HVAC air curtains. Type InduAir



Similar documents
HDA

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

SERVER ROOM CABINET INSTALLATION CONCEPTS

ECOCIAT. Domestic hot water heat recovery unit

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

High-speed folding doors. F Series

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

IV. Rear Mount System

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Installation, operation and maintenance manual TX 35A

Cooking at the Speed of light!

AMCA International. Investigation of the Impact of Building Entrance Air Curtain on Whole Building Energy Use AIR MOVEMENT AND CONTROL

The most comfortable air-conditioning systems for yachts and superyachts

Weiss Mobile Air Conditioning Systems

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Refrigeration Compressed Air Dryer Buran Ultrapulse

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

plenum slot diffusers

PRODUCT DIRECT EVAPORATIVE COOLING PAD DATA SHEET

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

Under sill units. Type FSL-B-ZAS

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

RPV - RP - RA air handling units

york air-conditioning products Residential & VRF News 2015

Split units TH with hermetic compressors

Freezers - Ultrafreezers. Platilab & Irilab Series

CRAC Precision climate control units for data centres

How To Buy A Designo Grille

High-efficient gas boiler CompactGas

SSG PRODUCTS FOR SHIPS AND OFFSHORE

BLADE S-MAX Cabinet for Blade Server

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

DIGITUS Network & Server Cabinets. UNIQUE Series

K17.12 Door closers K17. Doors

KONRAD. Hybrid Fancoil Series

THE FIRST OF A NEW CLASS OF PRODUCTS

Incubator with mechanical convection

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Brochure EX

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

STERILIZERS, LABORATORY DRYING OVENS

Modular Access Floor for Data Center. From Rack to Row to Room to Building

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition Rev

Energy Saving ECM Motors and Fans Ventilation Catalogue

Knürr Smaract. Knürr Smaract. CompactRack

automatic back-flush program non-spattering hot water delivery large boiler with one heat-exchanger per group, thermo-syphon system

High-speed spiral doors for deep-freeze applications. TK Series

Climate chamber with illumination

HERZ-Thermal Actuators

EC medium pressure axial fans. The effi cient system solution.

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

DSRQ - DSRSQ - DSRSQ-THERM

HP switch LP switch Discharge thermo Comp. Surface thermo

L_PTL12_C01_E_P_TOKIOK_L_PTL12_C01_E_P_TOKIOK :50 Seite 17. Leonard Hausgeräte 2012 Leonard domestic appliances 2012

Adsorption air dryers ADS 1 215

Morgue refrigeration unit

Combi Unit Genius. The energy efficient Building Service Centre

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

New: Standard Safety Light Grille. High-Speed Doors

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

PRODUCT DATA SHEET T-LIFT DESK

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

LABOKLAV. Autoclaves Made in Germany.

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

DRYPOINT RA REFRIGERATION DRYER RANGE

Elegance SC. Solar Control

HEAVY DUTY STORAGE GAS

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

CADB and CADT-D / DI / DC Series

NEW 3-PIPE ECOi MF2 SERIES

Material test chamber with mechanical convection

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

How To Make A Supply Air Ceiling

PLASTIC CONTAINERS CONTAINER HOLDING TROLLEYS CONTAINER HOLDING CABINETS PLASTIC DRAWER UNITS DRAWER UNIT HOLDER SHELVES FOOD CONTAINERS

VDL 53 - Vacuum drying oven for flammable solvents

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps.

PLUG and PLAY VRV Connection

emura Form. redefined.

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

Transcription:

Air Conditioning Cooling Heating Ventilation HVAC air curtains Type InduAir

The Energy Saving air curtain for Industrial Applications InduAir The solid, self-supporting housing of the energy saving air curtain InduAir, which has been developed for the industrial application, is manufactured from powder coated galvanized sheet steel or aluminium and can be mounted beside or above the plant gate. Standard finishing RAL 9002 (grey white). The InduAir blow out Jet-Flo is made of anodized aluminium finishing in device colour. A stainless steel design is also available on request. ackside bent high performance radial fans suck up the air via a powder coated galvanized sheet steel intake louver with optimum cross-section and an inflow jet form one side. The blow out is accomplished with the HVAC aerodynamic Jet-Flo high-pressure chamber system with a nearly non-dissipative adjustment range of the blow angle (40 ) and allows highest shielding performance with up to 40% less energy expenditure than traditional industrial air curtain systems. The single-surged anti-vibration radial fans that are supplied with alternating current (230V, 1Ph, 50Hz, IP44) are silent in the operation and provide the power-specific airflows. Airflow regulation via five-stage touch button control, safety class IP 23. Advantages of the InduAir: Aerodynamic Jet-Flo high-pressure chamber system Compact design Optimum working shield Lower noise level Lower energy consumption Can be horizontally and vertically used Easy to mounted Low investment Rapid amortization Significant energy saving Postbus 2 Telephone (+31) 255 52 24 20 E-mail info@hvac.eu VAT nr. NL-80760313201 The Netherlands Iban NL72ANA0537070028 ic ANANL2A V0411 2

