Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60



Similar documents
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Operating Instructions Drill rig DRU160

SunMaxx Solar Filling Station Operating Instructions

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code Machine-no.:

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Trouble Shooting. Pump

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

TRIMMING UNIT/DIAMOND MACHINE TST.13

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Rexroth Hydraulic Pump A10VO Series User Manual

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

IMPORTANT SAFETY RULES TO FOLLOW

User manual. Leather Side Drum

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

INSTALLATION INSTRUCTIONS

Manual piston sampler...m 11

Maintenance and Operating Instructions SIS 120P/SISF

Remote Head REMO ONE. Code Manual

Nexus FS Point of Use Installation Guide

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ELECTRIC KNIFE SHARPENER

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

M A N U A L

Assisted lift operated 2/2-way solenoid valves Type EV250B

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

V94 BULK TAPE DEGAUSSER

Installation Instructions for Water Methanol Stage 1

Stainless Steel Single and Dual Circulation Kits

Streaming Potential System (SPT1000, SPD1000)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

SWIMMING POOL HEAT PUMP Owners Manual

Oil and Coolant Circulating Heating System. Model - OCSM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Installation Instructions S

Series Hose Reels

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

VOYAGER 570G. 744A Sprayer Control

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Hydraulic control unit series

100 Series Maxi Internal Filters. Instruction Manual

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Product catalogue, pipe and sewer cleaning systems

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Please also see 10 golden rules for correct Saniflo installation on

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Cable Plug acc. to DIN EN , Form A

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Series 7500 Torque Sensor

Installation Instructions

Series 6000 Torque measured metal bellow coupling

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

OPERATING AND MAINTENANCE MANUAL

MAC FAUCETS. Owner s Manual. Models: FA444

CG PTFE Diaphragm Liquid Transfer Pump

FLEXIT S4 R S6 R S7 R

Electro-Pneumatic Bus Door Control Mechanism

Machine Documentation BELKI Oil Separator type 301

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Please keep this manual for f uture reference.

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Single sub-base valve

INSTRUCTION. Industrial Sewing Machines. No First published : June 1997 Second edition : March 2001

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

Section 5: Machine Overview

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

PBX Series Quick Fit Connector Bimetallic Steam Traps

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

1. Description. 2. List of Accessories included A B C F G H

Sport Ice Elektro 124

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS


USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

Operators manual Basic water heater

Daily Operator Checks. Monthly Maintenance

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

FG MOISTURE MONITOR Installation & Operation Manual

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Transcription:

Technology You Can Afford. Quality You Can Trust. Operating Manual Rotary Drum Filter Model: KC10 KC15 KC30 KC60 Koi-Collection Indonesia Tel./Fax: +62-21-82433766 Jl. Raya Parpostel 96 www.koi-collection.com Jati Asih, Bekasi 17423 Indonesia uci@koi-collection.com Page 1 of 29

1. Introduction Congratulations to your new Rotary Drum Filter (RDF). To make sure that your RDF works properly it is essential that you read this manual carefully. Please follow exactly all instructions, hints and information to avoid any problems with the operation of the RDF. Should any questions or problems occur which are not mentioned in this manual please contact your dealer. 2. Important Security Information And Warnings This manual should be accessible at any time as it contains important information regarding the operation and installation, as well as for trouble shooting. We recommend to keep a copy of this manual directly at the location of your filter, so that it is available for technicians etc., if necessary. PLEASE NOTE! Koi-Collection is not responsible for any damages of the RDF or injuries which occur due to neglect of the manual and the security notes and instructions contained in it. Page 2 of 29

3. General Information regarding the used Markings You will find the following markings in this manual. These markings point to important information or contain warnings. The exact meaning are described below as follows: i Important information that requires special attention. Danger due to electricity. Increased risk of damage/injuries for items or persons. 4. Manufacturer data Koi-Collection Indonesia Jl. Raya Parpostel 96 Jati Asih, Bekasi 17423 Indonesia Tel./Fax: +62 (0)21 / 82433766 E-mail: Web address: uci@koi-collection.com www.koi-collection.com Page 3 of 29

