REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter



Similar documents
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Ubiflex. Non-lead flashing system

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Cupa Natural Slate Roofing design and fixing guide

Epdm Flat Roofing Systems

Including. Rubershield-Pro. Breather Membrane

Ridge. Hip. Abutment. Eaves. Roof slope. Vertical slating. Clay plain tiles. Valley. Ridge Roll. Verge. Bedded verge.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

ROOFING ACCESSORIES GENERAL References. England and Wales

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Asphalt Shingle Application Requirements

How To Build A Gambrel Roof And A Gable End Roof

FUNCTIONAL REQUIREMENTS

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Under Tile and Slate Undersheeting System

Roofers Guide to Underslating Membranes

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012

THE REDLAND GUIDE TO BS 5534

ensure that they are conserved. It is not intended to give technical advice on repairs and maintenance

SHINGLE APPLICATION GUIDE

The formation of roof waterproofing details calls for

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

I n s u l a t i o n. Low Energy Low Carbon Buildings

VM ZINC : standing seam Guidelines for specification and installation

Shingle Installation Guide

Interlocking tiles and slates

How To Build A Roof Tile Deck

Guide to Safe Building Practices

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

EDW + FS, VS, VSE, GGL, GGU, GHL. EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS

When considering Roof drainage design the following should be taken into account:

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

NRCA s steep-slope manual is thoroughly revised for 2013

UBBINK SOLAR IN-ROOF SYSTEM

CI/SfB (4-) Rf9 January Dry fix and ventilation systems including UNIVERSAL accessories. Roofing product catalogue 45

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Directions For Applying Malarkey Laminate Shingles

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals Magnolia Ave. Chino, CA 91710

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Multi-layer Insulation Blanket for Roofs

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

Rain Penetration Tests on Manthorpe Mini Castellated Vent Tile with 15" x 9" Format Roof Tiles. Prepared for: Ben Hales

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Technology at its best. Benefits

RESIDENTIAL ROOF PERMITTING A REFRESHER WORKSHOP September 11, 2014

STANDING SEAM SHEET METAL ROOFING

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

SECTION STANDING SEAM METAL ROOFING

INSTALLATION OF A BAY WINDOW

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

Performance and Quality

Leaky Homes Financial Assistance Package (FAP) Repair plan example

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

PERGOLAS AND CARPORTS

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

Classic Products, Inc. ClickLock Standing Seam Installation Manual

ROOFING. Introduction

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Monarflex Vapour Control Layers

Roof Rehab (Roof truss) Classroom Activity

CI/SfB (Ff3) January Roofing design guide. Showing you the way. Redefining traditional products

SECTION PREFORMED METAL STANDING SEAM ROOFING

TRAINING OUTLINE FOR PART TIME BUILDERS

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

Bituminous Sheet Flat Roofs: Their repair and maintenance

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs.

application instructions


Clay Roof Tile Council. Vertical Tiling

Marley Double Roman. concrete roof tile. The classic double roman tile with the extra-bold roll. Manufactured in Gauteng and KwaZulu-Natal

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Detached accessory structures that contain no conditioned floor area are exempt.

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

Retrofitting an Insulated Cold Roof

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Your guide to home maintenance. Flat Roofs

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

RESIDENTIAL/COMMERICIAL ROOFING APPLICATION Date / / BUILDING PERMIT APPLICATION

Materials and Colors

780 CMR ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Shingle Roofing: What s below the surface is important

Transcription:

REDLAND DRY BONDING GUTTER Installation Instructions for Redland Dry Bonding Gutter

1 Introduction 1.1 TECHNICAL DATA Dimensions: 3 m long x 210 mm wide Material: Glass-fibre/polyester composite. Pitch Range: 17.5-60. No sealing or jointing material is required if the following overlaps are used for adjoining Redland Dry Bonding Gutter sections : Rafter Pitch Below 22.5 22.5-29 30-39 Over 39 Overlap 350 mm 300 mm 200 mm 150 mm 1.2 DESCRIPTION Redland Dry Bonding Gutter is a product designed for tiled pitched roofs where you want to weatherproof the junction between two different roof coverings. It is manufactured from glass-fibre/polyester laminates in a continuous process to two profiles: Dry Bonding Gutter for Low Profile Tiles (9580) with central upstand 70 mm, available in standard lead grey colour in 3 m lengths. Compatible with double lapped natural slates and fibre-cement slates, flat interlocking tiles including all Redland Slate Range tiles (Cambrian Slate, Landmark Slate 10, Richmond 10, Saxon 10, Mockbond Richmond 10, Mini Stonewold, Mockbond Mini Stonewold, Stonewold II) and Redland DuoPlain. Dry Bonding Gutter for High Profile Tiles (9578) with central upstand 100 mm, available in standard lead grey colour in 3 m lengths. Compatible with double lapped plain tiles including Redland Plain Tile, Heathland, Rosemary Clay, profiled interlocking tiles including all Redland Profile Range tiles (Cathedral Clay Pantile, Old Hollow Clay Pantile, Landmark Double Pantile, Landmark Double Roman, Grovebury, 50 Double Roman, Regent, Renown, Norfolk Pantile, 49 Tile), and metal profiled sheet. For other roof coverings please contact Redland Technical Solutions (Tel. 08708 702595) to check suitability. The Dry Bonding Gutters can be retro-fitted either into existing roofs or installed in new roofs. 1.3 STORAGE The Dry Bonding Gutters can be stored outside above the ground on a flat, clean and level surface. The profiles should be stacked such that crushing and distortion is avoided and for long or indeterminate periods of storage outside the Dry Bonding Gutters should be protected with an opaque weatherproof covering. Redland Dry Bonding Gutter Installation Instructions Page 1 of 5

