QFP910. Water detector. Building Technologies. CE1N2732en. Synco living



Similar documents
QFP910. Water detector. Building Technologies. CE1N2732en Synco living

RRV934. Multi-controller. Synco living

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

IN-OUT Thermometer with Cable Free Sensor and Clock

HCR3.2/.. Chipcard reader HOTEL SOLUTION

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

OZW30. Central Unit SYNERGYR

Flush-mount room temperature sensor AQR2531ANW.

Digital input modules

Drayton Digistat +2RF/+3RF

Room Temperature Sensors

OZS Web server. For LPB/BSB plants

Transmitter Actuator 230V wave UP 560. Operation

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TX OPEN RS232/485 module

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RS 110 II. Quick Guide Consignes de sécurité Indicaciones de seguridad Guia de Segurança Sicherheitshinweise Guida per la sicurezza Veiligheidsgids

GREISINGER electronic GmbH

Air damper actuators

OZW V2.0. Web server. Synco TM, Synco TM living

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

evohome Wireless Radiator Zoning Kit Installation & User Guide

REMOTE TERMOMETER TE 219 LED USER MANUAL

HVAC central apartment unit with consumption data acquisition

Input module, input/output module

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Rousseau 10. User Guide

T0118 T2118 T3118. Instruction Manual

VAV compact controller KNX / PL-Link

Getting started with

Infrarot-Bewegungsmelder IP44

Product and Application Description

VAV compact controller KNX / PL-Link

Duct Humidity Transmitter

AXIS 291 1U Video Server Rack Installation Guide

WEATHER STATION Instruction Manual Cat. No IT

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Instruction Manual. T3111 T3111L T3111P T3111Ex

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

HERZ-Thermal Actuators

KNX Gateway RGK E-01

Stove Guard Kit User Manual

BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No IT

Wireless Indoor/ Outdoor Thermometer

WIRELESS WATER LEAK DETECTOR

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Digital inductive conductivity transmitter

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

FMT600BT Transmitter

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Waveguide Access Point WGA631. Product Guide

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Installation Guide. DEVIreg 530. Electronic Thermostat.

ST815 Illumination Sensor with LCD

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

OZW V4.0. Web server. For Synco TM, Synco TM living

WIRELESS MAGNETIC CONTACT

Atomic Projection Alarm with Indoor and Outdoor Temperature

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

500r+ Installation and User Guide

WIRELESS STATUS MONITOR

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

TS93 EMR T/PT/TDE. Surface applied door closer

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

FIRE DETECTION AND ALARM SYSTEMS

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Rosemount 333 HART Tri-Loop

Intruder Alarm System

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Danfoss Link Mobile Phone Butler

720r Addendum: Siting the 720r

Product and functional description

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

IAdea GPIO Extender Application Note

Cross-beam scanning system to detect slim objects. 100 mm in

Remote Monitoring and REC 501 Control Unit Product Guide

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

Rosemount 333 HART Tri-Loop

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

HVAC central apartment unit with consumption data acquisition

USB/RS485 converter cable, complete

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

Distress alert system. User Manual DAS1100

Antenna Splitter ASA 1. Instruction manual

Transcription:

2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use Integrates into Siemens system Synco living Records water puddles in wet rooms, e.g. kitchens, bathrooms, laundry rooms, etc. Allows the following actions depending on how the central apartment unit is configured: Automatically close the shutoff valve for the main line Activate interior siren Sends an alarm via web on a PC or cell phone Deployed especially for: The renovation market (old buildings, museums, churches, historical buildings, etc.) Difficult wall mounting (sandstone, glass, etc.) New buildings CE1N2732en 18.05.2010 Building Technologies

Equipment combinations The QFP910 can be used together with the Siemens System Synco living. Detailed information on the device combinations is available in the data sheet for the central apartment unit. Ordering When ordering, please specify the quantity, product name, and type code. Delivery The QFP910 consists of a water sensor and a radio transmitter. Each QFP910 is delivered with alkaline batteries, mounting materials and mounting instructions. Order numbers Type Stock number Name QFP910 S55371-C100 Water detector with installation instructions Product documentation Operating and commissioning instructions for the QFP910 are included in the product documentation for the central apartment unit. Functions Main function Binding Status request RF binding test Error messages / Maintenance messages During normal operation, the QFP910 sends periodically, or for change its status (dry / water leak), to the central apartment unit. It interprets a "water leak" if the water sensor resistance drops below the lower limit value and the corresponding message is sent to the central apartment unit. The status for the QFP910 returns to "dry" if the resistance returns above the upper limit value and a corresponding message is once again sent to the central apartment unit. The state "water leak" is sent at one-minute intervals. The state "dry" is sent at 15-minute intervals. Binding logs the QFP910 on to the central apartment unit and thus integrates it into the radio system. The function button triggers the binding process. The function LED signals the process. The function button can query the battery level. The function LED signals the battery level. It is also sent in each telegram to the central apartment unit. The function button can trigger a binding test. This checks the radio link to the central apartment unit. The function LED signals the RF binding test. The maintenance message (batteries low) is forwarded to the central apartment unit and displayed there. The water sensor cannot be checked for short circuits or interrupts. As a consequence, there are no error messages for a short circuit or sensor interrupt. 2 / 8