5. Information regarding your RDF model You will find the indication/data regarding your model on the identification label on your RDF. 6. EG-Conformity Statement Manufacturer: Machine type: Guide Lines/Directives: Koi-Collection Indonesia Jl. Raya Parpostel 96 Jati Asih, Bekasi 17423 Indonesia Rotary Drum Filter incl. electrical control unit (Model on the ID label) Machinery Directive EU 98/37/EC Low Voltage Directive 73/23/EEC The manufacturer herewith confirms the conformity of the product described in this manual with the above mentioned security directives and regulations. Jakarta, 1st August.2009 Fauzia Latief (President Director) Page 4 of 29

7. Modifications of the RDF Please note that any modifications on the RDF without written approval of Koi- Collection or an authorized dealer will result in the immediate expiration of the CEsign. Furthermore Koi-Collection will not be responsible for any damages or injuries resulting from these modifications. 8. Spare Parts Only genuine spare parts from Koi-Collection or an authorized dealer should be used. If spare parts from other suppliers/manufacturers are used, Koi-Collection will not be responsible for any damages/injuries. 9. Description and Function of the RDF A rotary drum filter (RDF) is a mechanical filter which removes waste and other fine particles from the pond water via a micro screen (filter screen). What makes the RDF so special is the ability to "monitor" the changes in water levels and "recognize" if the micro screen needs to be cleaned. Therefore a rotary drum filter automatically adjusts to the waste intake and only flushes if necessary. The other big advantage of RDF's is that all detritus such as fish waste, uneaten koi food etc. would not remain in the pond water. Instead all waste is flushed from the water column automatically after a very short period of time. The function principle of the RDF (gravity mode): 0 Gear Motor 1 Control unit 2 Sensor 3 Adjustable Overflow 4 Waste water outlet 5 Collecting chamber 6 Water Inlet 7 Water Outlet 8 Drum Tensioner 9 Filter Drum 10 Waste Water Tray 11 Spray nozzles Page 5 of 29

9. Description and Function of the RDF (continued) The (contaminated) water is fed into the RDF via the water inlet (6). The water flows into the collecting chamber (5) and from there into the inside of the filter drum (9). The filter drum is covered with a fine filter screen (standard 40 micron/300 mesh). The (contaminated) water can only leave the drum by passing through the filter screen. All particles larger than 40 microns will remain inside the filter drum. The mechanically clean water leaves the drum filter s chamber via the outlet(s) (7) and can then pass onto the following filtration states. The waste particles trapped inside the drum will slowly clog the filter screen making it mare difficult for the water to pass through it. Therefore the water level in the clean water chamber will slowly drop. Once the water level reaches a certain minimum level, which can be manually adjusted with the sensor (2) attached to the RDF, a flushing process is activated by the digital control unit. During the flushing process the drum (9) is rotated by gear motor (0) while high pressure water is sprayed onto the outside of the drum by multiple spray nozzles (11). The waste particles that were clogging the filter screen are flushed into a waste tray (10), positioned inside the filter drum, and leave filter via the outlet (4). The difference in water levels between flushing processes can be manually set by the sensor located an the outside of the filter. There is one sensor for gravity fed and another for pump fed systems. The flushing time can also be manually set with the digital timer an the control unit. Due to the use of the water level sensors the filter only flushes when necessary, i.e. when the waste intake reaches certain limits. Page 6 of 29

