of the side wall, observing the corner clearance requirements detailed below. The area 3 feet in front of and 2 feet to either side of the meter set assembly must be free of any landscaping (bushes, fences, etc.) and other structures that restrict access to the meter set assembly. Gas Meter Clearances to Finish Grade (250 Meter Shown) Regulator A Fuel Line Location (Typical) Typical Regulator Relief Vent B Front 1/3 of Side Wall Front Wall Walkway Driveway Front 1/3 of Side Wall Finish Grade Meter Type 8I Min A Meter Width (Typical) 6I Min B Fuel Line Height (Typical) Meter Outlet Diameter 250 16I 32I to 36I 1I Typical Public Access 425 42I to 46I 1-1/4I 630 42I to 46I 1-1/4I 1000 26I 46I 1-1/4I Measuring Around a Building Corner Outside Corners The regulator relief vent (see diagram above) should be at least 12I from any outside corner. If the regulator relief vent is at least 12I from any outside corner, then there are no minimum clearances to features around the corner. If the regulator relief vent is less than 12I from any outside corner, then the minimum clearances specified in this handout must be maintained. Measure as if using a string. House/Building Building Inside Corners Clearance distances from the regulator relief vent or meter set assembly to the feature must be maintained in accordance with this handout. Measure as if using astring. House/Building Building Property <12I Plan View Meter Elevation View Property Plan View Meter Elevation View Page 1 of 6

Property Line Work Pit for Customer-Provided Trench and Backfill Work Pit Dimensions Trench to Building (Approx) 12I 48I (Approx) Gas Stubout 1/2 Yard Bedding and Shading Sand Sand shall be provided on-site by the customer and placed within hand-shoveling distance to the work pit for bedding and shading of direct-buried facilities. A larger work pit may require more sand (see backfill requirements in this handout). Sand shall be washed, clean, and free of debris or rocks larger than 1/4 inch. Line Conduit Customer provides and plugs conduit end. Gas Stub Marker Utility Provided Dig to 12I from the Gas Stub Marker Customer shall not expose the stub. If accidentally exposed, cover gas stub with 12I of sand. 20I to Deep Work Pit Cross-Section Gas Stub Marker Final Grade When digging work pit, leave 12I of dirt over gas stub end. Gas Stubout 48I Gas Stubout Service Line in Conduit Installations Line in Conduit Line in Conduit Installation Final Grade For Minimum Line Depth See Table at Right. 36I Max Cover 12I Typical (4I Min *) Min (To Excavated Dirt Pile) Backfill for Conduit See Requirements For separation requirements to other Utilities see Page 2 of the Gas and Electric Underground Service Installation Requirements handout (Form 3061) * TRENCH WIDTH EXCEPTION: When converting existing construction the minimum trench width acceptable is 4I. Service Line Direct-Buried Installations Backfill Requirements for Conduit Installations Backfill for Conduit: Soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 10I in diameter. Shading: None required above conduit. Bedding: None required below conduit. Line Depth Table for Conduit and Direct-Buried Installations Type Pipe Size Minimum Depth of Cover over Gas Residential Any Size 18I Commercial/Industrial 1-1/4I + Any Service in Snow Country (See Form 3736) Any Size Line Direct-Buried Line Direct-Buried Installation Final Grade For Minimum Line Depth See Table Above. 36I Max Cover Page 2 of 6 12I Typical Min (To Excavated Dirt Pile) Final Backfill for Direct Bury See Requirements 6I Sand Shading 4I Sand Bedding For separation requirements to other Utilities see Page 2 of the Gas and Electric Underground Service Installation Requirements handout (Form 3061) Backfill Requirements for Direct-Buried Installations Final Backfill For Direct Bury: The backfill layer above the sand shading shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8I in diameter. If the final layer contains rocks larger than 8I in diameter, then 12I of shading shall be placed over the gas service. Rocks larger than 10I in diameter are not permitted in the final backfill. Sand Bedding: The customer shall provide and install clean sand to a depth of 4 inches prior to gas service pipe installation. See diagram at left. Sand Shading: The customer shall provide additional clean sand in piles that are readily accessible near the trench. This shading sand is to be installed by the PSE crew after direct-buried gas line installation. Enough sand shall be provided so that the installation can be covered to a depth of 6 inches. See diagram at left. If customer-owned facilities will be included in the trench, please contact PSE or local power company directly for clearance requirements.

Meter and Service Connections Work Pit 4I to 5I Fuel Line Stub Typically Protrudes 4I to 5I Customer Provided Work Pit Dimensions Work Pit 48I to 60I from Fuel Line Stub Shutoff Valve Gas Meter Utility Provided Finish grade shall be clearly marked at fuel line stubout. Service Riser Fuel Line Stub FINISHED WALL 36I TYP (Approx) 20I to Deep Drainage Pipe 6I Minimum clearance should be maintained from gas service line. 48I to 60I (Approx) Gas Meter 12I Line Conduit GAS TV & TEL POWER Line Conduit Customer provides and plugs conduit end. 3/8I Pull Rope If Conduit is over 100 ft Typical 1/2 Yard Bedding and Shading Sand Sand shall be provided on-site by the customer and placed within hand-shoveling distance to the work pit for bedding and shading of direct-buried facilities. A larger work pit may require more sand (see backfill requirements in this handout). Sand shall be washed, clean, and free of debris or rocks larger than 1/4 inch. 12I Conduit Requirements for PSE recommends the use of conduit for all gas service installations. Conduit Installation Requirements Gas conduit runs over 100 feet long must have a 3/8-inch minimum diameter pull rope installed. Conduit bends shall be one long radius, single-piece sweeps (see table below). Fittings and elbows shall not be used because the joints prohibit service insertion. The sum total of the degrees of bends in the conduit run cannot exceed 180_. Conduit shall not cross in the trench. Yellow or white Schedule 40 PVC conduit used for gas service lines shall not be marked water, or any other utility. Service Line Typical Residential < 185i Typical Residential Services >185i and < 1000i Typical Residential > 1000i Typical Large Multi-Family & Commercial Services Conduit Size, Type, & Color 2I (minimum) Schedule 40 Yellow or White PVC 3I (minimum) Schedule 40 Yellow or White PVC 4I (minimum) Schedule 40 Yellow or White PVC 4I (minimum) Schedule 40 Yellow or White PVC Min. Bend Radius 36I 48I 60I 60I Minimum Conduit Bend Radius Preferred Trench Location When the Trench Must Pass Near Trees The preferred position for customer-provided trenching is as far as possible outside of the dripline of trees. If this is not possible, contact PSE s Customer Construction Services at 1-888-321-7779 for trench location and depth requirements. Page 3 of 6

