Industrial Strength Leak Detection



Similar documents
TraceTek. Leak Detection and Location Systems FIND LEAKS BEFORE THEY FIND YOU

WATER LEAK DETECTION FIND LEAKS BEFORE THEY FIND YOU

water leak detection

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Underground Storage Tanks

Process Alarm Solutions

LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

Reliability Accuracy Performance

Tank Gauging & Inventory Management Solutions

LEAK DETECTION ALARM SYSTEM GUIDELINES FOR TOXIC HAZARDOUS/MATERIALS STORAGE

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

Advantium 2 Plus Alarm

Manual for Fire Suppression & Methane Detection System

Leak Detection System

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Interface Level And Point Level Analyzers & Sensors

Series 510 Submersible Level Transmitters

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

UST RULES CHANGES. Heather Peters, Environmental Specialist

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

InHome Water Leak Detection Package

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Models SFP33 & SFP32 Pressure Transmitters

Distributed Temperature Sensing - DTS

Process Instrumentation

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Heat Tracing is the use of an externally applied heat source to a pipeline to compensate for heat losses through the thermal insulation.

Telemetry system for cathodic protection equipment of underground metal pipelines

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Modbus Tutorial 7/30/01. Tutorial on TTDM-PLUS and TTSIM System Integration using Modbus

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

N4385A / N4386A Distributed Temperature System (DTS)

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Integrated Custom Systems

Electric Water Heater

Electronic Flow Switches

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Streaming Potential System (SPT1000, SPD1000)

Introduction To SCADA and Telemetry

Improving SCADA Operations Using Wireless Instrumentation

Regulations and Recommended Practices. Introduction. American Petroleum Institute Recommended Practices 2350

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

DRAFT REVISED Musts For USTs DRAFT. Printed on Recycled Paper. Updated June 2015

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

Schneider Electric s Advanced Water Leakage Detection

Wireless Indoor/ Outdoor Thermometer

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Water Leak Detection System

Complete SCADA solution for Remote Monitoring and Control

i ChatterBox! Motorcycle Security

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Diesel Engine Driven Generators Page 1 of 6

Spill Control Prevention Plan (SCPP)

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT


Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Unidirectional Transmitter/ Receiver Units Introduction

Industrial Control Solutions

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan

In-Line Fluid Monitoring Packages

Float & Tape Tank Gauging Solutions for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory-Grade Level Measurement

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

Compliance Guidance for Motor Vehicle Waste Disposal Wells in Oregon September 2015

Secondary Containment: Regulations & BMPs. Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com

About us. Eugensa is an ISO 9001:2008 certified company. CERT

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

How Your Vehicle Service Facility Can Prevent Stormwater Pollution

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CHAPTER PETROLEUM CONTACT WATER

Cosasco Wireless System

TMS TANK MANAGEMENT SYSTEM

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

METERS Data Collection CONTROL. Dialog3G. AMR/AMI Solutions

UNIVERSITY OF WISCONSIN MADISON

COOLING WATER MANAGEMENT

Wireless solutions for water and wastewater management

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Delta Transportation Automation Solution.

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

Transcription:

Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation...

TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensors suited to the task TT3000 for acids, bases and other hazardous fluids with water content TT5000 for gasoline, jet fuel, diesel, crude oil, lube oil and other hydrocarbon based liquids TT5001 for organic solvents TT7000 for strong acids and bases TT-FFS for fast detection of gasoline, jet fuel, diesel, crude oil, lube oil and other hydrocarbon based liquids Detect a spill, locate the source of the leak and take corrective action before an incident becomes a news story. The key is quick detection and accurate location at the source of the leak. TraceTek sensor cable and monitoring systems make it possible. If your business involves the transportation, storage, processing or consumption of hazardous fluids, the possibility of a leak must be considered. Whether your concern is gasoline, jet fuel, diesel, crude oil, acids, bases, contaminated water or any other hazardous liquid, TraceTek can provide a leak detection system tailored to your needs. TraceTek leak detection systems can detect and pinpoint the source of a leak to help you take decisive action long before the spill can ruin your reputation. Reliability Simple detection and location circuit Radiation cross-linked, fluoropolymer materials No exposed metal parts Tens of thousands of installations worldwide in virtually every type of environment Easy installation, simple maintenance Simple, easy to understand alarm panel No field calibration required Self-monitoring for damaged or broken cable Easy to extend or modify in the future Accurate leak location The entire cable is a sensor Leaks are reported to the nearest foot or meter with better than 0.1% precision Instrumentation flexibility Small area, single channel monitoring with relay output Long-length cable monitoring with precise leak location reporting Single circuit / multiple circuit options Alpha numeric user interface Output to host systems via relay contacts or serial data ports (Modbus or Johnson Controls Metasys format) Multiple circuit capability A single circuit can be as short as 1 meter or as long as 1500 meters TTDM-128 Alarm Panel can monitor a single circuit or up to 128 circuits