10. Transporting and moving the RDF The RDF can transported/moved by or fork lift or similar devices while standing on a pallet. To move the filter by hand the inlet and outlet sockets can be used (Please do not use the socket for the waste outlet!). 11. Installation and Connection The installation should only be executed by qualified personnel. We strongly recommend the installation and connection to be performed by your dealer! 11.1 Before the installation The RDF should be carefully inspected before the installation. Make sure that the packing and the RDF show no signs of any damage. Check the inside of the RDF and make sure that there are no remains or items in it. Furthermore the proper fit of the Teflon seals between the drum and the tension ring has to be checked (no gaps). Should the Teflon seals be too lose the tension ring can be tightened (not too tight) via the tension nuts. Page 7 of 29

11.1 Before the installation (continued) The correct fit of the chain and the drive gear of the motor should also be checked. Should the chain be too loose or too tight you can adjust the chain with the tension gear. In case of any damage please inform your local dealer immediately! 11.2 Installation and Connection The RDF needs to be placed on a solid and flat surface. When the filter has been placed at the desired location it needs to be set straight by using a spirit level. The RDF needs to be placed at a proper location and it must not be exposed to direct sunlight. The RDF has to be protected against freezing. Please make sure that the filter is protected against temperatures below -20 deg. Celsius (-4 deg. Fahrenheit). If the temperature might become lower the RDF needs to be covered accordingly. After that all inlets and outlets have to be connected to the sockets on the RDF. Make sure that the connected pipes do not create any mechanical load or tension onto the RDF casing. The connecting pipes should be as straight as possible (use as less elbows as possible). The pipe sizes should suit the desired flow rates. The pipe for the waste water should be installed with a decline of min. 1%.! Page 8 of 29

11.3 Installation level of the RDF (gravitation system) i The standard installation level of the RDF is 160mm above water level (top of the casing needs to be 160mm above water level). This is the optimum height if all relevant parameters are correct. As conditions on every pond may vary (piping, flow rates etc.) the following instruction is only a general advise. Should the water levels change too much after the installation, so that the water reaches the overflow or the waste water tray before the flushing starts, the sensors and/or the flushing time will have to be adjusted accordingly (longer flushing, less level difference). Should the sensor and/or flushing time adjustments still not solve the problem the RDF needs to be installed higher. The water level in the filter with pumps off should be 150mm below the upper edge of the filter casing (cover open). When pumps are running the adjustable overflow can be set 5 mm above the water level. Page 9 of 29

11.4 Connection of the flushing pump The jet pump can be either connected with pipes or suitable high-pressure hoses. The water inlet of the spray bar has a ¾ inch connector. A hose adaptor or pipe socket can be connected to it. The water outlet of the jet pump is connected to the spray bar. The water inlet of the jet pump is connected to the 1¼ inch (1 inch on the KC10) connector at the bottom of the drum chamber. This makes sure that only prefiltered water is fed into the pump and the spray nozzles won t get clogged. To connect the outlet of the flushing pump a connector for a water hose or pipe needs to be fitted at the nozzle bar. 11.5 Power connection The control unit is completely assembled and fitted onto the casing of the RDF. To connect the control unit simply put the plug into a plug socket. The plug of the flushing pump needs to be put into the blue socket on the control unit. Before connecting the plugs please make sure that all casings of the control unit are properly closed. Before start-up and connecting the plug make sure that the emergency stop button is pushed and the power supply is interrupted until start-up. PLEASE NOTE: The control unit is completely installed and ready-to-use. However it is recommended that a qualified electrician rechecks the power connection. We also recommend to connect the control unit to a FI-switch for further safety. Page 10 of 29

12. Start Up 12.1 Before start up It is important to re-check all relevant points again. This includes: -Checking all connections (correct position, no leakages etc.) -Checking all safety devices (Motor cover etc.) 12.2 Start up (Gravitation system) This chapter is important if you have installed your RDF as a gravitation system. If this is not the case and you have installed your RDF in pump fed mode please continue under 12.3. Make sure that all pumps etc. are turned off and the pond system is on stand-by. Open all cranes gate valves etc. If there are any cranes installed at the flushing pump, they need to be opened as well. After the water level has set in the RDF (the level in the collector chamber and the filter chamber have to be the same) the water level has to be below the edge of the overflow in the collector chamber (please refer to 11.3). Page 11 of 29

