UPS SYSTEMS. Tripp Lite UPS Systems. Introduction. Network/Server UPS Systems. Network Power Management. Desktop UPS Systems. Integrated Solutions



Similar documents
UPS SYSTEMS. Tripp Lite UPS Systems. INDEX Intelligent, Line-Interactive Operation

UPS SYSTEMS. Tripp Lite UPS Systems. Introduction. Network/Server UPS Systems. Network Power Management. Desktop UPS Systems. Integrated Solutions

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Model #: SMART2200CRMXL

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course Tripp Lite.

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Tough Decision: On-Line or Line-Interactive UPS?

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

DATA CENTER SOLUTIONS

Internet Office 500VA Tower Standby 120V UPS with USB port

Practical Power Guidelines for VoIP and Internet Telephony Applications

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Internet Office UPS System Standby UPS for PCs, workstations and more

BC Pro UPS System Standby UPS System

The CyberPower Story. A History of Firsts. Global Distribution UPS SYSTEMS

Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications

Uninterruptible Power Supply

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

PowerGem Pro Uninterruptible Power Supply

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Common Power Problems & Power Protection Solutions

LAP ENERGIA PARA DATACENTERS

Product Snapshot. Powerware 5125 Family Uninterruptible Power System. Introducing the expanded Powerware 5125 family of UPSs.

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Smart-UPS On-Line 230 V

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

TABLET/CHROMEBOOK CHARGING STATIONS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

USER MANUAL Online UPS 1K/2K/3K Rack

Choosing Close-Coupled IT Cooling Solutions

Eaton 93PM UPS Efficient. Scalable. Innovative.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

QuickSpecs. Compaq Uninterruptible Power Systems M ODELS

HEALTHCARE / MEDICAL SOLUTIONS

Dell Smart-UPS 1,500 3,000 VA

USER MANUAL Online UPS 1K/2K/3K

R5000 Uninterruptible Power System (UPS) Overview

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Back-UPS Pro 1300/1500 Installation and Operation

R5000 Uninterruptible Power System (UPS) Overview

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Rack Power Distribution

Installation and Operation Back-UPS 1250, 1300, 1500

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Top 8. Considerations for Choosing the Right Rack Power Distribution Unit to Fit Your Needs

MAJORSINE Power Inverter

HP UPS R1500 Generation 3

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

How To Power A Bladecenter H Servers

RUNNING A BUSINESS IS FUN, BUT IT S ALSO HARD WORK

How To Install A Power Supply (Uplast) With A Battery Pack

Rack Power Distribution. Worldwide

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Online UPS. PowerWalker VFI 1000R/1U

QuickSpecs. Models HP Server Console Switches

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Eaton 93PM UPS Efficient. Scalable. Innovative.

Cisco Nexus 7000 Series Power Supply Modules

INTEGRATED SOLUTIONS. FREE IT Infrastructure Assessment. Tripp Lite Integrated Solutions

RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

HP R12000 and R18000 DirectFlow UPS User Guide

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Server Technology, Inc.

User Manual 1K/2K/3K Online UPS

HP Server Console Switch with Virtual Media Overview

Power Commander Power Distribution Units from Wiremold/Legrand offer

Series IDU/IDF. Refrigerated Air Dryer

Transcription:

UPS SYSTMS Tripp Lite UPS Systems Reliable, efficient, manageable power and battery backup Introduction ow to hoose a UPS System 2-3 UPS eature omparison 4-5 Network/Server UPS Systems LIN-INTRTIV OPRTION SmartPro Rack/Tower UPS 6-9 SmartPro Shallow-epth Rack UPS 10-11 SmartPro Tower UPS 12-13 ON-LIN OPRTION SmartOnline Rack/Tower UPS 14-19 SmartOnline Tower UPS 20-21 SmartOnline Modular 22-25 3-Phase Tower UPS SmartOnline 3-Phase Tower UPS 26-29 Network Power Management Powerlert Software 30-31 esktop UPS Systems LIN-INTRTIV OPRTION Tower and Low-Profile UPS 32-33 STNY OPRTION Tower and Low-Profile UPS 34-35 Integrated Solutions Racks, ooling, PUs, KVMs 36 and ables

OW TO OOS UPS SYSTM It would be nice if utility power was always reliable, but it isn t. etween the aging grid, growing demand, severe weather and hazards lurking inside your own walls, your equipment is under constant attack. You can prevent equipment damage, data loss and downtime by installing a UPS system to regulate incoming power and provide battery backup during outages. Whether you re supporting racks of mission-critical servers in your data center or a single desktop computer in your home office, Tripp Lite can provide the UPS you need to get the job done. nd with Tripp Lite, you ll get more for your money. ut with so many models to choose from, how can you determine which UPS is best for your application? onsider the five questions on the next page to help you choose. IN IT ST! Try our interactive UPS selector guide at www.tripplite.com/upsguide 2

ive asic Questions to onsider When hoosing a UPS System 1. o you need a Network/Server UPS or a esktop UPS? Network/Server UPS Systems protect equipment in high-availability environments like data centers. esktop UPS Systems protect computers, peripherals and other electronics in your home or office. You need a Network/Server UPS if you answer yes to any of these questions: Will the UPS support mission-critical equipment? Will the UPS support a load higher than 750 watts? Will the UPS be installed in a rack or rack enclosure? oes your equipment require pure sine wave power? o you want the UPS to have expandable runtime? Will the UPS support high-voltage (200-250V) loads? 2. ow much UPS capacity do you need? To estimate capacity requirements, add up the wattage of all the equipment you plan to connect. (Refer to the equipment manufacturer s documentation to find the wattage. If output is listed in amps, multiply by the voltage to estimate wattage. If you can t find documentation, refer to the equipment nameplate.) heck the UPS system specifications to see which models will handle your requirements. Note: This method provides a rough estimate, but we recommend that you use our UPS product selector at www.tripplite.com/upsguide or contact your Tripp Lite representative for a more precise estimate. 3. Which input and output power connections do you need? heck the UPS specifications to make sure the UPS can connect to a compatible circuit/outlet in the installation location. You also need to make sure the UPS system s outlets match the plugs and voltage requirements of your equipment. You can provide additional outlets, placement flexibility and management capabilities by connecting one or more Tripp Lite PUs to the UPS output. 4. ow much battery backup runtime do you need? With an 80% load, included UPS batteries typically provide five to ten minutes of runtime. That s long enough to outlast most outages. If you need additional runtime, choose a UPS system that supports connecting external battery packs. o to www.tripplite.com/runtime for interactive battery backup runtime charts for every UPS model. You can see how battery pack options affect runtime at any wattage level, download traditional runtime chart Ps and determine the wattage requirements of your equipment. 5. What other UPS features do you need? Tripp Lite manufactures more than 200 different UPS systems suitable for a wide range of applications and budgets. See pp. 4-5 for a comparison of the key features available in each UPS family. 3

