FIRE SAFETY INSPECTION REPORT



Similar documents
FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

build safe live safe

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

General Fire Code Requirements Within Commercial Tenant Spaces

Fire Alarm Systems Requirements by Occupancy Type

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Fire Protection and Life Safety at the Library of Congress

The New Life Safety Chapter What It Applies to and How Organizations Can Comply with It

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Bemidji State University Building Emergency Preparedness Plan. Building Representatives. Contact Points. Building: Department: Room(s):

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Classroom Door Security & Locking Hardware

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

2007 ICC FINAL ACTION AGENDA

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Summary of Preliminary Assessment on Structural, Fire and Electrical Safety

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

INSPECTION AND TESTING FORM

Life Safety Code Enabling References

Miami Beach Building Department

Greater Orlando Aviation Authority Buildings. Orlando International Airport Orlando, Florida, USA

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Commercial Fire Inspections

Module 5. Fire and Emergency Alarm System Part I- Basics

HERNANDO COUNTY FIRE ALARM GUIDELINES

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Sample Written Program. For. Flammable Liquids

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

CHILD CARE CENTER INFORMATION SHEET

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section , to read as follows:

Building Permit, Fire Inspection and Operating Permit Fee Schedule

Name Of Occupancy Date. Yes No Describe

Building Control Guidance Note

City of San Antonio (COSA) Boarding Homes Fire Sprinkler System Training

FIRE PREVENTION DEPARTMENT. CONTAINMENT/RESTORATION UCDHS ILSM Procedure For Water Damage Repair

Evaluation of H&M Compliance with Safety Action Plans for Strategic Suppliers in Bangladesh

FIRE AND LIFE SAFETY TRAINING

Is the Apartment in my House Legal?

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

Print Shop/Mail Room

NEW YORK CITY FIRE DEPARTMENT

ICC CODE CORNER 2012 IFC Code & Commentary

Overview of Hotel Fire Safety Requirements

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Errata has been identified as follows:

VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING FEBRUARY 4, 2014 AGENDA

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Sample Company SECTION GENERAL COMMISSIONING REQUIREMENTS PART 1 GENERAL 1.1 SUMMARY AND CONTRACT RESPONSIBILITIES

NEW YORK CITY FIRE DEPARTMENT

ADMINISTRATIVE SERVICES MANUAL

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Office of the State Fire Marshal. Fire Rated Doors

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

How To Install A Carbon Monoxide Detector

Global Leaders in Fire Engineering. Company Overview. Finding simple solutions to complex problems.

NFPA Edition Fire dampers shall be permitted to be installed in exhaust systems in the following situations:

Winnipeg Fire Department Fire Prevention Branch

Mobile Fire Rescue Department Bureau of Fire Prevention

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems

Notes. Material 1. Appropriate Flammable Liquids

Effective June 27, TEXT (CO Detection Commercial Buildings)

FIRE ALARM APPLICATION

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Commissioning of Fire Protection and Life Safety Systems. Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

Daycare Center Fires

F.Y.I. Specifying Fire Protection Systems Using Division 13

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

FIRE SAFETY ONLINE TRAINING

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

FIRE SAFETY RISK ASSESSMENT

Duke University Hospital Fire/Life Safety Management Plan 2007

2010 FLORIDA BUILDNG CODE, FIRE AND LIFE SAFETY i

Environment of Care Fire Safety Management Plan 2014

FIRE SAFETY REQUIREMENTS

FORM 20A.9 SAMPLE AUDIT PROGRAM FOR TESTING IT CONTROLS. Date(s) Completed. Workpaper Reference

City of Columbus Department of Building and Zoning Services

WORKING GUIDE 1996 FROM HOME. WorkCover. Watching out for you. New South Wales Government

Fire Barriers & Fire Stopping

Indiana Building Rehabilitation Standard

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

For use by landlords of small premises Premises Address

Transcription:

FIRE SAFETY INSPECTION REPORT M.I.T APPARELS LTD PATHANTULY, GODNAIL, SHIDDIRGONJ, NARAYANGONJ OTHER FACTORIES: NONE June 4, 2014

Page 2 SUMMARY was surveyed for fire safety on 6/4/2014 by Hughes Associates, Inc. This summary identifies the major deficiencies that were identified during the inspection. The purpose of this survey was to identify significant fire safety issues and to provide recommendations for remediation based on applicable standards specified by the Accord. The scope of this initial fire safety inspection was limited to the review and identification of major fire safety issues. The inspection did not include identification of minor deficiencies, which will be further addressed as part of follow-up inspections. Tables 1-3 summarizes the major fire safety issues identified during the inspection. Recommendations have been provided to address each issue. An implementation schedule shall be developed by the factory to remediate each of the findings. The specific timing of improvements, including any requested extensions due to design / installation constraints, shall be submitted to the Accord for approval.

