RADIATION MONITORING SYSTEMS



Similar documents
SafePoint RMS. Sustainable Committed Secure. SafePoint. Monitoring Solutions

In a typical light water reactor (LWR) the Radiation Monitoring System (RMS) comprises three major groups. These are:

Radiation Monitoring System RMS

Boiling Water Reactor Systems

Radiological Assessment Display and Control System

How To Clean Up A Reactor Water Cleanup

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

Integrated Custom Systems

C-10 Radiation Monitoring Network

Cyber Security Design Methodology for Nuclear Power Control & Protection Systems. By Majed Al Breiki Senior Instrumentation & Control Manager (ENEC)

Ammonia Detection System Codes and Design Specifications

NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1. Renewed License No. NPF-63

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

WordPerfect Document Compare Summary

Combined Cycle Control Overview

11. Radioactive Waste Management AP1000 Design Control Document

DOE-HDBK Module 2.18 Air Sampling Equipment. Instructor s Guide

S300 Series Dust Monitors

Interface Level And Point Level Analyzers & Sensors

How To Use A Ds340 (Dsp)

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1]

On-line Dissolved Gas Analysis

HOW DOES A NUCLEAR POWER PLANT WORK?

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

RGC-IR Remote Gas Calibrator for IR400

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN OFFICE OF NUCLEAR REACTOR REGULATION

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Arc Terminator Active Arc-Resistant Switchgear

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Agile Project Execution

SECTION FIRE ALARM AND DETECTION SYSTEMS

Micro Motion Net Oil Computer Software and NOC System

TABLE OF CONTENT

The Unique Accelabar Flow Meter

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

LyoBeta. R+D Freeze-Dryers

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and

notes MERRTT IS-302 Radiological Survey Instruments and Dosimetry Devices

HEAVY WATER LEAK DETECTOR

AN APPLICATION STUDY FOR THE CLASS IE DIGITAL CONTROL AND

Source Term Determination Methods of the Slovenian Nuclear Safety Administration Emergency Response Team

Digital inductive conductivity transmitter

Captus 3000 Thyroid Uptake And Well System

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Take total control of your HVAC system with cost-saving flow and thermal energy meters

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

RADIATION THERAPY. Dosimetry Pioneers since 1922 NEW

NRC INSPECTION MANUAL INSPECTION PROCEDURE 88045

Steven A. Arndt Division of Engineering Office of Nuclear Reactor Regulation

Smart. Scalable. Simple.

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

API Marine. BMS Presentation. Ballast Measurement Systems

G64 Area Gamma Monitor

A Practical Guide to Free Energy Devices

Introductions: Dr. Stephen P. Schultz

The Ambient Air Monitoring System

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Combustion Dynamics Instrumentation

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Intelligent Vibration Monitoring

Alain Nifenecker - General Electric Manager Controls Engineering

1.0 What Are the Purpose and Applicability of Performance Specification 11?

Application of FPGA-based Safety Controller for Implementation of NPPs I&C Systems Vladimir Sklyar, Technical Director

Perimeter Security System

REAL-TIME DUST AND AEROSOL MONITORING

Tank Gauging & Inventory Management Solutions

Remote Monitoring and REC 501 Control Unit Product Guide

Ultrasound Condition Monitoring

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

EMERGENCY PREPAREDNESS FREQUENTLY ASKED QUESTION (EPFAQ) NEI REVISIONS 4 THROUGH 6; NUMARC/NESP 007

Three Myths of the Three Mile Island Accident

RECOMMENDED SPECIFICATION. Cogent Environmental OVA-5000 Heavy Metal Analyzer. to Monitor Total Dissolved Arsenic. for

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Rittal Liquid Cooling Series

Fiber Optic Distributed Temperature Sensor (B-DTS)

REAL TIME LABORATORY MONITORING SYSTEM

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE 4.15 (Draft was issued as DG-4010, dated November 2006)

NETWORK ENABLED EQUIPMENT MONITOR

How To Control A Medical Device With A Pc System

Sanitary Type Electronic Flow Switches

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Global Value 7. Productivity Suite for GammaVision. Optimizing Gamma Spectrometry Processes through Secure Data Management and Measurement Automation.

