PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup



Similar documents
Troubleshooting. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright Palo Alto Networks

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

Guide to SATA Hard Disks Installation and RAID Configuration

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

RAID 1(+0): breaking mirrors and rebuilding drives

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card.

AMD SP5100 Dot Hill SATA RAID Users Manual V100

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Guide to SATA Hard Disks Installation and RAID Configuration

RocketRAID esata 3G HBA Series Bootable RAID. Installation Guide.

Guide to SATA Hard Disks Installation and RAID Configuration

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

User Manual. For more information visit

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Navigating the Rescue Mode for Linux

How To Use A Raid

Intel Matrix Storage Console

This user guide describes features that are common to most models. Some features may not be available on your computer.

RAID1 rebuild procedure for Intel Matrix Storage Manager

Recovering from a Hard Drive Failure

NVIDIA RAID Installation Guide

Xserve G5 Using the Hardware RAID PCI Card Instructions for using the software provided with the Hardware RAID PCI Card

RocketRAID mini-sas 6G HBA Series Data RAID. Installation Guide

Upgrading Cisco UCS Central

Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright Palo Alto Networks

DF to-2 SATA II RAID Box

Rev B. Removing and Replacing Hard Disk Drives on Sun Server Platforms User Guide

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

Information Systems Services. SafeGuard Enterprise. enc. Device Encryption (DE) Installation V /11/2010

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Getting Started With RAID

Adaptec SAS RAID Configuration and the Windows OS Installation Instructions

This user guide describes features that are common to most models. Some features may not be available on your computer.

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Using GIGABYTE Notebook for the First Time

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

This chapter explains how to update device drivers and apply hotfix.

Intel Matrix Storage Manager 8.x

HP Embedded SATA RAID Controller

How To Add Drives To A Dip N Recording Appliance

Intel Rapid Storage Technology

Panorama High Availability

WD My Cloud EX4 Personal Cloud Storage Release Notes for Firmware

Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later

Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature

How To Set Up Software Raid In Linux (Amd64)

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later

Intel RAID Volume Recovery Procedures

Manage Licenses and Updates

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

RAID 1(+0): breaking mirrors and rebuilding drives

ZOTAC RAIDbox User s Manual

RAIDCore User Manual P/N Revision A December 2009

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Using GIGABYTE Notebook for the First Time

RAID installation guide for ITE8212F

Rebuilding a Show Store RAID with the original drives

This is when a server versus a workstation is desirable because it has the capability to have:

Guide to SATA Hard Disks Installation and RAID Configuration

This user guide describes features that are common to most models. Some features may not be available on your computer.

These application notes are intended to be a guide to implement features or extend the features of the Elastix IP PBX system.

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

PCI Express SATA / esata 6Gb/s RAID Card User Manual

Using GIGABYTE Notebook for the First Time

HP One-Button Disaster Recovery Solution for ProLiant Servers

Intel Data Migration Software

Cloud Attached Storage

Time Stamp. Instruction Booklet

Promise FastTrak 100-Lite RAID Controller

esata 6G RAID PCIe 2.0 Controller Card

Using GIGABYTE Notebook for the First Time

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

RSA Security Analytics. S4 Broker Setup Guide

AMD RAID Installation Guide

VIA RAID Installation Guide

Manage Log Collection. Panorama Administrator s Guide. Version 7.0

Practical issues in DIY RAID Recovery

Disaster Recovery Guide

Secure Perfect RAID Recovery Instructions

Sample of Hardware Equipment Acceptance Form

What s New in VMware vsphere Storage Appliance 5.1 TECHNICAL MARKETING DOCUMENTATION

Acronis True Image 2015 REVIEWERS GUIDE

AMD RAID Installation Guide

Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR SAS/SATA RAID Controllers AFM-700 Flash Backup Unit

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Getting Started Guide

YubiKey OSX Login. yubico. Via Yubico-PAM Challenge-Response. Version 1.6. October 24, 2015

McAfee Firewall Enterprise

Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management

Using the IPMI interface

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Intel Server Raid Controller. RAID Configuration Utility (RCU)

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Marvell SATA3 RAID Installation Guide

Configuring ThinkServer RAID 100 on the TS140 and TS440

Upgrading a single-controller FAS2220 system by moving its internal disk drives to an external disk shelf

Transcription:

PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup 2014, Palo Alto Networks, Inc. https://paloaltonetworks.com/documentation P/N 810-000076-00C

