Process Instrumentation



Similar documents
CHROMOCTANE O N LINE ANALYZER

Tracer Detection Systems

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

On-line Dissolved Gas Analysis

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Analytical Service Certification Program

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

TABLE OF CONTENT

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Buckeye Detection Systems Fixed Detection Systems Application Survey

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

Fire & Security DETECTORS

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Get the Right GC for Your Industry

PLCs and SCADA Systems

Chromatograph Maintenance and Troubleshooting Class # 5050

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Dew-Point Measurement Solutions

API Marine. BMS Presentation. Ballast Measurement Systems

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

NEW. EVEN MORE data acquisition and test stand automation

Process Gas Chromatograph

Gulf Coast Conference Prepared by: A. Coderre (Clearstone Engineering Ltd)

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Thermal Conductivity Detector

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

Rosemount Analytical 1500XA Process Gas Chromatograph

Danalyzer Model 700 Gas Chromatograph

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

NATIONAL FIRE ALARM AND SIGNALING CODE

Application Requirement

Tank Gauging & Inventory Management Solutions

Intelligent Device Management with DCS, PLC, and RTU

Technical Support Information No. 113 Revision 2.0 March 2005

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

COMOC-V. Operational and Technical Overview

T a b l e o f C o n t e n t s

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Triple Waveband Infra-Red Flame Detection

Transformer Oil Gas Analysis

Combined Cycle Control Overview

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

How To Use Safety System Software (S3)

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

23 The Thermal Conductivity Detector

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Model: DC-A2IO Advanced HVAC Controller

Medical Air Systems: Scroll

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Semaphore T BOX Applications in Data Center Facilities

How To Use A Ds340 (Dsp)

The Ambient Air Monitoring System

Industrial Strength Leak Detection

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Fundamentals of Gas Chromatography

IntesisBox Modbus Server Fidelio IP

EXPLORER 4 MULTIPOINT

sierra monitor corporation Fire and Gas Detection Systems

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Square D Power Management Services. Complete Custom Solutions for Your Power System

Cable Network Transparency Unified Monitoring System UMS

CO2 Alarm. Operation. Application

INSTRUMENTATION AND CONTROLS

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

PLAN REVIEW GUIDE FOR FIRE ALARM

World s Best Oil in Water Analyzers

NETWORK ENABLED EQUIPMENT MONITOR

Industrial Control Solutions

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

SECTION DETECTION AND ALARM

Analytical Products and Solutions. Complete service and maintenance solutions for your analytical equipment. usa.siemens.com/analyticalproducts

Micro Motion 3098 Gas Specific Gravity Meter

Executive Summary. Technical Description

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Process Alarm Solutions

Digital Controllers ACTUATOR COMPATABILITY

Communication Interface Units. CIU Prime & CIU Plus

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Remote monitoring & control solutions for cathodic protection rectifier

Siemens Vendor Training Maxum Process Gas Chromatograph

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

Fiber Optic Distributed Temperature Sensor (B-DTS)

Easy and efficient asset management for your business

Fire detection equipment

Transcription:

Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION

Process Gas Chromatography Features of Process Chromatographs Agilent 7890A gas chromatograph Complete range of detectors (FID, PDHID, MS, TCD, ECD, and PFPD) Fully developed and supported analytical methods Capillary columns and temperature programming Electronic pressure control Custom sample systems (gas, LPG and liquid phase streams) Digital outputs (MODBUS) Analog outputs (4-20 ma) Remote supervision Custom calculations Agilent ChemStation Wasson-ECE Instrumentation offers process solutions. The need for an accurate, precise, dependable, on-line analysis increases every day. Process control demands the best technology to maximize its effectiveness, and that means being able to deploy the most advanced process analyzers. Wasson-ECE represents a new generation in on-line technology, providing unparalleled capability and performance. Why a Wasson-ECE process solution? When you call us to discuss your analytical needs, Wasson-ECE will provide you with a free consultation that will help you decide what system works best for you. This includes deciding everything from how many sample streams to what types of GC detectors are required to analyze your process. Detailed discussions provide you with a process analyzer that is tailored to your analytical needs, saving time and money. The system will be shipped to your facility and our service engineers will install and train your personnel on the new on-line analyzer. All of our systems come with a one year warranty, including support. If you run into problems with your system you can contact us at any time, and we will provide you with the support that you deserve. We are a US based company that can provide you with the service you have come to expect. WASSON - ECE INSTRUMENTATION Process GC

