Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor malfunction Simultaneous mechanical assembly and electrical wiring Perfect for flexible production lines Usable even in harsh environments exposed to cutting oil (IP67) PA COMBINATIONS Sensor side Wiring side (PA side) Connector type sensor Cable with female connectors Limit switch Proximity sensor Sensors with preleaded connector Cables with tandem connectors General sensors and actuators Cables with male connectors Standard basic switch Solenoid valve Pressure switch, flow switch, motor, etc. Connectors for panel mounting Mounting direction Panel 1
SELECTION GUIDE Example:PA-JSXHK-E PA- J SX HK - E Basic model number of wires Type Contact plating PA- J I SX LX BX SB SN LB LN V1 03 0 3 10 HK MK FK UK -E Description PA Series cable with connector cores AC (wire colors: brown, white, blue, black) (wire colors: brown, white, blue, black) - straight (male) - angle (male) - straight (male) - angle (male) Panel mounting 0.3m 0.m m 3m m 10m 6.0mm dia. oil-resistant vinyl cabtyre cable 6.1mm dia. oil-resistant, flexible, UL6, flame-resistant flexible vinyl cabtyre cable 6.1mm dia. oil-resistant, flexible, fluorine resin flame-resistant cabtyre cable 6.1mm dia. oil-resistant, flexible, UL6, flame-resistant flexible vinyl cabtyre cable EN-compliant model (TÜV approved model) Note: Some of the items in the above table cannot be combined. Be sure to check the coding table below to verify that a particular catalog listing is possible. ORDER GUIDE PA-HK-E Series (mm ) Standards Oil-resistant vinyl cabtyre cable - straight (male) - angle (male) - angle (male) - straight (male) 6.0 dia. 0. (0/0.08) 0.3 0. 3 10 10 PA-IBX03HK-E PA-IBX0HK-E PA-ISXHK-E PA-ISX3HK-E PA-ISXHK-E PA-ISX10HK-E PA-ILXHK-E PA-ILXHK-E PA-ISBHK-E PA-ISBHK-E PA-ISB10HK-E PA-ILNHK-E PA-ILNHK-E PA-ISNHK-E PA-ISNHK-E PA-ILBHK-E PA-ILBHK-E EN (TÜV Certification)
PA-MK-E Series (mm ) Standards Oil-resistant, flexible, UL6, vinyl cabtyre cable - straight (male) - angle (male) - angle (male) - straight (male) 6.1 dia. 0. (108/0.08) EN (TÜV Certification) PA-UK Series (mm ) Standards Oil-resistant, flexible, UL6, vinyl cabtyre cable - straight (male) - angle (male) - angle (male) - straight (male) 6.1 dia. 0. (108/0.08) cul 3
PA-FK-E Series (mm ) Standards Oil-resistant, flexible, fluorine resin flame-resistant cabtyre cable - straight (male) 6.1 dia. 0. (100/0.08) EN (TÜV Certification) Cables with male connectors (mm ) Terminal Oil-resistant vinyl cabtyre cable 6.0 dia. 0. (0/0.08) ( dia. terminal) Panel-mounted connector (mm ) AC AWG0 0.mm 0. APPLICATION EXAMPLES Lower maintenance costs due to faster replacement of switches Old way of wiring Existing sensor Wiring with the PA Quick-connection sensor (when connector-type limit switch is used) Wiring and staking operation PA connector Easy screw-in connection The PA simplifies wiring operations
The connector allows fast connection of the PLC to the sensor Programmable controller Maintenance of sensors and cables is simplified. Wiring can be completed in a much shorter time, and without errors. CONNECTOR SPECIFICATIONS*1 Item Operating voltage and current Insulation resistance Dielectric strength Initial contact resistance Mating/unmating force Mating cycles Connector nut torque Cable pullout strength Vibration resistance Shock resistance Protective structure Operating temperature Storage temperature Operating humidity Material Specifications AC type: Vac/dc ma min., 0Vac 3A, 1Vdc 3A max. type: Vac/dc ma min., 1Vac/dc 3A max. 100MΩmin. (by 00Vdc megger) 1,00Vdc for 1 minute (across contacts, and between contacts and connector housing) 0mΩmax. (excluding cable conductor-intrinsic resistance; at 3A with male-female contact combination) 0. to.0n (per contact) 0 times 0.8N m min.* 100N min. 10 to Hz, 1.mm peak-to-peak amplitude, hrs each in X, Y, and Z directions 300m/s, 3 times each in X, Y and Z directions IP67 (IP6 for panel-mounted type) 10 to +70 C 0 to +80 C 9% RH max. Contacts: gold-plated brass Contact holder: glass-lined polyester resin Housing: polyester elastomer (panel-mounted type: aluminum) Coupling: Orange brass (for AC), Ni-plated brass (for ) O-ring: NBR *1. Specifications assume Yamatake male/female connectors. *. The recommended tightening torque is 0. to 0.6N m. If fastened poorly, the IP67 protection may be lost, or the connector may come loose. CABLE SPECIFICATIONS Item PA-J PA-I HK PA-J PA-I MK PA-J PA-I FK PA-JV1K PA-I V1K 6.0mm 6.1mm 6.1mm Type of cable Oil-resistant cabtyre cable Flexible oil-resistant cabtyre cable Flexible oil-resistant andflame-resistant fluorine rubber cabtyre cable Heat resistant vinyl cable Sheath color 0.mm (0/0.18) Gray 0.mm (108/0.08) 0.mm (100/0.08) Gray Gray AWG0(0.mm )