TraceTek Leak Detection Systems can operate as stand-alone independent alarm systems or they can easily be integrated with: SCADA system Factory Automation Systems Building Management Systems Distributed Control Systems Programmable Logic Controllers A TraceTek Leak Detection System consists of Sensor Cable, Probes, Sensor Interface Modules and Alarm Panels. Additional sensor options include: float switches, pressure switches or any other sensor device that can provide a contact closure. Instrumentation options include: low voltage / relay contact devices, instruments for hazardous locations, battery powered flashing light indicators, and other options tailored to the application. 1

TraceTek Cable: Direct buried applications: Leak Detection and Monitoring for: single wall fuel pipe above ground storage tanks buried valves and fittings above ground piping TT5000 Fuel Sensor Cable is used to monitor the soil under and around fuel carrying pipes and tanks. The TraceTek system detects and reports the location of a fuel spill before major damage can occur. Leakage rates far below the threshold of a SCADA (Supervisory Control and Data Acquisition) leak detection system can be detected while contaminated soil is still measured in a few cubic meters rather than truckloads. Jet fuel transfer line with blue PVC slotted conduit for TT5000 installed at a major international airport. TT5000 Sensor Cable in PVC conduit can be positioned below buried valves or beneath Aboveground Storage Tank bottoms. The TraceTek system reports the location of a leak to an accuracy of ± 1 meter along the length of a pipeline or beneath a tank floor. The slotted PVC conduit allows the sensor cable to easily be removed and inspected for simple and direct verification of a leak before digging. Detect and locate a leak before damaging the aquifer! 1 hour 4 hour 10 hour 20 hour Above, typical progression of an 8 liter per hour leak The intention is to detect a leak when the affected area is still small and easy to clean up, with a minimum of environmental damage. 2

Interstitial and Indoor applications: Interstitial monitoring for double wall pipe. Indoor monitoring under raised floors, for chemical supply and return piping and other hazardous fluid leak detection. TraceTek 3000 sensor cable is designed to detect waste water, acids, bases, or any liquid that is conductive. Rapid detection, accurate location reporting and excellent chemical resistance make TT3000 a popular choice for double containment pipe systems. TraceTek 5000 is the sensor of choice for fuel piping and underground storage tanks. TraceTek 5000 detects fuel but ignores water. Branch connectors simplify tracing complex manifolds and hydrant systems. Every meter of cable has a unique address so that leaks are detected where they start and repairs can be accurately directed. TT-FFS probes can detect fuel floating on water in sumps and bermed containment areas. Wherever complex piping, hazardous chemicals and critical working environments come together, a system to monitor for fluid leakage becomes critical. TraceTek cable and probes provide the flexibility to monitor long runs of pipe or a single valve box where visual inspection is difficult or impossible. Precise location reporting assists in rapid and accurate dispatch of emergency response teams. TT3000 (for conductive liquids) and TT5001 (for organic solvents) are used to monitor the chemical supply systems in semi-conductor manufacturing facilities, pharmaceutical plants, and similar high-value facilities that demand excellent environmental monitoring. 3