The QFP910 generates the following messages: Error messages None Maintenance message Batteries low (battery life 3 months) Operating and display elements Function LED Function button Overview of display and operating element functions on the QFP910: Function LED Battery level Binding process Function button Battery query Binding RF binding test Additional information on the function and operation of the QFP910 is available in the product documentation for the central apartment unit. Notes on engineering and operation Mounting location for water sensor Mount the water sensor in the building where there is water. The water sensor should be installed as close as possible to any potential water leak, e.g. in the laundry room, close to the washer or in the kitchen below the sink connections or input/output on the dish washer. The water sensor should be mounted on the wall at the lowest point so that the two contacts nearly touch the floor. The floor under the water sensor should be horizontal and even. 2732Z03 Observe permissible ambient conditions. The water sensor should not be located in water puddles for longer periods as this reduces battery life for the radio components. 3 / 8

RF Transmitter mounting location Mount the RF transmitter in the building. Mount it close to the water sensor at a maximum of 1.8 meters above it (water sensor cable length = 2 meters). Do not expose to drips and permissible ambient conditions must be maintained. Notes on engineering and mounting RF devices for the Siemens system Synco living are available in the communications data sheet CE1N2708en. Mount the RF transmitter's wall base on a flat wall. Maintain a minimum distance of 60 mm from the bottom to open the battery compartment. 60 2701Z03 Mount Note Mount the RF transmitter using a base on the wall. The RF transmitter can be mounted in most off-the-shelf recessed conduit boxes or directly on the wall. First mount the water sensor and then the RF transmitter. Then connect the water sensor to the RF transmitter. Only then insert the batteries in the RF transmitter. Commissioning Maintenance / Change battery Prior to commissioning, check whether the water sensor is professionally installed at the recommended location and in the proper position on the wall. Further, check whether the connecting cable is professionally connected to the corresponding terminals on the RF transmitter and whether functioning batteries are properly inserted in the RF transmitter. The QFP910 is maintenance free. The system reports when a change of batteries is required. The batteries are located under the cover for the battery compartment. No tools are required and batteries can be changed in a mounted device (reverse battery protection). You may have to clean the contact surfaces on the water sensor with a moist towel after the water detector reacts and the water puddle is dried out. It may trigger a "water leak" message. The message must then be acknowledged on the central apartment unit. 4 / 8

Disposal The QFP910 is considered electronics device for disposal in terms of European Directive 2002/96/EG (WEEE) and may not be disposed of as domestic garbage. Comply with all relevant national and statutory regulations. Dispose of the device via the proper channels. Observe all local and applicable laws. Dispose of used batteries at the collection locations provided. Warranty Technical data relating to applications are guaranteed solely together with the Siemens Synco living system. Device combinations are available in the data sheet for the central apartment unit. The user ensures the functionality of operation for the QFP910 when using thirdparty devices. Siemens does not provide service or guarantee services in this case. 5 / 8

Technical data QFP910 Water sensor Water sensor Cable length Detector response time 2 m 2 seconds Technical data QFP910 RF transmitter Power supply Battery type Battery life (capacity 2.5 Ah) 2 x alkaline batteries LR6 (AA); 1.5 V 3 years (in "dry" state) RF Radio Frequency RF Range RF protocol 868 MHz, unidirectional Typically 30 meters inside building KNX RF compatible Electrical connection Screw terminals for cross-section of Cable length 0.1 1.5 mm 2 (connections interchangeable) Max. 10 meters Standards Conformity to EMC directive - Immunity to interference, emissions Low voltage directive - Electrical safety RTTE (Radio & Telecom. Equipment - Radio communications 2004/108/EC - EN 60730-1 2006/95/EC - EN 60730-1 1999/5/EC - EN 300220-2, EN 301489-1, EN 301489-3 Degree of protection Environmental compatibility Protection class III as per EN 60730 Housing IP40 2) as per EN 60529 Degree of pollution 2 as per EN 60730 The product environmental declaration CE1E2732en contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) RL 2002/95/EC (RoHS) Dimensions Weight Housing material Housing color Device packaged with inserts 2) Fully mounted Refer to dimensions 0.28 kg Plastic ASA+PC White NCS S 0502-G Ambient conditions Operation EN60721-3-3 Transport EN60721-3-2 Storage EN60721-3-1 Environmental conditions Class 3K5 Class 2K3 Class 1K3 Temperature 0 +50 C -25 +70 C -20 +65 C Humidity 5 95 % r.h. <95 % r.h. 5 95 % r.h. (non-condensing) Mechanical conditions Class 3M2 Class 2M2 Class 1M2 Maximum elevation above sea level Min. 700 hpa corresponds to a maximum of 3,000 meters above sea level 6 / 8

Connection diagram Water sensor A Connections are interchangeable RF transmitter Dimensions Dimensions in mm Water sensor 46 3,4 30 12 2000 8 2732M01 RF Transmitter 22 mm 1 mm 84 mm 2701M01a 42 42 28 28 TOP 42 2702M01 76 mm 84 mm 28 28 12 4,2 30 30 42 30 30 7 / 8

8 / 8 2010 Siemens Switzerland Ltd Subject to change