PI Chemistry - PI 24 HEAVY WATER LEAKAGE - DETECTION. 1. Name and briefly describe the operation of five of:

Selecting Sensors for Safety Instrumented Systems per IEC (ISA )

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Transcription:

RADIATION MONITORING SYSTEMS Area monitors Process monitors In-line, Adjacent-to-Line monitors Local/remote processors, Data Acquisition Systems NUPIC Certified, NRC Approved Vendor Wide Range Sensitivity Radiation Monitoring Systems for a Lifetime of Service GENERAL ATOMICS ELECTROMAGNETICS

RADIATION MONITORING SYSTEMS Nuclear power plants worldwide rely on the quality and dependability of General Atomics Electromagnetic Systems (GA-EMS) Radiation Monitoring Systems (RMS). GA-EMS has fielded and continuously supported qualified monitoring and detection systems, providing plant operators with unmatched reliability and performance to ensure safety while minimizing overall plant lifecycle costs. Since the first system installation in 1965, GA-EMS has provided customers with unwavering support and a commitment to keep our RMS systems running efficiently for the lifetime of the plant. Designed and manufactured in the U.S.A., our flexible designs are customizable to meet site-specific requirements for new plant builds and for retrofitting existing plant installations. GA-EMS radiation monitors are built with full qualifications and traceability, eliminating additional costs associated with qualification in place. We also provide diagnostic and system health monitoring capabilities to help operators keep system performance optimal. EFFLUENT FLOW DUCT SAMPLING SECTION ISOKINETIC SAMPLE PROBE SAMPLE RETURN COMMUNICATIONS LINE RM-2000 MICROPROCESSOR & CIJB RM-2300 CONTROL/DISPLAY LOW RANGE MID/HIGH RANGE GRAB SAMPLE CONTROL ASSEMBLY SAMPLE CONDITIONING SKID SAMPLE DETECTION SKID CONTROL ROOM CABINET

COMPLIANCE GA-EMS leads the industry in meeting safety and non-safety requirements with a Quality Assurance Program that fully complies with: 10CFR50, Appendix B ANSI N45.2, including applicable daughter standards ANSI/ASME NQA-1 (2008) and NQA-1a (2009) ISO 9001-2008 ISO 10 CFR 50 APPENDIX B ISO 9001:2008 NQA-1 QA PROGRAM NUPIC CERTIFIED NRC APPROVED VENDOR REGULATORY GUIDE 1.97 SAFETY RELATED, CLASS 1E GA-EMS has designed, manufactured, and fielded over 100 unique detectors. This brochure provides information on typical standard systems and parameters. We work closely with our customers to design and manufacture systems customized to suit specific plant requirements. Contact GA-EMS to discuss our range of capabilities and radiation monitoring systems to meet your unique specifications. CUSTOMER SUPPORT SERVICES We provide outstanding customer support and obsolescence mitigation to ensure each system is sustainable over a plant s entire operating lifecycle. Our support services, access to unmatched technology expertise, and extensive on- and off-site training help plant operators keep systems safely on-line, all the time. CAPABILITIES Complete Field Service Engineering Services Start-up Service Training Courses RMS User s Group and Conference

AREA MONITORS KEY FEATURES LOCA-qualified (Loss of Coolant Accident) Reg. Guide 1.97 Seismic IEEE 344 Environmental IEEE 323 Lead shield for process monitoring applications Digital High Range Area Monitors RD-14 Detector RD-2A Detector GA-EMS offers a variety of area monitors designed to continuously monitor gamma radiation for areas inside a nuclear power plant. Systems are configured to monitor low radiation ranges for the protection of plant personnel, as well as high radiation ranges to detect breaches in process stream or containment boundaries. GA-EMS area monitors feature Geiger-Mueller (G-M) tubes for low range gamma radiation detection and ionization chambers for high range gamma radiation detection. Extended range configurations are available to monitor ranges which overlap between the G-M tube region and ion-chamber region. GA-EMS microprocessor unit processes the detector signals, calculates activity data, displays data, transmits data to plant computer systems, and activates local and remote audible and visual alarms.

MODEL TYPE RANGE DESCRIPTION RD-2A, RD-2B Ionization Chamber 10-1 to 10 4 R/hr General high range area detector, or can be used to view a process line for measurement of radioactivity such as a hardened containment vent pipe. RD-8 Ionization Chamber 10-1 to 10 5 R/h Energy compensated high range area detector, LOCA qualified. RD-14 Low Range G-M Tube 10-3 to 10 4 mr/hr General area monitoring within the plant. RD-14 High Range G-M Tube 10-2 to 10 5 mr/hr General area monitoring within the plant or adjacent to line applications. RD-23 Ionization Chamber 10 0 to 10 8 R/hr Measures radiation level in the containment. Safety related R.G. 1.97 qualified for use in harsh environments and during a LOCA.