Contents OVERVIEW...3 SSD UPGRADE PROCEDURE...3 CONFIGURING RAID WITH TWO 120GB SSDS...3 CONFIGURING RAID WITH MATCHING SSD MODELS... 4 CONFIGURING RAID WITH MISMATCHED MODELS OF SSDS... 4 UPGRADING FROM A SINGLE 120GB SSD TO A SINGLE 240GB SSD... 6 CONFIGURING RAID WITH TWO 240GB SSD DRIVES... 7 SWAPPING DRIVES BETWEEN FIREWALLS...8 REPLACING A FAILED SSD IN A SYSTEM WITH ONLY 1 SSD...8 REVISION HISTORY...8 2014, Palo Alto Networks, Inc. [2]

Overview All PA-5000 Series firewalls are equipped with two slots for Solid State Drives (SSDs). These models ship standard with single or dual 120GB or 240GB SSD drives, which are field upgradeable. The PA-5000 Series supports the following configurations of SSD storage devices: Single 120 GB SSD Dual RAID 120GB SSDs Single 240 GB SSD Dual RAID 240GB SSDs WARNING: Palo Alto Networks has determined that there are long-term reliability issues with running RAID with mixed drive models, even if those drives are from the same vendor. Do NOT configure a system in RAID mode with different SSD drive models. If you are already running a system in RAID mode with different SSD part numbers, please contact support for assistance. If you are installing an SSD that is mismatched (not the same size as the existing SSD), you must use a console connection to perform this procedure because you will be required to go into maintenance mode to configure the RAID. In addition, if you install a second SSD that has an OS on it, or if you interrupt the bootup process too early, you will need to go to maintenance mode to configure RAID. After entering maintenance mode, you will select the primary boot drive as the existing drive. After selecting the primary boot drive, the system will then initialize the second drive in the RAID pair along with the original drive. For more details, see Configuring RAID with Mismatched Models of SSDs. SSD Upgrade Procedure This document covers the different upgrade options and procedures that are available. RAID 1 will be enabled on the systems with two SSDs. Important: 1. The SSD drives are not hot swappable. Ensure that the firewall is powered off before installing or removing drives. 2. This equipment may be affected by electrostatic discharge. ESD reduction procedures (wearing a wrist strap) shall be implemented during the installation and maintenance of this equipment. 3. Using mismatched drive models will result in the system booting into maintenance mode. Palo Alto Networks only supports using mismatched drives during the upgrade steps outlined in the section Configuring RAID with Mismatched Models of SSDs. 4. While the RAID set is building or rebuilding, logging performance may be degraded. Palo Alto Networks recommends that you complete these steps during a maintenance window. Configuring RAID with Two 120GB SSDs This procedure covers migration steps to upgrade a PA-5000 Series device from a single SSD to a dual SSD configuration. This section also covers the case of a system being migrated from 1 to 2 drives and the scenario where a RAID configured system experiences a drive failure. 2014, Palo Alto Networks, Inc. [3]

Note: To determine the drive model of the SSD currently installed in your firewall, run the command show system raid detail. Make sure that the new drive that will be installed in the RAID configuration has an identical model number. Configuring RAID with Matching SSD Models In order to configure RAID with standard 120GB SSDs, power off the system, insert the second drive into the open disk bay and power on the system. The system automatically puts the drives into a RAID 1 pair and performs the data mirroring in the background if the drive models match. This process can take up to an hour or more. Use the command show system raid detail to view the SSD status. Configuring RAID with Mismatched Models of SSDs If you do not have an identical drive, or need to order replacement/additional drives, Palo Alto Networks now ships all spare SSD drives for the PA-5000 in matching pairs. Part number PAN-PA-5000-SSD-120-D allows you to upgrade to RAID regardless of the current drive model. To upgrade the system, power off the system, open the drive bay, and insert one of the new blank drives into the second drive bay. Close the cover and power on the system. The system boots up and recognizes the second drive. The system will recognize mismatching drives and will boot into maintenance mode. If the system does not boot into maintenance mode automatically, you can run the following command after logging into the firewall: debug system maintenance-mode. You can also reboot the firewall and when you see the message Autoboot to default in 5 seconds. Enter maint to boot to maint partition, type MAINT within 5 seconds to enter maintenance mode. From the Maintenance Recover Tool menu, select RAID. To begin the process, choose the Migrate drive 1 -> 2 option (assuming the new drive is installed in drive bay 2). This will initiate the migration process. 2014, Palo Alto Networks, Inc. [4]

