is then retained absolutely without interruption.



Similar documents
Actuator-Sensor-Interface

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

PHOENIX CONTACT - 01/2007

SITOP UPS1600 / UPS1100. SITOP power supply SITOP UPS1600 / UPS1100. Overview. Safety information. Description, device design, dimension drawing 2

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

TX OPEN RS232/485 module

Redundancy Module QUINT-DIODE/40

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PCS0100en Persy Control Services B.V. Netherlands

instabus KNX / EIB System System E F G H

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Rack mounted telephone- and leased line modem for industrial applications

Telephone- and leased line modem for industrial applications TD-36

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Product and functional description

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Three-phase monitoring relay CM-PFE

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ZC-24DO CANopen I/O Module: 24 Digital Outputs

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Vibration Monitoring System Adash 3600

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

I STAR COMPUTER CO., LTD

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Preset Counter signo 721

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Liquid Level Limit Switch liquiphant T FTL 20

PHOENIX CONTACT Features

Modular I/O System Analog and Digital Interface Modules

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

SYSTEM DESCRIPTION Termination Boards

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

DALI RC BASIC SO. Control unit Operating instructions

User manual Rev. 1.2 (17/04/2015)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

MINI MCR-SL-R-UI(-SP)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Power Supplies 3. SDN-P DIN Rail Series

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

TORKEL 820 Battery Load Unit

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Safety technique. Emergency stop module BO 5988 safemaster

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Digital input modules

Application/Connection Examples

How To Use A Power Supply Unit (Upu)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Belimo Gateway MP to Modbus RTU - UK24MOD

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Mobile Data Power Model: MDP-25

Drayton Digistat +2RF/+3RF

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

BB800 Off-Grid Solar System

connecdim Gateway G1 Ethernet TCP/IP to DALI

Emergency lighting units EM powerled

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

3000W Single Output Power Supply

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Operating Manual UWAPS-TINY Series

Online UPS. PowerWalker VFI 1000R/1U

Series Six Plus Programmable Controller

HCR3.2/.. Chipcard reader HOTEL SOLUTION

J TB/TW Temperature limiter, temperature monitor

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

38 Series - Relay interface modules A

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Uninterruptible Power Supply

SVR 12/24V and SVR Akku 12V Installation instructions

Electronic Pressure Switch EDS 3000

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

38 Series - Relay interface modules A

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

3000W Single Output Power Supply

Transcription:

Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection of the batteries as soon as the DC UPS input voltage drops below the value set using DIP switches High safety and availability through monitoring of operational readiness, battery supply line, battery aging (message "Battery replacement necessary") and battery charge (message "Battery charge >85%") Support of automatic restart of industrial PCs through selectable switch-off response. Optionally with serial or USB interface. SW tool as download at http://www.siemens.de/sitop executes under WinNT4.0, Win2000 and WinXP. The following timing diagrams show examples of the characteristic of the input and output voltages at the terminals of the DC-UPS module as well as the signal chart of the signals (relays) and of the remote signal (port). "Long" voltage failure with DC UPS without serial or USB port (Fig. 1) Voltage return only once buffer time tp (t3 follows t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". At the same point in time t1, the buffer time tp set on the DIP switches is started automatically. The fact that the DIP switch is set to "Interruption output U out " in this example has no effect because the input voltage returns at time t3 only once the set buffer time (time t4) has expired. "Short" voltage failure with DC UPS without serial or USB port (Fig. 2) Voltage return before buffer time tp (t3 before t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply,

Page 2 of 11 and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". At the same point in time t1, the buffer time tp set on the DIP switches is started automatically. With the DIP switch set to "Interruption output U out ", the output voltage U out is automatically interrupted for 5 s once the set buffer time tp (time t4) has expired. The accumulator has already been disconnected because the input voltage has returned at the time t3. If the DIP switch is not set to "Interruption output U out " there is no interruption in this example because the input voltage has already returned at time t3 prior to expiry of the set buffer time (time t4). Buffer time (time t4) automatically interrupted for 5 s and the accumulator, which has not yet been disconnected because of the missing input voltage, is simultaneously disconnected from the output. Fig. 1 "Long voltage failure" Fig. 2 "Short voltage failure" DC UPS without serial or USB port (6EP1931-2DC21/2EC21) DIP switch positions on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7)//t = according to setting (with bottom row no. 1 to left)/xxxx = with setting for interruption U out (with bottom row no. 8 to left) Legend: U in :input voltage at terminals X1.1 X1.2 U out :output voltage at terminals X1.3 X1.4 and X1.5 - X1.6 OK:signal for input voltage U in OK or above the set accumulator connection threshold