CONNECTOR SHAPES Male Male Male Male Male Panel-mounted connector : AC, (J type), (I type) Lead colors: brown, white, blue, black PA- Gold-plated contacts Panel-mounted connector J: AC I: V1 K Appearance V1 AC 0.m PA-JV1K PA-IV1K Contact arrangement and lead colors for male/female connectors Male side side For ac For dc For ac For dc Contact No. 1 3 Lead colors Brown White Blue Black 6
EXTERNAL DIMENSIONS OF CONNECTORS ( cables are shown) (unit: mm) 1 dia. 1 dia. 1 dia. M1 1 dia. Angle (male) Panel-mounted connector, catalog listing PA- V1K A: type 18 dia. 0 dia. 13.6 dia. O-ring: 16 dia. x 1. dia. Lead wires: heat-resistant vinyl-insulated wire (UL style 1007), AWG0 (0.0mm), insulation external dia..mm max. Brown. White Blue Black Panel cutout dimensions 1.3 dia. Panel thickness : 1 to mm Recommended mounting centers: 6mm (suitable for socket wrench) 1 7
DIMENSIONS WHEN CONNECTED TO CONNECTOR-TYPE SENSOR (unit: mm) The dimensions below apply when the connector is attached. Add space for insertion/disconnection (approx. 1mm) during actual fitting. Connector-type proximity sensor with angle-type PA Connection to connector-type proximity sensor (FL7M) For attachment to an angle PA, calculate the total length as follows: Total length = A + 0mm Connector-type limit switch Connection to angle-type PA Connector-type limit switch with straight PA Note: When a connector-type sensor and angle-type PA are connected, the direction in which the PA cable exits may differ. Pay attention to this direction. PRECAUTIONS FOR USE Tightening the connector nut/lock ring Take special care if the mating part is made of resin, since the threads can easily be damaged when the connector is first tightened. When assembling the connector, align the center of the cores, push in as far as possible, and tighten. Tighten firmly by hand. The recommended tightening torque is 0. to 0.6N m. The use of a tightening tool may damage the connector. When securing the lock ring of a PA- V1K, close firmly (0. to 0.6 N m) by hand, or using the dedicated tool (PA-P1). If the connector is not tightened firmly, IP67 protection may be lost, or the connector may come loose. Inserting and removing connectors Before inserting or removing connectors, be sure to turn the power OFF. When removing connectors, do not pull by the cable. Hold the connector by its body when removing. Cautions when bending cables The minimum bend radius of the cable is 80mm. Make allowance for bends in the cable. Protective structure IP67 does not imply complete waterproofing. Do not use where constantly exposed to water. Avoid use where external force (or weight) is applied continuously on the connecting section of the connector. The body is molded resin. Do not step on the body or place heavy objects on it. Inserting and removing connectors The direction of the angle plug is restricted by the groove in the opposing plug. When using LX, NX, SX, LB, or LN series connectors, check the position of the groove in the opposing plug. Cautions during replacement When removing connectors to replace the sensor or cable, thoroughly wipe the connector and surrounding area to remove any water. After removing the connector, prevent it from being immersed in chemicals or powder, or being dropped. If the connector is accidentally immersed in liquid, allow it to dry completely before connecting again. If the connector is dropped in powder, completely wipe off any powder before connecting again. Failure to observe the above may result in short circuits or poor connections. 1 8