Technical specifications. Containerized data centre NTR CDC 40f+



Similar documents
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Automation's Modular Containerized Datacenter Solutions

DATACENTER COLOCATION. Flexible, Secure and Connected

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

RiMatrix S Make easy.

LEVEL 3 DATA CENTER ASSESSMENT

Colocation. Introduction. Structure of the service. Service Description

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Our Hosting Infrastructure. An introduction to our Platform, Data Centres and Data Security.

Portable Energy Efficient Data Centre Solution

IPSIP M series-m Modular Data Center

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Scalable. Affordable. Flexible. Fast.

JAWAHARLAL NEHRU UNIVERSITY

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

19 Site Location, Design and Attributes. Site Location, Design and Attributes

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Modular Datacenter based in a 20' container

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

Standardised Data centres. Sales presentation

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

As close to perfection. development and production. Modular data center

Previder Datacenters it starts here

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

BELLE VUE MANCHESTER DATA CENTRE

Phase Modular Finally the benefits of Modular ups are for all

Data Center Infrastructure & Managed Services Outline

2 Rittal Micro Data Centre

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

Product description NCC Data Center

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Data Center Presentation

Data Centre Services. JT Rue Des Pres Data Centre Facility Product Description

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

World s Greenest High Performance Data Center

Georgia Tech Aerospace Server French building Server Room. Server Room Policy Handbook: Scope, Processes and Procedure

Technical requirements

Case study; A sustainable Green Data Centre, fact or fiction?

Data Centre Solutions energy efficient by design

White Paper Data Centre in a Standard Container

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

melbourne//australia data center specifications internet + intellectual property + intelligence tel: fax:

IBM Portable Modular Data Center Overview for Critical Facilities Round Table

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

DATACENTER ZURICH. Well Positioned for Security

Datacentre South London Data sheet

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

The Mission Critical Data Center Understand Complexity Improve Performance

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Netmagic Vikhroli Datacenter Infrastructure & Capabilities

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Huawei IDS2000 Modular Data Center Solution

University of St Andrews. Energy Efficient Data Centre Cooling

CyberSafe has expanded to three companies in United Arab Emirates, Kingdom of Bahrain & India within a Short Span of Time.

Data Center CH1. Elk Grove Village, IL

Current as of 11/10/08 1 of 1

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering % uptime

Data Center Components Overview

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

GREEN DATA CENTER DESIGN

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Product Overview. Swaminathan.S Business Development Manager

Datacentre South Gyle 1 Data sheet

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Wireless Networks and Power Quality

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Europe s greenest data center

Experience Matters...

Datacenter Assessment

Data Centre Testing and Commissioning

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

Introducing UNSW s R1 Data Centre

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

CRAC Precision climate control units for data centres

Intelligent Power Distribution in the Data Center

Eaton 93PM UPS Where aesthetics meet intelligence.

Data Centre. Design and Project Management. from concept to completion

MARULENG LOCAL MUNICIPALITY

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Datacentre Capability March 2015

Transcription:

Technical specifications Containerized data centre NTR CDC 40f+

CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION REQUIREMENTS... 4 2.4 COMMUNICATION CONNECTION REQUIREMENTS... 5 3 TECHNICAL SPECIFICATIONS OF NTR CDC 40F+... 6 3.1 BASIC LAYOUT OF NTR CDC 40F+... 6 3.2 KEY CAPACITIES OF NTR CDC 40F+... 6 3.3 BASIC COMPONENTS... 7 3.4 POWER SUPPLY... 8 3.5 SYSTEM AND EMC PROTECTION... 8 3.6 TECHNICAL COOLING SYSTEM... 9 3.7 ENERGY EFFICIENCY... 9 3.8 SECURITY AND SURVELIANCE SYSTEMS... 9 3.9 REMOTE CONTROL AND LOCAL MANAGEMENT INFRASTRUCTURE... 10 2 10

