O C M III. Open Channel Flow Monitor



Similar documents
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Series DFMT Digital Paddlewheel Flowmeter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Flow Monitoring System

Regards from the Team at Rheology Solutions.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Multifunction devices

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Open channel & partially filled pipe Ultrasonic flow meters

Electronic Control Devices The European Product Catalogue 2007

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

BACnet Automation Interface Module (Network Version)

NETWORK ENABLED EQUIPMENT MONITOR

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

UTM10 Series Ultrasonic Transit-time Flowmeters

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Buckeye Detection Systems Fixed Detection Systems Application Survey

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

Interface Level And Point Level Analyzers & Sensors

Unidirectional Transmitter/ Receiver Units Introduction

Electronic Control Devices The European Product Catalogue 2007

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

For Multi-Parameter Meters see mvx

SECTION DETECTION AND ALARM

2.24. Pump Controller 704. Data Sheet

Long Distance Industrial Wireless Transmitters and Receivers

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Model: DC-A2IO Advanced HVAC Controller

USB-500 Series Low-Cost Data Loggers and Accessories

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

How To Use A Ds340 (Dsp)

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

USB-500/600 Series Low-Cost Data Loggers and Accessories

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Engineered for Accuracy and Simple Installation VANTAGE Ultrasonic Transit-Time Flowmeter

Sanitary Type Electronic Flow Switches

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL /179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

Thermatel Model TA1 Mass Flow Transmitter

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

WIRELESS INSTRUMENTATION TECHNOLOGY

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electronic Flow Switches

Galvanic Parts Per Million Dissolved Oxygen Systems

Wahl C50 Calibrator FEATURES

PRODUCT PROFILE FEATURES

SMART SENSOR COLLECTION

Typical Aluminum GFM Mass Flow Meter

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Sensing & Inspection Technologies. Applications. Features

Office of Integrated Security Systems Longwood University Camera System Standards

FCI ST75 Series Flow Meters

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Centro-Matic Automatic Lubrication Systems System Controls

FX07 Field Controller

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

FLOW HUNTER II & XDS 03

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

USB-500 Series Stand-Alone, Low-Cost Data Loggers

MechoNet TM Network Interface (MNI) Specification Submittal

Application/Connection Examples

TC 1818a. Operating Guide. Control Module SWM-015.5

SELECT MOUNT MONITOR

TAC I/NETTM. Process Control Unit

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Temperature & Humidity SMS Alert Controller

Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

IFC 070 Technical Datasheet

COMBIMASS. Technical Data COMBIMASS eco-bio +

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Duct Humidity Transmitter

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

Current Monitoring Kit QUICK START GUIDE

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Current Monitoring Kit

Flexible Counter Series in DIN size 24 x 48 mm

Multipoint Scanning Alarm System

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

PIEZOMETER AIRFLOW MEASURING RING

EQUIPMENT SPECIFICATIONS

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Transcription:

O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this item, the contractor shall furnish and install the OCM III as indicated on the plans and as herein specified. 1.2 Submittals A. The following information shall be included in the submittal for this section: 1. Data sheets and catalog literature for OCM III. 2. Interconnection and dimensional drawings. 3. Spare parts list and optional accessories. Part 2. Products 2.1 Ultrasonic Flow Transmitter and Sensor A. The flow transmitter shall be an ultrasonic microprocessor based echo-time measuring type providing an electrical output signal proportional to the flow rate, head, velocity or temperature as may be required. It shall consist of a noncontacting transducer and a transmitter connected by coaxial cable. B. Transducer 1. Operating principle: Acoustic impulses emitted from an ultrasonic sensor are reflected back from the liquid surface and are received by the sensor. The transit time of pulse travel for generation to echo is measured. This

elapsed time is proportional to the distance between the sensor and liquid surface. 2. Primary Sensor: 3. Mounting The acoustic sensor/transducer shall have polarized zirconium crystal with acoustic impedance matching face and transformer. The transducer shall be approved by FM for Class I and Class II hazardous locations. A separate temperature probe shall be provided for temperature compensation. The transducer shall be a Milltronics Echomax model XRS-5. A one inch NPT fitting per manufacturers recommendations. 4. Operating Temperature: C. Transmitter 1. Enclosure -40 o F to 200 o F Nema 4X Polycarbonate 2. Power Supply 110/115/200/230 VAC +/- 15%, 50/60 Hz @ 13 VA max, 9-30 VDC @ 8 Va max. 3. Power consumption 13 VA max 4. Operating Temperature -4 o F to 140 o F