Process Gas Chromatography Process Diagram Process Environmental On-line Agilent Control 7890N Our analyzer shelters are air conditioned and A Flame heated Ionization to yield Detector a consistent (FID) used operating to environment. detect the C 1 through The Cair 7 paraffins conditioner and olefins and heater to a lower are detection fully rated limit of for 20 duty ppm, in except Class for I, Div 2, trace Groups peaks eluting B, C, & on D the rated tail of areas. a major In systems component. used in hot, humid locations, dehumidifiers and hot-bypass options are available. On-line Lab Class I Div II Cabinet Central Server / DCS Sample On-line Agilent System 7890N Integration Our sample systems can accomodate up to twelve A Flame different Ionization Detector streams (FID) including is used to calibration detect the C blends. 1 through CStream 7 paraffins selection and olefins is controlled to a lower detection with double limit of block 20 ppm, and except bleed for valves trace peaks to prevent eluting on cross the tail contamination of a major and carry-over. comp-nent. Sample system control is provided through Wasson-ECE s process control software WinIStatus. Work Station Work Station Method On-line Support Agilent 7890N Start with the best chromatograph and add the best application technology. We ve designed our process gas chromatograph with an emphasis on custom, guaranteed analyses. We can mold our system to meet your specific analytical and communication needs. We add custom valving, columns, additional detectors, and auxiliary ovens to provide concise separations and analyses that are sophisticated, yet rugged enough for on-line use. With the same method on-line as in the lab, the A Flame lab Ionization system can Detector be used (FID) is to used support to the on-line detect the systems. C 1 through Any C 7 paraffins unusual and data olefins can be explored to a lower detection in the lab limit and of 20 methods ppm, except can for be tested trace peaks in the eluting lab on before the tail being of a major moved to process. component. Ph. 970.221.9179 www.wasson-ece.com

Process Gas Chromatography Stand-Alone Cabinet The stand-alone cabinet is a hazardous rated Class I, Division 2, Groups C & D process enclosure. The cabinet has its own purge system with a pressure switch and interconnect, which will remove power upon loss of purge. An air conditioner and heating system is placed directly outside eliminating the need for an additional shelter. The sample system is mounted to the outside of the cabinet, providing access to twelve different process streams and calibration standards. The streams are multiplexed using double block and bleed valving to eliminate cross contamination and carry-over. The stand-alone cabinet can be upgraded to work in Group B areas. On-Line Lab The on-line lab can be purchased as a complete package including the hazardous rated building with sample system and gas chromatographs mounted inside, or we can retrofit your existing shelter or laboratory. The instrument shelter is air conditioned, heated, and purged. NFPA X and Z purges are available. Hydrocarbon sensors are mounted in the shelter, along with oxygen and carbon monoxide monitors. The exterior of the instrument shelter is rated for service in hazardous areas Class I, Division 2, Groups C & D. The interior of the shelter is rated for general purpose. Eclipse Wall Mount Eclipse is the world s most advanced wall mount process gas chromatograph. Utilizing the latest technology in high-speed programmable oven GC, Eclipse gives you the ability to perform more complex chromatography on-line. The advanced electronic pressure control insures that consistent retention times are achieved, even when running very fast capillary analyses. Now you can tap into the latest in sampling systems, detectors, and column technologies with the new Eclipse Process Analyzer. WASSON - ECE INSTRUMENTATION Process GC

Process Solutions Process Decision Diagram Sheltered Is the instrument standalone or sheltered? Stand-alone Is the building general purpose rated inside? Yes Will the technician routinely interface with the GC? Is the Area Rated? No Yes No Yes No Is the building temperature controlled? On-line Lab Non-rated cabinet or Eclipse Rated Therostated Cabinet Non-Rated Thermostated Cabinet Yes No Eclipse Class I, Div 2 Group C & D Cabinet Ph. 970.221.9179 www.wasson-ece.com