UPS TUR OMPRISON esktop UPS Systems XTR PROTTION / IR PITY XTR PROTTION / Standby Line-Interactive Line-Interactive / Protection Protection On-Line Protection O-UPS, Internet Office, OmniSmart, igital, Smart US, Small Network/Server UPS* Pro and Personal OmniVS and VR Series (Models 1500V or Less - Standby UPS Line-Interactive UPS See p. 5 for eaturespowr PROTTION (pp. 34-35) (pp. 32-33) More Information) POWR PROTTION vailable Load apacities 300V to 300V to 500V to 1400V 1500V 1500V Surge/Noise Protection Yes Yes Yes ata Line Protection Select Select Select Models Models Models Voltage Regulation No Yes Yes xpandable Runtime No Two Models Select Models ONVNIN ompact orm actors Low-Profile Low-Profile Tower or or Tower or Tower Rack/Tower Simple Operation Yes Yes Yes RN KUP POWR igh fficiency Most Most Most Models Models Models reen Outlet Technology O-UPS No No Models OMMUNITIONS N MNMNT iagnostic Ls Most Most Select Models Models Models Status Screen Select igital () Select Models Models Models Serial and/or US Ports Most Yes Yes Models Switchable Outlet anks No No Select Models Manageable via ost Most Yes Yes omputer Models entrally Manageable Most Yes Yes Models * lthough small Network/Server UPS Systems can be ideal for important desktop applications (such as protecting critical workstations), some Network/Server UPS Systems have high-speed cooling fans that may not be suitable for low-noise environments. ontact your Tripp Lite representative for assistance if you are considering this option. 4

Network/Server UPS Systems IR PITY XTR PROTTION / IR PITY Line-Interactive On-Line ot-swappable On-Line Protection Protection Protection SmartOnline SmartPro SmartPro SmartOnline SmartOnline ot-swappable SmartOnline Tower UPS Rack/Tower UPS Tower UPS Rack/Tower UPS Rack/Tower UPS 3-Phase UPS eatures (pp. 12-13) (pp. 6-11) (pp. 20-21) (pp. 14-19) (pp. 14-19) (pp. 22-29) POWR PROTTION vailable Load apacities 750V to 500V to 750V to 750V to 5kV to 20kV to 3kV 5kV 3kV 5kV 20kV 80kV Surge/Noise Protection Yes Yes Yes Yes Yes Yes xpandable Runtime Select Models Select Models Yes Yes Yes Yes Voltage Regulation Yes Yes dvanced dvanced dvanced dvanced (±2%) (±2% or ±3%) (±3%) (±3%) Pure Sine Wave Output Select Models ll Models Yes Yes Yes Yes >500V True On-Line Operation No No Yes Yes Yes Yes RN KUP POWR igh fficiency Most Models Yes Yes Yes Yes Yes igh Power actor One Model Most Most Most Most Yes Models Models Models Models conomy Mode Operation N/ N/ Yes Yes Yes Yes I VILILITY Input Voltage Range Wide Wide Very Wide Very Wide Very Wide Very Wide Industrial Overload apacity No No No No Yes Yes utomatic ypass No One Model Yes Yes Yes Yes ot-swappable attery Yes Yes Yes Yes Yes Yes ot-swappable Power Module(s) No One Model No No Yes Yes uilt-in N+1 Redundancy No No No No N+1 Models Modular Models OMMUNITIONS N MNMNT ontrol Panel Ls Ls or Ls or Ls and/or Ls and Ls and Serial and/or US Ports Yes Yes Yes Yes Yes Yes Switchable Outlet anks Select Most Models Yes Select No No Models Models Manageable via ost omputer Yes Yes Yes Yes Yes Yes Manageable via Network ard Select Yes Yes Yes Yes Yes Models entrally Manageable Yes Yes Yes Yes Yes Yes 5

NTWORK/SRVR UPS SmartPro Line-Interactive Rack/Tower UPS Systems SmartOnline P R I esktop (Line- Interactive) esktop (Standby) SmartPro 5KV 500V T U R S & P R O R M N 500-5,000V Internal atteries and xtended Runtime Options utomatic Voltage Regulation (VR) Rack/Tower/Stack daptable onserve Space Slim as 1U! SmartPro Rackmount/Tower UPS Systems provide more battery backup (up to 5000V) and premium features in compact cases (as slim as 1U) which make the best use of available rack space. Protect very pplication SmartPro Rackmount/Tower UPS Systems are available in a wide variety of capacities to protect every size computer application from downtime, damage and data loss due to power problems. SmartPro Rackmount/Tower UPS Systems provide protection against all types of power problems, including brownouts, blackouts, surges and line noise. Line-interactive operation also known as automatic voltage regulation (VR) automatically regulates incoming voltage to keep equipment working through low voltage (brownouts) and high voltage conditions* indefinitely, without draining battery power. SmartPro Rackmount/Tower UPS Systems provide reliable battery power to keep computers up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, all outlets are backed by internal surge suppression and line noise filtering components to protect equipment from damage due to lightning and surges or malfunctions and poor performance due to line noise. * SMRT500RT1U models supply battery power during high voltage conditions. W R - W I N N I N T R I P P L I T R L I I L I T Y 6 I found Tripp Lite's product quality and customer support to be head-and-shoulders above the field. Kraft oods lane Watkins, Systems dministrator

xtend Runtime Select models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts xtending runtime is as simple as plugging in additional external battery packs. dapt to Rack/ Tower/Stack pplications dapt all models from rackmount to tower or stacking applications.* Removable rack hardware Optional base stands o to www.tripplite.com/runtime for interactive battery backup runtime charts for every UPS model. Manage Multiple Servers Multiple built-in communication ports provide the ability to simultaneously manage multiple servers without the need for accessories. Using Powerlert software, models with multiple communication ports will simultaneously provide intelligent communications, shutdown commands and reporting on multiple servers even if they are running different operating systems.* Intelligent communications allow you to check UPS status (including battery charge level) and power status as well as reboot switched outlet banks. * dditional Powerlert features: pages 30 and 31. Protect Telecom pplications Protect large telecom equipment and servers with a specially designed SmartPro Rackmount/Tower UPS System SMRT5000TL3U. The SMRT5000TL3U allows you to power and protect multiple pieces of high-voltage equipment from a single 208V circuit. In addition, the SMRT5000TL3U features two 120V outlets to support low-voltage monitors and peripherals used with high-voltage equipment. ontrol Individual Outlets Rack/Tower UPS with optional base stands. Prioritize the uptime of mission-critical loads during a power failure with switched outlet banks featured on select models. Switched outlet banks can be controlled independently through Powerlert. Use Powerlert to reboot a locked-up computer by cycling the power on and off to select outlets on the UPS system. You can also program Powerlert to shut down less important systems during an extended blackout, preserving battery runtime for critical equipment. * 1U models include hardware to adapt to tower mounting. Optional base stands (model: 2-9USTN) are available to adapt any combination of models, from 2U to 9U wide, to tower mounting. 7

