APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM
|
|
|
- Howard Atkinson
- 10 years ago
- Views:
Transcription
1 APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM The supplemental inspection program is designed to support the NRC s goals of maintaining safety, enhancing public confidence, improving the effectiveness, efficiency and realism of the regulatory process, and reducing unnecessary regulatory burden. While the baseline inspection program and performance indicators should provide sufficient information to allow the NRC to meet the goal of assuring licensee s are maintaining safety at facilities with an absence of risk significant performance issues, additional supplemental inspections are required 1 to provide enhanced information regarding safety at facilities where risk significant performance issues have been identified. These performance issues may be identified either by inspection findings evaluated using the significance determination process (SDP) or when performance indicator thresholds are exceeded. The breadth and depth of the supplemental inspections increase in proportion to the relative risk significance of the identified performance issues and will be based upon the guidance provided in the NRC s assessment Action Matrix and the Supplemental Inspection Selection Table. B. APPLICABILITY The supplemental inspections contained in this Appendix apply to all strategic performance areas and associated cornerstones of safety. The inspection report written for the supplemental inspections should contain the NRC s assessment for each inspection requirement. These inspection requirements are independent of whether the performance issues were the result of performance indicators or inspection findings. The resource estimates provided in each supplemental inspection procedure are estimates only, and may vary considerably due to the complexity of the issue(s) and the thoroughness of the licensee s own evaluations and proposed corrective actions. 1 Note that the assessment process allows the option of not performing a supplemental inspection for a white issue identified as part of a licensee self assessment activity. This is not considered a deviation from the action matrix. Issue Date: 03/23/05 B Appendix B
2 SUPPLEMENTAL INSPECTION SELECTION TABLE One or two white inputs (in different cornerstones) in a strategic performance area One degraded cornerstone (two white inputs or one yellow input) or any three white inputs in a strategic performance area Repetitive degraded cornerstone, multiple degraded cornerstones, multiple yellow inputs, or any one red input Supplemental Inspection and Scope Inspection consisting of review of the licensee s evaluation of root cause and extent of condition; plus review of proposed corrective actions. Follow-up NRC inspection to determine effectiveness of corrective actions. Inspection limited to specific issue(s) or performance area of concern. Inspection consisting of review of the licensee s evaluation of root cause and extent of condition, plus review of proposed corrective actions for both individual and collective issues. Independent NRC inspection to assess validity of licensee s extent of condition. Followup NRC inspection to evaluate adequacy of licensee corrective actions. Inspection consisting of a large multidisciplined NRC team inspection(s). Inspection focused on all key attributes associated with effected strategic performance areas Appendix B B-2 Issue Date: 03/23/05
3 Assessment of Supplemental Inspection Findings Significant weaknesses in the licensee s evaluation may result in expansion of the inspection to independently acquire the information necessary to satisfy the inspection requirements. The original issue may also not be removed from the action matrix until the weaknesses in the evaluation are addressed. Significant weaknesses in licensee evaluation may result in expansion of the inspection to independently acquire the information necessary to satisfy the inspection requirements. The original issue may also not be removed from the action matrix until the weaknesses in the evaluation are addressed. Results of this supplemental inspection will be assessed to determine if additional agency actions are warranted and whether the facility should be ordered to shut down and be placed under Inspection Manual Chapter C. DESCRIPTION OF SUPPLEMENTAL INSPECTION PROGRAM The supplemental inspection program contains three procedures which become deeper and broader as the safety significance of the performance issues increases. For one or two white inputs in a strategic performance area (different cornerstones), supplemental inspection is limited to a thorough oversight of the licensee s evaluation. For one degraded cornerstone or any three white inputs in a strategic performance area, the supplemental inspection will also review the licensee s collective evaluation for multiple issues. In addition, the portions of the licensee s evaluation concerning extent of condition will be assessed independently by the NRC. This independent assessment will be conducted using inspection procedures selected from tables that list the procedures by cornerstone and key attribute provided in Attachment 1 to this