PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.



Similar documents
How To Read A Pipe From A Sensor

Waterproof Connectors for Outdoor Use

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Adjustment functions for both span and shift have been incorporated

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Capacitive Prox E2K-X

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Cross-beam scanning system to detect slim objects. 100 mm in

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

3 Port Solenoid Valve

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Solid-State Timer H3G

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

400 Series Buccaneer BUCCANEER POWER. bulgin

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

Cables. Accessories. For Force, Torque and Strain Sensors

Absolute Rotary Encoder E6CP

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

400 Series - Mini USB Buccaneer

U-shaped Micro Photoelectric Sensor


.093 [2.36] Commercial Pin and Socket Connectors

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Knob Potentiometer with Switch

Mini USB and USB 2.0-IP67 Connector System

Cable Plug acc. to DIN EN , Form A

gesis IP + Heavy Duty Class I, Zone 2

Switches & Pilot Devices

Directory chapter 04

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Radiant Temperature Sensor TY7321

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

CQM1-SF200/CS1W-SF200

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Operating Temperature Range: -30 to +85ç (Note 1) Operating Humidity Range: 40 to 80%

Universal MATE-N-LOK Connectors

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TS93 EMR T/PT/TDE. Surface applied door closer

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

UTS discrete wire sealing

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Givare NC-SRS 280 och 880

AMPSEAL* Automotive Plug Connector and Header Assembly

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x

How To Power A Schen

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

08. SEK IDC CONNECTORS

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Inductive sensor NI10-M18-Y1X-H1141

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

SD Memory Card Connectors

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Now Available in Black Zinc Nickel

DCS Input/Output Relay Card Series

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

TECHNICAL DATASHEET Incremental Encoder RI 58-H

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

SERIES SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~

Industrial circular connectors

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

AZ420 MINIATURE GENERAL PURPOSE RELAY

Description. Dimensions. Features. precision works better

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Subminiature Load Cell Model 8417

Fakra. Coaxial connectors. DC 6 GHz

SOURIAU s discrete wire sealing

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

369 SERIES CONNECTORS

Small-diameter Proximity Sensor

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Series 6000 Torque measured metal bellow coupling

Model Number Structure

HERZ-Thermal Actuators

Magnetic Proximity Switches Series CST - CSV and CSH

Product Information. HMC 6 Hybrid Motor Cable

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Model Number Structure

Transcription:

Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor malfunction Simultaneous mechanical assembly and electrical wiring Perfect for flexible production lines Usable even in harsh environments exposed to cutting oil (IP67) PA COMBINATIONS Sensor side Wiring side (PA side) Connector type sensor Cable with female connectors Limit switch Proximity sensor Sensors with preleaded connector Cables with tandem connectors General sensors and actuators Cables with male connectors Standard basic switch Solenoid valve Pressure switch, flow switch, motor, etc. Connectors for panel mounting Mounting direction Panel 1

SELECTION GUIDE Example:PA-JSXHK-E PA- J SX HK - E Basic model number of wires Type Contact plating PA- J I SX LX BX SB SN LB LN V1 03 0 3 10 HK MK FK UK -E Description PA Series cable with connector cores AC (wire colors: brown, white, blue, black) (wire colors: brown, white, blue, black) - straight (male) - angle (male) - straight (male) - angle (male) Panel mounting 0.3m 0.m m 3m m 10m 6.0mm dia. oil-resistant vinyl cabtyre cable 6.1mm dia. oil-resistant, flexible, UL6, flame-resistant flexible vinyl cabtyre cable 6.1mm dia. oil-resistant, flexible, fluorine resin flame-resistant cabtyre cable 6.1mm dia. oil-resistant, flexible, UL6, flame-resistant flexible vinyl cabtyre cable EN-compliant model (TÜV approved model) Note: Some of the items in the above table cannot be combined. Be sure to check the coding table below to verify that a particular catalog listing is possible. ORDER GUIDE PA-HK-E Series (mm ) Standards Oil-resistant vinyl cabtyre cable - straight (male) - angle (male) - angle (male) - straight (male) 6.0 dia. 0. (0/0.08) 0.3 0. 3 10 10 PA-IBX03HK-E PA-IBX0HK-E PA-ISXHK-E PA-ISX3HK-E PA-ISXHK-E PA-ISX10HK-E PA-ILXHK-E PA-ILXHK-E PA-ISBHK-E PA-ISBHK-E PA-ISB10HK-E PA-ILNHK-E PA-ILNHK-E PA-ISNHK-E PA-ISNHK-E PA-ILBHK-E PA-ILBHK-E EN (TÜV Certification)

PA-MK-E Series (mm ) Standards Oil-resistant, flexible, UL6, vinyl cabtyre cable - straight (male) - angle (male) - angle (male) - straight (male) 6.1 dia. 0. (108/0.08) EN (TÜV Certification) PA-UK Series (mm ) Standards Oil-resistant, flexible, UL6, vinyl cabtyre cable - straight (male) - angle (male) - angle (male) - straight (male) 6.1 dia. 0. (108/0.08) cul 3

PA-FK-E Series (mm ) Standards Oil-resistant, flexible, fluorine resin flame-resistant cabtyre cable - straight (male) 6.1 dia. 0. (100/0.08) EN (TÜV Certification) Cables with male connectors (mm ) Terminal Oil-resistant vinyl cabtyre cable 6.0 dia. 0. (0/0.08) ( dia. terminal) Panel-mounted connector (mm ) AC AWG0 0.mm 0. APPLICATION EXAMPLES Lower maintenance costs due to faster replacement of switches Old way of wiring Existing sensor Wiring with the PA Quick-connection sensor (when connector-type limit switch is used) Wiring and staking operation PA connector Easy screw-in connection The PA simplifies wiring operations