Note: If the drive installed matches the existing drive, the system will NOT boot into maintenance mode and will automatically put the second drive into the RAID array and begin the mirroring process. The RAID migration status screen shown below is displayed once the migration is completed. After the data migration is completed, power off the system and remove the old drive with the mismatched model number (120GB SSD). The new 120GB SSD can be left in the second disk bay or moved to the primary bay. Power on the system to verify system functionality. In order to complete the RAID configuration, power off the system, open the drive bay cover and insert the matching second drive into the available drive bay. Close the cover and power on the system. The system automatically performs the data mirroring in the background. Use the command show system raid detail to view the SSD status. 2014, Palo Alto Networks, Inc. [5]

Upgrading from a Single 120GB SSD to a Single 240GB SSD Note: Do not leave the system running with mismatched drives (120GB and 240GB) in production. Please plan your maintenance time to allow for the completion of this step. Depending on the size of the logs on the original drive, this process may take up to an hour or more. In order to upgrade from a single 120GB SSD to a single 240GB, power off the system open the drive bay, insert the blank 240GB drive into the second drive bay. Close the cover and power on the system. The system boots up and recognizes the second drive. The system will recognize mismatching drives and will boot into the maintenance mode screen. From the menu option select RAID. The following screen shows the information about the available SSD and data migration options. In order to migrate from a 120GB SSD to a 240GB SSD, choose the Migrate drive 1 -> 2 option. 2014, Palo Alto Networks, Inc. [6]

This will initiate the migration process. The RAID migration status screen shown below is displayed once the migration is completed. When the migration is completed, power off the system and remove the drive with the mismatched model number (120GB SSD). The new 240GB SSD can be left in the second disk bay or moved to the primary bay. You can then power on the system to verify the operation. Once the system boots up, you can verify the disk space to confirm the 240GB SSD is in use with the show system disk-space command. The output will be similar to the following: admin@pa-5060> show system disk-space Filesystem Size Used Avail Use% Mounted on /dev/md2 3.8G 1.2G 2.5G 32% / /dev/md5 7.6G 562M 6.6G 8% /opt/pancfg /dev/md6 3.8G 401M 3.2G 11% /opt/panrepo tmpfs 1.8G 37M 1.7G 3% /dev/shm /dev/md8 198G 189M 188G 1% /opt/panlogs Configuring RAID with Two 240GB SSD Drives The firewall must use identical SSD drives in a RAID configuration. The part number PAN-PA-5000-SSD- 240-D can be purchased, which provides two identical drives. Please follow the steps provided in the section Upgrading from a single 120GB SSD to a single 240GB SSD to migrate data from 120GB SSD to 240GB SSD. You can then build the 240GB RAID set with the second 240GB SSD drive. First, power off the system, insert the second drive into the open disk bay and then power on the system. The system automatically puts the drives into a RAID 1 pair and performs the data mirroring in the 2014, Palo Alto Networks, Inc. [7]

background if the drive models match. This process can take up to an hour or more. Use the command show system raid detail to view the SSD status. Swapping Drives between Firewalls This section describes the sequence of steps required to swap SSD from one PA-5000 Series firewall to another. The firewalls must be powered off before you perform this procedure. In this example, we assume the drives are moved from firewall#1 to firewall#2. 1. Power off both firewalls 2. Remove all SSD drives from firewall #1 3. Insert all SSD drive to firewall #2 4. Power on firewall #2 5. Firewall #2 may reboot once during the first boot with the new drives 6. Firewall #2 will come up to its normal login prompt 7. Perform license migration for the new serial number. Contact Palo Alto Networks support for migration information. Note: Drives should always be moved as a group. If the original system has two drives, they should be moved together. Replacing a Failed SSD in a System with Only 1 SSD If a firewall with a single SSD has a drive failure, a new SSD with the PAN-OS image must be installed. You can order the imaged drive using the part number PAN-PA-5000-SSD-120-IMG or PAN-PA-5000-SSD-240- IMG (depending on whether the system contains a 120GB or 240GB SSD). The sequence of steps required to replace the single failed SSD is listed below: 1. Power off the firewall. 2. Remove the failed SSD drive from the firewall. 3. Insert the imaged SSD drive into the firewall. 4. Power on the firewall. 5. Upgrade or downgrade the system in order to return to your previous version of PAN-OS. 6. Restore your configuration from your backups. Revision History Date Revision Comment December 3, 2014 C In the section Configuring RAID with mismatched Models of SSDs it states that if a mismatched drive (SSD drive of a different type) is installed, the system will reboot into maintenance mode. The system may not always boot into maintenance mode, so we added information on how to boot into maintenance mode. Note: Doc revision is still Rev C in order to accommodate revision history for the printed version. Palo Alto Networks now supports multiple drives in the PA-5000 Series firewall. May 22, 2012 B Improved the depth of content. 2014, Palo Alto Networks, Inc. [8]