Appendix. The objective of this inspection will be to ensure that the licensee has properly identified the scope (extent) of the issues and that the proposed corrective actions are sufficiently comprehensive. The inspection procedures listed in the Attachment 1 tables include: baseline inspection procedures (portions of which can be repeated with additional samples); procedures that were part of the core, regional initiative, and temporary instruction portions of the old inspection program; and new inspection procedures written solely for the purpose of performing supplemental inspection. A combination of procedures or portions of procedures can also be used as appropriate. Inspection hours utilized in fulfilling this inspection requirement should be charged to inspection procedure 95002, regardless of the specific procedure(s) chosen for implementation. D. ASSESSING INSPECTION FINDINGS Issue Date: 03/23/05 B Appendix B
4 If during implementation of Inspection s or 95002, significant weaknesses are identified in the licensee s evaluation of the performance issue, the inspection may be expanded as necessary to independently acquire the information necessary to satisfy the inspection requirements. Also, the original performance issue will remain open and will not be removed from the action matrix until the weaknesses in the evaluation are addressed and corrected. Programmatic weaknesses associated with the licensee s evaluation of the performance issue will also be documented in the inspection report and additional focus will be given to those areas during the next annual problem identification and resolution baseline inspection. Should new or additional examples of performance issues (non-programmatic) be identified during supplemental inspections, the new issues will be categorized using the SDP, and if indicated, the corresponding supplemental inspection procedure will be performed. Supplemental inspections will also be performed if additional examples of performance issues are reported via PIs that result in crossing a new PI threshold. Additional supplemental inspections will generally not be performed if the new or additional examples of performance issues reported via PIs do not result in crossing a new PI threshold. Significant weaknesses identified during performance of Inspection will be assessed to determine if additional agency actions are warranted and whether the facility should be ordered to be shut down. In such cases, the facility will be placed under Inspection Manual Chapter END 2515 Appendix B B-4 Issue Date: 03/23/05
5 ATTACHMENT 1 INSPECTION PROCEDURES TO BE USED FOR ASSESSING EXTENT OF CONDITION INITIATING EVENTS Protection Against External Events Human Performance Quality Equipment Performance Design Configuration Control General s Issue Date: 03/23/05 Att , App B
6 MITIGATING SYSTEMS Design Protection Against External Events Configuration Control Equipment Performance Quality Human Performance General s , App B Att 1-2 Issue Date: 03/23/05
7 BARRIER INTEGRITY Fuel Cladding Performance RCS Equip. & Barrier Perf. Containment SSC & Barrier Perf. Human Performance Quality Design Control Configuration Control General s Issue Date: 03/23/05 Att , App B
8 EMERGENCY PREPAREDNESS ERO Readiness Facilities and Equipment Quality ERO Performance Offsite EP No NRC inspection of this key attribute. - Evaluation performed by FEMA PUBLIC RADIATION SAFETY Facilities/Equipment Program/Process Human Performance OCCUPATIONAL RADIATION SAFETY Facilities and Equipment Program/Process Human Performance General s , App B Att 1-4 Issue Date: 03/23/05
9 PHYSICAL PROTECTION Physical Protection System Access Authorization System Access Control System Response to Contingency Events END Issue Date: 03/23/05 Att , App B
10 ATTACHMENT 2 PROCEDURES LISTED IN ATTACHMENT 1 Inspection No. Inspection Title Commercial Grade Procurement Inspection Training and Qualification Effectiveness Emergency Operating s Plant s Inspection of Erosion/Corrosion Monitoring Programs Steam Generators Digital Retrofits Receiving Prior Approval Digital Retrofits Not Receiving Prior Approval Nuclear Welding General Inspection Structural Welding General Inspection Calibration Nondestructive Examination Visual Examination Review/Work Observation/ Record Review Nondestructive Examination Liquid Penetrant Examination Review/Work Observation/Record Review Nondestructive Examination Magnetic Particle Examination Review/Work Observation/Record Review Nondestructive Examination Ultrasonic Examination Review/Work Observation Record Review Issue Date: 03/23/05 Att , App B
11 Inspection No. Inspection Title Nondestructive Examination Radiographic Examination Review/Work Observation/ Record Review Surveillance of Core Power Distribution Limits Calibration of Nuclear Instrumentation Systems Core Thermal Power Evaluation Determination of Reactor Shutdown Margin Isothermal and Moderator Temperature Coefficient Determinations Total Power Coefficient of Reactivity at Pressurized Water Reactors Control Rod Worth Measurement Verification of Containment Integrity Containment Local Leak Rate Testing Independent Measurement of RCS Leak Rates for a PWR Inspection of Structures, Passive Components, and Civil Engineering Features at Nuclear Power Plants Inspection of Steel and Concrete Containment Structures at Nuclear Power Plants Maintenance Program Implementation Maintenance Rule Inspection Motor-Operated Valve Capability Configuration Risk Assessment and Risk Management Process Power-Operated Gate Valve Pressure Locking and Thermal Binding Containment Integrated Leak Rate Test - Review 2515, App B Att 2-2 Issue Date: 03/23/05
