Driver Installation and Hyperterminal Operation of iload Digital USB Sensors



Similar documents
Installing the Gerber P2C Plotter USB Driver

Title: ZOLL USB Direct Connect Cable Installation Instructions

Acton Research Technical Support SpectraPro Diagnostic Procedure

Supplemental USB Driver Installation Guide

USB Driver Installation for Windows XP

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

User Manual. Thermo Scientific Orion

USB DRIVER INSTALLATION GUIDE

ScanShell.Net Install Guide

Current Cost Data Cable User Guide. Installing and configuring the data cable

Omni 56K USB Lite Quick Start Guide

CANON FAX L360 SOFTWARE MANUAL

USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS. For. Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS

How to install USB driver (MICRO/I)

Transferring Scans from your Dolphin into Destiny

Running the R4 Software on a USB Port

Installation Instructions for 9555 USB Driver

USB DRIVER INSTALLATION GUIDE

Hi-Speed USB Flash Disk User s Manual Guide

Installation of USB Virtual COM. Version 1.02

Installing the drivers for the Current Cost Data Cable

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

Select Correct USB Driver

Installing PowerLink on Windows 7 64-bit

USB Driver. Installation Manual

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Print Server Application Guide. This guide applies to the following models.

Configuring the Switch with the CLI Setup Program

SatTerm-G SOFTWARE MANUAL FOR A3LA-IG

OMEGA STUDIO SOFTWARE INSTALLATION GUIDE

Install Device Drivers and Toolkit for Windows 7

JTAGjet. series SIGNUM SYSTEMS CORPORATION. USB 2.0 Driver for JTAGjet and ADM51. Installation Instructions

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

Printer Support Guide. FedEx Ship Manager Software

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

TBS Help Index / On Board Software User Manual

Addendum Advanced POS Printer Drivers

Connecting your Omega/BetaPAT PLUS to a PC via a USB

USB/RS485 Communication Cable Installation

WindO/I-NV2 Utility Pass-Through Tool

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

EASE Scan Tool Customers. SECTION I - Installation

TruePort Windows 2000/Server 2003/XP User Guide Chapter

Installation Instruction STATISTICA Enterprise Small Business

SAPIP GUI INSTALLATION. Table of Contents

Maintaining the Content Server

USB DRIVER INSTALLATION GUIDE

Metasys System Direct Connection and Dial-Up Connection Application Note

Colorfly Tablet Upgrade Guide

EVA Drivers 6.1 and TWAIN Installation Guide for EVA Classic Digital Sensors

How to install USB driver (MICRO/I)

CMP-102U. Quick Installation Guide

Motorola Phone Tools. Quick Start

AN220 USB DRIVER CUSTOMIZATION

Cypress CY7C64225 USB-to-UART Setup Guide Version 1.3

Note that you need to install the driver once on each laptop or desktop PC you use with the LP130.

Network Printing In Windows 95/98/ME

CODESOFT Installation Scenarios

SETUP GUIDE: MOON USB HD DSD Driver. MOON Nēo 340i D 3 MOON Nēo 350P D 3. MOON Evolution 780D. Musical Ecstasy. Date Code:

Keep it Simple Timing

Iridium Extreme TM Satellite Phone. Data Services Manual

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

B.11 Quick Guide #11: Installing a Printer (Refer to CAREpoint Users Manual Section 6 for more information)

HUMAC2009 Software Installation Instructions for Windows XP and Vista

Print Server Application Guide

Engineering Note. Correcting Device Driver Issues Product Affected: SpectraSuite, OceanView, OmniDriver, SPAM Software Date Issued: 3/16/2015.

Global Monitoring + Support

STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS

L Firmware And FPGA Configuration Upgrade

Network Setup Guide. Introduction. Setting up for use over LAN

PL2303HXA/XA Windows 8 Update Driver Installation. How to Update Driver to Support PL2303HXA/XA in Windows 8 Operating Systems

Software Manual Virtual COM for USB Driver / Configuration Tool

1 Installation. Note: In Windows operating systems, you must be logged in with administrator rights to install the printer driver.

Centurion PLUS CPC4 Download Guide

Chapter 1 Downloading Images to Your Computer (Windows)

64-Bit Compatibility with Micromeritics Applications

EPSON Stylus COLOR 740. USB Software Installation Guide (Windows 98/iMac ) USB Setup Guide (imac)

Guide to Installing BBL Crystal MIND on Windows 7

Installation Guide for RadioLabs USB Wifi Antennas/Adapters

EasyGate UMTS Data quick installation guide

Network/Floating License Installation Instructions

Congratulations on your purchase of a BPM Microsystems device programmer. Your new device programmer was designe d to provid e years of suppor t for

OfficeSuite Dialer Documentation

PP8X Printer Driver Installation Instruction

USB DRIVER INSTALLATION GUIDE

Installation Notes for Prolific PL-2303 USB Driver for USB - RS232 Adaptor Cable 1. Uninstall Existing USB-Serial Adaptor Drivers

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

IVS-Basic 4.4 IVS-Professional 4.4 IVS-PowerPoint 1.1

Installing the OKI MCx61MFP USB Attached, in Windows 8

Windows Driver Manual Label Printers

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

Virtual Serial Port over USB For PD & PC Series Printers

How to use the VMware Workstation / Player to create an ISaGRAF (Ver. 3.55) development environment?