The connector allows fast connection of the PLC to the sensor Programmable controller Maintenance of sensors and cables is simplified. Wiring can be completed in a much shorter time, and without errors. CONNECTOR SPECIFICATIONS*1 Item Operating voltage and current Insulation resistance Dielectric strength Initial contact resistance Mating/unmating force Mating cycles Connector nut torque Cable pullout strength Vibration resistance Shock resistance Protective structure Operating temperature Storage temperature Operating humidity Material Specifications AC type: Vac/dc ma min., 0Vac 3A, 1Vdc 3A max. type: Vac/dc ma min., 1Vac/dc 3A max. 100MΩmin. (by 00Vdc megger) 1,00Vdc for 1 minute (across contacts, and between contacts and connector housing) 0mΩmax. (excluding cable conductor-intrinsic resistance; at 3A with male-female contact combination) 0. to.0n (per contact) 0 times 0.8N m min.* 100N min. 10 to Hz, 1.mm peak-to-peak amplitude, hrs each in X, Y, and Z directions 300m/s, 3 times each in X, Y and Z directions IP67 (IP6 for panel-mounted type) 10 to +70 C 0 to +80 C 9% RH max. Contacts: gold-plated brass Contact holder: glass-lined polyester resin Housing: polyester elastomer (panel-mounted type: aluminum) Coupling: Orange brass (for AC), Ni-plated brass (for ) O-ring: NBR *1. Specifications assume Yamatake male/female connectors. *. The recommended tightening torque is 0. to 0.6N m. If fastened poorly, the IP67 protection may be lost, or the connector may come loose. CABLE SPECIFICATIONS Item PA-J PA-I HK PA-J PA-I MK PA-J PA-I FK PA-JV1K PA-I V1K 6.0mm 6.1mm 6.1mm Type of cable Oil-resistant cabtyre cable Flexible oil-resistant cabtyre cable Flexible oil-resistant andflame-resistant fluorine rubber cabtyre cable Heat resistant vinyl cable Sheath color 0.mm (0/0.18) Gray 0.mm (108/0.08) 0.mm (100/0.08) Gray Gray AWG0(0.mm )

CONNECTOR SHAPES Male Male Male Male Male Panel-mounted connector : AC, (J type), (I type) Lead colors: brown, white, blue, black PA- Gold-plated contacts Panel-mounted connector J: AC I: V1 K Appearance V1 AC 0.m PA-JV1K PA-IV1K Contact arrangement and lead colors for male/female connectors Male side side For ac For dc For ac For dc Contact No. 1 3 Lead colors Brown White Blue Black 6

EXTERNAL DIMENSIONS OF CONNECTORS ( cables are shown) (unit: mm) 1 dia. 1 dia. 1 dia. M1 1 dia. Angle (male) Panel-mounted connector, catalog listing PA- V1K A: type 18 dia. 0 dia. 13.6 dia. O-ring: 16 dia. x 1. dia. Lead wires: heat-resistant vinyl-insulated wire (UL style 1007), AWG0 (0.0mm), insulation external dia..mm max. Brown. White Blue Black Panel cutout dimensions 1.3 dia. Panel thickness : 1 to mm Recommended mounting centers: 6mm (suitable for socket wrench) 1 7

DIMENSIONS WHEN CONNECTED TO CONNECTOR-TYPE SENSOR (unit: mm) The dimensions below apply when the connector is attached. Add space for insertion/disconnection (approx. 1mm) during actual fitting. Connector-type proximity sensor with angle-type PA Connection to connector-type proximity sensor (FL7M) For attachment to an angle PA, calculate the total length as follows: Total length = A + 0mm Connector-type limit switch Connection to angle-type PA Connector-type limit switch with straight PA Note: When a connector-type sensor and angle-type PA are connected, the direction in which the PA cable exits may differ. Pay attention to this direction. PRECAUTIONS FOR USE Tightening the connector nut/lock ring Take special care if the mating part is made of resin, since the threads can easily be damaged when the connector is first tightened. When assembling the connector, align the center of the cores, push in as far as possible, and tighten. Tighten firmly by hand. The recommended tightening torque is 0. to 0.6N m. The use of a tightening tool may damage the connector. When securing the lock ring of a PA- V1K, close firmly (0. to 0.6 N m) by hand, or using the dedicated tool (PA-P1). If the connector is not tightened firmly, IP67 protection may be lost, or the connector may come loose. Inserting and removing connectors Before inserting or removing connectors, be sure to turn the power OFF. When removing connectors, do not pull by the cable. Hold the connector by its body when removing. Cautions when bending cables The minimum bend radius of the cable is 80mm. Make allowance for bends in the cable. Protective structure IP67 does not imply complete waterproofing. Do not use where constantly exposed to water. Avoid use where external force (or weight) is applied continuously on the connecting section of the connector. The body is molded resin. Do not step on the body or place heavy objects on it. Inserting and removing connectors The direction of the angle plug is restricted by the groove in the opposing plug. When using LX, NX, SX, LB, or LN series connectors, check the position of the groove in the opposing plug. Cautions during replacement When removing connectors to replace the sensor or cable, thoroughly wipe the connector and surrounding area to remove any water. After removing the connector, prevent it from being immersed in chemicals or powder, or being dropped. If the connector is accidentally immersed in liquid, allow it to dry completely before connecting again. If the connector is dropped in powder, completely wipe off any powder before connecting again. Failure to observe the above may result in short circuits or poor connections. 1 8