12 Inspection No. Inspection Title Containment Integrated Leak Rate Test Containment Leak Rate Test Results Evaluation Testing Piping Support and Restraint Systems Plant Operations Sustained Control Room and Plant Observation Supplemental Inspection for Human Performance Modification Testing Inservice Inspection - Review of Program Inservice Inspection - Review of s Inservice Inspection Inservice Inspection - Data Review and Evaluation Inservice Testing of Pumps and Valves Control and Monitoring of Radiological Source Term Security Plan and Implementing s Management Effectiveness - Security Program Security Organization Security Program Audit Records and Reports Testing and Maintenance Locks, Keys, and Combinations Physical Barriers-Protected Areas Physical Barriers-Vital Areas, Material Access Areas and Controlled Access Areas Issue Date: 03/23/05 Att , App B
13 Inspection No. Inspection Title Security System Power Supply Lighting Compensatory Measures Assessment Aids Access Control - Personnel Access Control (Power Reactor) - Packages Access Control - Vehicles Detection Aids - Protected Areas Detection Aids - VA, MAA, CAA Alarm Stations Communications Operational Safeguards Response Evaluation (OSRE) Personnel Training and Qualifications - General Requirements Fitness for Duty Program Safeguards Contingency Plan Implementation Review Protection of Safeguards Information Evaluation of Emergency Preparedness Emergency Detection and Classification Protective Action Decision Making Significant Uncontrolled Exposures Evaluation of Public Radiation Safety Radioactive Gaseous and Liquid Trreatment and Monitoring Systems 2515, App B Att 2-4 Issue Date: 03/23/05
14 Inspection No. Inspection Title Radioactive Material Process and Transportation Radiological Environmental Monitoring Program and Radioactive Material Control Program Training and Qualifications: General Employee Training, Radiation Safety, Plant Chemistry, Radwaste, and Transportation External Occupational Exposure Control and Personal Dosimetry Internal Exposure Control and Assessment Maintaining Occupational Exposures ALARA Transportation of Radioactive Materials (49CFR Parts & 10 CFR Part 71) Feedback of Operational Experience Information at Operating Power Reactors In-Office Review of Written Reports of Nonroutine Events at Power Reactor Facilities Onsite Follow-up of Written Reports of Nonroutine Events at Power Reactor Facilities Safety System Functional Inspection (SSFI) Operational Safety Team Inspection (OSTI) Safety Systems Outage Modifications Inspection Risk-Based Operational Safety and Performance Inspection Maintenance Program Operational Readiness Assessment Team Inspections Systems Based Instrumentation and Control Inspection Service Water System Operational Performance Inspection (SWSOPI) Issue Date: 03/23/05 Att , App B
15 Inspection No. Inspection Title Electrical Distribution System Functional Inspection (EDSFI) END 2515, App B Att 2-6 Issue Date: 03/23/05
Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1]
Nuclear Safety Council Instruction number IS-22, of July 1st 2009, on safety requirements for the management of ageing and long-term operation of nuclear power plants Published in the Official State Gazette
Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants
Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants Published in the Official State Gazette (BOE) No 283 of November 24 th 2009 Nuclear Safety Council Instruction
NEI 06-13A [Revision 0] Template for an Industry Training Program Description
NEI 06-13A [Revision 0] Template for an Industry Training Program Description NEI 06-13A [Revision 0] Nuclear Energy Institute Template for an Industry Training Program Description ACKNOWLEDGEMENTS This
AP1000 European 18. Human Factors Engineering Design Control Document
18.2 Human Factors Engineering Program Management The purpose of this section is to describe the goals of the AP1000 human factors engineering program, the technical program to accomplish these goals,
NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1. Renewed License No. NPF-63
CAROLINA POWER & LIGHT COMPANY NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY DOCKET NO. 50-400 SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 RENEWED FACILITY OPERATING LICENSE 1. The Nuclear Regulatory Commission
NRC INSPECTION MANUAL
NRC INSPECTION MANUAL INSPECTION PROCEDURE 71114.03 NSIR/DPR EMERGENCY RESPONSE ORGANIZATION STAFFING AND AUGMENTATION SYSTEM PROGRAM APPLICABILITY: 2515 71114.03-01 INSPECTION OBJECTIVE To evaluate the
Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3
GUIDE 26 June 2000 YVL 2.1 Nuclear power plant systems, structures and components and their safety classification 1 General 3 2 Safety classes 3 3 Classification criteria 3 4 Assigning systems to safety
NRC INSPECTION MANUAL INSPECTION PROCEDURE 88045
