FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com



Similar documents
FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

SPP Pumps Inc. Atlanta

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Para la protecció n de la vida y las propiedades, las Bombas de Incendio AC ofrece paquetizados que satisfacen cada necesidad.

Fire Pump Plan Review March 2010

TECHNICAL INFORMATION Bulletin

VERTICAL TURBINE AND PROPELLER PUMPS

World-Class Fire Suppression Pumping Solutions

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

SJT / SJM / SJP Large Vertical Pumps

FIRE FIGHTING PACKAGES

Axial and Mixed Flow Pumps for Large Volume Pumping

CHAPTER. Fire Pumps FIRE PUMP OVERVIEW. Fire Pump Unit Defined. Fire Pump Unit Responsibility

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

! WARNING. Before using product, read and understand instructions.

Vertical Pumps for the Oil & Gas Industry

Fire Protection Pumps

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Dry Pit Solids Handling Pumps

Diesel Engine Driven Generators Page 1 of 6

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

TECHNICAL INFORMATION Bulletin

Pumps SELECTION OF A PUMP

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SECTION DIESEL-DRIVEN, FIRE PUMPS

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

Pump and Valve Components and Maintenance

Model 763 AURORA. 750/760 Series APCO-PM CONSTANT PRESSURE BOOSTER SYSTEMS

Medical Air Systems: Scroll

Horizontal Jet Pumps 1/3-1-1/2 HP

Model 1210C Battery Powered Pump Shown. Description

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

Rotary Phase Converters

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

Design & Construction Standards, Revised January

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Model 413 AURORA. 410 Series SINGLE STAGE SPLIT CASE PUMPS

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Pump Maintenance - Repair

Annex-A TECHNICAL SPECIFICATION

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

TECHNICAL ADVISORY BULLETIN

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

MAC-120HE-01 Air-Cooled Chiller

BERMAD Fire Protection

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Element D Services Plumbing

NFPA31FuelOilPiping 1 Revised

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

PRESSURE REDUCING CONTROL VALVE

300 Series PA Pump and Cooler Assemblies

IMPORTANT SAFETY NOTICE

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

BERMAD Fire Protection

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Series 1510 Centrifugal Pumps Technical Bulletin. Bulletin B-207G Bell & Gossett

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

APPLICATIONS Water systems for municipal, multiple housing, commercial, in water fountains, irrigation, mine de-watering, and farm use.

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Single Phase Soft Starter

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

4" SUBMERSIBLE PUMPS

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

AURORA. 110A Series "APCO" ONE AND TWO STAGE TURBINE PUMPS

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

Morrison Bros. Co. General Product Specifications

MONITOR SECTION INDEX

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

KODAK VERSAMARK, INC.

Utility Distribution Systems

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

HORIZONTAL PUMPING SYSTEM

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

QL Series Vertical, Double-Suction, Twin-Volute Turbine Pumps

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

A. Section includes air conditioning units, controls and control panels.

SUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

Procurement, Inventory Management and Supply Chain solutions for the Petrochemicals sector

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

KIRLOSKAR FIRE FIGHTING PUMPS AND PACKAGES

Pressure Limiting Driver (PLD)

The conditions below apply to the curves shown on the following pages.

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

BOWIE PUMPS OPERATION - MAINTENANCE

Your safety and the safety of others are very important.

BLADDER SURGE CONTROL SYSTEM

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

world class fire pumps

Transcription:

FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com

FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case, vertical in-line, end suction and vertical turbine designs over a wide range of rated capacities and pressures pumps for every fire pump application. Split case, end suction and vertical turbine pumps have the option of being driven via either an electric motor or diesel engine. All pumps are furnished as a complete package with driver, controller, jockey pump and its controller, as well as standard fire pump system accessories. Fairbanks Nijhuis fire pumps are Underwriters Laboratories Listed and Factory Mutual Approved specifically for fire pump service, continually meeting the agencies stringent inspection, testing and record-keeping standards. Split case rated capacities range from 250 GPM through 5000 GPM, vertical in-line rated capacities range from 50 GPM through 1500 GPM, and vertical turbine fire pumps cover 250 GPM through 4500 GPM, all with a wide range of rated pressures. The Fairbanks Nijhuis sales family includes highly qualified distributors and representatives experienced in fire pump systems, who provide prompt and accurate quotations, submittals and acceptance testing as required. These fire protection professionals stand ready to address and meet your fire pump needs, and are backed by factory knowledge and experience. HORIZONTAL AND VERTICAL SPLIT CASE Pump Features: Bronze impeller Cast iron or ductile iron casings Clockwise or counterclockwise rotation (electric only) Casing wear rings Renewable shaft sleeves Grease lubricated long life bearings Packed stuffing box Horizontal Split Case Rated Performance Rated Capacity Rated Pressure 250 5000 GPM 40 506 PSI Vertical Split Case Rated Performance Rated Capacity Rated Pressure 250 2500 GPM 40 200 PSI 2

Pump Selection VERTICAL IN-LINE END SUCTION VERTICAL TURBINE Pump Features: Bronze impeller One-piece, in-line casing Clockwise rotation Casing wear ring Renewable shaft sleeve Integral vertical motor Packed stuffing box Pump Features: Stainless steel impeller Renewable shaft sleeve Ductile iron casing Carbon steel shaft Packed stuffing box Grease lubricated long life bearings NEMA-HI T-frame motor Diesel engine drive option Casing feet for easy back pullout Pump Features: Cast iron bowl (multi-stage) Stainless steel bowl shaft Carbon steel open lineshaft Steel column pipe Cast iron or fabricated steel discharge heads Brass suction strainer Packed stuffing box Vertical In-Line Rated Performance End Suction Rated Performance Vertical Turbine Rated Performance Rated Capacity Rated Pressure 50 1500 GPM 40 160 PSI Rated Capacity Rated Pressure 50 1500 GPM 40 225 PSI Rated Capacity Rated Pressure 250 4500 GPM 75 387 PSI www.fairbanksnijhuis.com 3

Typical Horizontal Split Case Fire Pump System 1. OS & Y Gate Valve with Tamper Switch 2. Compound Suction Gauge 3. Horizontal Split Case Fire Pump, Electric Motor Driven 4. Automatic Air Release Valve 5. Casing Relief Valve 6. Discharge Pressure Gauge 7. Low Suction Pressure Shutoff Valve 8. Fire Pump Controller 9. Check Valve 10. Jockey Pump Controller 11. Jockey Pump 12. Isolation Valves with Tamper Switches 13. Ball Drip Valve 14. Test Valve Manifold with Hose Valves, Caps and Chains 1 2 3 4 5 Pump: Horizontal split case, double-suction, UL Listed, FM Approved, mounted on a common base with and flexibly coupled to an electric motor. Pump sized for rated capacity and head. Also must be capable of producing 150% rated flow at not less than 65% rated head and not to exceed 140% rated head at a shutoff or no-flow condition. Controller: Electric motor controller starts the motor automatically on a loss of system pressure. System pressure is monitored via a sensing line from the system side of the check valve. Controller can also be manually started. The type of motor starting, and therefore the type of controller, varies depending upon the specifics of the application. Common types of controllers include across-the-line, primary resistor, part-winding, wye-delta, auto-transformer and soft start. Controllers are UL Listed and FM Approved specifically for fire pump service. Base: Fabricated steel design base capable of adequately supporting the weight of the pump and driver. After pump has been fully piped and accurately aligned with the motor, the base should be fully grouted into place. Electric Motor: UL Listed fire pump motor sized so as to not overload at any point on the pump hydraulic curve as per NFPA #20. Motors have a 1.15 service factor, wound for the correct voltage. Motor to be compatible with the type of controller (i.e., starting method). Coupling: Flexible type, sized to transmit the horsepower requirements of the pump. Coupling shall be furnished with an OSHA-design coupling guard. Standard Accessories: Accessories furnished with the fire pump system include suction and discharge gauges, casing relief valve and automatic air release valve. Other accessories commonly furnished as part of the fire pump package include hose valve manifold with hose valves, caps and chains, flowmeter, city bypass, low suction control valve, ball drip valve, eccentric suction reducer and concentric discharge increaser. Jockey Pump: Jockey pump keeps pressure in the system to prevent the main fire pump from operating to maintain system pressure. Jockey pumps are sized about 1% of flow to overcome small system leaks and typically sized for 10 PSI greater than the rated pressure of the main fire pump. Jockey pumps are not required to be UL Listed or FM Approved. Jockey Pump Controller: Starts the jockey pump across the line by sensing the system pressure via a sensing line from the system side of the check valve. This sensing line must be independent from the main fire pump controller sensing line. Controller is sized per the jockey pump motor horsepower and voltage. Jockey pump controllers are UL Listed specifically for this service. 4