Process Data Communications Process data can be transfered through an analog or digital format. Stream data flows automatically to a Distributed Control System (DCS), a Programmable Logic Controller (PLC), or a Laboratory Information Management System (LIMS). Analog 4-20mA The most common implementation of the analog format is the 4-20 ma current loop signal. In this case, one signal is required for each analyte in each stream and the resulting analyte concentrations can be independently scaled onto their respective 4-20 ma signals. The DCS will perform level alarming, data archiving, and data trending. This method is simple, but requires a lot of cabling as one wire pair is needed for each 4-20 ma signal. MODBUS One of the most common digital formats is MODBUS, which is a family of polled serial interface protocols. The hardware can be configured as single instrument RS422, multidrop RS485 or single instrument fiber optic RS232. Local Area Network (LAN) Various LAN interfaces are supported by our on-line systems including simple network file transfer where the data can be a text file or site specific FTP format, OLE for process control (OPC), and Distributed Component Object Model (DCOM). Local Data Storage Our on-line systems also incorporate their own local data storage. Chromatograms for all runs are stored for one month. Component reports are automatically appended to our WinVision database that can be extracted with our search engine or Microsoft Access. WASSON - ECE INSTRUMENTATION Process GC

Lab Analysis to Process Analysis Move a lab analysis to a process analysis. Wasson-ECE can take your lab analysis and move it to a process analyzer. We can either use your existing analysis method or we can create a custom method tailored specifically for the stream you need to analyze. Once your 7890A GC has been placed inside of our hazardous rated process enclosure the analysis of your process stream will run continuously. The data will stream back to your DCS or your lab as the analyses are performed. This helps you to make informed decisions about your process. Agilent 7890A Gas Chromatograph Advantages to Using a Agilent GC On-Line: Analytical capability equivalent to a lab instrument Process GC data is consistent with lab data Flexibility through a wide range of detectors, valves, and columns Built-in calibration system Remote supervision Custom analytical methods Custom sample systems Method compatability between lab and process One year warranty and instrument support Wasson-ECE 7890A Process Enclosure Ph. 970.221.9179 www.wasson-ece.com

Hazardous Rated Cabinet Layout Class I Division 2 Process Cabinet Layout WASSON - ECE INSTRUMENTATION Process GC

On-line Lab Layout Typical On-line Lab Bench Layout Agilent 7890 Manual Pnuematics Panel Agilent 7890 Auxiliary Oven Agilent 7890A Mini Tower Computer Agilent 7890A Monitor Wasson-ECE Electrical Distribution Box Class I Division 2 Hazardous Rated Sample System Layout Ph. 970.221.9179 www.wasson-ece.com

Process Questionnaire Typical information needed to generate a quotation for a process instrument. 1. What is the area classification? a) Class I, Division 2, Group C or D b) Non-Hazardous c) Other - Please Specify: 2. Will you need a building or a process cabinet? 3. Do you need cabinet temperature control and sunscreens? 4. What communication format will you need? a) 4-20 ma Outputs b) Modbus c) LAN d) Other 5. What are the local conditions like in your area? Ambient Temperature: Average Min Max 6. Do you need post run calculation software? a) BTU, Specific Gravity, etc... b) Database trending of results 7. How many sample streams will you analyze? 8. Will any of the following be present in your sample stream? a) Corrosives b) Moisture/Water c) Particulates d) Oils/Heavies c) Precipitates d) Oligomers, Polymers 9. Please list the components in your stream in the table below. Component, M.W. Typical Conc. Min Conc. Max Conc. Conc. Units Needs Quantified? Yes/No Attach additional sheets as necessary. WASSON - ECE INSTRUMENTATION Process GC

Conclusion Thank you for your interest in Wasson-ECE Instrumentation We strive to provide you with the best analytical solution. All of our applications are backed by a one year warranty on hardware and application. This guarantee helps you to purchase with confidence. Once you purchase, our service team is available to assist you should a problem arise. Call now to discuss your chromatography requirements. We also configure refinery gas, simulated distillation, detailed hydrocarbon analysis, high purity chemicals, natural gas, and customer specific configurations to meet your needs. Why Wasson ECE Instrumentation? A one year warranty on all Agilent and additional installed hardware. One year guaranteed analytical system performance. On-site installation and training. We specialize in creating custom solutions, please contact us today to discuss your unique chromatography requirements. Wasson-ECE Instrumentation 101 Rome Ct Fort Collins, CO 80524 (970) 221-9179 tel (970) 221-9364 fax marketing@wasson-ece.com Ph. 970.221.9179 www.wasson-ece.com

Engineered Solutions, Guaranteed Results. Ph. 970.221.9179 Fx. 970.221.9364 www.wasson-ece.com sales@wasson-ece.com