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Using a USB to Serial adapter and Terminal Emulator in Windows 7 to communicate with a DM101

BioWin Network Installation

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software

Transcription:

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors Driver Installation Insert the iload Digital USB Driver CD OR the LoadVUE or LoadVUE Lite CD into your computer s drive. If you have downloaded the driver files from our web site onto a location in your hard disk, substitute that location instead of the CD drive in the instructions below. Drivers for Windows XP and Windows Vista are available here. If you have purchased LoadVUE or LoadVUE Lite software with your iload Digital USB sensor, please ensure that you install the drivers as described in this document before you install the LoadVUE software. Also note that the screen shots in this document are for Windows XP, but the process is the same with Windows Vista although the appearance of screens is different. Note: supply. The iload series sensors are intended for use with an NRTL approved device such as a computer or regulated power Plug in your iload Digital USB sensor into an available USB port on your Windows computer. The New Hardware Wizard window will come up in a few seconds. Select the option for No, not this time and click Next. On the next screen select the option for Install the software automatically option and click Next. Your computer should scan the CD to find appropriate drivers for the sensor.

On the next dialog box click Continue Anyway. Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 1 Windows installs the driver for your iload Digital USB sensor. Click Finish. The sensor will appear as a COM port to Windows whenever you plug it in to the same USB port on your computer. If you use a different physical USB port, you may need to go through this procedure again to associate a COM port with that USB port. However, you will usually not have to insert the CD again. To verify the COM port number that has been assigned to the sensor, open the Hardware Device Manager. You can do so by going to the Control Panel in Windows and double-clicking on System. On the System dialog box click on the Hardware tab and select the Device Manager button. When your iload Digital USB sensors is connected and correctly installed, you should see a COM port assigned to it as shown highlighted in the following screen shot (next page).

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 2 If you have more COM ports than you have sensors connected, you can double-click on the entry for a COM port. The ports associated with iload Digital USB sensors will indicate that they have a Loadstar Sensors driver as shown below. You are now ready to start using your iload Digital USB sensor. Hyperterminal Operation In Windows XP, launch the Hyperterminal program. Start...All Programs...Accessories...Communications...Hyperterminal Note: Windows Vista does not include a terminal client. However, free terminal client software like Teraterm is available.

Set up a new connection to connect to the iload Digital USB sensor's COM port. Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 3 In the "Connect To" window, select the appropriate COM port.

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 4 In the "Port Settings" dialog box, accept the defaults. The baud rate etc is not applicable to the iload USB sensors. Note: Since this is a virtual COM port via a physical USB port and not a real COM port, the settings for baud rate, data bits, parity, stop bits and flow control that must usually be set for a physical COM port are not required. Any setting will do. Click OK to accept the settings. Then click "Enter" a few times. You should see the sensor respond with an "A".

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 5 Type "O0W1" and hit <Enter>. The sensor will respond with the current load on the sensor in millipounds. In the figure below the load is 2.853 pounds. Type "CT0<Enter>" to tare the sensor. This will zero the load (all further readings will subtract the load sensed at this point.) Type "O0W0<Enter>" to output the load continuously. Hitting <Enter> at any time will stop outputting the readings.

Basic command set Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 6 The iload Digital USB sensor can be used through LoadVUE or LoadVUE Lite software from Loadstar Sensors. It can also be used directly as a COM port using any terminal emulation software such as HyperTerminal that is included with Windows XP. To set up Hyperterminal or other terminal emulation program to communicate with the sensor, select the appropriate COM port in the program and connect. Once connected, a few simple commands are all that are needed to operate the sensor: <Enter> CT0 O0W1 O0W0 O0S2 SLC SS1 SS0 This just pings the port and the sensor responds with A to indicate that it is set up and ready. This sets the tare (or zero) for the sensor. If you plan to zero out a preload, please use this command. The O0W1 command outputs the weight or force reading once. O0W0 outputs a continuous stream of weight or force readings. Simply send a <carriage Enter> to stop streaming. The output is in 1/1000 of a pound (millipound). E.g., if the reading returned is 2345, the sensor reading is equivalent to 2.345 lb. Outputs the temperature within the sensor in deg. C. Note that this is the temperature within the sensor and is usually a few degrees higher than ambient. This command outputs a floating point number that indicates the load capacity of the sensor in lb. This command outputs the last three digits of the serial number of the sensor. This command outputs the model number of the sensor.

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors 7 Writing Your Own Software to Communicate with iload Digital USB Sensors Since the iload Digital USB Sensors present themselves to Windows as COM ports, it is very easy to write your own program to read the sensor loads. Simply open the COM port from your application and send the string O0W1<CR>. Then read the returned string back in millipounds. We recommend the following steps: 1. Open the port at 9600 (baud rate is not important), N, 8, 1. 2. Write a <CR> to the port. 3. Wait for a few milliseconds (say, 100 to 1000, this depends on your hardware, try a longer wait first then shorten it to see what works. (An alternative is to wait until there is a required number of characters in the input buffer, in this way the wait time is reduced to a minimum). 4. Read the input buffer and discard till there are no characters to read. (You can check if you get an 'A' back) 5. Write O0W1<CR> to the port, 6. Wait again for a few milliseconds. 7. Read the input buffer and process. This will contain the weight. 8. Repeat Steps 5 to 7 as needed. 9. Discard any bytes left in the input buffer before you close the port. 10. Close the port. If callbacks (or events) are available, it is preferable to use them instead of polling the sensor in step 7 above. This way Windows will inform the application that there is data to be read. Examples for Labview and Matlab are available on our support pages.