A Novel Approach to Low Volume Sample Preparation

Similar documents
Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Oasis HLB Cartridges and 96-Well Plates

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Thermo Scientific Chromatography Columns and Consumables Your world of. chromatography

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Purification of reaction mixtures using flash chromatography.

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Solid Phase Extraction for Water Analysis. presented by

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

How To Test For Contamination In Large Volume Water

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

PrepTip. Reverse Phase PrepTip User Guide

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Innovative vs Traditional

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Click on Table of Contents. Then type desired page number & click OK.

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Sample Preparation Using Solid Phase Extraction

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Introduction. Methods. Sample Processing

Thermo Scientific Mass Spectrometric Immunoassay (MSIA)

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

RapidFire for High Throughput Screening in early Drug Discovery

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

The Theory of HPLC. Gradient HPLC

Affi-Prep Protein A Matrix Instruction Manual

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

SPE Reference Manual & Users Guide. Reference Manual & Users Guide

An Improved SPE-LC-MS/MS Method for the Quantification of Bradykinin in Human Plasma Using the ionkey/ms System

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

ORGANIC SAMPLE PREPARATION

Successful Sample Preparation Strategies for LC/MS/MS Analysis of Drugs in Complex Biological Matrices for Forensic Toxicology Applications

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Protocol: HPLC (amino acids)

Automation of Sample Preparation in Ion Chromatography

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

ab Protein Sumoylation Assay Ultra Kit

An In-Gel Digestion Protocol

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

LC-MS/MS STRATEGIES FOR QUANTIFICATION OF THERAPEUTIC ANTIBODIES TO SUPPORT CLINICAL

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC

International Journal of Pharma and Bio Sciences V1(2)2010

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

LC Application Note.

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

INSTRUCTIONS Edition AC

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

Overview. Purpose. Methods. Results

The basic division explosives for forensic purposes is shown in Fig. 1

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K =

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Bulk Materials for Preparative and Process Chromatography

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Thermo Scientific Syncronis HPLC Columns. Technical Manual

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Matrix Effect in Bio-Analysis of Illicit Drugs with LC-MS/MS: Influence of Ionization Type, Sample Preparation, and Biofluid

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Training Courses 2014 HPLC GC SPE

A Determination of Veterinary Drug Residues in Milk Using Polymeric SPE and UHPLC-MS/MS Analysis

S olid Ph ase Extraction (SP E) Method:

Transcription:

A Novel Approach to Low Volume Sample Preparation Tony Edge, Jon Bardsley, Ken Meadows, Luisa Pereira International Symposium on Chromatography Salzburg, Austria September 2014 1 The world leader in serving science

Introduction Identifying the challenges associated with bioanalysis Matrix issues Regulatory Sample volumes Improving recovery using Improved design of SPE material Overcoming matrix and sample volume issues Troubleshooting a mixed mode SPE method Issues with recovery Effect of buffer 2

Chromatography of a Typical Matrix 100 0.47 0.73 1.06 2.36 2.44 2.74 2.99 3.11 3.463.66 4.11 1.02 3.81 4.66 6.45 6.76 1.16 2.34 5.20 2.29 % 2.28 3.97 1.81 2.19 4.73 6.04 1.29 2.70 4.35 4.79 5.05 5.08 5.32 5.69 5.76 6.11 4.49 6.14 5.65 5.44 7.23 7.31 7.02 0 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 Tim LC-MS of Mouse Urine, full scan (with kind permission of Ian Wilson) 3

Challenges within Bioanalysis Matrix Effects Polar head fragment=184.3m/z 4

Challenges within Bioanalysis Matrix Effects 1.20E+06 Detector Response 1.00E+06 8.00E+05 6.00E+05 496 524 704 758 806 4.00E+05 806 2.00E+05 704 758 0.00E+00 524 PPT SOLA SOLA CX 496 5

Challenges within Bioanalysis Matrix Effects 100% 90% 80% 70% 496 60% 50% 40% 30% 524 704 758 20% 806 10% 0% 1 2 3 4 5 6 7 8 9 10 496 524 806 758 704 6

Challenges within Bioanalysis - Regulatory..Changes in the response function relationship between pre-study validation and routine run validation indicate potential problems. Internal standard response should be monitored for drift. An SOP should be developed a priori to address issues related to variability of the IS response. 7

Challenges within Bioanalysis Reproducibility of IS 60000 50000 IS Response 40000 30000 20000 10000 0 0 50 100 150 200 Sample Number SPE extraction Protein precipitation SPE gives better reproducibility than protein precipitation 8

Meeting the Challenges with Bioanalysis Thermo Scientific SOLAµ SPE plates No frits - no movement Fixed media position Improved flow characteristics Improved reproducibility Fewer failures Improved throughput and efficiency 9