PROCESS MONITORS GA-EMS process radiation monitoring systems are designed to continuously detect and measure radioactivity in airborne and process gas, liquid and steam lines. Our custom and standard designs can accommodate specific applications and requirements within a nuclear power plant. All GA-EMS monitors are manufactured with the highest standards of quality in the industry, with full qualifications and traceability, eliminating additional costs associated with qualification in place. GA-EMS radiation monitors include local processors, remote indicators, and integrated systems to perform data acquisition, analysis and display, monitor control functions, alarm relays, analog outputs, and digital communications. System databases contain operation and calibration constants, alarm set-points and history files, and are programmable for specific applications. The Control Room Display assembly provides easy menu-driven access to database items, monitor remote control and display, and continuous polling for radiation level and operation status. Operators can also perform control functions such as purge, checksource and pump functions from the display to verify performance and status. Heat Traced Particulate, Iodine and Gas Monitor Off-Line Liquid Monitor

TYPE RANGE DESCRIPTION Gas Monitors Xe 133 : 3.4 x 10-7 to 3.4 x 10-1 µci/ml Off-line beta detector assembly designed for detecting activity concentration in a continuous gas sample. Attached to sample flow piping, the sample gas is drawn into the chamber at a set rate. Liquid Monitors Wide Range Gas Monitors (WRGM) Particulate Monitors Particulate and Gas Monitors (PG) (R.G. 1.45) Particulate and Iodine Monitors (PI) Particulate, Iodine and Gas Monitors (PIG) Cs 137 : 7.8 x 10-8 to 7.8 x 10-2 µci/ml Xe 133 : 10-7 to 10 5 µci/ml Cs 137 : 2.5 x 10-12 to 2.5 x 10-6 µci/ml Particulate: Cs 137 : 2.5 x 10-12 to 2.5 x 10-6 µci/ml Gas: Xe 133 : 5.4 x 10-7 to 5.4 x 10-1 µci/ml Particulate: Cs 137 : 2.5 x 10-12 to 2.5 x 10-6 µci/ml Iodine: I 131 : 2.9 x 10-11 to 2.9 x 10-5 µci/ml Particulate: Cs 137 : 2.5 x 10-12 to 2.5 x 10-6 µci/ml Iodine: I 131 : 2.9 x 10-11 to 2.9 x 10-5 µci/ml Gas: Xe 133 : 5.4 x 10-7 to 5.4 x 10-1 µci/ml Off-line gamma detector assembly designed for detecting activity concentration in a continuous liquid sample. Attached to sample flow piping, the sample liquid is pumped into the chamber at a set rate. Detects and measures off-line beta-gamma activity concentration levels by drawing a representative sample from the plant vent effluent flow. The sample flow is directed either to the normal or accident sample flow path determined by the sample activity concentration level. Safety related R.G. 1.97 qualified monitor. Off-line particulate detector assembly measures particulate activity concentrations. Samples are drawn continuously through a local particulate filter (fixed or moving filter available). Off-line PG monitor draws a representative sample from the plant containment atmosphere, provides sample flow through the monitor and measures the sample s radioactive level. Both channels utilize beta detectors to measure the activity concentration. Off-line PI monitor draws a representative sample from process gas or atmosphere, detects and measures process beta and gamma activity concentration. Designed for sampling and measurement of process gas streams. The off-line PIG monitor draws a representative sample from process gas or atmosphere, detects and measures process beta and gamma activity concentration.

IN-LINE AND ADJACENT-TO-LINE MONITORS Whether off-line, on-line, in-line or adjacent-to-line, our monitoring systems continuously measure radiation activity in the process gas, liquid or steam lines. Each system provides real-time processing of activity data, and maintains monitor and channel databases and multiple history files. In addition, monitors provide local detection, indicators and alarms. Each system communicates directly with the digital radiation processor to produce measurement data for display and processing, and to transmit status, activity data, alarm status, and receiving status inquiries. Depending on the system configuration, detectors are protected by a three or six inch lead shield assembly to minimize any background radiation from reaching the detector. A shielded door provides easy access to the detector. GA-EMS monitoring systems are configured to fit most pipe and cable sizes to eliminate the need for additional engineering costs to simplify installation and maintenance. Adjacent-to-Line Detector in Lead Shield Explosion Proof Gaseous Radwaste Discharge Monitor Stainless Steel In-Line Liquid Monitor