8 Electric Motor Driven 10 14 7 11 6 12 13 9 www.fairbanksnijhuis.com Approved Controller Starting Methods Type Starting Characteristics Advantages Restraints Across the line Primary Resistance Reduced Voltage Part Winding Wye-Delta Open-Transition Wye-Delta Closed-Transition Auto Transformer Reduced Voltage w/50% tap w/ 65% tap w/80% tap Soft Start/Stop Connects motor directly to power source. Full voltage applied to motor when controller is actuated. When controller is actuated, a resistance is connected to each phase. Resistors are bypassed after a time delay and motor then runs at full voltage. Motor starts on one winding. After a time delay, second winding is connected in parallel to the line. On controller activation, motor windings wyeconnected for starting, After a time delay, automatically converts to delta connection for running, applying full voltage to motor windings. Most often used with transfer switch/emergency generator applications. Same sequence as Open Transition. Connected to resistors in each phase during transition from wye to delta. Starters supply reduced voltage starting at motor terminals through use of tapped, 3-phase autotransformer. A timing relay causes transfer of motor from reduced voltage start to line voltage operation without disconnecting motor from power source. Reduces inrush current to motor with adjustable ramp time. Stop sequence reduces possibility of surges occurring in the system. * Least expensive * Highest starting torque * Low maintenance * Standard motor used * Smooth starting * Low shock to motor * Standard motor used * Low relative cost * Low starting torque * Low maintenance * Moderate to low relative cost * Low motor stress * Low starting current * Moderate to high relative cost * Low motor stress * Low starting current * No line transients * Good for heavy starting loads * Highest starting torque * Standard motor used * Low starting current * Starting torque adjustable * Low inrush current * Adjustable ramp time * Reduces system surges * Standard motor used Starting Current (% Motor Full Load Starting Current) Starting Torque (% Locked Rotor Torque) Type Transition * High inrush current 600% 100% N/A * High power loss through resistors * Must dissipate heat * Low torque per ampere input * Medium relative cost * Not recommended for transfer switch applications * Not recommended for frequent starting * Low starting torque * Special motor required * Medium starting torque * Special motor required for 200V 208V * Power line transients * Can affect other equipment sharing same power source * Medium starting torque * Special motor may be required for 200V 208V * High relative cost * Large heavy cabinet * Legacy technology 300% 25% Closed 390% 42% Closed 200% 33% Open 200% 33% Open 150% 252% 384% * High relative cost Adjustable 50 500% 25% 42% 64% Varies, down to 30% Closed Closed 5