1 THE PURPOSE OF CDC NTR CDC 40f+ je is a standalone, self-sufficient data centre unit with highest level of energy efficiency. CDC is shaped as a container and thus it is entirely mobile. This mobile unit includes a server room with all necessary additional support and surveillance infrastructure. It is easy to install, does not require massive preparations for building on the location and is easily moved to a new location. Relocation is possible with the equipment installed in the CDC. It provides a perfect installation for small to medium sized companies that need up to 420 U rack space for operation of their own system. Its design slightly exceeds the standard 40 foot container dimensions, thus the whole length of the container is standardized at 40 or 12.2 metres. Consequently, the data centre can be transported to a new location by road or by rail. It works best for companies whose business needs, surveillance or remoteness requires them to have their own information infrastructure together with basic installation requirements. The containerised data centre unit provides all the necessary support infrastructure including: A reliable power supply system with diesel genset and redundant UPS units; A reliable technical cooling system; An active and passive fire prevention system; A security and video surveillance system; A communication wiring inside container; All necessary 19 infrastructure for server installation; A remote control system for monitoring of all in-built systems. 3 10

2 BASIC PROPERTIES 2.1 EXTERNAL DIMENSIONS External dimension of CDC 40f+ are 12.2 x 3.0 x 3.1 m (L x W x H). An empty unit weight approximately 10,000 kg, maximum load of installed equipment is 12,000 kg. Specification Estimated weight Empty CDC Up to 10,000 kg, depending on the installed systems Number of system racks Up to 10 Maximum load of single rack Available installation space in system racks Maximum load of installed equipment Maximum total load of full CDC Up to 1,200 kg Up to 420 U Up to 12,000 kg Up to 22,000 kg 2.2 INSTALLATION REQIREMENTS Before installing the CDC, the loading force of the foundation needs to be adequately prepared. Each project requires a different foundation preparation depending on the location. For proper functioning, a space of approx. 15.4 m x 5 m (W x L) is needed, as seen on the scheme below: 1.6m 1.6m 1.0m 5.0m 1.0m 15.4m To install NTR CDC 40f+ at least 5 m in height is required. Additional external units of technical cooling are installed on the base unit. They are assembled on location on pre-prepared installation points. Minimal spaces require location inspection. 2.3 ELECTRICAL CONNECTION REQUIREMENTS NTR CDC 40f+ is equipped with a diesel genset and at least two independent UPS systems. Therefore, only mains connection on the installation site is required. For cable inlet there is a separate cable duct near the main entry door to the CDC. Usually mains connection is in a 3 phase version with a TN-S protection system. Recommended mains voltages are 400V/50HZ, but on request, other versions are available. Recommended mains connection power is between 100 and 160 A per phase. 4 10

2.4 COMMUNICATION CONNECTION REQUIREMENTS All necessary communication wiring inside NTR CDC 40f+ is already installed. Details are available upon request. In the production phase, wiring can be adapted according to the customer s needs. Communication wiring and equipment for remote control and monitoring systems are independent from other communication systems in the CDC. A separate cable duct is available for connection to the customer s external location network. Connection can be made with Ethernet Cat6A or Fiber optic cables. 5 10

3 TECHNICAL SPECIFICATIONS OF NTR CDC 40F+ 3.1 BASIC LAYOUT OF NTR CDC 40f+ The NTR CDC 40f+ is designed as a standalone, self-sufficient data centre unit with all necessary support infrastructure provided. Technically it is designed as a standard length container unit with some extra width and height. This enables easy and comfortable transport to different locations. Due to high degree of integration and space optimization, NTR CDC 40 f+ functions in the same way as much larger data centres. Layout is described on the picture below. Service entrance for technical cooling systems HO A HO B Server room SIST 9 SIST 8 SIST 7 SIST 6 SIST 5 SIST 4 Cold aisle Hot aisle SIST 3 TK 2 TK 1 R-AGR UPS-A R-UPSA UPS-B R-UPSB Power supply room and utility space Genset room Main entrance Entrance for genset The unit is divided into three physically separated rooms, which provides fire safety and security. These three rooms are: System room for installation of customer s IT equipment. It is built as a separate security and fire prevention unit. An automatic fire suppression system is installed. The system room contains system racks together with cooling devices. For efficient cooling, Cold and Hot aisle separation is installed; Power supply and utility room, also built as a separate fire prevention and security unit. All power supply systems, extinguishing supply and other common equipment are placed inside; Diesel generator set room with diesel generator inside. 3.2 KEY CAPACITIES OF NTR CDC 40F+ The NTR CDC 40f+ containerised data centre has the following basic capacities: Capacities of system racks Specifications Available equipment installation space Technical cooling system principles Capacity of technical cooling with full redundancy Capacity of technical cooling without redundancy Key capacities Up to 10 system racks with dimensions 600 x 1000 x 2000 (W x D x H), or any other combinations of system and communication racks with dimension 800 x 1000 x 2000 (W x D x H), total width of all racks is 6000 mm Up to 420 U Direct free cooling with additional mechanical cooling 31 kw or 45 kw of cooling power 60 kw or 85 kw of cooling power Capacity of uninterruptable power supply with full redundancy 40 kva/32 kw or 60 kva/48kw at CosFi 0,8 Capacity of uninterruptable power supply without redundancy 80 kva/60 kw or 110 kva/88kw at CosFi 0,8 6 10

