INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK



Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

Digital Keypad Use s Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

P10 - Standalone Access Controller and Reader

User Manual. Before installation and use, please read the user manual carefully.

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

PAC1 Door Access Controller

VARIO PROX CARD READER INSTALLATION MANUAL

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

GSM HOME SECURITY SYSTEM

HyperAccess Access Control System

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

PROXIMITY CARD READERS C-10, C-20, C60, C70

How To Control A Car Alarm On A Car With A Remote Control System

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

INSTALLATION GUIDE. FCC ID NOTICE

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

How To Program An Autodialer

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

Business/Home GSM Alarm System. Installation and User Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

EQUIPMENT SPECIFICATIONS

e-ask electronic Access Security Keyless-entry

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

How to read this guide

SMS GSM Alarm Messenger

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

GV-AS Controller. Installation Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

ACCESS CONTROL SYSTEM

Transponder reader CÉLIANE TECHNICAL GUIDE

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

GV-AS/EV Controller. User s Manual

NC-12 Modbus Application

9452/9453 Installation and User Guide

Inductive Proximity Sensors

Intelligent GSM Auto-Dial Alarm System

USER MANUAL V5.0 ST100

Add Door Phones to Your Phone System

Using your LED Plus keypad

Secure Keypads for access control

Keypad Programming Instructions for the Profile Series LK and v.g1.5 Locks

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Installation manual. Version

User s Information Guide R1A

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Automatic Telephone Dialer TD-101(W)

Multifunction devices

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

User's Guide. Integrating Sound Level Datalogger. Model Introduction

500r+ Installation and User Guide

Keypad Programming Instructions for the Profile Series LK and v.g1 Locks

Solution 862 Operators Manual. Issue 1.00

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

GSMPBX version 1.3 Datasheet

CONCIERGE SWITCHBOARD

Auto Dialer. Manual E-921APQ E-921GPQ

Trilogy PDK3000 Series Programming Instructions

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Car Alarm Tracker Manual

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

AUTODIALLER / QUICKDIALLER - SA132

DGM1D Controller + Contact less Smartcard Reader

AR-721U/721K/661U User s Guide

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

WD-AMX Water Detection Controllers

Temperature & Humidity SMS Alert Controller

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GV- RK1352 Card Reader

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

MODEL DK-26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

WITURA CORPORATION SDN BHD

Temperature & Humidity SMS Alert Controller

STATUS POWER MONITOR ALARM SOS DISARM

REGTRONIC OPERATING INSTRUCTIONS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

INSTALLATION MANUAL XM3 Reader

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

MOBILE CALL GSM Alarm System User s Manual

TS510 & TS500. Installation & User Guide. Compatible Equipment

SECTION DETECTION AND ALARM

Manual for Fire Suppression & Methane Detection System

Advantium 2 Plus Alarm

T7560A,B,C Digital Wall Module

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Transcription:

Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK The E4KP EntryCheck is a fully self-contained proximity access control reader. It is keypad programmable and does not require software or a PC connection. Features HID compatible Proximity Reader Up to 3" read range with ProxCard II Weather resistant reader enclosure Memory capacity stores up to 650 user cards Cost-effective solution for access control and personnel management Access mode selectable 1. Proximity card only 2. Proximity card + PIN Master code for programming functions Main password function Security password function Forced entry alarm Door prop alarm Duress output User card can be registered/deleted in single or batch mode (with consecutive numbers) Reader Lockout activated when the wrong card is presented more than five times Lock and alarm output relays programmable 1-99 seconds or on-off latching Separate remotely located relay module for for higher security Optional Cards & Key Fobs Part# HID1326-10 (10) Prox Cards, HID ProxCard II Part# HID1346-10 (10) Prox Key Fobs, HID ProxKey II HID ProxCard II & ProxKey II are registered trademarks of HID Corporation Scan Me for Datasheet Pricesheet Install Instructions Use QR Code Phone App P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 1

