Category 8 Cabling Standards Update



Similar documents
CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Copper Patch Cords. Impact On Network Performance and Reliability

Category-6 / Class-E Cabling

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

TIA Fiber Optics LAN Section (FOLS) LAN Standards, News & Trends Report

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek

Data Communications Competence Center

Laying the groundwork for a new level of Power over Ethernet

HARTING Ethernet Cabling 8-poles Overview

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Accelerating Light. Copper Cabling Solutions. Category 6A

PROFINET New Cabling for Gigabit Ethernet End-to-End Link (E2E) Dipl.-Ing. Rainer Schmidt HARTING

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

40GBASE-T Advantages and Use Cases

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

InstaPATCH Cu Cabling Solutions for Data Centers

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

with Component Rating A Simple Perspective

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

TIA Releases Guidelines for Maintaining Polarity Using Array Connectors

How To Properly Maintain A Fiber Optic Infrastructure

Upgrading Path to High Speed Fiber Optic Networks

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

GigaSPEED X10D Solution How

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

The High Cost of a Low-Cost Cable Certification Tester

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Terminal and Dimension

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV ) (FA ) (7-12)

Network Design. Yiannos Mylonas

Current access technologies overview

How To Get A Better Signal From A Fiber To A Coax Cable

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Panduit 28 AWG Patch Cords Installation Guideline

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Cabling Standards Update 2014

Total Solutions Verification

Data Center Design for 40/100G

Data Centre & Enterprise Solutions. RapidNet

Obsolete Fiber Technology? Not in my Data Center!

ECONOMICS OF DATA CENTER OPTICS SPIE PHOTONICS WEST INVITED PAPER (9775-2) FEBRUARY 16, 2016

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center

100BASE-SX Fast Ethernet:

Innovative Connectivity Solution for Maximum Performance and Security

Datasheet: DSX-5000 CableAnalyzer

10 Gigabit Ethernet over copper: Unshielded, unprotected?

CommScope Intelligent Building Infrastructure Solutions (IBIS)

Optimizing Infrastructure Support For Storage Area Networks

Enhanced Category 5 Cabling System Engineering for Performance

White Paper. Power over Ethernet Plus Update and Cabling Considerations

IT Cabling Solutions

Understanding Fiber Polarity: Implications at 10G, 40G, & 100G

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

10GBASE T for Broad 10_Gigabit Adoption in the Data Center

Ethernet 102: The Physical Layer of Ethernet

HARTING Ethernet Cabling 4-poles Overview

Communication Setup Application Note

Category 6 Cabling Questions and Answers

E Series. E Series. Category 6 and 5e. Features

A Simple Model of Relative Power vs. Reach

Structured and Point to Point Network Cabling for Industrial Automation

Implementing Fast Ethernet

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

BICSI :Building Industry Consulting Service International

SYSTIMAX Copper Solutions Designed for the Digital Generation

Fibre optic testing best practices

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

SHDSL LAN EXTENDER H301A. User Manual

Terminal and Dimension

Gigabit Ethernet on Copper Cabling Infrastructures

MapIT G2 Infrastructure Management

Quick Reference Guide High Speed Input/Output Solutions

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Ethernet over VDSL2 PoE PD Converter

Product Specifications

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Laying the groundwork for a new level of wireless access performance. White Paper

Transcription:

White Paper Category 8 Cabling Standards Update TIA TR42.7 Study Group for Class II Limits

Contents 1 Background 3 2 Impact of this approval on Category 7 A cabling 3 3 Differences between Class I and Class II cabling 3 3.1 Will connectors used in Class II channels be backward compatible to existing cabling? 4 3.2 Will connectors used in Class II channels be backward compatible to LAN and SAN equipment? 4 4 Category 7/7 A market share 5 5 Summary 5 6 References 6 2

1 Background At the TIA TR42 plenary meeting on June 12, 2013 in Portland, Oregon, the TR42.7 formulating sub-committee approved the formation of a task group to study the concept of adding ISO/IEC TR 11801-99-1 Class II limits to the draft ANSI/TIA-568-C.2-1 Category 8 cabling standard. The study group is expected to review existing Class II specifications in teleconference calls and submit recommendations to TR42.7 at the next meetings on July 30-31, 2013 and October 8-9, 2013. This approval will allow members of TR42.7, who see advantages in PIMF cabling, an opportunity to contribute towards the development of Class II cabling specifications, as well as category 8.2 component specifications. The work in TR42.7 will have to be carefully coordinated with the ongoing work in ISO/IEC/JTC1/SC25/WG3 developing Class II specifications, IEC 46C developing Category 8.2 cable specifications, and IEC 48B developing Category 8.2 component specifications. 2 Impact of this approval on Category 7 A cabling The formation of the study group for Class II recognizes advances in transmission technology needed for 40 G applications. TIA TR42.7 technical experts had previously rejected a proposal to develop Category 7 A cabling. The decision to develop Class II instead is further confirmation of the need for higher bandwidth and technical improvements beyond Category 7 A needed for 40 G applications. The decision to develop Class II up to 2000 MHz is a clear indication that Category 7 A cabling specified up to 1000 MHz will not be sufficient for 40 G applications. 3 Differences between Class I and Class II cabling The key difference between Class I and Class II cabling is the fact that Class II allows three different styles of connectors that are not compatible with one another, or with the RJ45 connector. This presents a dilemma to the customer who may not have detailed information on the advantages of each connector family. And, since the overwhelming majority of equipment ports, or MDIs, continue to use the RJ45, Class II cabling will require hybrid equipment cords. Class I, on the other hand, uses a fully backward-compatible RJ45-type interface with vastly improved performance relative to Category 6 A connectors and is specified up to 2000 MHz. Another difference between the Category 8 cabling classes is that Class II cabling has higher NEXT and FEXT performance because each of the four pairs are individually shielded. The additional isolation provided by the shield improves NEXT and FEXT of a Category 8.2 cable by about 20 db over Category 8.1 cable used in Class I. This difference is largely immaterial as on-board noise cancellers remove excess internal noise from the channel. The shield effectiveness can only be maintained in the channel if the connectors also have individually shielded pairs and shield continuity is maintained 360 degrees around through the connector. 3