Autonomy of uninterruptable power supply system Type of backup power supply Capacity of backup power supply Autonomy of backup power supply Typical energy efficiency - PUE Fire protection in CDC Security surveillance Video surveillance Access control principles Remote control min 15 min at full load diesel generator set with instant automatic start up at power outage aprox. 100 kva min 48 hour, extendable with fuel supply as low as 1,2, dependable on installation location climate conditions early fire and smoke detection with fire suppression system security surveillance with alarm transfer in whole CDC video surveillance in whole CDC, access control on all doors with RFID, biometrics upon request Integrated comprehensive remote control and monitoring system of all support infrastructure, installed in CDC, with http/https and SMTP support This is the basic layout of the NTR CDC 40f+ with key internal dimensions: 7.735m 12.190m 0.895m 0.840m 6.000m 2.327m 1.712m 3.000m 2.800m HO A HO B 1.035m 1.005m 0.760m Server room SIST 9 SIST 8 SIST 7 SIST 6 SIST 5 SIST 4 SIST 3 TK 2 TK 1 R-AGR UPS-A R-UPSA UPS-B R-UPSB Power supply room and utility space Genset room Main entrance Entrance for genset 3.3 BASIC COMPONENTS The NTR CDC 40f+ containerized data centre is designed as an independent unit. In case of power outages, 48- hour local power supply is guaranteed. Longer autonomy can be achieved with appropriate fuel delivery. NTR CDC 40f+ is built with carefully selected components designed to be used in data centres. Components are optimal for working under extreme conditions and special attention was put into their integration and container data centre implementation. The following producers provide components for the centre: Basic components: Modular fire prevention walls with fire resistance EI90 according to EN 13 501-2; Fire resistant and smoke proof door; Antistatic raised floor; Roxtec water and gas proof cable ducts. Power supply: Diesel generator set with Perkins engine and Stamford generator; UPS systems Piller with Hoppecke batteries; Eaton Moeller switch gears; 7 10

Rittal electrical switchboard and PDU units. Technical cooling systems: Weiss Klimatechnik data centre cooling systems with direct free cooling; Cold and Hot aisle separation. IT equipment installation infrastructure: Rittal system and communication racks; Metz Connect communication network. Security systems: Siemens fire suppression system with early detection; Security surveillance with access control; Mobotix video surveillance with IP cameras. Local management infrastructure and remote control: WAGO PLC and control units; Certech SCADA system. B&R industrial computer and touch screen display, 3.4 POWER SUPPLY Key features: Input voltage 400V/50Hz 3ph or 230V/50HZ 1ph AC, other versions upon request; Mains input power approx. 80-105 kva; In-built spare power source with diesel genset, standby power approx. 100 kva; Internally designed and optimized genset with automatic startup and automatic transfer switch for power transfer between main and spare power source; Upon request possibility of synchronous power transfer without interruption between mains and spare power source; Diesel genset with pre heating unit for fast start up of the genset; In-built day fuel tank with additional main fuel tank. Both together have the capacity to ensure autonomous operation for 48 hours; Two independent UPS systems (2N redundancy) with nominal power of 40 kva and batteries that ensure autonomous operation for 15 min; Upon request two independent UPS systems with nominal power of 60 kva; Independent switch and distribution boards for each UPS system; Redundant power cabling to each system and communication rack. Each rack is equipped with two independent PDU units; PDU units with C13 and C19 outlets. Final layout is made according to customer s needs; Upon request implementation of two independent Static Transfer switches for automatic transfer between two UPS systems; LED lighting with motion detection; Upon request possibility for lighting exterior of CDC with motion detection. 3.5 SYSTEM AND EMC PROTECTION Key features: CDC system designed as Faraday cage; 8 10