12.2 Start up (Gravitation system) continued Please adjust the distance of the sensors with the sensor nuts so that the sensors are positioned approx. 4-5 mm in front of the acrylic pipes (please see picture) Now adjust the sensor on the left side (cable with blue marking) until the center of the sensor is positioned approx. 5-6 cm below the actual water level. The sensor will give the signal for flushing if there is no water in front of it. Please avoid to put the sensor more than 10cm below water level to avoid additional tension on the drum and micro screen. If the sensor is in the correct position it can be tightened with the screws. The sensor for the min. water level needs to be put approx. 3-5 cm below the flushing sensor. Should the water level drop until there is no water in front of the min. water level sensor the control unit will switch to safe mode (red light will turn on). This feature protects the filter components such as motor, transformer, pump etc. from any damages. To protect you pond pumps, UV lights etc. we recommend to install a pump protector (can be purchased on request). In case the control unit switches to safe mode your pumps, UV lights etc. will also be turned off automatically. Please ask your dealer for more info. Page 12 of 29

12.2 Start up (Gravitation system) continued Set the black switch on the control unit to the position Gravity Mode. Turn the control unit on by turning the red emergency-stop-button (the pumps of your pond should still remain turned off at this stage!). Page 13 of 29

12.2 Start up (Gravitation system) continued Now you can adjust the sensitivity of the proximity switches (the sensors are preadjusted before delivery but they might require re-adjustement due to different parameters). If water is in front of the sensor (in the acrylic pipe) the LED light should be on. If this is not the case turn the screw on the potentiometer slowly clockwise until the diode turns on. After the LED turned on turn the screw clockwise for another half revolution. After that push the sensor to the top until there is no water in front of it. The LED light should turn off. Should the LED light not turn off please turn the adjusting screw slowly counter clock wise until the LED turns off. After the adjustment the LED light should turn on with water in front of it and turn off with no water in front of it. Proceed this way with all sensors. Page 14 of 29

12.2 Start up (Gravitation system) continued Open the cover of the RDF and push the green button for the manual flushing (because the cover is open the drum will not turn). Check that the flushing works and the nozzles are not plugged. If you find plugged nozzles push the emergency-stopbutton and remove the nozzles from the nozzle holder by turning them counter-clockwise (¼ turn). Be careful when taking out the nozzles and make sure the seals do not fall into the RDF. Clean the nozzles and put them back in position. Turn the control unit on again by turning the emergency-stop-button. Turn on the water pumps of your pond and check if the cleaning and flushing process works and the filter operates according to its application. Depending on the flow rates of the water pumps and changes in water levels you might have to readjust your sensors again. After flushing please check the position of the adjustable overflow. The top of the overflow should be positioned 5-10 mm above the water level. Automatic water re-fill: The KC series RDF is equipped with a sensor (cable with yellow marking) that can control a 24V solenoid valve/magnet valve (not included) to automatically re-fill the pond water and keep the water in the pond at the same level. The solenoid valve has to be connected to the corresponding cable on the control unit (cable with a white connector and yellow marking) The sensor needs to be adjusted so that the LED light will turn off as soon as there is no water in front of the sensor anymore. The sensor will open the solenoid valve once it has no water contact for more than 20 seconds (the time can be changed on the control unit) and close it once the water level has reached the sensor again. Page 15 of 29

12.2 Start up (Gravitation system) continued PLEASE NOTE: If you do not use automatic water re-fill it is very important that the water level in the pond does not get too low. If the water level gets too low it is possible that the water cannot touch the sensor anymore. In that case the RDF will not stop flushing and the control unit will switch to failure mode after a certain time to protect the RDF and the components (motor, trafo, jet pump etc.) Page 16 of 29

