PMI-IF-H High Efficiency Gas Heat Units

Similar documents
Mechanical Rooftop Custom Capabilities

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Bring the fresh in. Dedicated Outside Air Systems

Radiant Panels and Chilled Sails.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Building Energy Systems. - HVAC: Heating, Distribution -

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

How To Buy A Lennox Power System

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Johnson Air-Rotation Systems

DOAS UNITS. MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR. Kitchens Hotel Corridors Laboratories. Paint Booths. Capacities Tons MBH

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

RPV - RP - RA air handling units

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Glossary of Heating, Ventilation and Air Conditioning Terms

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Glossary of HVAC Terms

Condensing Boiler Efficiency

Steam System Efficiency. Bill Lumsden Leidos Engineering

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

Energy Efficiency in Industrial HVAC Systems

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Annual Service Agreement

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

Basics of HVAC Cleaning

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

HVAC Systems: Overview

HVAC Basic Science - System Capacity

B.C. Buildings Corporation. Mandatory Preventive Maintenance Standard. To Meet Section 4.78 of the WCB OH & S Regulation

GTS Gas-to-Steam Humidification System

ENHANCED LABORATORY HVAC SYSTEM

CE6500 Energy Recovery Ventilator

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

HVAC Checklist - Long Form

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

Geothermal Comfort Systems

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

(Adopted December 1, 1978)(Amended July 8, 1983)(Amended November 6, 2009) (Amended September 5, 2014)

Active & Passive Beams

Creating Efficient HVAC Systems

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Defining Quality. Building Comfort. Heating and Cooling Coils

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Gas Furnace Upflow

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Innovent LASER Packaged Fresh Air Conditioning Units

Nordic Heat Pump Product Guide

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Aurora Mall. Aurora (Denver), Colorado

Comfort you can count on.

GAS CONVERSION PROJECT ˆAn Alternative to Oil

CHAPTER 9: WATER HEATING

HVAC Systems in Schools & Commercial Buildings and Radon

Originators of the Flexible Water Tube design

Element D Services Heating, Ventilating, and Air Conditioning

Exhibit IV Approved Measures List. Page 1 of 5

Defining Quality. Building Comfort. Precision. Air Conditioning

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Modular Make-Up Air Unit

Hot Water Heating: Technologies and Use

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

1.2 Refrigerant Equipment. General

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Chilled Water HVAC Systems

Displacement Ventilation in Schools

Diagnostics for Mobile Homes: HVAC

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Standard Heating and Air, Inc Committed to Excellence

Commissioning - Construction Documents (Page 1 of 6)

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

SECTION HEAT PUMPS

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Why Daikin? 2015 Houston, Texas USA

BSD Technical Standard Division 23: HVAC

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

Transcription:

PMI-IF-H High Efficiency Gas Heat Units

Mechanical High Efficiency Gas Fired Make-Up Air Units Price s new line of high efficiency indirect fired gas heating products are designed to meet the goals of all good building designs by reducing operating costs and minimizing environmental impact. The Challenge Table 1 Std Unit MUA Unit Design Conditions Btu/h-cfm Cooling Work Heating Work Watts/cfm Btu/h-cfm 80/67 to 57.6/57F 30 3.0-1.5 to 70F (20% OA) 16 19 90/75 to 55/54.5F 70 7.0-1.5 to 70F 78 97 Almost all building heating systems are based on burning natural gas. Typically, the most energy intense unit in the HVAC system is the make-up air unit (see Table 1) which uses as much as five times the natural gas of a standard unit. While plentiful, the cost of natural gas is rising. Even though natural gas burns twice as clean as coal and other fossil fuels, it still contributes to climate change through CO 2 emissions. The challenge is to improve the gas heating efficiency which will reduce operating costs and climate change impact. The Solution Typical Make-Up Air System Price s new line of high efficiency indirect fired units can help reduce operating costs by 11% with a less than two year payback. Traditional gas heat units are only 80% efficient, meaning 20% of the available heat in the natural gas is going up the vent stack. The stack temperature on a traditional unit can be over 500 F that s heat that s not available for the building and higher CO 2 emissions that lead to climate change. The Price line of high efficiency units have an impressive stack temperature of only 100 F, and they are 90% efficient so almost all of the heat released during combustion is used in the building. 1 priceindustries.com