eature ocus 1U SMRT1000RM1U Rear Panel 2U SMRT3000RM2U Rear Panel 3U* SMRT5000RT3U Power Module Rear Panel* * Includes 3U attery Module (not shown) to occupy a total of 6U rack space. 3U SMRT5000XMRXL Rear Panel 3U 8 SMRT5000TL3U Rear Panel

xtended Runtime apability Select models feature connectors that accept optional external battery packs for additional runtime. xternal batteries can be hot-swapped. o to www.tripplite.com/runtime for interactive runtime charts for every UPS model. Switched Outlet anks Prioritize the uptime of missioncritical loads during a power failure. Select models feature switched outlet banks that you can control independently through Powerlert software. Use Powerlert to reboot a locked-up computer or to shut down less important systems during extended blackouts, preserving battery runtime for critical equipment. ccessory ard Slot ccepts optional internal SNMPWR. SNMPWR provides network interface for monitoring and control via SNMP, Web or telnet, enabling remote reboots, shutdowns and more. Select models ( SNMP ) include a preinstalled SNMPWR. Variety of Output Options 15-, 20- and 30-amp outlets on select models ensure maximum connection flexibility. Multiple Server Support Up to four built-in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers. Short ircuit Protection reakers safeguard your equipment and the UPS. mergency Power Off (PO) jack included with all models allows remote emergency shutdown. omplete Performance onditions isplayed ront panel or Ls alert you to a variety of performance conditions, including line present, automatic voltage regulation, UPS load and replace battery. ypass Operation (not shown) SMRT3000RMO2U includes a bypass feature that allows the power module to be hot-swapped without powering down connected equipment. ront Panel attery Replacement (not shown) Most models feature a removable panel which allows for internal battery replacement.* Internal batteries can be hot-swapped. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit www.tripplite.com. Specifications U L SNMP SNMP SNMP SNMP US SNMP SNMP US Typical Total Nominal Input/ Switched Output Runtime () xtended Rack Output Voltage Outlet Outlet US Serial Input Model apacity (alf/ull Load) Runtime Size (requency 60z) Quantity (Type) anks Ports Ports Plug SmartPro UPS Systems SMRT500RT1U 500V/300W 14.6/3.2 min. 1U 120V 7 (5-15R) 1x1 1 1 5-15P SMRT750RM1U 750V/600W 4.8/16.2 min. 1U 120V 6 (5-15R) 2x1 1 1 5-15P SMRT750RMXL2U 750V/600W () 20.7/8.5+ min. 2U 120V 6 (5-15R) 2x1 1 1 5-15P SMRT1000RM1U 1000V/800W 14/4 min. 1U 120V 6 (5-15R) 2x1 1 1 5-15P SMRT1000RM2U 1000V/800W 15/5.3 min. 2U 120V 6 (5-15R) 2x1 1 1 5-15P SMRT1000RMXL2U 1000V/900W 18/6.3+ min. 2U 120V 8 (5-15R) 2x1 1 1 5-15P SMRT1500RM2U 1500V/1350W 13/4.5 min. 2U 120V 8 (5-15R) 2x1 1 1 5-15P SMRT1500RM2UN 1500V/1350W 13/4.5 min. 2U 120V 8 (5-15R) 2x1 1 1 5-15P SMRT1500RMXL2U 1500V/1350W 14/4.9+ min. 2U 120V 8 (5-15R) 2x2 1 1 5-15P SMRT1500RMXLN 1500V/1350W 14/4.9+ min. 2U 120V 8 (5-15R) 2x2 1 1 5-15P SMRT2200RM2U 2200V/1920W 12/4.5 min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x1 1 1 5-20P SMRT2200RM2UN 2200V/1920W 12/4.5 min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x1 1 1 5-20P SMRT2200RMXL2U 2200V/1920W () 12/4.5+ min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x1 1 1 5-20P SMRT2200RMXL2UP 2200V/1920W 12/4.5+ min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x1 1 1 5-20P SMRT2200RMXLN 2200V/1920W () 12/4.5+ min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x1 1 1 5-20P SMRT2600RM2U 2600V/2100W (,) 11/4+ min. 2U 120V 4 (5-15R), 4 (5-15/20R), 3x1 1 1 5-20P 1 (L5-20R) SMRT3000RM2U 3000V/2250W () 10/3.5+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT3000RM2UN 3000V/2250W () 10/3.5+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT3000RMO2U 3000V/2880W () 11/4+ min. 2U 110/120/127V 6 (5-15R), 1 (L5-30R) 1x2, 1x4 1 1 L5-30P (50/60z) SMRT3000RMXL2U 3000V/2880W 10/3+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT3000RMXLN 3000V/2880W 10/3+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT5000RT3U 5000V/4000W () 38/16+ min. 6U 208V in; 208V + 10 (5-15R), 2 (5-15/20R), 120V out 1 (L6-30R), 1 (L14-30R) 8x1 2 2 L6-30P SMRT5000XMRXL 5000V/3750W () 20/8.5+ min. 3U 208V in; 208V + 8 (5-15/20R), 2 (L6-20R), 8x1 1 2 () L6-30P 120V out 1 (L6-30R) SMRT5000TL3U 5000V/3750W () 20/8.5 min. 3U 208V in; 208V + 2 (5-15R), 2 (L6-20R), 1 2 () L6-30P 120V (600V) out 1 (L6-30R) Model with hot-swappable power module. Model with expandable runtime. Model with. SNMP Model with pre-installed SNMPWR. xternal attery Packs and ccessories P24V28-2U 24V external battery pack and cable, 2U. Not expandable. R/LK 2-point connector. P24V70-3U 24V external battery pack and cable, 3U. xpandable. R/LK 2-point connector. P36V15-2U 36V external battery pack and cable, 2U. Not expandable. RY 2-point connector. P36V42-3U 36V external battery pack and cable, 3U. xpandable. RY 2-point connector. P48V24-2U 48V external battery pack and cable, 2U. Not expandable. LU 2-point connector. P48V60RT-3U 48V external battery pack and cable, 3U. xpandable. LU 2-point connector. P72V15-2U 72V external battery pack and cable, 2U. Not expandable. LK 3-point connector. P72V28RT-3U 72V external battery pack and cable, 3U. xpandable. LK 3-point connector. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. 2-9USTN dapts UPS modules and battery packs for tower installation. One kit adjusts from 2U to 9U. Two kits adjust from 10U to 14U. 2POSTRMKIT eavy-duty 2-post rack mounting kit for 2U to 4U UPS modules and battery packs. Order one kit per module or battery pack. ertifications vary by model. ll models include an accessory card slot, 10 ft. input cord and mounting hardware for installation in standard 19 in. 4-post racks. 1U models also support 2-post rack installation. 2U and larger models require optional 2-post mounting hardware for 2-post rack installation. () onnecting an external battery pack reduces maximum output. See tripplite.com for more information. () Maximum output requires a user-supplied plug. See tripplite.com for more information. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. () Includes an RS-232 serial port and a contact-closure port. Visit www.tripplite.com/smartpro for the latest specifications, including weights and dimensions. 9

