High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR



Similar documents
Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Commercial Boiler Systems and Controls

Commercial Gas Water Heaters

Commercial Gas Water Heaters

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

Originators of the Flexible Water Tube design

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Gas Water Heater

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

SPIDERfire: Delivers high efficiency and real savings for today s businesses

High efficiency, cast-iron gas boiler

Beware of Exaggerated Claims and Uncertified Manufacturers Ratings Regarding Commercial Boiler Efficiency

Cooling Capacity CFM in. w.c. (125 Pa)

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

Condensing Boiler Efficiency

Better Boilers.

Commercial Gas Water Heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

NAVIEN AMERICA INC FITCH AVENUE

Model CFC ClearFire Condensing Boiler

The Best Selling Domestic Stainless Steel Oil Boiler

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Defining Quality. Building Comfort. Heating and Cooling Coils

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

F9MXE. Product Specifications

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

DESIGNER S HIGH EFFICIENCY GUIDE SYNC COMMERCIAL BOILERS. Up to 98% Thermal Efficiency.

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

ASME Packaged Indirect Fired Water Heater

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

G234X-55 Conventional Gas Boiler

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

SOLI TANKLESS PRODUCT GUIDE

TANKLESS DURABILITY Tankless Product Guide

2010 Residential Water Heater Replacement Check List

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

APG-4R_Layout 1 9/14/11 12:01 PM Page 1 APG-4R XL X F L

G9MXE. Product Specifications

Commercial Semi-Instantaneous Water Heaters

Commercial Gas Furnace Upflow

HEAVY DUTY STORAGE GAS

Diagnostics for Mobile Homes: HVAC

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

LyoBeta. R+D Freeze-Dryers

Builder Specifications for Solar Ready Homes

Evaluating Thermal & Catalytic Oxidation Technology for VOC, HAP & Odor Abatement. John Strey

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Hot Water Heating: Technologies and Use

Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Vitodens 200, B2HA / B2HB - Product Introduction

Typical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.

Installation Instructions

UDSA - UDSBD unit heater

OROT RABIN POWER STATION UNITS x 350 MW

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Fossil fuel heating equipment

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

Rule EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS

2nd IEA Oxyfuel Combustion Conference

Electric & Gas Water Heaters

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

PMI-IF-H High Efficiency Gas Heat Units

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing

IVISIONS STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. INDUSTRIAL BOILER & MECHANICAL

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Factory owners must ensure the boiler is:

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

SIOUX HYBRID WATER HEATER

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

SECTION HOT WATER BOILER HEATING PLANT

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

EVALUATING SCHOOL BOILERS: BEST REPLACEMENT OPTIONS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Some Criteria for Choosing a Steam Boiler for a Microbrewery

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

OTF Oil Fired Pool Heater

ECOCIAT. Domestic hot water heat recovery unit

Retrofit or Replace Boilers? Returning Wealth to the Business S.F. Connor

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

The Concept of Condensing Boilers

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

Installation Manual CLIFC Fan & Coil Variable Speed

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

Transcription:

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR The heat transfer innovators.

THE RELIANCE COPPER FINNED TUBE HYDRONIC BOILER FEATURES Copper Fin-Tube Heat Exchanger Up to 88% Thermal Efficiency Modulation with 5:1 Turndown Color Touch Screen Low Emissions: <9ppm NOx DESIGNED FOR HYDRONIC HEATING The Reliance Boiler was designed specifically for non-condensing hydronic heating applications. The product line includes an extensive offering of models ranging in size from 750,000 to 2,000,000 BTU/HR input. The fully modulating, 5:1 turndown capabilities provide precise load matching to ensure desired building temperatures are maintained. The controller features an easy-to-use touchscreen interface, making adjustments and setup convenient and intuitive. The Reliance Boiler is easy to install and service. All boiler connections are located at the rear of the boiler and are clearly labeled. Access to key components from the front, rear or top of the boiler facilitates one inch side clearance installations. The copper fins in the heat exchanger are formed from one solid copper tube through an extrusion process. The design of the heads provides balanced flow throughout each of the tubes, ensuring even heat transfer.

A LOOK INSIDE THE COMBUSTION PROCESS 1 Gas and air are combined within the venturi and the variablespeed premix blower to create a homogeneous mix for reliable and clean combustion. This is acheived with gas pressures as low as 3.5 wc. Fresh Air Intake Blower 2 Combustion occurs on the outer surface of a stainless steel fiber mesh burner. 3 Combustion is initiated with a Control Interface direct spark or pilot assembly and verified with an ultraviolet flame detector. Venturi 23 mm 4 The burner provides even heat distribution throughout the entire heat exchanger. The heated water takes a three pass course through the copper finned tubes providing a low pressure drop and convenient connection points to the hydronic system. 3 1 Copper Finned Tubes 2 5 Products of combustion pass through the finned tube heat exchanger and are collected in a stainless steel chamber prior to exiting through the boiler s flue stack. 5 Flue Stack 4 Powder Coated Jacket Pressure Vessel Heads