FACTORY DEFAULTS System Setup Password... 111111 (6 digits) Door Open Password...... 1234 (4 digits) Door Open Mode...Read card Reading Card Data Format..Low weight 24Bits Patrol Password....1234567 (7 digits) Duress Password.. Door open password or PIN + 9 (5 digits) Shunt Function....Disabled Anti-Duress Function.....Disabled Patrol function.disabled Force Entry Alarm...... Disabled Door Prop Alarm Detection Time.......0 SEC (00 = Disabled) Door Prop Alarm.....Disabled Password Error over 5 times (keypad lockout for 1 min) OR PIN Error over 5 times (deletes the cardholder).....disabled Patrol Relay Active Time... 1 SEC (fixed) Strike Relay Active Time.. 5 SEC (00 = LATCH mode) Alarm Relay Active Time.....10 SEC (00 = non-stop alarm) Anti-Duress/Shunt Active Time....1 SEC Door Sensor Configuration Detection.....Normally Open QUICKSTART PROGRAMMING INSTRUCTIONS Before enrolling any cards, the default Door Open Password (1234 + #) may be used to activate the Strike Relay. Once a card is enrolled, the Door Open Password will no longer function. The following commands will program a specified number of sequential HID cards, and will set the strike relay time to 5 seconds. You will need the first card in the sequence. This is the card with the lowest card number (see below) Command Press 111111 + # Press 5 + # Present the first card in the sequence Enter the total number of cards + # Press # twice. LED Indicator {Alternating Red & Green LED} {Fast alternating Red & Green LED} {Flashing Red} {Fast alternating Red & Green LED} {Solid Red LED Normal Standby Mode} 5-DIGIT CARD NUMBER XXXXX XXXXXXXX-1 Present any of the cards to the reader. {Solid Green LED Strike Relay Active} PROXIMITY HID BASIC OPERATION The E4KP has two programmable entry modes: Mode 1 (Default) Card Only Mode 2 Card (or Enter Card Number) & PIN In Normal Standby Mode, the LED on the E4KP will be Solid Red. When the Strike Relay is active, the LED will be Solid Green. To Open the Door using an HID card or fob (in Mode 1), Present a valid card or fob within a couple of inches of the reader {Solid Green LED} To Open the Door using an HID card or fob (in Mode 2), Present a valid card or fob within a couple of inches of the reader {Slow Flashing Red LED} Enter the 4-digit PIN + # {Solid Green LED} P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 2

BASIC PROGRAMMING Entering Programming Mode Before ANY cards have been enrolled, Enter the System Setup Password + # {Alternating Red & Green LED} NOTE: Default System Setup Password is 111111 After a card or card number has been enrolled, (First card programmed is your programming card) Enter the System Setup Password + # {Fast flashing Red} Present first card programmed (programming card OR (Enter programming card number + #) {Alternating Red & Green LED} Exiting Programming Mode Press # until the E4KP displays a steady Red LED. (Normal Standby Mode) NOTE: The E4KP will automatically exit Programming Mode after 10 Seconds of inactivity Set Strike (Main) Relay Time (Default = 5 Sec) Press 1 + [00-99 seconds] + # {Alternating Red & Green LED} NOTE: 00 = Latching Mode Press # to exit programming. {Solid Red LED} Set Entry Mode (Default is Card OR Card Number) Choose the mode of entry you require & enter the adjacent command: {Alternating Red & Green LED} Mode 1 Card Only, Press + 1 + # Mode 2 Card (or Enter Card Number) & PIN, Press + 2 + # * * CARD OR KEY FOB ENROLLMENT IMPORTANT: It is highly recommended that an administrator keep a log of the Card/Key Fob numbers, and who they are assigned to. The 5-digit card/fob number can typically be found on one side of the HID Card or Fob (See Pg. 2). If a card ever needs to be deleted, you will need the card or the card number. Adding a Single Card OR Card Number Press 4 + # {Fast, alternating Red & Green LED} Present Card OR Enter the Card Number (0 65535) + # {Flashing Red LED} Key in a 4-digit PIN + # (If you do not want to enter a PIN, just Press #) {Fast alternating Red & Green LED} NOTE: If you choose not to enter a PIN number, the PIN will be set to 0000. Present the next card to be entered or Press # to exit card enrollment {Alternating Red & Green LED} Press # again to exit Programming {Solid Red LED} Adding a Batch of Sequential Cards Press 5 + # {Fast, alternating Red & Green LED} Present the first sequential card {Flashing Red LED} Enter the total number of cards + # {Fast, alternating Red & Green LED} Present the first card of another sequence or Press # to exit card enrollment NOTE: The PIN number for all cards enrolled in batch mode is 0000. Press # again to exit Programming {Solid Red LED} {Alternating Red & Green LED} Deleting a Single Card OR Card Number Press 6 + # {Fast, alternating Red & Green LED} Present Card OR (Enter the Card Number + #) {Fast, alternating Red & Green LED} Present/Enter another Card to delete or Press # to exit card deletion {Alternating Red & Green LED} Press # again to exit Programming {Solid Red LED} P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 3