12.3 Start up (Pump fed mode) IMPORTANT NOTICE FOR OPERATION IN PUMP FED MODE: The connections on the inlet side will need to be reduced to the size of your pump outlet(s). Any inlets which are not used will need to be closed with caps! The outlets of the RDF have to be raised with T-pieces so that the bottom of the outlet(s) are at least at the same level like the waste water outlet! This makes sure that the filter chamber does not get entirely empty during a power failure. Furthermore critical differences in water levels inside and outside of the filter drum are avoided. Page 17 of 29

12.3 Start up (Pump fed mode), continued Turn on the water pump(s) of your pond and wait until the water comes out from the outlets of the filter. Turn the pumps off again. Mount the flushing sensor (cable with blue marking) on the right side of the holder (please see picture on the left side). Make sure that the distance of the sensor to the acrylic pipe is correct (please refer to the picture on the right side). The sensor for the automatic water re-fill (yellow marking) is usually not in use in pump mode. In that case the sensor is positioned on the bottom of the holder (please see picture on the left). If an automatic re-fill is required the sensor needs to be mounted at the pond. Please contact your dealer for further details. The sensor for the min. water level needs to be installed so that the pond level can be monitored. Should this not be possible it could be mounted in front of the acrylic pipe so that it has permanent water contact. In this case it is possible that your pond pumps empty the whole pond when the control unit switches to safe mode. In case the min. water sensor is not installed to monitor the actual pond level Koi-Collection will not be responsible for any damages. Please contact your dealer for further info. Page 18 of 29

12.3 Start up (Pump fed mode), continued Set the black switch on the control unit to the position Pump Mode. Turn the control unit on by turning the red emergency-stop-button (the pumps of your pond should still remain turned off at this stage!). Page 19 of 29

12.3 Start up (Pump fed mode), continued Now you can adjust the sensitivity of the proximity switches (the sensors are preadjusted before delivery but they might require re-adjustement due to different parameters). If water is in front of the sensor (in the acrylic pipe) the LED light should be on. If this is not the case turn the screw on the potentiometer slowly clockwise until the diode turns on. After the LED turned on turn the screw clockwise for another half revolution. After that push the sensor to the top until there is no water in front of it. The LED light should turn off. Should the LED light not turn off please turn the adjusting screw slowly counter clock wise until the LED turns off. After the adjustment the LED light should turn on with water in front of it and turn off with no water in front of it. Proceed this way with all sensors. Page 20 of 29

12.3 Start up (Pump fed mode), continued Open the cover of the RDF and push the green button for the manual flushing (because the cover is open the drum will not turn). Check that the flushing works and the nozzles are not plugged. If you find plugged nozzles push the emergency-stop-button and remove the nozzles from the nozzle holder by turning them counter-clock-wise (¼ turn). Be careful when taking out the nozzles and make sure the seals do not fall into the RDF. Clean the nozzles and put them back in position. Turn the control unit on again by turning the emergencystop-button. Turn the pump(s) on. Now adjust the sensor on the left side (cable with blue marking) until the center of the sensor is positioned approx. 5-6 cm above the actual water level. The sensor will give the signal for flushing if there is water in front of it. Please avoid to put the sensor more than 10cm above water level to avoid additional tension on the drum and micro screen. If the sensor is in the correct position it can be tightened with the screws. Check if the cleaning and flushing process works and the filter operates according to its application. Depending on the flow rates of the water pumps and changes in water levels you might have to re-adjust your sensor again. After flushing please check the position of the adjustable overflow. The top of the overflow should be positioned 5-10 mm above the water level. To protect you pond pumps, UV lights etc. we recommend to install a pump protector (can be purchased on request). In case the control unit switches to safe mode your pumps, UV lights etc. will also be turned off automatically. Please ask your dealer for more info. Page 21 of 29