TraceTek Technology: TraceTek Technology and System Components TraceTek Sensor Cables are made with materials that have excellent chemical resistance. The TT3000 sensor cable uses conductive polymer-coated wires separated by the solid Kynar insulated core. TT3000 is quick to reset when removed from a spill because the solid core resists accumulation of liquids and contaminants. TT3000 sensor cable detects conductive liquids such as waste water, acids, bases, cooling water etc. TT7000-HUV sensor cable is similar to TT3000, but is sensitive only to strong acids and not water. It is protected from ultra violet radiation for outdoor installation. TT5000 sensor cable is designed to detect and locate liquid hydrocarbon fuel spills. The material properties of the core and jacket materials allow the cable to detect and locate liquid fuels such as gasoline, jet fuel and diesel while at the same time completely ignoring water. TT5001 sensor cable is similar to TT5000, but is sensitive to organic solvents. TT-FFS Fast Fuel Sensor is a fast acting probe designed to detect hydrocarbon fuel floating on water, spreading on a flat surface or collecting in a sump. TT3000 TT7000-HUV TT5000 TTDM-128 Alarm Panel can act as a stand alone leak detection control panel or as the display and user interface for a multiple circuit network of leak detection circuits. TTSIM Sensor Interface Modules are the key components of multiple circuit leak detection networks. Leak detection information and cable status is digitized and transmitted to a TTDM-128 panel for display or directly transmitted to Factory Automation Systems, PLC s, DCS etc. TTSIM-2 is a good choice for monitoring a small area. TTDM-128 TTSIM-1 TTSIM-2 TT-FFS 4

System integration and telemetry options: Relay Contacts TraceTek instruments are available with leak alarm and trouble contacts for signaling a host system. Serial Data Port TTDM-128 and TTSIM offer full data access via the Modbus (J-Bus) protocol. TTDM-128 has a user selectable RS232 or RS485 serial port. TTSIM is RS485 only. Telemetry The standard connection method between TTDM- 128 and TTSIM s is twisted-pair copper wire. When network distances increase beyond 1200 meters there are other options available including: fiber optics, and spread spectrum radios. For a single small area, a TTSIM-1A can provide relay contact output to a PLC or building management system. The combination of sensor cable and a TTSIM-1A makes an effective drip tray monitoring system. Knowing the leak location is important when the size of the monitored area gets larger and when the sensor cable is concealed by walls or raised floors. TTDM-128 and the TraceTek sensor cable provide excellent detection and location performance with accuracy to 1 meter. For clean rooms and similar building applications a single TTDM-128 alarm panel can monitor the entire facility for hazardous liquid spills. Here several TTSIM units are monitoring specific areas while the TTDM-128 monitors the entire network. TT5000 can be installed along a buried pipeline using a cluster of 4 TTSIM units mounted in a single enclosure. Power points are required approximately every 5 to 6 kilometers. 5

TraceTek and Tyco Thermal Controls The TraceTek Leak Detection and Locating System was developed by Raychem Corporation in the mid 1980s. The TraceTek Products Group became part of Tyco Thermal Controls when Raychem Corporation was aquired by Tyco International in 1999. Tens of thousands of TraceTek systems have been installed over the years in a variety of leak detection applications ranging from water detection in commercial buildings to hazardous fluid monitoring to leak detection for fuel storage and transportation systems. The versatility of the TraceTek technology lends itself to customized designs that detect and locate liquid leaks and spills before equipment or environmental damage becomes significant. Whether it s a matter of personnel safety, the need for 24/7 reliability, or avoiding expensive environmental clean-up costs and penalties, the TraceTek system can be a key element of your facility operating and security systems. Tyco Thermal Controls is an ISO 9001 Certified Development and Manufacturing Facility with sales and support operations in over 40 countries around the world. Distributed By: For more information see: www.tracetek.com www.tycothermal.com U.S.A. Tyco Thermal Controls 2415 Bay Road Redwood City, CA 94063-3032 USA Tel: (800) 545-6258 Fax: (650) 474-7215 Europe Tyco Thermal Controls Staatsbaan 4A 3210 Lubbeek Belgium Tel: (32) 16/213-571 Fax: (32) 16/213-600 Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. Tyco and TraceTek are trademarks or registered trademarks of Tyco Thermal Controls LLC or its affiliates. Asia Tyco Thermal Controls 10//F, New China Insurance Tower, A12 JianGuoMenWai Avenue Chao Yang District Beijing 100022 P.R. China Tel: 86 (10) 65693200-8501 Fax: 86 (10) 65693203 Modbus is a registered trademark of Schneider Automation Inc. METASYS is a trademark of Johnson Controls, Inc. KYNAR is a registered trademark of Atofina. 2007 Tyco Thermal Controls LLC Printed in USA H57065 11/07 Printed on recycled paper