PROGRAMMING OPTIONS Set Alarm Relay Time (Default = 5 sec) Press 2 + [00-99 seconds] + # {Alternating Red & Green LED} NOTE: The Alarm Relay is used for Forced Door & Door Prop alarms. 00 = Non-stop alarm Reset by using a valid card. Enable Forced Door Alarm Relay (Default = Force Door Disabled) To enable, Press 841 + # {Alternating Red & Green LED} To disable, Press 840 + # {Alternating Red & Green LED} NOTE: A Door Position Sensor must be installed. Enable & Set Door Prop Time (Default = Door Prop Disabled) To enable, Press 881 + # {Alternating Red & Green LED} Press 3 + [01-99 seconds] + # (sets Door Prop Time; Default = 00) {Alternating Red & Green LED} To disable, Press 880 + # {Alternating Red & Green LED} Press 300 + # {Alternating Red & Green LED} NOTE: A Door Position Sensor must be installed. Relay will remain activated until the door closes OR the Alarm Relay time expires, whichever occurs first. Set Shunt Relay Time (Default = Shunt Disabled) With the Shunt Relay Enabled, the Auxiliary (K3) Relay will activate simultaneously with the Strike Relay: To enable, Press 812 + # {Alternating Red & Green LED} Press 0 + [01-99 seconds] + # (sets Shunt Relay Time; Default = 01) {Alternating Red & Green LED} To disable, Press 810 + # {Alternating Red & Green LED} NOTE: DIP SWITCH 1 on the E5RM control module, must be ON. Shunt cannot be used if Anti-Duress is enabled. Set Anti-Duress Relay Time (Default = Anti-Duress Disabled) With the Anti-Duress Relay Enabled, the Auxiliary (K3) Relay will activate when the Door Open Password (See Factory Defaults) OR a User s PIN (Entry Mode 2 ONLY), is entered, followed by a 9 : To enable, Press 811 + # {Alternating Red & Green LED} Press 0 + [01-99 seconds] + # (sets Duress Relay Time; Default = 01) {Alternating Red & Green LED} To disable, Press 810 + # {Alternating Red & Green LED} NOTE: DIP SWITCH 1 on the E5RM control module, must be ON. Anti-Duress cannot be used if Shunt is enabled. Enable Reader Lockout (Default = Disabled) Enabling this function will do the following: 1. If an invalid card or card number is used (5) times in a row, this option will Lockout the keypad for approx. 1 minute. 2. In Entry Mode 2, if an invalid PIN number is entered over (5) times, the card will automatically be deleted. To enable, Press 851 + # {Alternating Red & Green LED} To disable, Press 850 + # {Alternating Red & Green LED} Set Door Status Sensor Configuration (Default = Normally Open) For Normally Closed, Press 861 + # {Alternating Red & Green LED} For Normally Open, Press 860 + # {Alternating Red & Green LED} P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 4