12.4 Start up Setting Parameters The following parameters can be adjusted on the control unit: -Flushing time (=B5 at the PLC unit), pre-set to 4 seconds -Flushing time after 1 hour in case the sensor did not trigger flushing due to low waste intake (maintenance flushing), (=B18 at the PLC unit), pre-set to 8 seconds -Hysteresis (time between the sensor got no water contact and the signal to open the solenoid valve) to re-fill fresh water (=B20 at the PLC unit), pre-set to 20 seconds The details how to change the parameters are described on the following pages. Page 22 of 29

Setting the flushing time (B5): Original Display Press New Display Or Page 23 of 29

12.4 Start up Setting Parameters (continued) Setting the maintenance flushing time after 1 hour (B18): Original Display Press New Display 3x Or Page 24 of 29

12.4 Start up Setting Parameters (continued) Setting the hysteresis for the re-fill (B20): Original Display Press New Display 2x Or Page 25 of 29

12.5 Start up General information i On new ponds it is possible that the spray nozzles get plugged more often during the start up period (approx. 1-2 weeks) because the pond and chambers might still contain waste from the construction. In the first days after the start up it is recommended to check the nozzles on a daily basis and clean them if necessary. After the start up please make sure that the flushing starts before the water reaches the overflow or waste water tray inside the drum. If necessary the sensor has to be re-adjusted so that the level difference between collector chamber and filter chamber is lower (in gravitation mode the sensor needs to be raised a little, in pump fed mode the sensor needs to be lowered a little). After approx. 2 weeks the flushing frequency should be checked. In clean ponds the time between 2 flushing modes should not be less than 15 minutes. If the flushing frequency is too high (less than 15 minutes between 2 time flushing) the flushing time or the sensor level difference can be increased. If you face problems with the setting or flushing times please contact your local dealer. 13. Maintenance Before doing any maintenance works the emergency-stopbutton has to be pushed and the plug of the control unit has to be removed from the plug socket! Failing to do so might result in damages or injuries! 13.1 Spray nozzles It might happen that one or more nozzles get plugged. This results in a poor cleaning of the filter screen and a higher flushing frequency. Should a nozzle be plugged you can clean it with a tooth brush. Please do not use any hard or sharp objects like cutter knifes or steel brushes as they would damage the nozzles. Page 26 of 29

13. Maintenance (continued) 13.2 Chain and drive gear The chain and the gear are made of stainless steel and do not require any maintenance. An elongation of the chain can be expected only after many years of operation as the mechanical load is very low. If the tension of the chain should be too low it can be adjusted with the tension gear. 13.3 Filter screen Should the filter screen be torn or damaged it can be changed easily. To change the screen the fixing screw of the drive gear has to opened so that the drum can move freely. After that the screws of the outer support mesh can be opened and the mesh including the filter screen can be removed. The spare filter screens of Koi-Collection are supplied with a separate manual and can be installed easily. When the new screen is installed and all screws of the support mesh are tightened the drum has to be turned so that the gear reaches the correct position on the pivot rod (screw above the flattened part of the rod) the fixing screw of the gear can be tightened again. Page 27 of 29