PMI-IF-H High Efficiency Units High Efficiency Indirect Fired Furnace At the heart of the high efficiency unit is the new indirect fired convoluted tube furnace. The furnace includes a specially designed heat exchanger to squeeze as much of the heat from combustion as possible and transfer it to the supply air stream. The furnace is constructed from stainless steel and other corrosion-resistant materials to provide reliability and longevity. Indirect Fired Design The furnace is indirect fired, meaning no products of combustion enter the supply air. This helps maintain good indoor air quality. The burners are modulating which also allows for great temperature control and comfort. Indirect Fired Design Model Input Btu Output Btu Turndown PMI-IF-11-150H 150,000 135,000 5:1 PMI-IF-11-200H 200,000 180,000 5:1 PMI-IF-11-300H 300,000 270,000 5:1 PMI-IF-11-400H 400,000 360,000 5:1 PMI-IF-12-400H 400,000 360,000 10:1 PMI-IF-12-500H 500,000 450,000 10:1 PMI-IF-12-600H 600,000 540,000 10:1 PMI-IF-12-800H 800,000 720,000 10:1 PMI-IF-22-1000H 1,000,000 900,000 10:1 PMI-IF-22-1200H 1,200,000 1,080,000 10:1 PMI-IF-22-1400H 1,400,000 1,260,000 10:1 PMI-IF-22-1600H 1,600,000 1,440,000 10:1 Available High Efficiency Models The 90% furnace can be used in Price s custom rooftop unit platform, allowing almost any configuration of components and variable geometry. Single and dual path energy recovery is also available (see unit configuration). Up to four furnaces can be used in a 2 by 2 arrangement providing up to 1440 kbtu/h of capacity. priceindustries.com 2

Mechanical Unit Configuration The following components can be configured in almost any arrangement to meet your building requirements. 1 5 100% Outdoor Air Hood Mixing Box Scrolled FC and AF Fans DD and RD Plenum Fans Fan Arrays 6 Economizer (plan view) Economizer w/rf Fan (plan view) 2 90% Efficiency Furnace 7 2" Angular Fitlers Fixed Face & Bypass Cooling Coil 12" Cartridge Filters 3 Discharge Plenums 8 Full Cooling Coil (Water or integral DX) Fixed Face & Bypass Cooling Coil Hot Gas Reheat Top Mounted DX End Mounted DX 4 Access Section Humidifier Silencer 3 priceindustries.com

Condensate Management Condensate Chase Neutralizing Kit Applying the Price high efficiency furnace is no different than any other gas heat product except for condensate. As the high efficiency furnace extracts the heat, the water vapor in the combustion gas starts to condense. This also happens with other high efficiency gas heat products such as home furnaces and condensing boilers. If the equipment is roof mounted in a climate where freezing conditions may occur, the management of the condensate is critical. Price recommends a drain inside the building under the unit. The condensate can be routed down through the curb to the drain. If the application requires the condensate drain line to be exposed to freezing conditions, field-supplied heat tracing is required. Price offers an optional neutralizing kit to raise the PH of the condensate where local codes require it. The kits can be factory mounted in the unit or shipped loose for field installation. priceindustries.com 4

Mechanical Custom configurations 1 or 2 foam or fiberglass construction Galv, painted or SS Liners Washdown liners Engineered and structural Air and Water Cooled Integral DX Cooling 3 to 60 tons Standard and high efficiency Top or end mounted Filter Options Pre and final filters MERV 8 to 14 Cartridge filters Supply and Return Fans Direct and belt drive plenum fans Fan arrays 5 priceindustries.com

Controls Factory installed and tested controls BACnet compatible Other Options Energy recovery Humidification Silencers Chilled water cooling 90% Efficient Indirect Fired Furnace 150 to 1,600 kbtu/h input priceindustries.com 6

priceindustries.com UNITED STATES 2975 Shawnee Ridge Court Suwanee, Georgia USA 30024 PH: 770.623.8050 FAX: 770.623.6404 CANADA 638 Raleigh Street Winnipeg, Manitoba Canada R2K 3Z9 PH: 204.669.4220 FAX: 204.663.2715 Product Improvement is a continuing endeavour at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Not all products may be available in all geographic areas. All goods described in this brochure are warranted as described in the Limited Warranty shown at priceindustries.com. The complete Price product catalog can be viewed online at priceindustries.com. Price is a registered trademark of Price Industries Limited. 2015. Printed in Canada 2015 v300