NRC INSPECTION MANUAL INSPECTION PROCEDURE 88045 NMSS/FCSS EFFLUENT CONTROL AND ENVIRONMENTAL PROTECTION PROGRAM APPLICABILITY: 2600 88045-01 INSPECTION OBJECTIVES The objectives of this procedure are
Qualification of In-service Inspections of NPP Primary Circuit Components
Qualification of In-service Inspections of NPP Primary Circuit Components ABSTRACT Matija Vavrouš, Marko Budimir INETEC Institute for nuclear technology Dolenica 28, 10250 Zagreb, Croatia [email protected],
Government Degree on the Safety of Nuclear Power Plants 717/2013
Translation from Finnish. Legally binding only in Finnish and Swedish. Ministry of Employment and the Economy, Finland Government Degree on the Safety of Nuclear Power Plants 717/2013 Chapter 1 Scope and
How To Determine An Operating Safety Certificate
NRC INSPECTION MANUAL ITSB PART 9900: TECHNICAL GUIDANCE OPERABILITY DETERMINATIONS & FUNCTIONALITY ASSESSMENTS FOR RESOLUTION OF DEGRADED OR NONCONFORMING CONDITIONS ADVERSE TO QUALITY OR SAFETY TABLE
Asset Integrity - Process Safety Management
Asset Integrity - Process Safety Management Commit to Process Safety Understand Hazards & Risks Manage Risk Learn from experience Process safety culture Compliance with standards Process safety competency
How To Improve Safety At A Nuclear Power Plant
OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE August 6, 2015 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs Program Overview Bill Dean Director Office of Nuclear Reactor
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, D.C. 20555-0001. June 1, 2005
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, D.C. 20555-0001 June 1, 2005 NRC INFORMATION NOTICE 2005-14: FIRE PROTECTION FINDINGS ON LOSS OF SEAL COOLING
Report WENRA Safety Reference Levels for Existing Reactors - UPDATE IN RELATION TO LESSONS LEARNED FROM TEPCO FUKUSHIMA DAI-ICHI ACCIDENT
Report WENRA Safety Reference Levels for Existing Reactors - UPDATE IN RELATION TO LESSONS LEARNED FROM TEPCO FUKUSHIMA DAI-ICHI ACCIDENT 24 th September 2014 Table of Content WENRA Safety Reference Levels
OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE. July 7, 2016 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs
OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE July 7, 2016 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs Program Overview Bill Dean Director Office of Nuclear Reactor
Nuclear Power Plant Electrical Power Supply System Requirements
1 Nuclear Power Plant Electrical Power Supply System Requirements Željko Jurković, Krško NPP, [email protected] Abstract Various regulations and standards require from electrical power system of the
EMERGENCY PREPAREDNESS FREQUENTLY ASKED QUESTION (EPFAQ) NEI 99 01 REVISIONS 4 THROUGH 6; NUMARC/NESP 007
EPFAQ Number: 2015 001 DATE ACCEPTED 20 Apr 15 ORIGINATOR DAVID YOUNG ORGANIZATION Nuclear Energy Institute (NEI) PHONE # 202 739 8016 RELEVANT GUIDANCE: NEI 99 01 REVISIONS 4 THROUGH 6; NUMARC/NESP 007
This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and
This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and suppliers. It is transmitted to you in confidence and trust,
7.1 General 5 7.2 Events resulting in pressure increase 5
GUIDE YVL 2.4 / 24 Ma r ch 2006 Primary and secondary circuit pressure control at a nuclear power plant 1 Ge n e r a l 3 2 General design requirements 3 3 Pressure regulation 4 4 Overpressure protection
Elements of the Russian Emergency Preparedness Program
Elements of the Russian Emergency Preparedness Program Randolph L. Sullivan, NRC National Radiological EP Conference St. Louis, Missouri March 2006 2 3 4 5 6 Volgodonsk NPP 1000 MWe VVER, a PWR Large Staff
NUCLEAR POWER PLANT PRESSURE EQUIPMENT
GUIDE YVL 3.8 / 22 SEPTEMBER 2003 NUCLEAR POWER PLANT PRESSURE EQUIPMENT In-service inspection with non-destructive testing methods 1 GENERAL 5 2 DEFINITIONS 5 3 REQUIREMENTS 7 4 IN-SERVICE INSPECTION
Management Structure
Senior Executive Team (SET) Executive Sponsor & Team Leader - President & CEO Responsibility: Provides oversight of STP on behalf of the Owners, serves as a guiding coalition in achieving Operational and
NEI 06-13A [Revision 2] Template for an Industry Training Program Description
NEI 06-13A [Revision 2] Template for an Industry Training Program Description NEI 06-13A [Revision 2] Nuclear Energy Institute Template for an Industry Training Program Description ACKNOWLEDGEMENTS This
Quality Management System-A Revision 7 (NRC-approved Version)
Westinghouse Non-Proprietary Class 3 2013 Westinghouse Electric Company LLC. All Rights Reserved. Quality Management System-A (NRC-approved Version) Westinghouse Electric Company Quality Management System
Nuclear Safety Council Instruction number IS-19, of October 22 nd 2008, on the requirements of the nuclear facilities management system
Nuclear Safety Council Instruction number IS-19, of October 22 nd 2008, on the requirements of the nuclear facilities management system Published in the Official State Gazette (BOE) number 270 of November
NRC Enforcement Policy
January 28, 2013 Revised July 9, 2013 Interim Enforcement Policy (Section 9.2) U. S. Nuclear Regulatory Commission Office of Enforcement Washington, DC 20555-00 NRC ENFORCEMENT POLICY CONTENTS PREFACE...
REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE 1.174 (Draft was issued as DG-1226, dated August 2009)
U.S. NUCLEAR REGULATORY COMMISSION May 2011 Revision 2 REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 1.174 (Draft was issued as DG-1226, dated August 2009) AN APPROACH FOR USING
License Application Package Overview MOX Fuel Fabrication Facility 27 September 2006
License Application Package Overview MOX Fuel Fabrication Facility 27 September 2006 Enclosure 4 Agenda Purpose Background License Application Overview Development Strategy Chapter Reviews Configuration
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE RD. SUITE 210 LISLE, IL 60532-4352. August 12, 2015
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE RD. SUITE 210 LISLE, IL 60532-4352 August 12, 2015 EA-15-130 Mr. Peter A. Gardner Monticello Nuclear Generating Plant Northern States
Office for Nuclear Regulation
ONR GUIDE LC17 Management Systems Document Type: ONR Nuclear Safety Technical Inspection Guide Unique Document ID and Revision No: NS-INSP-GD-017 Revision 2 Date Issued: November 2012 Review Date: November
MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES
ORDER DOE O 433.1B Approved: 4-21-2010 MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES U.S. DEPARTMENT OF ENERGY Office of Health, Safety and Security DOE O 433.1B 1 4-21-2010 MAINTENANCE MANAGEMENT
Owner-User Pressure Equipment Integrity Management Requirements
the pressure equipment safety authority Owner-User Pressure Equipment Integrity Management Requirements AB-512 Edition 2, Revision 0 Issued 2015-06-25 Owner-user Pressure Equipment Integrity Management
Emergency Preparedness at Nuclear Power Plants
A White Paper Addressing Compliance with NRC Proposed Rule making Emergency Preparedness at Nuclear Power Plants Ensuring Readiness and Compliance with New NRC Regulation of Emergency Preparedness Programs
On-Site Risk Management Audit Checklist for Program Level 3 Process
On-Site Risk Management Audit Checklist for Program Level 3 Process Auditor name: Date: I. Facility Information: Facility name: Facility location: County: Contact name: RMP Facility I.D. Phone Number:
RC-17. Alejandro V. Nader National Regulatory Authority Montevideo - Uruguay
RC-17 Radiation Protection in Waste Management and Disposal Implementing the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management Alejandro V. Nader
NRC INSPECTION MANUAL
NRC INSPECTION MANUAL NSIR/DPR INSPECTION PROCEDURE 71114.02 ALERT AND NOTIFICATION SYSTEM EVALUATION PROGRAM APPLICABILITY: 2515 71114.02-01 INSPECTION OBJECTIVE To evaluate the licensee s compliance
EDUCATION AND TRAINING OF OPERATORS AND MAINTENANCE STAFF AT COMMERCIAL NUCLEAR POWER STATIONS IN JAPAN
IAEA-CN-73/42 EDUCATION AND TRAINING OF OPERATORS AND MAINTENANCE STAFF AT COMMERCIAL NUCLEAR POWER STATIONS IN JAPAN M.TAKAHASHI Chubu Electric Power Co., Inc. XA9847813 H. KATAOKA Kansai Electric Power
IAEA Safety Standards for Regulatory Activities
Safety Standards for Regulatory Activities April 2010 Gustavo Caruso Regulatory Activities Section Division of Nuclear Installation Safety International Atomic Energy Agency Content Safety Standards and
NUCLEAR REGULATORY COMMISSION
GAO United States Government Accountability Office Report to Congressional Requesters October 2012 NUCLEAR REGULATORY COMMISSION Oversight and Status of Implementing a Risk-Informed Approach to Fire Safety
ETCAL Level 3 NVQ Diploma in Engineering Technical Support (QCF) Qualification No 600/2285/1 Credit Value 80 GLH 311. Qualification Structure
ETCAL Level 3 NVQ Diploma in Engineering Technical Support (QCF) Qualification No 600/2285/1 Credit Value 80 GLH 311 Qualification Structure Unit Number Unit Title Unit Credit Value/GLH QCF Unit Number
Nuclear Emergency Response Program
Nuclear Emergency Response Program NUCLEAR POWER PLANTS In California, there are two operating nuclear power plant sites: Diablo Canyon in San Luis Obispo County has two active units and San Onofre Nuclear
SAFETY DESIGN OF A NUCLEAR POWER PLANT
GUIDE YVL B.1 / 15 November 2013 SAFETY DESIGN OF A NUCLEAR POWER PLANT 1 Introduction 5 2 Scope 5 3 Management of design 5 3.1 Organisations responsible for design 5 3.2 Design processes 6 3.3 Configuration
Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions
Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions John Gaertner Technical Executive Electric Power Research Institute Charlotte, North Carolina,
MATERIALS LICENSE. 1. Honeywell International, Inc. 3. License Number: SUB-526, Amendment 6-1
NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION Page 1 of 5 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal
Operating Performance: Accident Management: Severe Accident Management Programs for Nuclear Reactors REGDOC-2.3.2
Operating Performance: Accident Management: Severe Accident Management Programs for Nuclear Reactors REGDOC-2.3.2 September 2013 Accident Management: Severe Accident Regulatory Document REGDOC-2.3.2 Canadian
Security Barriers in the Physical Protection Concept of Nuclear Facilities In Switzerland
Security Barriers in the Physical Protection Concept of Nuclear Facilities In Switzerland B. Wieland Swiss Federal Office of Energy, CH 3003 Berne, Switzerland ABSTRACT: The presentation describes the
Executive Director for Operations AUDIT OF NRC S CYBER SECURITY INSPECTION PROGRAM FOR NUCLEAR POWER PLANTS (OIG-14-A-15)
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 OFFICE OF THE INSPECTOR GENERAL May 7, 2014 MEMORANDUM TO: Mark A. Satorius Executive Director for Operations FROM: Stephen D. Dingbaum
Sara Brock Counsel for NRC Staff
NUCLEAR UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-D001 May 16, 2002 OFFICE OF THE GENERAL COUNSEL Charles Administrative Bechhoefer, Judge Chairman Richard Administrative F. Cole
Wilfred C. LaRochelle Principal Nuclear Consultant HSB Global Standards, USA
Wilfred C. LaRochelle Principal Nuclear Consultant HSB Global Standards, USA ASME Vice President, Conformity Assessment and Vice Chairman of Committee on Nuclear Certification 2nd NRC Workshop on Vendor
NRC Cyber Security Regulatory
Ask SME and Learn NRC Cyber Security Regulatory Program Development Mario R. Fernandez Jr., Security Specialist (Cyber) Cyber Security Directorate Office of Nuclear Security & Incident Response 1 Agenda
Introductions: Dr. Stephen P. Schultz
Introductions: Dr. Stephen P. Schultz Vienna, Austria 1 3 September 2015 Work Experience Current Member Advisory Committee on Reactor Safeguards, U.S. Nuclear Regulatory Commission, 12/2011 Chair, Fukushima
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001. June 16, 2011
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001 June 16, 2011 NRC INFORMATION NOTICE 2011-12: REACTOR TRIPS RESULTING FROM WATER INTRUSION INTO
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
DOE O 226.1A, IMPLEMENTATION OF DEPARTMENT OF ENERGY OVERSIGHT POLICY CONTRACTOR ASSURANCE SYSTEMS CRITERIA ATTACHMENT 1, APPENDIX A
DOE O 226.1A, IMPLEMENTATION OF DEPARTMENT OF ENERGY OVERSIGHT POLICY CONTRACTOR ASSURANCE SYSTEMS CRITERIA ATTACHMENT 1, APPENDIX A DEFINITIONS Assurance systems encompass all aspects of the processes
Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP)
Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP) A. Yamamoto a, A. Huerta a, K. Gott b, T. Koshy c a Nuclear Safety Division, OECD Nuclear Energy
Backgrounder Office of Public Affairs Telephone: 301/415-8200 E-mail: [email protected]
Backgrounder Office of Public Affairs Telephone: 301/415-8200 E-mail: [email protected] Nuclear Security Background While security of the nuclear facilities and materials the NRC regulates has always been a
RADIATION MONITORING SYSTEMS
RADIATION MONITORING SYSTEMS Area monitors Process monitors In-line, Adjacent-to-Line monitors Local/remote processors, Data Acquisition Systems NUPIC Certified, NRC Approved Vendor Wide Range Sensitivity
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001. November 13, 2012
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 13, 2012 Vice President, Operations Entergy Nuclear Operations, Inc. Vermont Yankee Nuclear Power Station P.O. Box 250 Governor
NON-DESTRUCTIVE TESTING FULL SCOPE OF INTEGRATED NDT SERVICES
NON-DESTRUCTIVE TESTING FULL SCOPE OF INTEGRATED NDT SERVICES RIGHT SERVICE MAXIMUM RETURN Whether it is in fabrication, pipe manufacturing, pipeline, plant construction, chemical, petrochemical plants,
NRC INSPECTION MANUAL
NRC INSPECTION MANUAL CIPB MANUAL CHAPTER 2506 CONSTRUCTION REACTOR OVERSIGHT PROCESS GENERAL GUIDANCE AND BASIS DOCUMENT 2506-01 PURPOSE... 1 2506-02 OBJECTIVES... 1 2506-03 APPLICABILITY... 1 2506-04
Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.