NTWORK/SRVR UPS SmartPro Shallow-epth Line-Interactive Rack UPS Systems SmartOnline P R I esktop (Line- Interactive) esktop (Standby) SmartPro 3.6KV 1.5KV T U R S & P R O R M N 1,500-3,600V est-in-lass Mounting epth utomatic Voltage Regulation (VR) Optional xternal attery Packs for xtended Runtime Support Network/Telecom Wiring losets Shallow mounting depth matches popular network/telecom equipment and allows UPS systems to fit in confined spaces. igh load capacity and internal battery capacity allow you to attach more equipment safely without installing additional circuits and UPS systems. Shallow-depth SMRT3000RMXL, SMRT2200RMXL and the matching P48V48RT4U external battery pack include all hardware required for secure mounting in 2-post network/telecom racks. ombine with Tripp Lite s SR2POST or SR2POST25 2-post racks to create ideal solutions for organizing, protecting and powering important equipment in cramped network/telecom wiring closets. xtend Runtime Protect Sensitive quipment Line-interactive operation also known as automatic voltage regulation (VR) automatically adjusts incoming voltage to safe levels without draining battery power. Reliable battery backup keeps equipment operating through power failures. Pure sine wave output guarantees maximum stability and compatibility with sensitive equipment. ll outlets include network-grade surge suppression and noise filtering. xtended Runtime harts ll models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. Lower Operating osts -to- efficiency up to 97% reduces power consumption and lowers operating costs. ach two watts saved by increased UPS efficiency saves an additional watt in cooling requirements. igher efficiency also lowers your facility s environmental impact. o to www.tripplite.com/runtime for interactive battery backup runtime charts for every UPS model. 10 2

eature ocus K K J J I SMRT1500RMXL Rear Panel K SMRT3000RMXL/SMRT2200RMXL Rear Panel xternal attery Pack onnector onnects to an external battery pack for extended battery backup runtime. xpandable battery packs can be daisy-chained for additional runtime expansion. ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to control and monitor alarms and security systems. RLYIOR provides a programmable contact closure interface with 6 outputs and 1 input. mergency Power Off (PO) Jack onnects to facility s emergency power off switch for emergency shutdown of the UPS system. I-ompliant US Port and RS-232 Serial Port (9) onnects to a computer s US or serial port for automatic shutdown during extended power failures. Use with Powerlert software* or the built-in power management utilities of Mac OS X, Linux and Windows. Powerlert -ROM and cabling are included. I 5-15R Outlets Select outlets can be switched on or off remotely through Powerlert software or SNMPWR, enabling connected equipment reboot or shutdown. 5-15/20R Outlets These 20-amp outlets accommodate 5-15P or 5-20P plugs. Select outlets can be switched on or off remotely through Powerlert software or SNMPWR, enabling connected equipment reboot or shutdown. L5-30R Outlet (SMRT3000RMXL only) This 30-amp outlet connects to an L5-30P twist-lock plug. harge Rate Switch Sets battery charger to higher or lower amperage. Increasing the amperage allows the UPS system to recharge batteries more rapidly when external battery packs are connected. ypass larm Switch nables or disables bypass alarm. In case of internal fault or battery depletion, the bypass routes power to the outlets. J Input reaker K Output reakers (SMRT3000RMXL only) Internal attery Replacement (not shown) Recyclable internal batteries last several years under normal conditions. removable front panel allows hot-swappable internal battery replacement* asy-to-read ontrol Panel ront panel Ls display a variety of power conditions, including line status, automatic voltage regulation, overload, on battery, check battery and more. Real-time updates allow you to respond to power problems before your equipment is placed at risk. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit www.tripplite.com. * dditional Powerlert features: pages 30 and 31. Specifications US Nominal Input/ Switched Primary Output Typical Runtime () Output Voltage Outlet Outlet omm. Mounting Model apacity (alf/ull Load) (requency 60z) Quantity (Type) anks Ports Plug Type Option SMRT1500RMXL 1500V/1440W 14/6+ min. 120V 8 (5-15R) 3x1 RS-232, 5-15P 4-Post US, PO Rack (2U) SMRT2200RMXL 2200V/1900W 28/11+ min. 120V 4 (5-15R), 3x1 RS-232, 5-20P 2-Post 4 (5-15/20R) US, PO Rack (4U) SMRT3000RMXL 3000V/2880W (3600V/3600W 19/7.5+ min. () 120V 8 (5-15/20R), 3x1 RS-232, L5-30P 2-Post via optional hardwire) () 1 (L5-30R) US, PO (optional hardwire) Rack (4U) xternal attery Packs (ompatible with all RM models.) P48V48RT4U P48V24-2U P48V60RT-3U xpandable 4U battery pack optimized for SMRT3000RMXL and SMRT2200RMXL. Includes 2-post mounting hardware. Non-expandable 2U battery pack optimized for SMRT1500RMXL. Includes 4-post mounting hardware. xpandable 3U battery pack. Includes 4-post mounting hardware. ccessories SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. 2-9USTN dapts UPS modules and battery packs for tower installation. One kit adjusts from 2U to 9U. Two kits adjust from 10U to 14U. 2POSTRMKIT eavy-duty 2-post rack mounting kit for 2U to 4U UPS modules and battery packs. Order one kit per module or battery pack. 4POSTRILKIT Mounting kit for 4-post rackmount installation. Order one kit per module or battery pack. Model with expandable runtime. ertifications vary by model. ll models include an accessory card slot and 10 ft. input cord. () Included cord and plug can be removed to permit hardwire input for 3600V/3600W output capacity. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. () Typical runtime is 13/5 min. for optional hardwire input. Visit www.tripplite.com/smartpro for the latest specifications, including weights and dimensions. 11