PROGRAMMING OPTIONS (CONTINUED) Change a User s PIN (Entry Mode 2 Only) Press + 2 + # + Present Card OR (Enter Card Number + #) {Flashing Red LED} Enter old * 4-digit PIN + # {Flashing Red LED} Enter new 4-digit PIN + # {Solid Red LED} NOTE: It is NOT required to enter Programming Mode to change a PIN. Clear Memory / Reset to Default Settings Press 99999999 + # {Green LED will flash rapidly, then Alternating Red & Green LED} Change Default Passwords To change System Setup Password (Default = 111111), Press + New 6-digit Password + # {Alternating Red & Green LED} To change Door Open Password (Default = 1234), Press + New 4-digit Password + # {Alternating Red & Green LED} To change * Patrol Password (Default = 1234567) Press + New 7-digit Password + # {Alternating Red & Green LED} * Enable Patrol Function (Default = Patrol Function Disabled) With this feature enabled, entering the Patrol Password will send a 1 second pulse on the Auxiliary (K3) Relay: Press 831 + # (enables Patrol Function, use 830 + #) {Alternating Red & Green LED} NOTE: DIP SWITCH 3 on the E5RM control module, must be ON. SPECIFICATIONS Keypad Model E4KP Operating Voltage: 10V 15V DC Consumption: 120mA Max @ 12VDC Frequency: 125KHz Read Range: Up to 3" (Card, In noise-free environment) Keyboard: 12 Keys (0~9,, #), Membrane Keys Indicator: Dual Color LED *(Green/Red) Memory (User) Capacity: 670 Cardholders Card Format: HID Compatible 125KHz Cable Length: 1 Ft. Dimensions: 3" W x 4-3/8" H x 0.9" D (75 x 112 x 23 mm) Weight: 8.5 ounces Operating Temperature: 32 o F 122 o F (0 o C 50 o C) Humidity: 30% ~ 95% (Non-condensing) KEYPAD MODEL E4KP Controller Relay Module Model E5RM Operating Voltage: 10V 15V DC Consumption: 300mA Max @ 12VDC (with E4KP) Relay: Strike: 5A N.O. / 3A N.C. @ 30VDC Alarm/Aux.: 1A @ 30VDC Inputs: Exit Button (N.O.) Door Status Sensor (N.O. or N.C) Dimensions: 1-3/4" W x 2-5/8" L x 0.9" D (46 x 66 x 21 mm) Weight: 2.5 ounces Operating Temperature: 32 o F 122 o F (0 o C 50 o C) Humidity: 30% ~ 95% (Non-condensing) P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 5 +12V GND CLOCK DATA ACCESS CONTROLLER K3 FUNCTION SETTING FUNCTION DURESS/SHUNT GUARD PATROL ON 1 2 3 1 2 3 ON ON MODEL : E5RM S/N : 12345678 INPUT DC12V EXIT BUTTON DOOR SENSOR ON STRIKE ALARM CONTROLLER RELAY MODULE MODEL E5RM K3 + -

TYPICAL WIRING DIAGRAM NOTE: Dual voltage power supplies should be switched to 12VDC prior to hook-up USE WITH 12vdc LOCKS 600 SERIES POWER SUPPLY POWER SUPPLY 12VDC OR USE WITH 24vdc LOCKS 600 SERIES POWER SUPPLY WITH 12VR MODULE 12VR MODULE POWER SUPPLY 24VDC * KEYPAD POWER IS 12V DC ONLY. CONNECTING A HIGHER VOLTAGE OR AC WILL DAMAGE THE UNIT AND VOID THE WARRANTY E4KP KEYPAD NOT USED Installation Notes: 300 ft MAX J3 12V +12V GND CLOCK DATA Lock Keypad 12 VDC 12V ALARM OUTPUT AUX. OUTPUT (DIP SW SELECTABLE) E5RM CONTROLLER RELAY MODULE + - Request -to-exit Door Status C LOCK NC OUTPUT NO C NC NO C NC NO 24V Lock Keypad J2 J1 Lock 12V or 24VDC Keypad 12VDC ONLY * REX BUTTON N.O. DRY CONTACT (OPTIONAL) MOV + - FAIL SECURE LOCK DOOR STATUS SWITCH N.O. OR N.C. (OPTIONAL) MOV + - FAIL SAFE LOCK 1. Max distance between the E4KP Keypad & E5RM is 300ft. 2. Alarm Output Relay will be used for Door Prop or Forced Door Alarm. 3. Auxiliary Output Relay will be used for Shunt/Anti-Duress feature and/or Patrol Function. 4. J1, J2, & J3 Connectors are included with the E5RM. Supply, Exit Button, & Door Switch are sold separately. 5. For DC voltage electric strikes and electric bolt locks, install a Metal Oxide Varistor (MOV) as close to the coil as possible to prevent kickback voltage from damaging the relay module. Consult with the Lock Manufacturer to see if a voltage suppression device is necessary. P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 6