5. Outputs Analog 4-20 madc or 0-20 madc, operator selectable, into 1000 ohms isolated 3 output relays, rated @ 8A, SPDT, 250 VAC, noninductive 6. Communications 7. Software 8. Controls 5 language selectable User interface via detachable IR keypad programmer RS 232C compatible serial port-general purpose port for programming or extraction of program data or log data, capable of periodic input to serial printer with selectable baud rates of 300, 600, 1200, 2400, 4800, 9600 or 19200 Bi-Polar 20mA current loop Software shall be provided to permit user interface with IBM compatible computers to enable programming, extraction of program data to a file, downloading of data log to a file and conversion of data to a text or spreadsheet format. All data and operating parameters may be entered via the detachable IR keypad or from a remote computer via the RS 232C port. D. Sensor and Transmitter Performance 1. Range 1-10 feet

E. Display 2. Accuracy 3. Resolution 4. Separation Range sensor error: +/- 1.0 mm/m Calculation error: less than 0.02% 0.2 mm Current output 5 ua, 12 bit Maximum distance of 600 between electronics and transducer without additional equipment. Two line alphanumeric LCD type with LED backlighting, displaying the following: 1. Current head in selected units 2. Current flowrate in selected units 3. Total flow in selected units 4. Velocity (If velocity sensor attached) 5. Current temperature 6. Max and Min temperatures 7. Max and Min flowrates 8. Relay status 9. Logged data 10. Day, Date and Time 11. All operational parameters Sensor and Transmitter shall be Milltronics Open Channel Monitor OCM III with XRS-5 Echomax Transducer as manufactured by Milltronics Inc. Part 3. Operator Functions 3.1 Calibration A. Calibration of the flow transmitter shall be accomplished by the entry of all operating data through the detachable IR keypad or with a remote computer via the RS232C port. Access to the parameters shall be protected by a customer programmable security code number.

B. Internal self-diagnosis shall be available to assist in maintenance of the flow transmitter. Diagnostics shall be accessible through the RS 232C port. C. The flowmeter shall be capable of providing for the simulation of head heights and correlating flowrate to ensure that operating parameters are in accordance with the owners/manufacturers primary element flowrate chart. D. The flowmeter shall be capable of monitoring flow through any primary device utilizing the ratiometric or absolute method of calculation or by use of a customer definable flow calculation program using a cubic spline curve. E. The flowmeter, when required, shall be capable of taking an input from a velocity sensor and calculating flow based on area/velocity. F. The flowmeter shall be capable of taking a 0-5 VDC input from an auxiliary device other that its own transducer to calculate and log flow data. 3.2 Transmitter Function Details A. Log data at customer selectable fixed or variable logging rates of 1 minute to a maximum of 24 hours for a minimum of 31 days up to 2.2 years. B. Log average flowrate at interval selected. In addition to flowrate, log flow total for 24 hour period, high and low flows and time of events, site identification number and date & time. Log format shall be ASCII or data base manager (spread sheet compatible). C. The flowmeter shall be capable of programming a variable rate log to increase the log rate due to preset flowrate increases and return to original rate when flows return to normal. D. All data and operational parameters shall be protected to prevent loss should a power failure occur by a dual back-up system utilizing a super capacitor for up to 10 hour protection and a lithium battery for long term protection. E. Unit shall provide for automatic restart after power is restored without operator assistance.

Part 4. Execution 4.1 Installation A. Follow manufacturers recommendation for the minimum separation between the sensor and maximum expected liquid level. B. Mount the sensor to ensure a clear path to the liquid surface. C. The sensor may be flange mounted if a stilling well is required. D. Wiring between the sensor and transmitter shall be routed in grounded metal conduit. Use cable type and procedures as manufacturers recommendations. Part 5. Warranty 5.1 Terms A. The manufacturer of the above specified equipment shall guarantee for twenty four (24) months from equipment startup or thirty (30) months from date of shipment, whichever occurs first, that the equipment shall be free from defects in design, workmanship or materials. Part 6. B. In the event a component fails to perform as specified or is proven defective in service during the warranty period, the manufacturer shall promptly repair or replace the defective part at no cost to the owner. Options 6.1 Related Equipment A. Velocity Sensor B. The Probe C. RG62U cable for transducers

Part 7. Spare Parts 7.1 Recommended Spare Parts A. Box of 5 fuses B. Battery C. Calibrator