3.1 Will connectors used in Class II channels be backward compatible to existing cabling? The Class II specifications in ISO TR 11801-99-1 do not cover connector types and, by default, refer to ISO 11801 for standardized interface connectors. This means that three different types of connectors allowed in ISO 11801 and ISO 24764 data center cabling for Category 7A including the GG45, ARJ45, and the TERA connectors are allowed in Class II. If the GG45 connector is used, Class II cabling would be backward compatible to other categories if the GG45 jack is mated to an RJ45 plug. However, the GG45 plug is not backward compatible to the RJ45 jack; so, existing cabling with RJ45 interfaces cannot be used with GG45 cords. In addition, the TERA and ARJ45 connectors allowed in the Class II standards will require the use of adapter cords to interface to existing cabling and equipment (see Figure 1 Illustration of TERA jack and ARJ45 plug showing non-compatibility to RJ45 jacks). TERA needs adapter cords to interface to equipment with RJ45 ARJ45 plug with keys on side does not fit into RJ45 jack Figure 1 Illustration of TERA jack and ARJ45 plug showing non-compatibility to RJ45 jacks 3.2 Will connectors used in Class II channels be backward compatible to LAN and SAN equipment? The three connector types allowed for Class II will need to use adapter cords when interfacing to existing equipment that use RJ45 interfaces. As shown in Figure 2: Illustration of GG45 plug from IEC 60603-7-71 standard, the GG45 system has keys on both sides of the plug with matching slots in the GG45 jack that activate a switch in the GG45 jack, allowing the connector to operate in Category 7 A mode or other category modes. Because of this backward compatibility issue and the complexity of the GG45 system, its adoption in the market will continue to be an issue when Class II is deployed in data centers that have lots of equipment with RJ45 interfaces. TERA is a registered trademark of The Siemon Company, and is not associated or affiliated in any way with CommScope, Inc. ARJ45 is a registered trademark of Bel Fuse Ltd. of Hong Kong, and is not associated or affiliated in any way with CommScope, Inc. GG45 is a registered trademark of Nexans Limited Company France and is not associated or affiliated in any way with CommScope, Inc. 4

4 Category 7/7 A market share Recent market data from BSRIA (Building Services Research and Information Association) indicates that the adoption rates of Category 7/7 A cabling and connector interfaces is expected to be around 1.5 percent of the total market in 2013, growing to just 1.9 percent of the market by 2015. In our view, this data confirms the issues that each customer and the market in general see in Category 7 A /Class F A cabling solutions, and confirms that the market share remains low. 5 Summary Protruding keys in GG45 plug will not allow it to mate to RJ45 jack Figure 2: Illustration of GG45 plug from IEC 60603-7-71 standard The approval of the new task group to study Class II channels is a recognition of the advances in PIMF cabling technology needed to support the use of balanced twisted copper cabling for 40 G applications. This recognition is somewhat tempered by the fact that TIA TR42.7 has to deal with the issue of three different connector types allowed for Class II. It is not clear whether TR42.7 will continue to require a single interface allowing portability and interoperability of cabling, LAN, and SAN equipment in data centers that generally use the RJ45 connector as the standard ubiquitous interface for balanced twisted pair cabling. Recent market data from BSRIA indicates that the adoption rates of Category 7/7 A cabling will continue to remain below two percent of the total market through 2015. Our view is that this confirms the issues customers and the market in general face with Category 7 A /Class F A cabling and may continue to haunt the market acceptance and adoption of Class II cabling. A likely reason for this poor adoption is the lack of a standardized interface connector for Class II cabling. 6 References 1. TIA TR42.7 Meeting report from Portland, Oregon, June 2013 2. BSRIA Telecommunications cabling market report, April 2013 www.commscope.com Visit our website or contact your local CommScope representative for more information. 2013 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. WP-107114-EN (07/13)