Architectural and Engineering Specification for a Perimeter Intrusion Detection System. FiberPatrol-ZR



Similar documents
Architectural and Engineering Specification for a Perimeter Intrusion Detection and Pipeline Third-Party Interference (TPI) Detection System

Introducing TransitVUE Perimeter IDS, the most advanced perimeter intrusion detection system available today! Protecting Perimeters Around the World

CUT-IMMUNE MULTI-ZONE FIBER OPTIC PERIMETER INTRUSION DETECTION SYSTEM

Perimeter Security System

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

INTREPID Perimeter Intrusion Detection System

FIBER SECURITY. Optical Fiber Perimeter Intrusion Detection System

Microphonic Cable Fence Disturbance Sensor (multiplex version)

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

How to Solve the Most Persistent Problem in Perimeter Security Systems

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

A. Provide a complete and fully operation Access Control system fully integrated to the campus Lenel system.

Infinity 2020 Perimeter Intrusion Detection System

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TrueAlarm Fire Alarm Systems

Optical fiber intrusion detection fence sensor

7 MEGAPIXEL 180 DEGREE IP VIDEO CAMERA

INTRUSION ALARM SYSTEM

Provides one channel for Ethernet over existing

C. Conform to requirements of Americans with Disabilities Act (ADA).

Security & Surveillance Cabling Systems

Advanced Fencing and Security Technologies Ltd

DVI DA2 and DVI DA 4 User Guide

Cisco Redundant Power System 2300

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Cisco Unified IP Phone Power Injector

Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System

THE STRUCTURAL HEALTH MONITORING SYSTEM OF THE RION ANTIRION BRIDGE CHARILAOS TRIKOUPIS. Akis Panagis

HP UPS R1500 Generation 3

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

About the BitStorm 6051 POTS Splitter

The Premier Fence Mounted Perimeter Intruder Detection System

8-Port PoE Network Switch

PowerCommand iwatch 100

CalMod Design-Build Electrification Services

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Interceptor Optical Network Security System. Design Guide. Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Special Specification 6033 Computerized Transportation Management System

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Cisco 7816-I5 Media Convergence Server

Cisco MCS 7825-H3 Unified Communications Manager Appliance

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Office of Integrated Security Systems Longwood University Camera System Standards

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Georgia Tech Aerospace Server French building Server Room. Server Room Policy Handbook: Scope, Processes and Procedure

Design and Construction Criteria C. Utility Coordination

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Provides one channel for Ethernet over existing

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

WIRELESS INSTRUMENTATION TECHNOLOGY

Wireless Data Logger Monitoring Systems

Cisco IPS 4200 Series Sensors

the new wireless home alarm system

Intrusion Outdoor Protection Perimeter

Architectural/Engineering Specification for an. Industrial, Managed, Cyber Protected. Ethernet Switch TUNGSTEN

Cisco MCS 7816-I3 Unified Communications Manager Appliance

G-TAP A Series // Data Sheet

Prisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters

GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications

, User s Manual

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

Vindicator Security Solutions EXTEND YOUR SECURITY PERIMETER. Vindicator Radar Detection System

How To Create An Intelligent Infrastructure Solution

AXIS T81B22 DC 30W Midspan

Appendix A - Cost Estimate Spreadsheet

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Fiber Optic Distributed Temperature Sensor (B-DTS)

SECTION 22 LIGHTNING PROTECTION SYSTEM

DTW Works Master Specification Version 2006

INTREPID Buried Cable Perimeter Intrusion Detection System

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

SC100 Series Seismic Vibration Sensors. The Best Way to Protect High-Risk Commercial Assets

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

KVM - DVI, USB 2.0, Cat 5 Extender

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide

Transcription:

Architectural and Engineering Specification for a Perimeter Intrusion Detection System FiberPatrol-ZR Sept 3, 2014 Page 1 of 13 FLR1DA0315-001 Rev A

This document is intended to provide performance specifications and operational requirements for the FiberPatrol-ZR perimeter intrusion detection system. It is written in a generic format. These specifications may be copied verbatim to form a generic procurement specification. Senstar and the Senstar logo are registered trademarks of Senstar Corporation. FiberPatrol and Silver Network are trademarks of Senstar Corporation. The information in this document is subject to change without notice. Senstar reserves the right to make changes to product design or manufacturing methods, as engineering progresses, or as other circumstances warrant. Copyright 2014. Senstar Corporation. All rights reserved. Sept 3, 2014 Page 2 of 13 FLR1DA0315-001 Rev A