Horizontal Split Case Fire Pump System 2 1. Fuel Tank, Diesel Engine 2. Low Fuel Level Switch 3. Leak Detection Switch 4. OS & Y Gate Valve with Tamper Switch 5. Compound Suction Gauge 6. Automatic Air Release Valve 7. Diesel Engine 8. Horizontal Split Case Fire Pump 9. Discharge Pressure Gauge 10. Enclosed Waste Cone with Sight Glasses 11. Main Relief Valve 12. Fire Pump Controller 13. System Check Valve 14. Jockey Pump Controller 15. Jockey Pump 16. Isolation Valves with Tamper Switches 17. Ball Drip Valve 18. Test Valve Manifold with Hose Valves, Caps and Chains 3 1 4 5 Pump: Horizontal split case, double-suction, UL Listed, FM Approved, mounted on a common base with and flexibly coupled to a diesel engine. Pump sized for rated capacity and head. Also must be capable of producing 150% rated flow at not less than 65% rated head and not to exceed 140% rated head at a shutoff or no-flow condition. Diesel Engine: UL Listed, FM Approved diesel engine adequately sized so as to not overload at any point on the pump hydraulic curve. Consideration must be given and de-rates applied based on job site elevation and ambient temperature. Engines must be specifically designed for fire protection service. Coupling: Flexible type, sized to transmit the horsepower requirements of the pump. Coupling shall be furnished with an OSHA-design coupling guard. Controller: Diesel engine controller starts the engine automatically on a loss of system pressure. System pressure is monitored via a sensing line from the system side of the check valve. Controller can also be manually started. Controllers are UL Listed and FM Approved specifically for fire pump service. Base: Fabricated steel design base capable of adequately supporting the weight of the pump and driver. After pump has been fully piped and accurately aligned with the engine, the base should be fully grouted into place. Standard Pump Accessories: Accessories furnished with the fire pump system include suction and discharge gauges and automatic air release valve. Other accessories commonly furnished as part of the fire pump package include hose valve manifold with hose valves, caps and chains, flowmeter, city bypass, main relief valve and enclosed waste cone, ball drip valve, eccentric suction reducer and concentric discharge increaser. Standard Engine Accessories: Accessories furnished with the diesel engine include engine starting batteries, battery rack, battery cables, engine exhaust flexible connector and silencer. Jockey Pump: Jockey pump keeps pressure in the system to prevent the main fire pump from operating to maintain system pressure. Jockey pumps are sized about 1% of flow to overcome small system leaks and typically sized for 10 PSI greater than the rated pressure of the main fire pump. Jockey pumps are not required to be UL Listed or FM Approved. Jockey Pump Controller: Starts the jockey pump across the line by sensing the system pressure via a sensing line from the system side of the check valve. This sensing line must be independent of the main fire pump controller sensing line. Controller is sized per the jockey pump motor horsepower and voltage. Jockey pump controllers are UL Listed specifically for this service. 6

Diesel Engine Driven 11 12 14 18 6 7 10 15 8 9 16 17 13 PACKAGED FIRE PUMP SYSTEMS When the application calls for a completely packaged fire pump system, Fairbanks Nijhuis has the capability to meet these requirements. Systems include the pump, driver, controller, jockey pump and jockey pump controller all mounted on a common base. Controller is prewired to the driver, sensing lines are prepiped from the controllers to the system side of the check valve, and suction and discharge piping is piped to the edge of the common base. Isolation valves, check valve and test header piping (and/or flowmeter piping) can be supplied as required. For diesel engine driven units, the package would also include the mounting of the fuel tank, wiring of fuel alarms, piping of fuel lines to the engine, connection of batteries to the engine, all the latest NFPA20 and NEC requirements. Should your requirements specify the packaged fire pump system to include an enclosure, Fairbanks Nijhuis can provide the protective structure to house the system. Packaged systems can be designed for use with all fire pump designs and constructed to accomodate container shipments. www.fairbanksnijhuis.com 7

R R ISO 9001 QUALITY SYSTEM CERTIFIED C LISTED LISTED FAIRBANKS NIJHUIS PUMP 800 AIRPORT ROAD, 3601 FAIRBANKS AVENUE, PARALLELWEG 4 NORTH AURORA, ILLINOIS 60542 KANSAS CITY, KANSAS 66106 7102 DE WINTERSWIJK, THE NETHERLANDS www.fairbanksnijhuis.com www.fairbanksnijhuis.com www.fairbanksnijhuis.com Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. FMF-02-1043 05/30/13 2013 Pentair Ltd. All Rights Reserved.