NTWORK/SRVR UPS SmartPro Line-Interactive Tower UPS Systems esktop (Standby) esktop (Line- Interactive) 3KV 750V Protect very pplication SmartPro Tower UPS Systems are available in a wide variety of capacities to protect every size computer application from downtime, damage and data loss due to power problems. SmartPro Tower UPS Systems provide protection against all types of power problems, including brownouts, blackouts, surges and line noise. Line-interactive operation also known as automatic voltage regulation (VR) keeps equipment working through low voltage (brownouts) and high voltage conditions indefinitely, without draining battery power. SmartPro Tower UPS Systems provide reliable battery power to keep computers up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, all outlets stop damaging surges and filter disruptive line noise. ontrol Individual Outlets 750-3,000V Internal atteries and xtended Runtime Options utomatic Voltage Regulation (VR) xtend Runtime Select models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts Prioritize the uptime of mission-critical loads during a power failure with switched outlet banks featured on select models. Use Powerlert to reboot a locked-up computer by cycling the power on and off to select outlets on the UPS system. You can also program Powerlert to shut down less important systems during an extended blackout, preserving battery runtime for critical equipment. Manage Multiple Servers Multiple built-in communication ports provide the ability to simultaneously manage multiple servers without the need for accessories. Using Powerlert software, select models with multiple communication ports will simultaneously provide intelligent communications, shutdown commands and reporting on multiple servers even if they are running different operating systems.* o to www.tripplite.com/runtime for interactive battery backup runtime charts for every UPS model. * dditional Powerlert features: pages 30 and 31. 12 2

eature ocus xtended Runtime apability Select models feature connectors that accept optional external battery packs for additional runtime. xternal batteries can be hot-swapped. o to www.tripplite.com/runtime for interactive runtime charts for every UPS model. Switched Outlet anks Prioritize the uptime of mission-critical loads during a power failure. Select models feature switched outlet banks that you can control independently through Powerlert software. Use Powerlert to shut down less important systems first, preserving battery runtime for critical equipment. Multiple Server ontrol Up to four built-in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers without the need for accessories. Variety of Output Options 15-20- and 30-amp outlets ensure maximum connection flexibility. mergency Power Off (PO) jack on select models allows remote emergency shutdown. Tel/SL/thernet Surge Protection (select models, not shown) Protect Internet-connected or networked computers from damage on a single telephone or thernet line. SMRT3000VS Rear Panel ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to control and monitor alarms. RLYIOR provides programmable contact closure interface with 6 outputs and 1 input. attery Replacement Tripp Lite UPS batteries will protect equipment for several years with normal use. Most models feature a removable panel which allows for internal battery replacement*. Internal batteries can be hot-swapped. Short ircuit Protection Performance onditions isplayed ront panel Ls alert you to a variety of performance conditions, including line present, automatic voltage regulation, UPS load level and replace battery. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit www.tripplite.com. Specifications US U L Typical Nominal Switched US Output Runtime () xtended Input/Output Voltage Outlet Outlet US Serial SNMP Input Model apacity (alf/ull Load) Runtime (requency 60z) Quantity (Type) anks Ports Ports Slot Plug SmartPro UPS Systems SMRT750 750V/450W 16.2/5.6 min. 120V 6 (5-15R) 1 5-15P SMRT700SR 700V/450W 16.9/5.9 min. 120V 6 (5-15R) 1 5-15P SMRT700V 700V/450W 54.5/22.2 min. 120V or 230V in; 120V out 6 (5-15R) 1 1 Y 5-15P (14) SMRT750XL 750V/500W 20.7/10+ min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT750SLT 750V/500W 17.8/6.5 min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT1050 1050V/705W 23/8 min. 120V 6 (5-15R) 1 5-15P SMRT1050SLT 1050V/650W 19/7 min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT1500 1500V/980W 20/7 min. 120V 6 (5-15R) 1x1 1 1 5-15P SMRT1500SLT 1500V/900W 20/8 min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT1500XL 1500V/980W 20/7+ min. 120V 6 (5-15R) 1x1 1 1 5-15P SMRT2200VS 2200V/1600W 19/7 min. 120V 7 (5-15R), 2 (5-15/20R) 3x2 2 2 Y 5-20P SMRT2200SLT 2200V/1600W 13/5 min. 120V 6 (5-15/20R), 1 (L5-20R) 1 1 Y 5-20P SMRT2200VSXL 2200V/1600W 19/7+ min. 120V 7 (5-15R), 2 (5-15/20R), 1 (L5-20R) 3x1 2 2 Y 5-20P SMRT2200NT 2200V/1700W 27/11+ min. 120V 6 (5-15R) 2x1 3 () 5-15P SMRT3000VS 3000V/2250W 14/4+ min. 120V 7 (5-15R), 2 (5-15/20R), 1 (L5-30R) 3x2 2 2 Y L5-30P SMRT3000NT 3000V/2400W 23/7+ min. 120V 4 (5-15R), 4 (5-15/20R) 2x1 3 () L5-30P SMRT3000SLT 3000V/2250W 9/3.5 min. 120V 6 (5-15/20R), 1 (L5-30R) 1 1 Y L5-30P xternal attery Packs and ccessories P24V28-2U 24V external battery pack and cable, 2U. Not expandable. R/LK 2-point connector. P24V70-3U 24V external battery pack and cable, 3U. xpandable. R/LK 2-point connector. P36V15-2U 36V external battery pack and cable, 2U. Not expandable. RY 2-point connector. P36V42-3U 36V external battery pack and cable, 3U. xpandable. RY 2-point connector. P48V24-2U 48V external battery pack and cable, 2U. Not expandable. LU 2-point connector. P48V60RT-3U 48V external battery pack and cable, 3U. xpandable. LU 2-point connector. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. Model with expandable runtime. ertifications vary by model. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. () Includes an RS-232 serial port and two contact-closure ports. Visit www.tripplite.com/smartpro for the latest specifications, including weights and dimensions. 13

RKMOUNT/TOWR UPS NTWORK/SRVR UPS SmartOnline True On-Line Rack/Tower UPS Systems SmartOnline P R I esktop (Standby) esktop (Line- Interactive) SmartPro 20KV 750V T U R S & P R O R M N 14 2 eliver True On-Line, Pure Sine Wave, Zero Transfer Time Operation SmartOnline Rackmount/Tower UPS Systems provide mission-critical equipment with the highest level of power protection. oubleconversion technology continually converts incoming power into filtered power, and then resynthesizes it back into power with a pure sine wave. onstant on-line operation completely isolates sensitive equipment from every power problem on the line. SmartOnline models accept the widest range of incoming voltage and frequency variations, delivering the most consistently pure, highly regulated power: ±3% or ±2% V. SmartOnline Rackmount/Tower UPS Systems provide reliable battery power with zero transfer time to keep networks up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, they stop damaging surges and filter disruptive line noise. TRU ON-LIN 750V - 20kV Zero Transfer Time, ouble onversion Wide Input Voltage Range with Precision-Regulated Output xtended Runtime Options utomatic Internal ypass Maintenance ypass and etachable PU Options Manage Multiple Servers Using Powerlert software, select models with multiple communication ports will simultaneously provide intelligent communications, shutdown commands and reporting on multiple servers even if they are running different operating systems.* Intelligent communications allow you to check UPS status (including battery charge level and runtime remaining) and power status as well as reboot switched outlet banks. * dditional Powerlert features: pages 30 and 31. ontrol Individual Outlets Switched outlet banks on select models can be controlled independently through Powerlert. Use Powerlert to reboot a locked-up computer by cycling the power on and off to select outlets on the UPS system. You can also program Powerlert to shut down less important systems during an extended blackout, preserving battery runtime for critical equipment. Save lectricity & Reduce osts SmartOnline UPS Systems are up to 97% efficient in economy mode, a potential increase of 10% or more versus comparable on-line UPS systems. conomy mode can make your data center significantly cooler, greener and more cost-effective.

