Resolving Security Issues When Working with the R&S FSUP in Secure Areas



Similar documents
Contents. 1 Overview. R&S FSQ - Instrument Security

Resolving Security Issues When Working with the R&S ESU in Secure Areas

R&S FSVA/FSV Signal and Spectrum Analyzer Instrument Security Procedures

R&S FSWP Phase Noise Analyzer Instrument Security Procedures

R&S FPS Signal and Spectrum Analyzer Instrument Security Procedures

R&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas

R&S ESW EMI Test Receiver Instrument Security Procedures

Resolving Security Issues when working with R&S UPV, R&S UPV66, R&S UPP200, R&S UPP400, R&S UPP800 in Secure Areas

USB Write Protection Utility

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note

Remote Monitoring and Control of the R&S FSV with a Web Browser

Remote Monitoring and Control of the R&S FSL with a Web Browser

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

Agilent Technologies Truevolt Series Digital Multimeters

CSCA0201 FUNDAMENTALS OF COMPUTING. Chapter 5 Storage Devices

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Firmware Release 4.42 SP2 (XP)

ConnectKey 2.0 WorkCentre 6655i 6655

Rohde & Schwarz Service that adds value

and Measurement Software

R&S VISA Release Notes Software Version 5.5.4

BIOS and CMOS. Overview. The Function of BIOS. The Bus

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

Handout 17. by Dr Sheikh Sharif Iqbal. Memory Unit and Read Only Memories

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

Broadcast Drive Test Software

Chapter 4 System Unit Components. Discovering Computers Your Interactive Guide to the Digital World

3.1 Backup and Recovery System

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Shearwater Research Dive Computer Software Manual

With respect to the way of data access we can classify memories as:

Release Notes. Contents. Release Purpose. Platform Compatibility. Licensing on the SRA Appliances and Virtual Appliance

Transfer of Trace Data From R&S Network Analyzer ZVx To Microsoft Excel

Discovering Computers Living in a Digital World

Common Operating-System Components

Computers. Hardware. The Central Processing Unit (CPU) CMPT 125: Lecture 1: Understanding the Computer

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

Logical Operations. Control Unit. Contents. Arithmetic Operations. Objectives. The Central Processing Unit: Arithmetic / Logic Unit.

ADVANCED PROCESSOR ARCHITECTURES AND MEMORY ORGANISATION Lesson-17: Memory organisation, and types of memory

Memory Basics. SRAM/DRAM Basics

Unified Utility Manual Label Printer. Rev. 2.08

Computer Components Study Guide. The Case or System Box

Chapter 6. Inside the System Unit. What You Will Learn... Computers Are Your Future. What You Will Learn... Describing Hardware Performance

Using AORUS Notebook for the First Time

Huawei E169 & E220 Status Lights

PLEASE TAKE GOOD CARE OF THIS DVD, we are under no obligation and in some cases unable to provide replacement copies of this Restore DVD.

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

/ Rev. 0 / Quick Guide for FDT Basic-Tool and Backup-Tool P40-SERIES

MARTECH SPI Tools. MARTECH SPI Tools User Manual v1.0. User Manual

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization

Benefits of a Colter OEM design / Embeded PLC

USING USB FLASH DISK WITH TCMS V2

A+ Unit Two: Hardware Basics

Lizard Standalone Mode Guide Version 1.0:

M2GO & M1 Operating System Installation

TAB Number: TB Temporary Solution for Ghost Operation failing on Intellex Ultra v4.3 Date Issued: 13 July, 2010

Remote Operation of R&S Instruments Using Remote Desktop Connection via LAN

NIVEO Network Attached Storage Series NNAS-D5 NNAS-R4. More information:

Instrument Software Update Instructions

EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0

USB 2.0 Flash Drive User Manual

DataTraveler Secure - Privacy Edition

Tutorial for MPLAB Starter Kit for PIC18F

FLASH USB Introduction ENGLISH

WinCON8000-R2/R8. Hardware User s Manual

ReadyNAS OS 6 Desktop Storage Systems

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

1. Introduction... 3 Introduction Deal command... 13

HP VMware ESXi 5.0 and Updates Getting Started Guide

R&S FS-K130PC Distortion Analysis Software Specifications

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Chapter 8 Memory Units

ENTTEC Pixie Driver API Specification

Sprint 3G/4G Plug-in-Connect USB Web Browser Interface User Guide

Digi Connect Wan 3G Application Guide Update the firmware, backup and restore the configuration of a Digi Connect Wan 3G using a USB flash drive.