Part 1 General... 4 1.1 System Summary... 4 1.2 Submittals... 4 1.3 Qualifications... 4 1.4 Spares... 4 1.5 Warranty... 4 1.6 References... 5 Part 2 Products... 6 2.1 Fence-Mounted Perimeter Intrusion Detection System... 6 2.2 Manufacturers... 6 2.3 Regulatory Requirements... 6 2.4 Mechanical Requirements... 6 2.5 Environmental Requirements... 7 2.6 Reliability and Maintenance Requirements... 7 2.7 Electrical Requirements... 7 2.8 Detection Capabilities... 8 2.9 Cable cut response... 9 2.10 Installation and Configuration Capabilities... 10 2.11 Networking Capabilities... 10 2.12 Event Management... 11 2.13 Access Control... 12 Part 3 Execution... 13 3.1 Site Assessment... 13 3.2 System Installation... 13 3.3 System Calibration... 13 3.4 Training... 13 Sept 3, 2014 Page 3 of 13 FLR1DA0315-001 Rev A

PART 1 GENERAL 1.1 System Summary 1.2 Submittals The contractor shall install a zone-reporting, fence-mounted perimeter intrusion detection system (PIDS). The system shall detect and locate intruders that attempt to cut, climb, or lift the fence fabric. The system shall also be capable of protecting wall structures against climbing, scaling, or ladder-based intrusion attempts. The detection sensors shall consist of fiber optic cables. The cables shall connect to a signal processing module that detects and locates attempted intrusions by analyzing the changes in reflected energy that occur as a result of minute vibrations in the sensor cables. The system shall be capable of being integrated into the facility s Security Management System. 1.3 Qualifications 1.4 Spares 1.5 Warranty A. Contractor submittals to the facility owner shall include the following as a minimum: 1. Site conditions report as per article 3.1 2. Configuration and calibration settings for the system after installation and calibration are complete as per article 3.3 3. All manufacturer-supplied software required for the calibration and operation of the system. 4. Documentation providing system operation and maintenance procedures. A. The manufacturer of the system shall have a minimum of five (5) years experience in the last 10 years of the manufacture and successful implementation of similar systems. A. The contractor shall deliver to the facility owner spare system components. B. For each system component, spares consisting of least one unit or 10% of the number that comprise the system, whichever is greater, shall be provided. A. The product shall be under warranty for a minimum of two years from the date of purchase. B. The supplier shall make available replacement components, parts or assemblies for a minimum of 10 years from the date of purchase. Sept 3, 2014 Page 4 of 13 FLR1DA0315-001 Rev A

1.6 References A. Abbreviations and acronyms: The following acronyms and abbreviations are used in this document: 1. PIDS: Perimeter Intrusion Detection System 2. MTBF: Mean Time Between Failures 3. MTTR: Mean Time To Replace 4. OTDR: Optical Time-Domain Reflectometer 5. Pd: Probability of Detection B. Reference Standards: The following regulatory and industry standards are referenced in this document: 1. Federal Communications Commission: FCC CFR Part 15, Subpart B requirements for Class A devices. 2. Conformité Européenne (CE) Sept 3, 2014 Page 5 of 13 FLR1DA0315-001 Rev A

PART 2 PRODUCTS 2.1 Fence-Mounted Perimeter Intrusion Detection System A. The contractor shall supply a zone-reporting, fence-mounted perimeter intrusion detection system (PIDS). B. The fence-mounted PIDS shall detect and locate intruders attempting to breach the perimeter fence by cutting, climbing, or lifting the fence fabric. C. The system shall be capable of protecting wall structures against climbing, scaling, or ladder-based intrusion attempts. 2.2 Manufacturers A. The FiberPatrol-ZR system from Senstar Corporation (www.senstar.com) meets the requirements stated in this document. 2.3 Regulatory Requirements A. The system shall comply with the following regulations: 1. FCC 47 CFR Part 15, Subpart B requirements for Class A devices 2. CE 2.4 Mechanical Requirements A. Sensor cable: 1. The sensor cable shall have the option to be encased in an armor jacket, for use in areas that have a high potential of physical damage to the cable. 2. The sensor cable shall have a minimum bend radius no greater than 15 cm (6.0 inches). 3. The sensor cable shall be affixed to the facility s fence through the use of UVresistant plastic or metal cable ties. 4. The sensor cable shall not require a cable conduit to be installed along the fence perimeter to protect the cable. 5. The sensor cable shall be able to include additional, unused fibers for use by other equipment (such as for data or video communications). B. Sensor unit equipment: 1. The system shall not require any active devices or processor modules to be installed outdoors. 2. All active components shall be rack-mountable in an indoor, equipment room environment 3. The indoor system components shall be designed for standard 19-inch wide rack. Sept 3, 2014 Page 6 of 13 FLR1DA0315-001 Rev A

