FRANK Product List valid as of 1 April 2014 Intec injection hose system
Intec injection hose systems Intec injection hose systems ensure secure, simple and rapid sealing of horizontal and vertical construction joints. Intec hose systems have been valued by architects, clients and construction companies for over 20 years due to the technical advantages of the hoses over all other types of water stop. Metal clip Plastic clamp Schnappi tie Shutter connector Shutter spider An extensive range of Intec accessories ensure a quick and easy installation and injection process for the user. Various injection resins approved for hose and crack injection - also approved for drinking water applications - round off the range. Double shutter spider Access box Conical-head nipple Intec Premium Intec Standard Intec Cem N Intectin Blitz Intectin Plus Intectin EP Intectin Acrylic Resin Hand press Piston pump 100 www.maxfrank.com
Intec injection hose systems Intec standard injection hose (for single injections), for injection with resins only, tested and certifi ed to international construction standards. Intec Premium injection hose (for multiple injections) for initial and repeated injection with PUR resins, tested and certifi ed to international construction standards. Intec Cem N injection hose (for multiple use), I.D. 10 mm, for initial and repeated injections with resins and cements, tested and certifi ed to international construction standards. Accessories for Intec Standard and Intec Premium IVINTECN IVINTECP IVPSCEMN 100 lin. m/roll 100 lin. m/carton 50 lin. m/roll Shutter connector blue INPACKB 20 pcs./carton Shutter connector yellow INPACKG 20 pcs./carton Schnappi tie (suitable for green concrete or Ø 8 mm drill holes, approx. 6 per 1 m required) Metal clip with nail plug suitable for Ø 5 mm drill holes (approx. 6 per 1 m required) Intec clip made of plastic, with pre-fi tted nail, suitable for nail gun (approx. 6 per 1 m required) Metal clip with pre-fi tted nail, suitable for nail gun(approx. 6 per 1 m required) Foam plastic connector for taking up variation in spacing between shutter connector and formwork Napa shutter spider (adjustable) used to fi x the shutter connector to the reinforcement ISCHNC IMSCHEL IKSCHEL IMSHILT IDICHTI 20 pcs./bag INAPASP - Double shutter spider INAPADSP - Steel connector IVVPSL - Recessed access box with lid, for embedding and protected storage of the injection hose ends in the concrete Intec injection hose end pieces dia. 4 mm, breather tube with a steel connector piece and an end cap, length 400 mm Important instructions for injection hose laying Lay the injection hose centrally in the section. In case of wide sections (d > 60 cm), the injection hose should be located approx. 25 cm away from the water retaining face. The injection hose should not, under any circumstances, be too close to the future concrete surface or in contact with it. Concrete cover 50 mm The injection hose must not be located outside the wall. The injection hose must be securely fi xed, so that movement or fl otation is prevented (fi xing interval s 15 cm). The injection hose may only be used in construction joints, not in expansion joints. IVDOSE - IVERPE - A shutter connector or a breather tube must be connected to the beginning and to the end of each circuit. The length of the individual injection circuits should not be greater than approx. 10 m. To use greater lengths please contact our Technical Department. The shutter connector should be placed in a location which is easy to access at a later date. If there is heavy water outfl ow from the shutter connectors, screw the conical-head nipples into the shutter connectors in order to prevent them from clogging. Technologies for the construction industry 101
Accessories for Intec Standard and Intec Premium Internal hose end connector with conical-head nipple, incl. one hose clip, to fi t breather tube Water stop clip - for fi xing of injection hose to metal water stops Water stop clip 2 for elastomer waterbars, fi xation of injection hose Water stop clip 3 Wire clip for lateral fi xing of the Intec injection hose to a metal water stop Water stop clip 4 Wire clip for lateral fi xing of the Intec injection hose to a metal water stop Conical-head nipple with extra-long thread (1 piece per shutter connector required) Conical-head nipple without non-return valve, used only for fl ushing under pressure IINPACK - IFBK IFBK2 IFBK3 - IFBK4 - IRKKNI - IRKKNIN - Socket spanner for conical-head nipple ISTSKK - Hand pump complete with high-pressure armoured hose and grip valve, for resin injection only IHPRESS - Hydraulic manometer 0 to 160 bar IHMANOM - T-piece for connecting manometer to hand pump ITSTHM - Replacement sealing ring for the hand press IHPDICH - Grip valve fi ts conical-head nipple IEGRKOP - Replacement high-pressure armoured hose 500 mm long. The high-pressure armoured hose can also be inserted directly into the shutter connector. Adapter with 2 internal threads M10 x 1.0, used for extension of replacement high-pressure armoured hoses IHDPS0500 - IAHDPS - Mixer paddle for drill IRWBOR - Accessories for Intec Standard and Intec Premium Filament tape Designation Breather tube, inner diameter 4 mm, 25 bar Art. no. IENTLSL Filament tape IFIBAND roll à 50 m 102 www.maxfrank.com
Accessories for Intec Cem N inner diameter 10 mm Shutter connector ICEMPACK - Cut connector with 10 mm IG ISPACK2 - Metal clip with nail plug IMSCHEL18 Metal clip with pre-fi tted nail, suitable for nail gun Plastic coupling for Intec Cem N and breather tube Ø 10 mm Steel connector for Intec Cem N injection hose Connector for Intec Cem N or breather tube Ø 10 mm at M10 Double ear clamp Ø 17-18 mm for Intec Cem N and breather tube Ø 10 mm End piece with connector (M10) for common injection grips End cap for breather tube Ø 10 mm Adapter (M10 x 1.0 external / M6 external), connector between the Intec injection hose end (breather tube Ø 4 mm) and the fl at-headed nipple or between the disk packer/ screw packer dia. 13 mm and the fl at-headed nipple Adapter (M10 x 1.0 external / M10 x 1.0 external), connector between shutter connector and fl at-headed nipple Press-on coupling for use with fl at-headed nipple Flat-headed nipple with non-return valve Recessed access box with lid, for embedding and protected storage of the injection hose ends in the concrete Accessories for Intec Cem N inner diameter 10 mm Designation Breather tube Ø 10 mm, 25 bar ICEMHILT ICEM10K - ICEM1111AD - ICEM1011AD - ICEMS18 ICEMVER - IENTLK10 - ICEM1006AD - ICEM1010AD - ICEM10SK - ICEM10N - IVDOSE2 - Art. no. IENTLSL10 For further information on crack injection you can watch the detailed application video in our media centre at www.maxfrank.com. Technologies for the construction industry 103
Max Frank GmbH & Co. KG Technologies for the construction industry Mitterweg 1 94339 Leiblfi ng Germany Phone +49 9427 189-117 Fax +49 9427 1588 info@maxfrank.com www.maxfrank.com 925PL02/08 INT/GB 11/14