EMPLOYEE BENEFITS SUMMARY TYPE RANGE DESCRIPTION In-Line Liquid or Gas Monitors Cs 137 : 6.7 x 10-8 to 6.7 x 10-2 µci/ml Xe 133 : 2.1 x 10-7 to 2.1 x 10-1 µci/ml Provides continuous measurement of gamma activity concentration levels in the process lines. Examples of applications include: service water blowdown, steam generator blowdown and condenser off gas. In-Duct Gas Monitors Xe 133 : 1.5 x 10-7 to 1.5 x 10-1 µci/ml Continuously measures the level of beta activity concentration by directly interfacing with the air in a duct. Examples include fuel handling area exhaust, auxiliary building exhaust and control room vent. Adjacent-to-Line Monitors Cs 137 : 1.5 x 10-7 to 1.5 x 10-1 µci/ml Xe 133 : 5.1 x 10-6 to 5.1 x 10 0 µci/ml Mounts adjacent to main process lines to measure activity concentration without removing the sample or interrupting the line. Main Steam Line N16 Primary-to- Secondary Leak Monitors (R.G. 1.97) N 16 : 3.7 x 10-7 to 3.7 x 10-1 µci/ml An adjacent-to-line monitor that measures activity concentration of the main steam line to support leak rate calculations. Two different regions of interest (ROI) available for display and processing include the fission product and N 16 ROI. Main Steam Line Monitors (R.G. 1.97) Co 60 : 5.7 x 10-5 to 1.0 x 10 2 µci/ml Mounted in a lead shield adjacent to the main steam line to measure post-accident concentration of primary coolant in the main steam line. Lead shield minimizes the effect of the background radiation on the detector.

LOCAL/REMOTE PROCESSORS AND DATA ACQUISITION SYSTEMS GA-EMS local and remote processors and data acquisition systems provide powerful tools and software to capture, relay, analyze and display information to support decision making, and operational status and readiness. Control room processors and indicators offer remote control of the fielded processors and provide convenient, user-friendly interfaces with menu-driven access to database items, numerical and graphical data displays, alarms, and high resolution digital to analog converter outputs to plant interfaces. Each component is designed to suit various mounting configurations, provide ease of accessibility, and is seismically and environmentally qualified to meet safety requirements. RM-1000 RM-2020 RM-2000

MODEL TYPE DESCRIPTION RM-2000 Local Processor Multi-channel Performs data acquisition, analysis and display, monitor control functions, alarm relays, analog outputs, and digital communications. Includes application specific database, multiple history files, menu-driven interface, electronic calibration, automatic diagnostics/continuous self-test, and local status indication. RM-2020 Local Processor Single Channel RM-80 Local Processor Multi-channel (Legacy) Provides local and remote activity and alarm status. Generates operate and alert alarms and digital display of dose rate and monitor status. Includes database for configuration, data/alarm setpoints, calibration constants, history files and control functions. Includes checksource operations and communications with external devices. Performs data collection, data reduction, data analysis, data display, and alarm generation. Controls monitor functions and alarm relays, and maintains monitor and channel database information containing monitor operating parameters. RM-1000 Remote Indicator Single Channel Single channel digital radiation processor/rate meter module for use in various detector systems, both safety-related, Class1E, and non-safety related. Performs processing for both area and process monitor functions. Mounted in standard 19 rackmount NIM bin. RM-2300 Remote Processor Multi-channel Provides database control, display, and inquiry of fielded monitor via communications to the RM-2000. Numerical and graphical display of data. Provides alarm relay outputs. Mounted in standard 19 rackmount NIM bin. RM-11U Central Computer System Monitors and displays data and logs alarm messages from all RM-2000 and RM-2020 in a given network via communication loops. Provides capability for the operator to control the monitor equipment including pumps, checksource, and purge. Provides the operator with display screens showing detector activity levels, status, alarms, trends, database information, and communication statistics. Maintains information for each monitor by polling each RM-2000 and RM-2020 for activities, flow values, alarms, and status.

SPECIAL TOOLS MODEL TYPE DESCRIPTION RT-10 G-M Tube Transfer Calibration Source Allows performance of routine transfer calibrations of G-M tube area radiation detectors. Uses a C 137 source contained in a 4π lead shield for safe handling. RT-11 Ion Chamber Transfer Calibration Source Allows performance of routine transfer calibrations of ion chamber area radiation detectors. Uses a C 137 source contained in a 4π lead shield for safe handling. Simulator RM-2000 Simulator Software PC based software application simulates all features of the RM-2000 microprocessor for use in simulator systems and training systems. MI-2080 Maintenance Interface Software Kit PC based remote software interface to RM-80 and RM-2000 monitors. Provides data analysis and maintenance functionality, is capable of querying data from individual monitors and displaying this data to the user as well as downloading data to a monitor in the form of database changes. The software provides a tabular database view, a user-controlled graph display, data-logging capabilities, and the ability to monitor a single radiation monitor. The software can display trends, channel-selection graph, flow graph, checksource trend, K-list display and verification, and communication statistics. GENERAL ATOMICS ELECTROMAGNETIC SYSTEMS WWW.GA.COM rms.info@ga.com Technical descriptions and specifications contained herein provide general product guidelines and are for informational purposes only. All content and specifications are subject to change without notice. All trademarks and registered trademarks are the property of their respective companies. RMS Overview rev.a 1117-2015