2 Installation 2.1 GUIDANCE NOTES Redland Dry Bonding Gutters are suitable for both traditional cold roof and warm roof construction. They can be used wherever you want to join two different roof coverings on a pitched roof slope. Typical construction scenarios include, but are not restricted to, adjoining roofs over fire-break masonry party walls, and also nonfire-break walls. Typical construction details can be found in Section 2.2. It is important when constructing bonding gutter details that the roof tiles that abut the bonding gutter lie in an even and level plane at the same pitch as the roof tiles adjacent. Tiles that kick up where they meet the bonding gutter should be avoided as this can compromise the weathertightness of the roof covering at these junctions. The choice of Low or High Profile Dry Bonding Gutter will depend on the roof coverings to be joined; it is recommended that the Dry Bonding Gutter chosen reflects the deepest profile tile to be joined. It is also critical that all the tiles that abut the bonding gutter are nailed and/or clipped in accordance with the Redland fixing specification for the roof in question. 2.2 DRY BONDING GUTTER CONSTRUCTION DETAILING To ensure that the tiles adjacent to the Redland Dry Bonding Gutter lie in an even and level plane it is important to follow the construction details in this section. For situations where the Bonding Gutter is to be used over a fire-break party wall the underlay and tiling battens must be terminated either side of the mortar-bed fire-stop. When using 25 mm tiling battens the Dry Bonding Gutter is fixed to 6 mm WBP ply either side of the fire-stop. The thickness of the WBP ply required can be calculated as follows: WBP ply thickness = (Tiling batten thickness 19mm) Redland Dry Bonding Gutter Installation Instructions Page 2 of 5

For situations where the Bonding Gutter is to be used over non-fire-break walls the underlay can be carried through underneath the bonding gutter but again the tiling battens should be terminated either side of a central 6 mm WBP plyboard, into which the Dry Bonding Gutter is fixed. Redland Dry Bonding Gutter Installation Instructions Page 3 of 5

When using Redland Cathedral Clay Pantiles ensure on the side of the bonding gutter where the tiles abut either that the tiles abut uncut, or are cut at least 30 mm from crown of profile. Alternatively the WBP ply thickness can be increased to 12mm. 2.3 FIXING INSTRUCTIONS 2.3.1 INSTALLATION OF DRY BONDING GUTTER Establish the position of the Dry Bonding Gutter. Underlay and batten the roof in accordance with the construction details in Section 2.2. Position Dry Bonding Gutter onto established line and nail through outer flange into 6 mm WBP ply below at maximum 500 mm centres. When joining lengths of Dry Bonding Gutter use the minimum overlaps specified in Section 1.1. Redland Dry Bonding Gutter Installation Instructions Page 4 of 5

The slates and tiles should be laid as close as possible to or touching the central upstand on both sides with care taken to avoid any distortion and maintain the straight line appearance of the profile. Mark the centre line of the Dry Bonding Gutter and remove slates or tiles for cutting as required so as to maintain the correct bond of the slating and tiling. At the ridge a Rapid Flashing saddle should be dressed over the Dry Bonding Gutter. At the eaves ensure the Bonding Gutter projects 50mm over the fascia board to match the overhang of the slating and tiling. Where the tile nibs interfere with the Dry Bonding Gutter they should be removed. Ensure all tiles and cut tiles adjacent to the Dry Bonding Gutter are mechanically fixed in accordance with the Redland fixing specification for the roof. The standard nails and clips can be used. For half slates and other small cut tiles either Redland C-clip (9518) (shown adjacent), and/or Redland Kro-clips (551350) can be used. Complete the slating and tiling as required. Redland Dry Bonding Gutter Installation Instructions Page 5 of 5