Provide Maximum vailability with ot-swappable esign ot-swap the Power Module...... etachable PU ontinues Powering quipment ll SmartOnline Rackmount/Tower UPS Systems include an automatic internal bypass that ensures maximum availability of connected equipment by passing through utility power in the event of an internal fault or overload. ot-swappable models include two additional features that ensure continuous availability: a maintenance bypass switch and a modular design. When the switch is set to bypass, the power module can be removed for maintenance while the detachable PU remains installed, continuing to power connected equipment as long as utility power is present. ot-swappable models are designated by the symbol in the specifications chart. Select hot-swappable models (designated by the N+1 symbol) include dual power modules for built-in N+1 redundancy. dapt to Rack / Tower / Stack pplications dapt all models from rackmount to tower or stacking applications. Removable rack hardware Optional tower base stands (2-9USTN) isplay Power onditions ront-panel Ls and/or help you identify power problems and solutions. Single cabinet tower mount with optional base stands. Multiple cabinet tower mount with optional base stands. xtended Runtime harts xtend Runtime ll models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtending runtime is as simple as plugging in additional external battery packs. o to www.tripplite.com/runtime for interactive battery backup runtime charts for every UPS model. 15

eature ocus xtended Runtime apability ll models feature connectors that accept optional external battery packs for additional runtime. xternal batteries can be hot-swapped. o to www.tripplite.com/runtime for interactive runtime charts for every UPS model. etachable ypass PU Passes through power to connected equipment if power module is removed for maintenance. Switched Outlet anks Select models feature switched outlet banks that you can control independently through Powerlert software. Server Support Up to two built-in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers without the need for accessories. ypass Operation bypass switch allows the power module to be removed for maintenance, repair or replacement while continuously passing through utility power to connected equipment. ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to monitor alarms and security systems. RLYIOR provides a programmable contact closure interface with 6 outputs and 1 input. Short ircuit Protection ircuit breakers help guard against input/output short circuits and overloads. mergency Power Off jack included with select models allows remote emergency shutdown. ll other models can perform emergency shutdown by attaching an optional cable (model 730909, sold separately) to the communication port. The optional cable includes a 9 connector to allow server support and a jack to allow emergency shutdown. Standard Models Maximum vailability eatures: Internal ypass ot-swappable atteries SU2200RTXL2U UPS System Rear Panel with Internal atteries. 2U K J SU3000RTXL3U/ SU3000RTXR3U UPS System Rear Panel with Internal atteries. 3U K J K SU5000RT3U UPS System Rear Panel with Isolation Transformer and xternal attery Pack. 3U 7U Total 2U K 2U 16

I J ardwire, Single-Phase Input (select models) To convert select models to hardwire input and output, select optional hardwire input/output PUs. To add an input plug and outlets to SU6000RT3U and SU6000RT3UV select SUPM alternate back panel accessories. TL/SL/thernet Surge Protection (select models) Protect Internet-connected or networked computers from damage on a single telephone or thernet line with surge-protected jacks featured on select models. K Variety of Output Options 15-, 20- and 30-amp outlets on select models ensure maximum connection flexibility. ront Panel attery Replacement (not shown) 1,000 to 3,000V models feature a convenient front access door to replace internal batteries.* ll models allow hot-swap battery replacement. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit www.tripplite.com. ot-swappable Modular Models Maximum vailability eatures: Internal ypass ypass Switch ot-swappable Power Module ot-swappable atteries 4U SU6000RT4U UPS System Rear Panel with Internal atteries. K K I 6U Total 3U SU10000RT3U UPS System Rear Panel with xternal attery Pack. Multiple PU options available. 3U K 2U SU5000XMRT2U Isolation Transformer Rear Panel. K SU16000RT4U UPS System Rear Panel with xternal attery Pack. 4U 8U Total 4U I K K 17