Page 3 of 11 Bat: signal for battery operation (accumulators connected to output, accumulators power the load) Remote: signal for remote timer start with signal level = 0 at pin 7 of 9-pin serial port (pin 7 is usually the positive power supply for the port) t1: input voltage U in failed or fallen below set connection threshold t2: buffer time set on DIP switches is started by remote timer start (signal level = 0) t3: input voltage U in rises above set connection threshold t4: end of set buffer time (output is switched off and/or accumulator is disconnected) t5: output is connected again 5 s after shutdown tp: buffer time set on the DIP switches (bottom row nos. 2 to 7) "Long" voltage failure with DC UPS with serial or USB port (Fig. 3) Voltage return only once buffer time tp (t3 follows t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". The buffer time tp set on the DIP switches is started at the user-selectable time t2 by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial port following previous signal chart according to operating instructions). The fact that the DIP switch is set to "Interruption output U out " in this example has no effect because the input voltage returns at time t3 only once the set buffer time (time t4) has expired. Note: Without a remote signal level = 0 with a setting t = max. duration, there is no interruption to the output voltage in this case because the set buffer time is not started (or interruption only if the exhaustive discharge protection disconnects the accumulator and the input voltage has not returned by then). "Short" voltage failure with DC UPS with serial or USB port (Fig. 4) Voltage return before buffer time tp (t3 before t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". The buffer time tp set on the DIP switches is started at the user-selectable time t2 by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial port following previous signal chart according to operating instructions). With the DIP switch set to "Interruption output U out ", the output voltage U out is automatically interrupted for 5 s once the set buffer time tp (time t4) has expired. The accumulator has already been disconnected because the input voltage has returned at the time t3. The interruption to the output voltage U out for 5 s permits an automatic restart for many industrial PCs, even if the line voltage (or the input voltage U in on the DC-UPS module) returns during shutdown of the PC, as in this example. Note: Without a remote signal level = 0 with a setting t = max. duration, there is no interruption in the output voltage here because the set buffer time is not started.

Page 4 of 11 Fig. 3 "Long voltage failure" Fig. 4 "Short voltage failure" DC UPS with serial or USB port (6EP1931-2DC31/-DC42/-2EC31/-2EC42) DIP switch positions on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7)/t = max. time (with bottom row no. 1 to left)/interruption of U out (with bottom row no. 8 to left) Legend: U in :input voltage at terminals X1.1 X1.2 U out :output voltage at terminals X1.3 X1.4 and X1.5 - X1.6 OK:signal for input voltage U in OK or above the set accumulator connection threshold Bat: signal for battery operation (accumulators connected to output, accumulators power the load) Remote: signal for remote timer start with signal level = 0 at pin 7 of 9-pin serial port (pin 7 is usually the positive power supply for the port) t1: input voltage U in failed or fallen below set connection threshold t2: buffer time set on DIP switches is started by remote timer start (signal level = 0) t3: input voltage U in rises above set connection threshold t4: end of set buffer time (output is switched off and/or accumulator is disconnected) t5: output is connected again 5 s after shutdown tp: buffer time set on the DIP switches (bottom row nos. 2 to 7)