Regulator Relief Vent Clearances from Building s Window Attic Vent Crawl Space or Garage Vent Soffit Vent 1i from Windows, Building Vents, and Fireplace Cleanouts Power Disconnect Doors Wall Switch Electric Outlet 1i Garage Doors from Electrical Components from Doors and Garage Doors Mechanical Air Intake s at Clearance Distance A (10 feet) A Appliance Intake and Exhaust s at Clearance Distance B (3 feet) B Bathroom Fan Vents Fireplace Cleanout Window/ Wall-Mounted Fan Window-Mounted Air Conditioner Dryer Intake/Exhaust Wall-Mounted Air Conditioner Mechanical Air Intake Furnace Air Intake/Exhaust Fireplace Air Intake/Exhaust s from Wall-Mounted Fans and Air Conditioners, and Appliance Vents and Intakes Page 4 of 6

Gas Meter Clearances from Building s GROUND LEVEL Air Conditioner or Heat Pump Generator or Transformer Open Flame or Permanent BBQ Incinerator Clearances from Padmounted Air Conditioners, Heat Pumps, Generators, or Transformers from Incinerators or Open Flame Devices Preferred Roofline 2i 2i NOTE: A clearance of 36 inches is required in front of the electric meter face. NOTE: Clearly mark buried ground rod. Water Spigot Communications Box GROUND LEVEL 18I 1i Grounding Rod Preferred from Water Spigots, and from Communications and Cable Boxes from Overhead- or Underground-Fed PSE Electric Meters Gas Meter Clearances Under Porches, Decks, and Balconies Minimum Clearance from Grade Below Meter to Deck Bottom Minimum Clearance from Grade Below Meter to Deck Bottom 6i 6i Under Decks and Porches (meter must not be located under stairs or anywhere between doors and stairs) Under Balconies (no stairs to ground level) Page 5 of 6

Guard Post Installation (PSE s Responsibility) To protect meter set assembly from vehicle damage, PSE will install guard posts when required. To avoid the need for PSE to install guard posts, choose a meter location that is away from driveways or other areas where vehicles travel. Guard post requirements are based on the following factors: Existing barriers (curbs, guard rails, steep increases in grade, ditches, rockeries, trees, shrubs, chimneys, recessed walls, etc.), which will provide adequate protection; Proximity of the facility to the edge of the travel lanes; The expected speeds in the travel lanes; The width of the travel lane; The volume of vehicle traffic; Existing nearby building damage or other indicators of vehicle damage that may have already occurred; and, The type of customer (i.e., single-family residential versus commercial/industrial or multifamily). In cases where a meter set assembly will be installed behind a curb, observe the following: If the curb will be a rolled curb, and if there is less than 10 feet of space between the curb and the meter, guard posts will be installed; and, If the curb will have a vertical face, and if there will be less than 5-1/2 feet between the curb and the meter, guard posts will be installed. Guard posts will be painted caution yellow, especially those located in commercial or industrial locations, street rights-of-way, and alleyways. Typical Single-Family Guard Post Installation 2-1/2I Dia steel pipes filled with concrete Gas Meter Assembly 42I Min above grade Driveway or parking area Building Wall 8I 8I 8I Edge of MSA Edge of MSA Do not install centerline of guard posts in shaded area. 30I Underground concrete base Edge of MSA TOP VIEW EXAMPLE OF GUARD POST LOCATIONS THAT PROVIDE PROTECTION FROM ALL POSSIBLE DIRECTIONS OF VEHICULAR TRAVEL Guard Post 1 Concrete Base 3 Minimum Clearance between Meter Set Assembly & Guard Post 5 Single-Family Residence Commercial/Industrial or Multi-Family Legal Speed Limit Greater than 35 MPH 2-1/2I Dia. 4I Dia. 6I Dia. 2 8I Dia. x 30I High 15I Dia. x 30I High 30I Dia. x 42I High 4 8I 12I 12I! Guard posts shall be made from steel pipe, 6 feet long, filled with wet concrete and domed on top. @ In this installation, the guard post can be solid concrete 9 inches in diameter. # At least 24 inches of the guard post shall be embedded in the base, with at least 42 inches of the post above final grade. $ In this installation, at least 26 inches of the guard post shall be embedded in the base, with at least 42 inches of the post above final grade. % Additional guard posts are required if the centerline spacing between guard posts exceeds 36 inches. The additional guard posts are typically evenly spaced between the outer two posts. Page 6 of 6 E2015 Puget Sound Energy 3885 03/15