Total US Specifications U L US Input Outlet Output Typical Runtime () xtended Rack Voltage Nominal Quantity (Type) US Serial () Input Model apacity (alf/ull Load) Runtime Size Range () Output Voltage [Switched Outlet anks] Ports Ports Ports Plug SmartOnline Single-Phase UPS Systems (3-wire input) SU750RTXL2U 750V/600W 11/4+ min. 2U 65-150V 120V (100/ 6 (5-15R); [2x1] 1 1 () 5-15P 110/120V) SU750RTX2U 750V/675W 9/3+ min. 2U 55-150V 120V (100/110/115 6 (5-15R); [2x1] 1 1 () 5-15P 120/127V) SU1000RTXL2U 1000V/800W 14/4.5+ min. 2U 65-150V 120V (100/110/120V) 6 (5-15R); [2x1] 1 1 () 5-15P SU1000RTX2U 1000V/900W 14/4.8+ min. 2U 55-150V 120V (100/110/115 6 (5-15R); [2x1] 1 1 () 5-15P 120/127V) SU1500RTXL2U 1500V/1200W 14/5+ min. 2U 65-150V 120V (100/110/120V) 6 (5-15R); [1x2, 1x4] 1 1 () 5-15P SU1500RTX2U 1500V/1350W 14/4.2+ min. 2U 55-150V 120V (100/110/115 6 (5-15R); [2x3] 1 1 () 5-15P 120/127V) SU2200RTXL2U 2200V/1600W 14/4.5+ min. 2U 65-150V 120V (110/120V) 6 (5-15/20R); 1 1 () 5-20P 1 (L5-20R); [2x3] SU2200RTX2U 2200V/1800W 12/4+ min. 2U 55-150V 120V (100/110/115 6 (5-15/20R); 1 1 () 5-20P 120/127V) 1 (L5-20R); [2x3] SU3000RTXL2U 3000V/2500W 15/6+ min. 2U 60-144V 120V (100/110/115 6 (5-15/20R), 1 1 () L5-30P 120/127V) 1 (L5-30R); [2x3] SU3000RTXL3U 3000V/2400W 14/5+ min. 3U 65-150V 120V (110/120V) 4 (5-15R), 4 (5-15/20R), 1 1 () L5-30P 1 (L5-30R); [2x4] SU3000RTXL3UV 3000V/2400W 14/5+ min. 3U 160-275V 208/240V 6 (6-15/20R), 1 () L6-20P 2 (L6-20R); [1x2, 1x4] SU3000RTX3U 3000V/2700W 11/4+ min. 3U 55-150V 120V (100/110/115 4 (5-15R), 4 (5-15/20R), 1 1 () L5-30P 120/127V) 1 (L5-30R); [2x4] SU3000RTXR3U 3000V/2400W 30/12+ min. 3U 65-150V 120V (110/120V) 4 (5-15R), 4 (5-15/20R), 1 1 () L5-30P 1 (L5-30R); [2x4] SU3000RTXR3UW 3000V/2400W 30/12+ min. 3U 65-150V 120V (110/120V) ardwire 1 1 () ardwire SU5000RT3U 5kV/3.5kW 20/8+ min. I 7U 156-276V 208V + 120V (60z) 2 (L6-20R), 2 (L6-30R), 1 1 L6-30P 12 ( 5-15/20R) SU5000RT3UV 5kV/3.5kW 20/8+ min. I 5U 156-276V 208/240V 2 (L6-20R), 2 (L6-30R) 1 1 L6-30P SU5000RT4UV 5kV/4.5kW 11/3.5+ min. 4U 100-300V 208/240V 2 (L6-20R), 2 (L6-30R) 1 1 L6-30P SU5000RT4UT 5kV/4.5kW 11/3.5+ min. 6U 100-300V 208V + 120V (60z) 2 (L6-20R), 2 (L6-30R), 1 1 L6-30P 12 (5-15/20R) SU6000RT3U 6kV/4.2kW 20/8+ min. I 9U 156-276V 208/240V + 120V ardwire () 1 1 ardwire () SU6000RT3UV 6kV/4.2kW 20/8+ min. I 6U 156-276V 208/240V ardwire () 1 1 ardwire () SU6000RT3UVXL 6kV/4.2kW 30/12+ min. I 6U 156-276V 208/240V ardwire 1 1 ardwire SU6000RT4UV 6kV/5.4kW 8.5/2+ min. 4U 100-300V 208/240V 2 (L6-20R), 2 (L6-30R) 1 1 L6-30P SU6000RT4UV 6kV/5.4kW 8.5/2+ min. 4U 100-300V 208/240V 4 (19) 1 1 ardwire SU6000RT4UVW 6kV/5.4kW 8.5/2+ min. 4U 100-300V 208/240V ardwire 1 1 ardwire SU6000RT4UT 6kV/5.4kW 8.5/2+ min. 6U 100-300V 208/240V + 120V 2 (L6-20R), 2 (L6-30R), 1 1 L6-30P 4 (5-15R), 8 (5-15/20R), ardwire SU6000RT4UTW 6kV/5.4kW 8.5/2+ min. 6U 100-300V 208/240V + 120V 2 (L6-20R), 2 (L6-30R), 1 1 ardwire 4 (5-15R), 8 (5-15/20R), ardwire SU8000RT3U 8kV/7.2kW 13.5/5.5+ min. I 6U 100-300V 208/240V 4 (L6-20R), 2 (L6-30R) 1 1 ardwire SU8000RT3U1T 8kV/7.2kW 13.5/5.5+ min. I 8U 100-300V 208V + 120V (60z) 4 (L6-20R), 2 (L6-30R), 1 1 ardwire 12 (5-15/20R) SU8000RT3U 8kV/7.2kW 13.5/5.5+ min. I 6U 100-300V 208/240V 6 (19) 1 1 ardwire SU8000RT3UW 8kV/7.2kW 13.5/5.5+ min. I 6U 100-300V 208/240V ardwire 1 1 ardwire SU8000RT3UN50 8kV/7.2kW 13.5/5.5+ min. I 6U 100-300V 208/240V 4 (L6-20R), 2 (L6-30R) 1 1 S8265 () SU8000RT3UN50T 8kV/7.2kW 13.5/5.5+ min. I 8U 100-300V 208V + 120V (60z) 4 (L6-20R), 2 (L6-30R), 1 1 S8265 () 12 (5-15/20R) SU10KRT3U 10kV/9kW 12.5/4.3+ min. I 9U 100-300V 208/240V + 120V ardwire 1 1 ardwire SU10KRT3UV 10kV/9kW 12.5/4.3+ min. I 6U 100-300V 208/240V ardwire 1 1 ardwire SU10000RT3U 10kV/9kW 12.5/4.3+ min. I 6U 100-300V 208/240V 4 (L6-20R), 2 (L6-30R) 1 1 ardwire SU10000RT3U2T 10kV/9kW 12.5/4.3+ min. I 10U 100-300V 208V + 120V (60z) 4 (L6-20R), 2 (L6-30R), 1 1 ardwire 24 (5-15/20R) SU10000RT3U 10kV/9kW 12.5/4.3+ min. I 6U 100-300V 208/240V 6 (19) 1 1 ardwire Model with hot-swappable power module(s). Model with. Model with expandable runtime. 18