4. The system shall provide the option for a slide-out monitor and keyboard that enables local console access to the system. 5. The system shall include a fiber optic patch panel for interfacing the sensor cable to the processor and controller modules. 2.5 Environmental Requirements A. The sensor cables shall withstand operation in temperatures from 40 C to 70 C ( 40 F to 158 F) and a relative humidity of 0 to 100% (condensing) without performance degradation. B. The sensor unit components shall be designed for indoor use and meet the following requirements 1. Temperature: a. Operating: 10 C to 35 C (50 F to 95 F) b. Storage: 20 C to 70 C (-4 F to 158 F) 2. Humidity: a. Operating: 20% to 80% (relative, non-condensing) b. Shipping and storage: 5% to 85% (relative, non-condensing) 2.6 Reliability and Maintenance Requirements A. Sensor cables: The sensor cables shall provide a nominal service life of 20 years, excluding damage caused by non-environmental forces. B. Sensor unit: 1. The sensor unit modules shall have a predicted mean time between failures (MTBF) of greater than 87,000 hours. 2. The sensor unit shall be capable of performing internal self-diagnostic tests of the internal circuitry, cable continuity, and detection processing. 3. The sensor unit software shall be field-upgradeable. 2.7 Electrical Requirements A. Each sensor unit shall meet the following electrical requirements: 1. Input power: 100 to 240 VAC, 50/60 Hz 2. Power consumption: Less than 400W B. Backup power: The sensor unit shall be capable of being powered from a third-party uninterruptable power supply (UPS) or standby generator. C. The sensor cable shall include no conductive elements. D. The sensor cable shall be intrinsically safe within explosive atmospheres. Sept 3, 2014 Page 7 of 13 FLR1DA0315-001 Rev A

E. The sensor cable shall be completely immune to all forms of electromagnetic energy from radio communications, radar, electrical power transmission equipment and lightning. F. The system shall not require any outdoor power or grounding connections. 2.8 Detection Capabilities A. The PIDS sensor shall consist of fiber optic cable that is attached to the fence along the full length to be protected. B. The system shall be able to detect and locate intrusions over a cable distance of up to 2.5 km (1.6 miles). C. The sensor unit shall have the following detection capabilities: 1. Process the signal from the sensor cable to detect intruders attempting to breach the perimeter fence by cutting, climbing, or lifting the fence fabric 2. Locate the position of a detected intrusion to within the configured zone area. 3. Detect multiple simultaneous intrusions when intrusion attempts are in different zones. 4. Support up to 28 virtual detection zones. 5. Minimum configurable zone length is 30 m (98 feet). 6. Be capable of detecting and locating a sensor cable cut to within the affected zone. 7. Be capable of being calibrated to function on different types of metal fencing. 8. Utilize adaptive algorithms in the detection process to optimally discriminate between actual intrusions and environmental activity. D. Intrusion detection performance: 1. The probability of detection (Pd) of an intruder cutting the fence, lifting the fence fabric, or climbing unaided over the fence shall be 95% with a 95% confidence factor, when the system is installed in accordance with the manufacturer s directions on a high-quality fence. 2. False alarm rate: The maximum rate for alarms generated by the internal electronic processes of the processors (cables excluded) shall be less than one per zone per year, averaged over the total number of zones in the system. 3. Nuisance (environmental) alarms: a. The system when calibrated according to manufacturer s guidelines shall not suffer nuisance alarms from any of the following sources:.1 Temperature changes.2 Motion of nearby objects or vegetation that are not striking the fence.3 Motion of surface or ground water Sept 3, 2014 Page 8 of 13 FLR1DA0315-001 Rev A

.4 Sunrise/sunset.5 Acoustic or magnetic effects.6 Snow.7 Fog.8 Seismic vibration caused by nearby vehicular traffic.9 Seismic vibration caused by nearby rail traffic when the fence is further than 5 m (16 feet) from the rails. b. The system shall utilize advanced processing and ambient compensation to minimize the probability of nuisance alarms from the following sources:.1 Wind.2 Rain and hail.3 Sandstorms 4. Time to detection: a. The system shall be capable of generating an alarm within one second from the onset of an attempted breach that involves an aggressive contact with the system, such as the one attempted by quick climbing. b. Other detected intrusion attempts shall be reported no later than one second after the breach is completed. E. Fence compatibility: 1. The system shall support installation on the following types of metal fencing: a. Chain-link b. Expanded metal mesh c. Welded mesh d. Concertina and/or razor wire e. Vinyl-coated chain-link 2. It shall be possible to use multiple passes of sensor cable to obtain the specified detection performance for fences of any height. 3. The manufacturer shall provide installation guidelines regarding the type and height of fences that can be protected with one, two, and multiple passes of sensor cable. F. Gate compatibility: The sensor cable shall be capable of being installed on swinging gates. 2.9 Cable cut response A. The system shall support a self-healing sensor ring architecture. Sept 3, 2014 Page 9 of 13 FLR1DA0315-001 Rev A