Exelon Generation 200 Exelo11 Way Kennett Square. PA 19348 www.pxeloncoroi.c cm 10 CFR 50.55a August 13, 2015 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Peach
The World Nuclear Supply
The World Nuclear Supply Chain An Overview Greg KASER Staff Director NEA International WPNE Workshop Paris 11 March 2014 Outline of Presentation 1. About WNA 2. Value of: New construction Early dismantlement
ANNUAL FIRE PROTECTION SUMMARY INFORMATION REPORTING GUIDE Revised: May 2011
ANNUAL FIRE PROTECTION SUMMARY INFORMATION REPORTING GUIDE Revised: May 2011 Organizations responsible for maintaining property under stewardship of DOE and the Administrator, NNSA, will seek concurrence
US-APWR Human Performance Monitoring Implementation Plan
US-APWR Human Performance Monitoring Implementation Plan April 2010 2010 Mitsubishi Heavy Industries, Ltd. All Rights Reserved US-APWR Human Performance MonitQring Implementation Plan Plan MUAP-10014 (RO)
Spreading the Word on Nuclear Cyber Security
Spreading the Word on Nuclear Cyber Security Clifford Glantz, Guy Landine, Philip Craig, and Robert Bass Pacific Northwest National Laboratory (PNNL) PO Box 999; 902 Battelle Blvd Richland, WA 99352 USA
F4E-QA-010 - QUALITY CLASSIFICATION
idm@f4e UID / VERSION 22MD99 / 2.0 VERSION CREATED ON / STATUS 20 Jul 2012 / APPROVED EXTERNAL REFERENCE (F4EDocs: N22010) Quality Procedures F4E-QA-010 - QUALITY CLASSIFICATION This document describes
Jonathan Wilson. Sector Manager (Health & Safety)
Jonathan Wilson Sector Manager (Health & Safety) OHSAS 18001:2007 Making Life Easier For Health & Safety Managers Workshop Agenda 1. Introduction 2. Why Manage Health & Safety 3. OHSAS 18001 and OHSMS
ABSTRACT. The Guidelines Section F is related to the Purchasing requirements of NSQ100 (Chapter 7.4). Summary
Page 1 / 9 ABSTRACT This document is the Section F to NSQ-100 Guidelines. Its objective is to help to the understanding of NSQ-100 requirements through some examples or recommendations and descriptions
Doel 3 & Tihange 2 RPV Flaw Indications. Evaluation by Belgian Safety Authorities. 1. Regulatory Body in Belgium 28/06/2013
Doel 3 & Tihange 2 RPV Flaw Indications Evaluation by Belgian Safety Authorities 28-06-2013 Doel 3 & Tihange 2 RPV Flaw Indications Evaluation by Belgian Safety Authorities 1. Regulatory Body in Belgium
Options for Cyber Security. Reactors. April 9, 2015
Options for Cyber Security Design Requirements for Power Reactors April 9, 2015 Scope Discuss options for including cyber security design requirements for power reactors into NRC regulations Scope does
8. USE OF DELTA CDF (AND DELTA LERF) AS THE SDP RISK METRIC
8. USE OF DELTA CDF (AND DELTA LERF) AS THE SDP RISK METRIC The relationship between delta CDF and CCDP (conditional core damage probability) is described below. This discussion is also correspondingly
MANAGEMENT SYSTEM FOR A NUCLEAR FACILITY
GUIDE YVL A.3 / 2 June 2014 MANAGEMENT SYSTEM FOR A NUCLEAR FACILITY 1 Introduction 5 2 Scope of application 6 3 Management system 6 3.1 Planning, implementation, maintenance, and improvement of the management
IAEA-TECDOC-1458. Effective corrective actions to enhance operational safety of nuclear installations
IAEA-TECDOC-1458 Effective corrective actions to enhance operational safety of nuclear installations July 2005 IAEA SAFETY RELATED PUBLICATIONS IAEA SAFETY STANDARDS Under the terms of Article III of its
Belgian Stress tests specifications Applicable to all nuclear plants, excluding power reactors 22 June 2011