APPLICATIONS AND GREEN BUILDING HYDRONIC HEATING Fulton Reliance boilers can typically be found in commercial building heat applications such as schools, hospitals and government buildings where a reliable source of heat is crucial to maintain daily operations. Designed to work in a closed loop system with modulating capabilities built right in, Reliance boilers ensure that building temperatures are maintained. GREEN BUILDING DESIGN The Reliance can be easily incorporated into LEED and Green Building designs. With thermal efficiencies up to 88% and single phase power requirements, the Reliance factors into the Optimizing Energy Performance calculation under the LEED-NC parameters. Emissions configurations are available as low as <9ppm NOx.

FEATURES AND CONTROLS COLOR TOUCH SCREEN CONTROLS The Reliance control features a color touch screen display, and has an extensive line up of capabilities including pump control, freeze protection, stack temperature monitoring, and complete boiler operation monitoring. With ModBus communication capabilities, low voltage twisted pair communication simplifies multiple boiler installations. Each boiler can be given its own name, personalizing it for any application. Integrated Sequencing control for up to 8 boilers Communication with Building Management Systems via ModBus Network LEAD / MASTER LAG 1 LAG 2

THERMAL EFFICIENCY AND HYBRID SYSTEMS Thermal Efficiency vs. Return Water Temperature 89 The Reliance has optimal thermal efficiency for non-condensing applications. 88 86 85 84 83 82 81 Low Fire Mid Fire High Fire Thermal Efficiency, Percent 87 EFFICIENCY *AHRI Certified 80 79 200 190 180 170 160 150 140 Return Water Temperature, F, 20 F Temperature Differential VALUE ENGINEERED SYSTEMS With a Fulton hybrid boiler system, condensing efficiency and noncondensing affordability are optimized. Fulton has the ability to design custom solutions for our customers which optimize cost saving initiatives for both original equipment purchases and payback associated with high efficiency heating systems and the affordability of non-condensing equipment. r ate tw Ho pply Su r ate tw Ho turn Re Models Thermal Efficiency RLN-750* RLN-1000* RLN-1500* RLN-2000* 86.1% 86.2% 86.3% 86.5%

SPECIFICATIONS AND DIMENSIONS NOTE: Venting for the Reliance is standard Category IV (AL294C) with option for Category I (B-Vent) A D J I H E B F G Front View C Right Side View Specifications Models RLN-750 RLN-1000 RLN-1500 RLN-2000 Fuel Type Natural Gas or Propane NG & P NG & P NG & P NG & P Input BTU/Hr Maximum 750,000 1,000,000 1,500,000 2,000,000 Minimum 150,000 200,000 300,000 400,000 Electrical Requirements (Amps) 120V/60/1 <3 <3 <6 <6 Electrical Requirements (Amps) 240V/60/3 N/A N/A N/A N/A Water Content Gal 3 3 7.3 7.3 Dry Weight LB 700 700 1000 1000 Operating Weight LB 725 725 1060 1060 Dimensions RLN-750 RLN-1000 RLN-1500 RLN-2000 A. Boiler Width IN 24 24 32.125 32.125 B. Boiler Height IN 50.7 50.7 67.9 67.9 C. Boiler Depth IN 29.3 29.3 34.3 34.3 D. Boiler Depth with Trim IN 43.9 43.9 49.3 49.3 E. Air Inlet Diameter IN 6 6 8 8 F. Flue Outlet Diameter IN 6 6 8 8 G. Water Inlet/Outlet Diameter IN 2 2 2.5 2.5 H. Min Clearance to Walls IN 1 1 1 1 I. Min Clearance to Front and Rear IN 36 36 36 36 J. Min Clearance to Ceiling IN 24 24 24 24 * Specifications and Dimensions are approximate and for reference only. We reserve the right to change specifications and/or dimensions without notice. * Consult factory for availability of specific models. * Please consult factory for a complete list of dimensions including metric conversions. * Graphics contained in this brochure may not be representative of actual product.

APPLICATIONS ENGINEERED SYSTEMS Fulton s engineering and design capabilities are unmatched in the industry when it comes to providing comprehensive solutions to custom-designed hydronic systems. Our team of engineers and project managers assists in the specification and design of a turnkey system for each application. Skid-mounted hydronic systems provide simplified installation with single-point water, fuel and electrical connections available. From design to complete fabrication, trust Fulton and our many years of experience to build a system you can rely on for years to come. Our Engineering and Drafting group develops a 3-D CAD drawing package that details the Hydronic System components and their orientation on the skid. Fulton Heating Solutions, Inc. 972 Centerville Road, Pulaski, NY 13142 Call: (315) 298-5121 www.fulton.com The heat transfer innovators. /Fulton-Companies /FultonBoiler @FultonBoiler RELIANCE-bro-2013-0522