B. The system shall be capable of detecting and locating a sensor cable cut to within the affected zone. C. In the event of a sensor cable cut, the system shall retain detection and location ability in the portion(s) of the sensor cable that remain connected to the system sensor unit. 2.10 Installation and Configuration Capabilities A. The system shall have the following characteristics, as a minimum: 1. The sensor cable must be capable of being attached directly to the fence without needing to be put in a conduit. 2. The sensor cable must be capable of being attached to the fence with standard UV-resistant cable ties (plastic or metal). 3. The system shall support the use of non-sensing lead in cable as long as the total length of the cable does not exceed 2.5 km (1.8 miles) B. The system shall support the following configuration and calibration features: 1. A Windows-based graphical user interface (GUI) 2. Configuration and calibration settings shall be capable of being stored in a computer file for record keeping purposes and available for reuse when configuring additional or replacement processors. 2.11 Networking Capabilities A. Network manager tools: The system s network management software shall provide the following tools to facilitate system commissioning and trouble-shooting: 1. System status tool that provides a visual display of the status of all processors in the system 2. System event log tool that provides a searchable log of system events. B. The system shall support an Ethernet RJ-45 connector as a physical media option for communication with the integrated sensor network. C. Network management: 1. The system shall include network management software to manage the communications over the sensor network. The network management software shall be capable of running on a standard Windows PC as well as on the sensor unit itself and be accessible via Windows Remote Desktop. 2. The system s network management software shall provide a TCP/IP-based interface for communicating alarm, status, and configuration data to and from security management systems. The system supplier shall furnish complete documentation of this interface to facilitate integration with security management systems. Sept 3, 2014 Page 10 of 13 FLR1DA0315-001 Rev A

2.12 Event Management A. The system shall provide a local PC-based operator interface with graphical alarm annunciation at the sensor unit. B. The system shall provide access to the following information and functionality when in a local or networked configuration: a. A user-configurable image depicting the protected site with a schematic, zone-based, perimeter overlay. b. Hardware monitoring and control c. Event detection and alarm generation (including flashing notification message, location marker, and audible alert) d. Basic alarm management e. Event and alarm logging f. Detection zone definition and configuration g. Adjustment of detection parameters C. The system shall support the following alarm management functions: 1. Maintain complete information on all alarms for 24 hours or until the alarm is cleared. 2. Alarms shall be cleared by local or remote operator or automatically in 24 hours after alarm generation. 3. Until cleared, the alarm information shall be compiled in a scrollable multicolumn table. 4. The maintained information shall include a. Unique alarm ID number b. Time label c. Event duration d. Event status e. Event strength f. Event zone 5. Operator shall be able to a. Select any of the alarms from the list b. Enter text notes regarding the cause of the alarm and the mitigation measures c. Clear the alarm 6. Operator notes as well as the alarm clearing event shall be recorded in the event log. Sept 3, 2014 Page 11 of 13 FLR1DA0315-001 Rev A

7. The system shall indicate the alarm location as a zone position along the sensor cable. 8. Event Logging: 2.13 Access Control a. The system shall maintain and display an event log, including alarms, system notifications, and user actions. b. The logs shall be periodically saved to the hard drive. c. A new set of log files shall be generated every 24 hours at midnight A. The system shall require the entry of a valid password at start-up and shutdown. B. The system shall divide user access into to three security levels: 1. Operator level for routine operation 2. Supervisor level for advanced system monitoring, configuration, and troubleshooting 3. Installer level for advanced configuration and troubleshooting Sept 3, 2014 Page 12 of 13 FLR1DA0315-001 Rev A

PART 3 EXECUTION 3.1 Site Assessment A. Before installation begins, the installation contractor shall provide a report to the facility s owner documenting any site conditions that may prevent the system from operating satisfactorily. Examples of such conditions include loose fence fabric, loose gates, or objects such as signs or tree branches hitting the fence. 3.2 System Installation A. The system shall be installed in accordance with the manufacturer s recommended procedures as defined in the manufacturer s documentation for the system. 3.3 System Calibration 3.4 Training A. The installation contractor shall calibrate the system in accordance with the manufacturer s recommended procedures as defined in the manufacturer s Product Guide. B. The installation contractor shall submit to the owner the calibration and configuration settings for the system. A. The installation contractor or vendor shall train the owner s maintenance personnel in the calibration and system maintenance procedures as given in the manufacturer s product documentation. Sept 3, 2014 Page 13 of 13 FLR1DA0315-001 Rev A