Belgian Stress tests specifications Applicable to all nuclear plants, excluding power reactors 22 June 2011 Introduction Considering the accident at the Fukushima nuclear power plant in Japan, the European
Belgian Stress tests specifications Applicable to power reactors 17 May 2011
Belgian Stress tests specifications Applicable to power reactors 17 May 2011 Introduction Considering the accident at the Fukushima nuclear power plant in Japan, the European Council of March 24 th and
How To Decommission A Nuclear Plant
International Atomic Energy Agency Decommissioning of Nuclear Facilities Management of Decommissioning Projects Lawrence E. Boing Manila, Philippines, October 2006 1 Lesson Objectives Understand the management
Harris Nuclear Plant (HNP) NFPA 805 Transition. NFPA 805 Monitoring Program
Harris Nuclear Plant (HNP) NFPA 805 Transition NFPA 805 Monitoring Program Oconee / Harris NFPA 805 Pilot Observation Meeting April 14-16, 2008 Charlotte, NC Keith Began, CES/FP Review from Nov. 2007 Pilot
R000. Revision Summary Revision Number Date Description of Revisions R000 Feb. 18, 2011 Initial issue of the document.
2 of 34 Revision Summary Revision Number Date Description of Revisions Initial issue of the document. Table of Contents Item Description Page 1. Introduction and Purpose... 5 2. Project Management Approach...
This occurrence is considered to be of no significance with respect to the health and safety of the public.
Serial No. MNS-15-072 September 10, 2015,. DUKESteven Vice D. President Capps, ENERGYMcGuire Nuclear Station Duke Energy MGOIVP 1 12700 Hagers Ferry Road Huntersville, NC 28078 0: 980.875.4805 f: 980.875.4809
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001. March 3, 2011
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 3, 2011 Mr. Timothy S. Rausch Senior Vice President and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick,
MDEP Generic Common Position No DICWG 02
MDEP Generic Common Position No DICWG 02 Related to: Digital Instrumentation and Controls Working Group activities COMMON POSITION ON SOFTWARE TOOLS FOR THE DEVELOPMENT OF SOFTWARE FOR SAFETY SYSTEMS 1
Radiological Control Technician Training Technician Qualification Standard
Part 2 of 9 Radiological Control Technician Training Technician Qualification Standard Coordinated and Conducted for the Office of Health, Safety and Security U.S. Department of Energy This page intentionally
U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN OFFICE OF NUCLEAR REACTOR REGULATION
U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN OFFICE OF NUCLEAR REACTOR REGULATION NUREG-0800 (Formerly NUREG-75/087) 9.2.2 REACTOR AUXILIARY COOLING WATER SYSTEMS REVIEW RESPONSIBILITIES Primary
Shell s Health, Safety and Environment (HSE) management system (see Figure 11-1) provides the framework for managing all aspects of the development.
Section 11.1 APPLICATION FOR APPROVAL OF THE DEVELOPMENT PLAN FOR NIGLINTGAK FIELD PROJECT DESCRIPTION INTRODUCTION 11.1.1 HSE MANAGEMENT SYSTEM Shell s Health, Safety and Environment (HSE) management
Proposal to Consolidate Post-Fukushima Rulemaking Activities
Proposal to Consolidate Post-Fukushima Rulemaking Activities On January 28, 2014, the U.S. Nuclear Regulatory Commission s (NRC s) Fukushima Steering Committee endorsed an NRC staff proposal for integrating
SECTION A... 3 SECTION B... 7
BRITISH COLUMBIA SAFETY AUTHORITY Manual for Owners and Operators of Special Status Plants Risk Assessed and General Supervision Date: March 12, 2012 Controlled Document: MAN -4000-03 I TABLE OF CONTENTS
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