HVAC aerodynamic Jet-Flo air curtain technology HVAC developed a new air curtain generation, using the Jet-Flo tubes, which have inside aerodynamically shaped and adjustable wings: leaving the tube, the air becomes an extra concentrated and condensed airflow like air below an airplane - wing, resulting in following unique characteristics: 40% less energy consumption compared to any other air curtain The only air curtain worldwide fully shielding an open entrance gap The only air curtain worldwide for heights up to 6 meter or any width Double adjustable; air velocity and blow out direction Much less air volume needed, resulting in a very silent operation No insects can pass through due to the concentrated air stream Architecture variety possible thanks to the compact Jet-Flo tube The tube is accurately to direct to building over-or under pressure The air stream can be adjusted towards winter- or summer mode Investment is earned back in < 2 years by the very high efficiency Noise level is upon the very lowest in the market ( 46 71 d(a) These unique characteristics make implementation of Jet-Flo air curtains possible in situations & business sectors, where this is hardly possible with air curtains, using conventional air-outlets: All industrial environments in general (shielding the internal air) Food industry (shielding entrances of cool- & deep freeze stores) Shielding neighbors against smell from garbage treatment plants Preventing smell to penetrate from one to next production process Creating strong air locks at entrances in heavy circumstances Shielding entrances at direct strong & cold sea winds (up to f 6!) Compensating losses & draft ( up to 20%) of revolving doors Compensating losses & draft (up to 50%!) of sliders at vestibules Decrease CO2 emission Our advice Explain us your specific problem and we will investigate which Jet-Flo air curtain configuration is the ultimate solution! Postbus 2 Telephone (+31) 255 52 24 20 E-mail info@hvac.eu VAT nr. NL-80760313201 The Netherlands Iban NL72ANA0537070028 ic ANANL2A V0411 3

Infrared photographs The infrared photographs show the temperature separation between the inner and outer environment. The Jet-Flo high-pressure chamber discharge system will create an optimal separation. Normal View Infrared views Closed door Open door without air curtain Open door with air curtain Normal View Infrared views Upper part Middle part Lower part Postbus 2 Telephone (+31) 255 52 24 20 E-mail info@hvac.eu VAT nr. NL-80760313201 The Netherlands Iban NL72ANA0537070028 ic ANANL2A V0411 4

A Specification Model Installation height max. m 5,5-6,0 Active part cm 100 150 200 250 300 350 400 450 500 550 600 Air flow m 3 /h 5.320 7.980 10.640 13.300 15.960 18.620 21.280 23.940 26.600 29.260 31.920 Air velocity highest stage m/s 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 lowest stage d(a)! 46! 46! 47! 47! 49! 50! 52! 53! 54! 55! 57 Noise level highest stage d(a) 60 60 61 61 63 64 66 67 68 69 71 V 230 230 230 230 230 230 230 230 230 230 230 Electrical Data kw 0,55 0,82 1,09 1,37 1,64 1,91 2,18 2,46 2,73 3,00 3,28 A 2,5 3,8 5,0 6,3 7,5 8,8 10,0 11,3 12,5 13,8 15,0 Weight kg 55 80 105 130 155 185 210 235 260 285 310 Width (A) mm 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Dimensions Height () mm Depth (C) mm InduAir 600 230+6 A 650 680 ø 12 50 C C Typical Applications Vertically blowing mounted abo Horizontally blowing from one side Horizontally blowing from both sides Postbus 2 Telephone (+31) 255 52 24 20 E-mail info@hvac.eu VAT nr. NL-80760313201 The Netherlands Iban NL72ANA0537070028 ic ANANL2A V0411 5

www.hvac.nl HVAC Nederland Postbus 2 1970 AA IJmuiden T (0255) 52 24 20 F (0255) 51 42 96 info@hvac.nl www.hvac.nl Ontwerp: OPZET - Santpoort Zuid K1308