Spectra T50e Flash (SD) Card Installation Instructions

SYSTEM BOARD D1107 ADDITIONAL TECHNICAL MANUAL

EUCIP - IT Administrator. Module 1 - PC Hardware. Version 2.0

What is LOG Storm and what is it useful for?

R&S ZNC Vector Network Analyzer Specifications

IBM Europe Announcement ZG , dated March 11, 2008

LandAirSea Tracking Key READ THIS BEFORE USING THE LANDAIRSEA TRACKING KEY

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

T3 Mux M13 Multiplexer

Chapter 3: Operating-System Structures. System Components Operating System Services System Calls System Programs System Structure Virtual Machines

EXTERNAL STORAGE WHAT IS IT? WHY USE IT? WHAT TYPES ARE AVAILBLE? MY CLOUD OR THEIR CLOUD? PERSONAL CLOUD SETUP COMMENTS ABOUT APPLE PRODUCTS

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

Fujitsu LifeBook S Series

DS2438EVKIT+ Smart Battery Monitor Evaluation Kit

85MIV2 / 85MIV2-L -- Components Locations

PDA Software Manual For the Windows CE and Mobile Operating Systems

PHOTO BANK BACKUP DEVICE

Network Attached Storage System Recovery Procedure

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

R&S RNMS3000 Radio Network Management System Utilization planning, radio network configuration and data distribution

Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual

Operating instructions TSE Wireless Software Home

Transcription:

Products: R&S Signal Source Analyzer FSUP Resolving Security Issues When Working with the R&S FSUP in Secure Areas Based upon the user s security requirements, this document describes the Rohde&Schwarz options available to address the user s signal source analysis needs. It also covers the different memory types and locations where user information can be stored in the signal source analyzer R&S FSUP. For secure environments, it describes an approach to physically remove the user data from the signal source analyzer. 1171.5702.52-01 1 Jochen Wolle-04/2007

Contents 1 OVERVIEW... 2 2 INSTRUMENT MODELS COVERED... 3 3 BATTERY INFORMATION... 3 4 TYPES OF MEMORY IN THE R&S FSUP SIGNAL SOURCE ANALYZER AND THEIR SECURITY CONCERNS... 3 5 INFORMATION STORAGE IN THE R&S FSUP SIGNAL SOURCE ANALYZER... 4 6 INFORMATION SECURITY IN HIGHLY SENSITIVE AREAS... 5 7 PERFORMING SERVICE, CALIBRATION AND MAINTENANCE ON THE R&S FSUP SIGNAL SOURCE ANALYZER... 5 8 PERFORMING FIRMWARE UPDATES AND BACKING-UP USER DATA IN SENSITIVE AREAS... 6 9 SPECIAL CONSIDERATIONS FOR USB PORTS... 7 10 ADDITIONAL INFORMATION... 8 1 Overview In many cases it is imperative that the R&S FSUP signal source analyzer be used in a secured environment. Generally these highly secured environments will not allow any test equipment to leave the area unless it can be proven that no user information will leave with the test equipment. Security concerns can arise when signal source analyzers need to leave a secured area to be calibrated or serviced. This document describes the types of memory and their usage in the R&S FSUP signal source analyzer. It also addresses methods of ensuring that no user data will leave the secured area should the product be removed for calibration or service needs. 1171.5702.52-01 2 E-1