Page 5 of 11

Page 6 of 11 DC-UPS module 15 Order number 6EP1 931-2EC21 6EP1 931-2EC31 (with serial port) 6EP1 931-2EC42 (with USB port) Input L+/M in normal operation Rated voltage U in rated 1) Voltage range Connection threshold for accumulator Rated current I in rated Controlled DC voltage 24 V DC 22 V to 29 V DC 22.5 V DC ±0.1 V (factory setting), adjustable in the range 22 V to 25.5 V DC (in 0.5-V steps) 15 A + approx. 1 A with empty accumulator Line buffering Line buffering or buffer time On/off control circuit Buffering time Dependent on connected accumulator and load current: With battery module 3.2 Ah (6EP1935-6MD11) at +25 C: approx. 45 s. at 15 A; 1.5 min. at 10 A; 13 min. at 5 A With battery module 7 Ah (6EP1935-6ME21) at +25 C: approx. 7 min. at 15 A; 15 min. at 10 A; 38 min. at 5 A External isolated NO contact required (loading max. 15 V DC/max. 10 ma). With an open control circuit, the accumulator is isolated from output L+, thus canceling line buffering. Adjustable using DIP switches to a maximum buffering time up to forced shutdown through exhaustive discharge protection (at approx. 19 V) or to a time limit of 5 to 635 s (in 10-s steps) Output L+/M in normal operation Rated voltage U out rated Voltage range Output current Dynamic current with overload Dynamic current with shortcircuit 24 V DC (output voltage of SITOP power supply) Input voltage U in less approx. 0.5 V DC 0 A to 15 A Electronic current limitation to 1.05 to 1.4 x I out for approx. 80 ms, then electronic rated shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Electronic current limitation to 1.5 to 3 x I out rated for approx. 20 ms, then electronic shutdown of

Page 7 of 11 the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Output L+/M with battery operation Rated voltage U out rated Approximate voltage range Output current I out Dynamic current with overload Dynamic current with shortcircuit Output +Bat/-Bat in normal operation End-of-charge voltage U Load current I 24 V DC (from battery module) 27 V to 19 V DC at I out = 0.05 x C x 1/h or 24 V at I out = 1 x C x 1/h or 23 V at I out = 2 x C x 1/h (C = total connected accumulator capacity in Ah), 19 V disconnection threshold for exhaustive discharge protection 0 A to 15 A (constantly permissible) Electronic current limitation to 1.05 to 1.4 x I out for approx. 80 ms, then electronic rated shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Electronic current limitation to 1.5 to 3 x I out rated for approx. 20 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) CVCC charging characteristic (first constant current then constant voltage) 27.0 V DC ±0.1 V (factory setting),adjustable in the range 26.3 to 29.3 V (in 0.1-V steps) Approx. 0.7 A (factory setting), â adjustable to 0.35 A or 0.7 A (charging is carried out with closed and open on/off circuit) Efficiency/heat loss At U out rated, I out rated approx. With accumulator operation, approx. 96.2%/14 W 96%/15 W Protection and monitoring Reverse-polarity protection Overload protection Short-circuit protection Against polarity reversal on input voltage and accumulators Electronic current limitation to 1.05 to 1.4 x I out for approx. 80 ms, then electronic rated shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Electronic current limitation to 1.5 to 3 x I out rated for approx. 20 ms, then electronic shutdown of

Page 8 of 11 the output with automatic restart attempts (approx. 20-s intervals between restart attempts). Built-in, inaccessible 16 A fuse Exhaustive discharge protection Monitoring "Wire breakage in accumulator circuit" Monitoring "Accumulator replacement required" Monitoring "Accumulator charge status > 85%" Automatic shutdown if accumulator voltage below approx. 19 V Alarm signal if accumulator circuit not closed or if it opens during operation (cyclic check approximately every 20 s) Alarm signal flashing at approx. 0.25 Hz (approx. 2 s alarm, approx. 2 s no alarm, approx. 2 s alarm, etc.). Check every 4 hours if there has been no buffering or shutdown within 4 hours Signal to indicate that accumulators are charged to at least 85% of rated capacity Signaling 2) Normal operation Buffering or battery operation (accumulator supplies load alone or in addition to PS in the case of overload) Alarm (buffer not ready, or prewarning at and above < 20.4 V accumulator voltage) "Accumulator replacement required" "Accumulator charge status > 85%" Green LED (OK) and isolated changeover contact "24 V DC OK/Bat" at setting "24 V DC OK" 3) Yellow LED (Bat) and isolated changeover contact "24 V DC OK/Bat" at setting "Bat" (= off position) Red LED (alarm) and isolated changeover contact at setting "Alarm" (= off position). Causes of the buffer not being ready during normal operation can include:off status or open on/off control circuit, battery module not connected, polarity reversal or defective accumulator (accumulator voltage < 18.5 V) or wire breakage between accumulator and uninterruptible-power-supply module.signal is scanned and, thus, updated, every 20 s. Causes of the buffer not being available during buffer operation include: Accumulator voltage has dropped below 20.4 V DC (= prewarning before shutdown through exhaustive discharge protection) and shutdown of the accumulator due to overload, short-circuit, exhaustive discharge protection or expired buffer time. The red LED then goes out. Red LED (alarm) flashing at 0.25 Hz and isolated changeover contact (alarm) switching at approx. 0.25 Hz Second green LED (Bat > 85%) and isolated NO contact closed (off position = open) Optional port and software