Page 3 Table 1. Findings And Recommendations - Sewing Shed No. Category Finding Recommendation Remediation Timeframe F-1 Fire Rated Construction Store room used for combustible storage are not separated by firerated construction. Provide dedicated storage rooms separated by minimum 1-hr fire-rated construction. F-2 Egress Egress doors with locking features are provided at building exits. Remove locking features from all egress doors. If locks are required for security reasons, utilize special door locking features complying with NFPA 101. Immediate

Page 4 F-3 The fire alarm system is antiquated, not a listed system, and does not provide alarm and notification features consistent with acceptable standards. Replace the fire alarm system with a new, listed addressable fire alarm system in accordance with NFPA 72. Design within 4, install within 9 F-4 Inspection, testing, and maintenance for the fire alarm system were not in accordance with NFPA72. Inspect, test and maintain the fire alarm system, and keep written records on-site, in accordance with NFPA 72. F-5 The building is equipped with single-station smoke alarms. Smoke alarm activation sounds only a local alarm and does not provide automatic fire alarm notification of occupants. Replace the single-station smoke alarms. Provide automatic smoke detectors throughout the building in accordance with NFAP72. Within 6

Page 5 F-6 Egress Lighting Inspection, testing, and maintenance for the emergency lighting system were not in accordance with The ACCORD standard. Inspect, test and maintain the emergency lighting system in accordance with The ACCORD standard. Keep written records on-site.

Page 6 Table 2. Findings And Recommendations - Knitting Shed No. Category Finding Recommendation Remediation Timeframe F-1 Fire Rated Construction Store room used for combustible storage are not separated by firerated construction. Provide dedicated storage rooms separated by minimum 1-hr fire-rated construction. F-2 Egress Egress doors with locking features are provided at building exits. Remove locking features from all egress doors. If locks are required for security reasons, utilize special door locking features complying with NFPA 101. Immediate

Page 7 F-3 The fire alarm system is antiquated, not a listed system, and does not provide alarm and notification features consistent with acceptable standards. Replace the fire alarm system with a new, listed addressable fire alarm system in accordance with NFPA 72. Design within 4, install within 9 F-4 Inspection, testing, and maintenance for the fire alarm system were not in accordance with NFPA72. Inspect, test and maintain the fire alarm system, and keep written records on-site, in accordance with NFPA 72. F-5 The building is equipped with single-station smoke alarms. Smoke alarm activation sounds only a local alarm and does not provide automatic fire alarm notification of occupants. Replace the single-station smoke alarms. Provide automatic smoke detectors throughout the building in accordance with NFAP72. Within 6

Page 8 F-6 Egress Lighting Inspection, testing, and maintenance for the emergency lighting system were not in accordance with The ACCORD standard. Inspect, test and maintain the emergency lighting system in accordance with The ACCORD standard. Keep written records on-site.

Page 9 Table 3. Findings And Recommendations - Finishing Shed No. Category Finding Recommendation Remediation Timeframe F-1 Fire Rated Construction Store room used for combustible storage are not separated by firerated construction. Provide dedicated storage rooms separated by minimum 1-hr fire-rated construction. F-2 Fire Rated Construction The boiler room is not separated by fire-rated construction (openings, non-rated doors, penetrations). Separate the boiler room by a minimum 2-hr fire-rated construction. Seal and/or protected all openings to maintain the required fire separations

Page 10 F-3 Egress Egress doors with locking features are provided at building exits. Remove locking features from all egress doors. If locks are required for security reasons, utilize special door locking features complying with NFPA 101. Immediate

Page 11 F-4 The fire alarm system is antiquated, not a listed system, and does not provide alarm and notification features consistent with acceptable standards. Replace the fire alarm system with a new, listed addressable fire alarm system in accordance with NFPA 72. Design within 4, install within 9 F-5 Inspection, testing, and maintenance for the fire alarm system were not in accordance with NFPA72. Inspect, test and maintain the fire alarm system, and keep written records on-site, in accordance with NFPA 72. F-6 The building is equipped with single-station smoke alarms. Smoke alarm activation sounds only a local alarm and does not provide automatic fire alarm notification of occupants. Replace the single-station smoke alarms. Provide automatic smoke detectors throughout the building in accordance with NFAP72. Within 6

Page 12 F-7 Egress Lighting Inspection, testing, and maintenance for the emergency lighting system were not in accordance with The ACCORD standard. Inspect, test and maintain the emergency lighting system in accordance with The ACCORD standard. Keep written records on-site.