2 Instrument Models Covered R&S Signal Source Analyzers R&S FSUP FSUP8 FSUP26 FSUP50 3 Battery Information There are no batteries in the R&S FSUP signal source analyzer other than the one on the CPU board used to power the clock in the chipset. 4 Types of Memory in the R&S FSUP Signal Source Analyzer and Their Security Concerns SDRAM The R&S FSUP signal source analyzer has 256 MByte of SDRAM on the CPU board. SDRAM is volatile memory and it loses its memory as soon as power is removed. The SDRAM will be unreadable within one minute after the power is removed from the instrument. The SDRAM is not a security concern. EEPROM Each board assembly in the R&S FSUP signal source analyzer has one serial EEPROM device. These devices hold 256 Bytes up to 32 kbyte and contain information related to the installed hardware, such as board serial number, options, correction constants, etc. The EEPROM does not hold user data nor can the user access the EEPROM storage. The EEPROM is not a security concern. FLASH The CPU board of the R&S FSUP signal source analyzer has one 512 kbyte flash memory device which contains the BIOS. The Flash memory does not hold user data nor can the user access the Flash memory. The Flash memory is not a security concern. 1171.5702.52-01 3 E-1

Removable Compact Flash Memory and Non-removable Hard Drive The R&S FSUP signal source analyzer can be equipped with either a Hard Drive or a Compact Flash Memory. The Hard Drive and Compact Flash Memory hold user data and are non-volatile. Hence, user data is not erased when power is removed from the instrument. The Hard Drive and the removable Compact Flash Memory should be treated differently with respect to security concerns.! The Compact Flash Memory is not a security concern because it can be removed from the instrument and left in the secure area.! The Hard Drive can still pose a security concern because it cannot be removed from the instrument. 5 Information Storage in the R&S FSUP Signal Source Analyzer DATA SDRA M Not a security concern EEPROM Not a security concern FLASH Not a security concern REMOVABLE COMPACT FLASH MEMORY Not a security Concern Temporary Information storage for the functionment of the CPU (CPU Cache, and Swap area) Hardware Info, Serial Number Product Options and Calibration Correction Constants BIOS Operating System and Instrument Firmware Instrument states, setups, Limit Lines and Transducer tables Trace data, Measurement Results and Screen Images 1171.5702.52-01 4 E-1

6 Information Security in Highly Sensitive Areas Since the SDRAM is erased when power is removed from the signal source analyzer it does not pose a security risk. No user data is written to the EEPROM and FLASH memories; hence, it is deemed that they do not pose a risk either. The REMOVABLE COMPACT FLASH MEMORY is the only device that does not lose its memory when power is removed and can contain user data. It can be removed from the signal source analyzer leaving the customer assured that no user data is stored within the signal source analyzer. The R&S FSUP signal source analyzer can be equipped with this option. The R&S FSUP signal source analyzer equipped with the REMOVABLE COMPACT FLASH MEMORY (Option FSUP-B18) address the needs of customers working in highly sensitive areas. 7 Performing Service, Calibration and Maintenance on the R&S FSUP Signal Source Analyzer R&S FSUP Signal source Analyzer equipped with the REMOVABLE COMPACT FLASH MEMORY Turn-off the signal source analyzer and remove the classified compact flash memory (with the user data). This removes all user data from the signal source analyzer. The signal source analyzer, without the removable compact flash memory, can now leave the secured area. Once the signal source analyzer is outside the secured area, installing a second nonclassified removable compact flash memory (without any user data), allows the signal source analyzer to function properly for service or other needs. Prior to re-entering the secured area, the non-classified removable compact flash memory (without the user data), is removed. When the signal source analyzer is back within the secured area, the original classified removable compact flash can be reinstalled. To hold classified user data in the secure areas, Rohde & Schwarz recommends the REMOVABLE COMPACT FLASH MEMORY Option FSUP-B18. To hold non-classified user data in the non-secure areas, Rohde & Schwarz recommends the REMOVABLE COMPACT FLASH MEMORY Option FSUP-B19. Calibration and the validity of the signal source analyzer's calibration after exchange of the REMOVABLE COMPACT FLASH MEMORY The calibration ensures a user that their measurements are traceable to a government standard. Rohde & Schwarz highly recommends that users follow the calibration cycle suggested for their instrument. The EEPROM is the only location used to hold permanent adjustment values required to maintain the validity of the signal source analyzer's 1171.5702.52-01 5 E-1