14. Technical Specification KC10 KC 15 Dimensions Casing (without cover and connections): Length: 454mm (17.88 inch) Width: 504mm (19.84 inch) Height: 510mm (20.10 inch) Length: 604mm (23.78 inch) Width: 504mm (19.84 inch) Height: 510mm (20.10 inch) Dimensions Filter Drum: Dia.: Width: 360mm (15.75 inch) 204mm ( 8,03 inch) Dia.: Width: 360mm (15.75 inch) 324mm (12,76 inch) Surface area filter screen (gross): Surface area filter screen (net): Mesh size filter screen: Max. Flow Rate: Dimensions Inlet and Outlet: Inlet: Outlet: Waste Water Outlet: Connection jet-pump: Connection spray bar: Motor: Electrical Supply Sensor/Motor: Classification Control Unit Casings: Classification Buttons/Switches Control Unit: Installation Height above water level: Electrical Supply Control Unit: Power Consumption Control Unit (standby): 0,204 m² (2,20 square feet) 0,183 m² (1,97 square feet) Mesh/micron: 300/40 10 m³/h (2,630 gallons/hour) 1 x 110 mm (4 inch) 1 x 110 mm (4 inch) 1 x 90 mm (3 inch) 1 inch 3/4 inch Wiper Motor 18 Watt 0,339 m² (3,65 square feet) 0,305 m² (3,28 square feet) Mesh/micron: 300/40 15 m³/h (3,950 gallons/hour) 2 x 110 mm (4 inch) 2 x 110 mm (4 inch) 1 x 90 mm (3 inch) 1 inch 3/4 inch DC Motor 60 Watt, 3150 rpm, Torque 15 Nm (132 lb/in) with worm gear box and thermo switch 24 Volt / 24 Volt IP66 IP65 160 mm (6,3 inches) 220V / 50Hz (standard model) 110V / 60 Hz (US model) Approx. 25 Watt Materials of Construction: HDPE: Stainless Steel: Teflon: PVC: Aluminum: PP: Casing, Filter Drum, Support Screen, Waste Water Tray etc. Micro Screen, Drive gear, Chain, Screws, Motor Pivot Rod Bearing seals Waste water pipe, Drum gear, tensioner Edge Protectors of the casing Spray Nozzles Page 28 of 29

14. Technical Specification (continued) KC30 KC 60 Dimensions Casing (without cover and connections): Length: 765mm (30.12 inch) Width: 604mm (23.78 inch) Height: 610mm (24.02 inch) Length: 1005mm (39.57 inch) Width: 754mm (29.69 inch) Height: 760mm (29.92 inch) Dimensions Filter Drum: Dia.: Width: 460mm (18.11 inch) 454mm (17,87 inch) Dia.: Width: 610mm (24.02 inch) 674mm (26,54 inch) Surface area filter screen (gross): Surface area filter screen (net): Mesh size filter screen: Max. Flow Rate: Dimensions Inlet and Outlet: Inlet: Outlet: Waste Water Outlet: Connection jet-pump: Connection spray bar: Motor: Electrical Supply Sensor/Motor: Classification Control Unit Casings: Classification Buttons/Switches Control Unit: Installation Height above water level: Electrical Supply Control Unit: Power Consumption Control Unit (standby): 0,621 m² (6,68 square feet) 0,559 m² (6,02 square feet) Mesh/micron: 300/40 30 m³/h (7,895 gallons/hour) 3 x 110 mm (4 inch) 3 x 110 mm (4 inch) 1 x 110 mm (4 inch) 1 1/4 inch 3/4 inch DC Motor 90 Watt, 3150 rpm, Torque 15 Nm (132 lb/in) with worm gear box and thermo switch 1,245 m² (13,40 square feet) 1,121 m² (12,06 square feet) Mesh/micron: 300/40 60 m³/h (15,790 gallons/hour) 2 x 160 mm (6 inch) 2 x 160 mm (6 inch) 1 x 110 mm (4 inch) 1 1/4 inch 3/4 inch DC Motor 180 Watt, 3050 rpm, Torque 20 Nm (117 lb/in) with worm gear box and thermo switch 24 Volt / 24 Volt IP66 IP65 160 mm (6,3 inches) 220V / 50Hz (standard model) 110V / 60 Hz (US model) Approx. 25 Watt Materials of Construction: HDPE: Stainless Steel: Teflon: PVC: Aluminum: PP: Casing, Filter Drum, Support Screen, Waste Water Tray etc. Micro Screen, Drive gear, Chain, Screws, Motor Pivot Rod Bearing seals Waste water pipe, Drum gear, tensioner Edge Protectors of the casing Spray Nozzles Page 29 of 29