Page 9 of 11 Serial port Only on 6EP1 931-2EC31 Output of all signals and receipt of the "Remote Timerstart signal. Technical design: PCcompatible. 8N1 send and receive, 9600 baud, 8 data bits, 1 stop bit, no parity bit. Required connection to PC: 1 : 1 interconnected 9-pole sub D extension cable (connector/socket), only pin 2 (RXD), pin 3 (TDX) and pin 7 (RTS) are required. USB port Only on 6EP1 931-2EC42 Output of all signals and receipt of the "Remote Timerstart signal. Technical design: Specification 2.0 with full speed, i.e., 2 Mbit/s. Supplied with +5 V by DC UPS ("selfpowered"). Required connection to PC: Commercially available 4-core shielded cable, 90 Ohm, max. 5 m, USB series "A" connector to PC and USB series "B" connector to DC UPS Software A software tool (runs under WinNT 4.0, Win 2000 and WinXP) for reading out and processing the signals is available to download from the Internet at http://www.siemens.de/sitop This site also provides more information on the port. Control signals On/off control signal "Remote Timerstart" via serial port or USB Buffering is terminated or the accumulator is disconnected from the output by opening the control circuit (or by using DIP switches on the device).all other functions are retained. Starts line buffering for the set buffer time Security Primary/secondary galvanic isolation Protection class (EN 60950) No Class III (ext. circuit and power-supply unit: safety extra-low voltage required in accordance with EN 60950) EMC Emitted interference Radio interference suppression in accordance with EN 55022, limit-value curve B Noise immunity Noise immunity in accordance with EN 61000-6- 2 Ambient conditions Ambient temperature during operation 0 C to +60 C with natural convection

Page 10 of 11 Transport/storage temperature Degree of protection (EN 60529) -40 C to +70 C IP20 Humidity class Conditions of use in accordance with EN 60721, climate class 3K3 (relative humidity 5% to 85% Approvals and absolute humidity 1 g/m 3 to 25 g/m 3 ; no condensation) CE UL/cUL CE conformity in accordance with 89/336 EEC UL 508/CSA C22.2, file E197259 Mechanical system Input connections 24 V DC Output connections 24 V DC Accumulator-module connections 24 V DC Connections for control circuit and signals Dimensions (W x H x D) in mm Required clearances Weight Mounting 2 screw-type terminals for 1 mm to 4 mm 2 /17 to 11 AWG 4 screw-type terminals for 1 mm to 4 mm 2 /17 to 11 AWG 2 screw-type terminals for 1 mm to 4 mm 2 /17 to 11 AWG 10 screw-type terminals for 0.5 mm to 2.5 mm 2 /20 to 13 AWG 50 x 125 x approx.125 50 mm above and 50 mm below the device Approx. 0.4 kg (with serial or USB port:approx. 0.45 kg) Snaps onto DIN rail DIN EN 50022-35x15/7.5 1) All SITOP 24 V DC power supplies are permissible without restriction. 2) Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A 3) "24 V DC OK" means: voltage of the power-supply unit is greater than the accumulator connection threshold set on the DC-UPS module 15.

Page 11 of 11