calibration. Hence, replacing one removable compact flash memory with another, does not affect the validity of the instrument s calibration. After an exchange of the removable compact flash memory, the board assembly EEPROMs need to be registered. This operation has to be executed once:! Turn the instrument Off! Turn the instrument back On while holding down the decimal point key [.] on the number keypad on the front panel! Continue to hold this key for 10 seconds after pressing the "On" button! The instrument will now recognize the changes and then power up It is only necessary to perform these steps the first time the signal source analyzer returns from the service. After an exchange of the removable compact flash memory, the selfalignment function has to be executed once. This is done with the CAL - CAL TOTAL function. This function uses the high-stability internal reference generator to produce the temporary adjustment values. Using the permanent and temporary values, the necessary adjustment information is then stored on the compact flash memory. Rohde & Schwarz recommends that users perform the self-alignment function on a weekly basis after the analyzer has had sufficient time to warm-up. 8 Performing Firmware Updates and Backing-Up User Data in Sensitive Areas Rohde & Schwarz highly recommends, but does not require, the users of its products, to maintain their products with the latest updates and to regularly back-up important user data that can be erased. Firmware updates are available from the R&S website. How does a user perform firmware updates and back-up user data in sensitive areas? There are several options available for the user to safely perform these operations without compromising the security of the sensitive areas. Via the USB port Rohde & Schwarz signal source analyzers are equipped with USB ports as standard equipment. The instrument firmware update can be performed directly from the USB stick. The USB stick can likewise hold or transport user data back-ups to an approved storage medium. As described below, users can disable the capability of the USB ports for saving data (set to "read only"). For users that have not elected to disable the USB ports for writing data a memory stick can be used for backing-up user data. Via the LAN interface The R&S FSUP signal source analyzer is equipped with a LAN interface as standard equipment. A user can transport the firmware update into the secure area via a CD or another medium that meets the security requirements. The update can then be placed on a system on the LAN within the secure area. The signal source analyzer can be updated directly from the LAN. The LAN can likewise be used to back-up user data to an approved storage medium. 1171.5702.52-01 6 E-1

9 Special Considerations for USB ports USB ports can pose a security threat in high-security locations. Generally, this threat comes from small USB pen drives (a.k.a. memory sticks, key drives, etc) which can be very easily concealed, yet can quickly read/write several GBytes of data. Disable USB Ports for Writing User Data The R&S FSUP signal source analyzer can be updated with an utility to disable the write capability on any USB Port for storage devices. This utility is available from Rohde & Schwarz FSUP web site w/o any charge. To disable the write capability copy the utility software to the signal source analyzer and run it once. After reboot of the instrument the write capability on any USB memory device is disabled. 1171.5702.52-01 7 E-1

Additional Information Please contact your support center for comments and further suggestions: Hotline Europe Telephone: +49 180 512 4242 Fax: +49 89 4129 63778 Internet: Contact us Hotline America Telephone:1-888-TESTRSA (1-888-837-8772) selection 2 From outside the USA: +1-410-910-7988 Email: customer.support@rsa.rohde-schwarz.com Hotline Asia Telephone: +65 6846 3716 (9am-6pm, Mon-Fri, excluding Public Holiday) Fax: +65 6846-0029 E-mail: info@rssg.rohde-schwarz.com ROHDE & SCHWARZ GmbH & Co. KG. Mühldorfstraße 15. D-81671 München. P.O.B 80 14 69. D-81614 München. Telephone +49 89 4129-0. Fax +49 89 4129-13777. Internet: http://www.rohde-schwarz.com 1171.5702.52-01 8 E-1