Meshed equipotential bonding; Upon request additional EMC protection on all cable ducts; Surge protection implemented on power inputs; Raised floor with antistatic properties; Upon request Tempest protection. 3.6 TECHNICAL COOLING SYSTEM Key features: High efficiency technical cooling system with direct free cooling. In case of low external temperatures, it utilizes external air for direct cooling of IT equipment. In bad weather conditions, it uses the mechanical cooling principle. The system is designed for maximum power savings; therefore, it is capable of utilizing both cooling principles; Fully redundant technical cooling system with 2N redundancy; DX cooling device with FC capabilities; Under floor cold air distribution to the Cold aisle; Cold and Hot aisle separation in the system room; Recommended temperature for Cold aisle is from 23 to 27 C; Additional cooling of Power supply room with fire separation between System and Power supply room; External unit of cooling systems are installed on the top of the CDC; Additional service door for external maintenance of cooling devices without the need for entrance into the System room. 3.7 ENERGY EFFICIENCY Energy efficiency of the NTR CDC 40f+ is one of its most important features. Due to optimization of technical cooling and power consumption of the support systems, NTR CDC 40f+ can achieve PUE as low as 1.2. Results of power efficiency depend on several conditions, including environment, general power consumption in CDC, and preferred temperature in the Cold aisle. Key reasons for low PUE are: Cold and Hot aisle separation; Utilization of direct free cooling; Relatively high recommended temperature in Cold aisle; High energy efficiency of UPS and other support systems. End PUE depends on the end installation location and environmental conditions. Under ideal circumstances, PUE can be as low as 1.08 in extreme locations. 3.8 SECURITY AND SURVELIANCE SYSTEMS Security is, along with reliability, another key advantage of the NTR CDC 40f+. In CDC implemented security and surveillance systems include: Three separate fire protected rooms; Early fire detection and alarm system in all rooms with analog addressable fire alarm control panel and additional aspirating detectors in the System room; Fire suppression system with NOVEC 123 fire suppression supply; Security, fire and smoke resistant doors between rooms; Technical surveillance and mechanical protection with separate security zones in all rooms; Access control with RFID cards and personal PIN number; 9 10

Upon request, the option of biometric access control; Door opening alarm on all doors with option for interlocking between main entrance and System room entrance door; Remote control and supervision of all doors and security systems; Video surveillance in all rooms in CDC. 3.9 REMOTE CONTROL AND LOCAL MANAGEMENT INFRASTRUCTURE One of the key factors for secure and reliable operation of all data centres is remote control and management of data centre infrastructure. Therefore, an advanced remote control and management system with local management infrastructure is built in to the NTR CDC 40f+. Its main features are: Monitoring and control of power supply system: Electrical measurements of mains inlets; Electrical measurements and control of ATS; Measurement and control of genset operation; Automatic genset testing; Measurement and monitoring of fuel system; Monitoring of all switches, protection and other devices in electrical distribution panels; Measurement and control of UPS systems; Electrical measurement on each system rack and PDU unit; Electrical measurement of cooling systems. Monitoring and control of cooling system: Remote control and monitoring of cooling units; Independent measurement and monitoring of temperatures on different locations inside CDC; Control and monitoring of free cooling system; On line measurement of instant PUE, daily, weekly and yearly average PUE. Monitoring of security systems: Monitoring of doors in CDC; Monitoring of other security systems; Transfer of alarm signals to remote location. Alarm management; Comprehensive historization; On/off line trending; Local management display with synoptic overview of the whole CDC; Remote access to the LMI through secured HTTPS; SMTP support for alarm and information transfer to other management systems; Alarm transfer via e-mail and upon request via SMS. 10 10