SOLAµ Plates Improved Flow Through Characteristics How does SOLAµ plates provide this? Consistent manufacture ensures the same amount of material is packed every time. Frits act as a barrier to flow, removal aids flow. Space between media is not controlled by packing density (diagram). SOLA unit structure has increased porosity due manufacture control. Conventional loose packed SPE 10

Challenges within Bioanalysis Reproducibility of IS 1.4 Loosed packed SPE (i) 10mg Neostigmine 1.2 1 0.8 0.6 0.4 Reproducibility Data Endrophonium Neostigmine Pyridostigmine %RSD (n=20) without IS 23.7 24.5 22.0 %RSD (n=20) with IS 5.7 5.9 8.5 No IS Correction IS Corrected 0.2 0 0 5 10 15 20 25 11

Challenges within Bioanalysis Reducing Sample Size Move away from composite animal studies Scientifically a little dubious Uses less animals / samples 1.5 mls of blood in a mouse 5-10 time points Allows lower quantification limits Neo-natal patients Current legislation means that new born children have to be tested with a drug that is tested on them Minimal sample volume available 12

Challenges within Bioanalysis - Blowing down a Sample Non specific binding Workflow efficiency Volatility 13

SOLAµ Plates - Sample Limited Extraction (25µL) Extraction of niflumic acid from human plasma 25µL of sample Equivalent results on 2mg SPE to higher sample volume extraction using 10mg SPE High reproducibility 14

SOLAµ Plates - Sample Limited Extraction (25µL) Sample pre-treatment 25 (250) μl of human plasma diluted with 1:1 with 4% phosphoric acid Sample preparation: Condition 200 μl methanol Equilibrate 200 μl water Load Apply sample at 0.5 ml/min Elute 2 x 12.5 (125) μl methanol with 2% ammonia Direct injection of eluent SOLAμ WAX plate used Text in red is original 10mg method volumes 15

SOLAµ Plates - Sample Limited Extraction (25µL) 500,0000 250 μl sample size 500,0000 25 μl sample size 16

SOLAµ Plates - Sample Enrichment (20x Pre-Concentration) Sample pre-treatment: 500 (500) μl of human plasma diluted with 1:1 with 4% phosphoric acid Sample preparation: Condition 200 μl methanol Equilibrate 200 μl water Load Apply sample at 0.5 ml/min Elute 2 x 12.5 (250) μl 50/50 methanol/acetonitrile with 2% ammonia Direct injection of eluent SOLAμ WAX plate used 17

SOLAµ Plates - Sample Enrichment (20x Pre-Concentration) Increase in signal response x 20 using smaller elution volume 18

What Can Go Wrong with a Mixed Mode SPE? WCX has a pk a ~ 4.5 Below ph 4.5 sorbent neutral Above sorbent negatively charged Do not assume that deionised water has a ph of 7 This will have a dramatic effect on the stability of a WCX method / or where the nature of the analyte is assumed based on the ph 19

Start Method Sample 250 μl plasma + 200 μl H 2 O Condition Equilibrate Load Sample Wash 1 Wash 2 Elute 250 μl MeOH 250 μl H 2 O 250 μl H 2 O 250 μl MeOH 2% formic acid in MeOH (v/v) 20

Affect of Loading Speed with Compound in Matrix 100 80 Recovery 60 40 Fast Load Slow Load 20 0 Loading Speed 21

Effect of Dilution Solvent on Recovery 110% 100% 1:40 Aqueous solution % Recovery 90% 80% 70% 1:1 1:2 1:3 1:10 1:20 60% 50% 1:1 1:2 1:3 1:10 1:20 1:40 P/S Plasma : dilution solvent ratio Dilution of sample can have an effect on recovery 22

Buffered Method Controlling the Sorbent Charge Sample 200 μl plasma + 800 μl ph7 buffer Condition Equilibrate Load Sample Wash 1 Wash 2 Elute 200 μl 80/20 MeCN/MeOH 2% formic acid 200 μl ph7 buffer 200 μl ph 7 buffer 200 μl 80/20 acetonitrile / methanol (v/v) 2x 50 μl 2% formic acid in 80/20 acetonitrile / methanol (v/v) 23

Use of Appropriate Buffering Conditions 100% 90% 80% 70% 60% 50% 40% Plasma Ex diln ph7 buffer Water Ex diln ph7 buffer 30% 20% 10% 0% %Rec Recovery increased from plasma samples following addition of buffer Aqueous solution maintained high recovery 24

Conclusion Identifying the challenges associated with bioanalysis Matrix issues Regulatory Sample volumes Improving recovery using Improved design of SPE material Overcoming matrix and sample volume issues Troubleshooting a mixed mode SPE method Issues with recovery Effect of buffer 25