Total US Specifications N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 U L US Input Output Typical Runtime xtended Rack Voltage Nominal Outlet US Serial () Input Model apacity (alf/ull Load) Runtime Size Range () Output Voltage Quantity (Type) Ports Ports Ports Plug SmartOnline Single-Phase UPS Systems (3-wire input) with ual Power Modules and uilt-in N+1 Redundancy (N+1 if load is 50% or less) SU12KRT4UW 12kV/10.8kW 8.5/2+ min. 8U 100-300V 208/240V ardwire 2 2 ardwire SU16KRT 16kV/14.4kW 13.5/5.5+ min. I 12U 100-300V 208/240V 2 (L6-30R), 8 (19) 2 2 ardwire SU16KRT-1T 16kV/14.4kW 13.5/5.5+ min. I 14U 100-300V 208/240V + 120V 2 (L6-30R), 8 (19), 2 2 ardwire 8 (5-15/20R), 4 (5-15R) SU16KRT8 16kV/14.4kW 13.5/5.5+ min. I 12U 100-300V 208/240V 8 (L6-20R), 2 (L6-30R) 2 2 ardwire SU16KRT 16kV/14.4kW 13.5/5.5+ min. I 12U 100-300V 208/240V 8 (19) 2 2 ardwire SU16KRTW 16kV/14.4kW 13.5/5.5+ min. I 12U 100-300V 208/240V ardwire 2 2 ardwire SU20KRT 20kV/18kW 12.5/4.3+ min. I 12U 100-300V 208/240V 2 (L6-30R), 8 (19) 2 2 ardwire SU20KRT-1T 20kV/18kW 12.5/4.3+ min. I 14U 100-300V 208/240V + 120V 2 (L6-30R), 8 (19), 2 2 ardwire 8 (5-15/20R), 4 (5-15R) SU20KRT8 20kV/18kW 12.5/4.3+ min. I 12U 100-300V 208/240V 8 (L6-20R), 2 (L6-30R) 2 2 ardwire SU20KRT 20kV/18kW 12.5/4.3+ min. I 12U 100-300V 208/240V 8 (19) 2 2 ardwire SU20KRTW 20kV/18kW 12.5/4.3+ min. I 12U 100-300V 208/240V ardwire 2 2 ardwire SmartOnline Split-Phase UPS Systems (4-wire input) SU5000RT4U 5kV/3.8kW 14/6+ min. 4U 65-140V (L-N) 208/240V + 120V 8 (5-15/20R), 1 1 () L14-30P 2 (L6-20R), 2 (L6-30R) SU6000RT4U 6kV/4.2kW 20/8+ min. 4U 65-140V (L-N) 208/240V + 120V 8 (5-15/20R), 1 1 () L14-30P 2 (L6-20R), 2 (L6-30R) SU8000RT4U 8kV/5.6kW 12/5+ min. 4U 65-140V (L-N) 208/240V + 120V 4 (5-15/20R), 2 (L6-20R), 1 1 () ardwire 2 (L6-30R), ardwire SU12000RT4U 12kV/8.4kW 20/7+ min. 8U 65-140V (L-N) 208/240V + 120V 5 (5-15/20R), 2 (L6-30R), 1 1 () ardwire 6 (19), ardwire SU12000RT4UW 12kV/8.4kW 20/7+ min. 8U 65-140V (L-N) 208/240V + 120V ardwire 1 1 () ardwire SU16000RT4U 16kV/11.2kW 12/5+ min. 8U 65-140V (L-N) 208/240V + 120V 5 (5-15/20R), 2 (L6-30R), 1 1 () ardwire 6 (19), ardwire SU16000RT4UW 16kV/11.2kW 12/5+ min. 8U 65-140V (L-N) 208/240V + 120V ardwire 1 1 () ardwire N+1 Model with built-in N+1 redundancy. Model with hot-swappable power module(s). Model with. Model with expandable runtime. Model escription xternal attery Packs and ccessories P24V28-2U 24V external battery pack and cable, 2U. Not expandable. R/LK 2-point connector. P24V70-3U 24V external battery pack and cable, 3U. xpandable. R/LK 2-point connector. P48V24-2U 48V external battery pack and cable, 2U. Not expandable. LU 2-point connector. P48V60RT-3U 48V external battery pack and cable, 3U. xpandable. LU 2-point connector. P72V15-2U 72V external battery pack and cable, 2U. Not expandable. LK 3-point connector. P72V28RT-3U 72V external battery pack and cable, 3U. xpandable. LK 3-point connector. P192V12-3U 192V external battery pack and cable, 3U. xpandable. LK 3-point connector. P192V18-4U 192V external battery pack and cable, 4U. xpandable. YLLOW INSULT 2-point connector. I P240V10RT3U 240V external battery pack and cable, 3U. xpandable. LK 3-point connector. SU5000XMRT2U 5kV transformer. 208V input. 208V+120V output. L6-30P input. 12 (5-15/20R)+1 (L6-30R) outlets. SU6000XMR2U 6kV transformer. 208/240V input. 208/240V+120V output. L6-30P or hardwire input. 4 (5-15R)+8 (5-15/20R)+1 (L6-30R) outlets + hardwire. 2-9USTN dapts UPS modules and battery packs for tower installation. One kit adjusts from 2U to 9U. Two kits adjust from 10U to 14U. 2POSTRMKIT eavy-duty 2-post rack mounting kit for 2U to 4U UPS modules and battery packs. Order one kit per module or battery pack. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. MOUSR dds interface for MOUS RTU industrial communications protocol, RS-422/485 and RS-232 to compatible UPS systems. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. RLYIOMINI dds contact-closure port (9) to compatible single-phase 8-20kV UPS systems. Replaces US port. SUPM568W etachable PU for SU5000RT4U, SU6000RT4U and SU8000RT4U. ardwire input and output. Includes bypass switch. ertifications vary by model. ll models include an accessory card slot and mounting hardware for installation in standard 19 in. 4-post racks. 1U models also support 2-post rack installation. 2U and larger models require optional 2-post mounting hardware for 2-post rack installation. () Runtime varies with load, battery condition and other factors. Runtimes are expandable using optional external battery packs. () requency is 50/60z for single-phase models and 60z for split-phase models unless noted. Input voltage range varies withload. Maximum range shown. () Includes a combination RS-232 serial and contact-closure port. () Optional kits convert hardwire input/output to corded input and outlets. () ontact-closure ports () 50 ubbell S8265. lso supports hardwire input. Visit www.tripplite.com/smartonline for the latest specifications, including weights and dimensions. 19

NTWORK/SRVR UPS SmartOnline True On-Line Tower UPS Systems SmartOnline P R I esktop (Standby) esktop (Line- Interactive) SmartPro 3KV 750V T U R S & P R O R M N eliver True On-Line, Pure Sine Wave, Zero Transfer Time Operation SmartOnline Tower UPS Systems provide mission-critical equipment with the highest level of power protection. ouble-conversion technology continually converts incoming power into filtered power, and then resynthesizes it back into power with a pure sine wave. onstant on-line operation completely isolates sensitive equipment from every power problem on the line. SmartOnline models accept the widest range of incoming voltage and frequency variations, delivering the most consistently pure, highly-regulated power: ±3% or ±2% V and ±0.05 z. SmartOnline Tower UPS Systems provide reliable battery power with zero transfer time to keep networks up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, they stop damaging surges and filter disruptive line noise. ll models ensure maximum availability with an automatic internal bypass which passes through utility power in the event of an internal fault or overload. Manage Multiple Servers Using Powerlert software, simultaneously manage multiple servers even if they are running different operating systems.* Intelligent communications allow you to check UPS status (including battery charge level and runtime remaining) and power status. You can use Powerlert to reboot a locked-up server by cycling the power to select UPS outlets or shut down nonessential systems during a blackout, preserving runtime for critical equipment. * dditional Powerlert features: pages 30 and 31. TRU ON-LIN 750-3,000V Zero Transfer Time, ouble onversion Wide Input Voltage Range with Precision-Regulated Output utomatic Internal ypass Internal atteries and xtended Runtime Options xtend Runtime ll models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts 20 Save lectricity & Reduce osts SmartOnline UPS Systems are up to 97% efficient in economy mode, a potential increase of 10% or more versus comparable on-line UPS systems. conomy mode can make your data center significantly cooler, greener and more cost-effective. o to www.tripplite.com/runtime for interactive battery backup runtime charts for every UPS model.