A project to optimise quality and energy efficiency must include metering

Similar documents
Applications. diris_826_a_1_gb_cat

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Quick Connect. quick - simple - efficient.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

Power Meter Series 700

Static energy meters

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Energy Management Energy Meter Type EM23 DIN

EARTH LEAKAGE PROTECTION: CONTENTS

Application/Connection Examples

3-phase, bidirectional energy meter

Maximum Demand Control

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Energy Management Power Analyzer Type WM14-96 Basic Version

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

M2M The measure of efficiency

Technical note NT588 NT604 NT695 NT782

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Counter for Energy. We make energy measurable and secure your future.

Energy meters For an efficient control of energy consumption

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

3-Phase Energy meter with serial S-Bus interface

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Process Alarm Solutions

Voltage Regulator SPAU 341 C. Product Guide

Current transformers (CT) & Shunts

R.C.C.B. s two-pole LEXIC

SURGE PROTECTIVE DEVICES

Thyristor-controlled power supplies and battery chargers

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Measurement and Control CVM. Power analyzers. Energy efficiency technology

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Smile. The All-In-One Heating Controller

Electrical measurement and control M.5. CVM Power analyzers

Current and Energy. Measurement Technology

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Bulletin 150 SMC Flex Smart Motor Controller Specifications

T Substation Maintenance and Commissioning Test Equipment

TX2123 RS485 TO ETHERNET ADAPTOR

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

EM-PQ 1500 Power Quality Monitor. Operating Manual

PCS0100en Persy Control Services B.V. Netherlands

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Electrical Measuring Instruments

Eaton s E-Series protective relay family

Polyphase kwh Electricity Meter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Panorama Electricity meters For reliable values of energy consumption

Power management. PowerLogic System. Catalogue 2004

Kit Watt Audio Amplifier

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Multi-Function Ground

SYSTEM MONITORING Locally and remotely

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Managing. Energy management and power analysis

ENERGY AUDITING AND MONITORING IN COMPANIES

Preset Counter signo 721

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

One Meter Works for Both Energy Saving and Power Quality Surveillance

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Duct Humidity Transmitter

40.3. Control Relays and Timers

THERMAL ENERGY METER MC 108/ET

Low Voltage Products

Temperature & Humidity SMS Alert Controller

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Electronic Control Devices The European Product Catalogue 2007

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical Data. back-up time in minutes 100% load % load

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Panel Meters and Controllers Modular Panel Meter Type EDM 35

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ADM1TE 5/30A DIN rail single phase two wire energy meter

Installation and operating instructions

Digital multimeters DMG

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Electronic Control Devices The European Product Catalogue 2007

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Measurement and Instrumentation

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Transcription:

EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken, and downstream to monitor the effects and control any drift. Legrand EMDX³ metering range will naturally have a place in distribution boards. EMDX 3 metering control units All the essential parameters of the installation on DIN rail or on the door : - Active and reactive energy - Operating time - Power factor - Harmonic distortion - Programmable alarms 80 EMDX³ unit on DIN rail EMDX³ unit on door EMDX³ units on doors provide a large size display and their capacity can be increased with extension modules.

Eco-design a voluntary approach The Legrand group has been taking environmental problems into account since 00. This approach is based on international standards for the objective measurement of the environmental impacts of products in terms of both consumption of resources and pollution. Legrand publishes these reports in the form of PEP (Product Environmental Profile) sheets. Remote supervision and viewing With the Legrand communication interfaces (RS 485, IP), supervision software and Web servers, measurements can be centralised and displayed remotely on a PC, tablet or smartphone. EMDX 3 electricity meter on DIN rail EMDX³ meters installed in secondary distribution boards can be used to monitor consumption per building, per floor and per application. Display of 3 measurement points on tablet computers and WEB SERVERS Electrical energy meters, p. 8 8

EMDX 3 electrical energy meters 4 rail mounting NEW EMDX 3 multi-function metering units 4 rail mounting 0 046 70 046 74 0 046 76 Technical characteristics p. 85-87 Technical characteristics p. 85-87 Measure the electricity consumed by a single-phase or three-phase circuit downstream of the electricity distribution metering Display electricity consumption in kwh, as well as other values such as current, active energy, reactive energy and power (depending on the catalogue number) Conform to standards IEC 6053-/3, IEC 605- and IEC 600- MID compliance ensures accuracy of the metering with a view to recharging for the electricity used Pack Cat.No. Single-phase meters Non-MID MID Direct connection compliant 0 046 70 3 A - module 046 8 36 A - modules 046 7 0 046 78 63 A - modules 0 046 77 0 046 79 63 A - modules RS 485 output Three-phase meters Non-MID MID Direct connection compliant 046 73 0 046 8 63 A - 4 modules 0 046 80 0 046 83 63 A - 4 modules RS 485 output Connection with CT 046 74 0 046 85 5 A - 4 modules pulse output 0 046 84 0 046 86 5 A - 4 modules RS 485 and pulse output Conform to standards: - IEC 6557- - IEC 6053- class 0.5 S - IEC 6053-3 class Pack Cat.No. EMDX 3 modular For mounting on rail Width: 4 modules LCD display Measurement of currents, voltages, active, reactive and apparent power and internal temperature Dual tariff metering: - Active energy consumed - Reactive energy consumed - Operating time - Power factor THD voltages and currents up to order 5 Programmable alarms on all functions Outputs for controlling wiring devices, alarm feedback and pulse feedback EMDX 3 pulse unit 0 046 75 Data transmission via pulses EMDX 3 RS 485 unit 0 046 76 Data transmission via RS 485 communication interface and pulses Concentrator 0 046 87 For collecting and transmitting measurements taken by 7 universal pulse electricity meters Also collects data from other meters (gas meters, water meters, etc.) RS485 output 4 modules 8

EMDX 3 multi-function metering units for mounting on door or solid faceplate NEW 0 46 68 0 46 69 0 46 73 Current transformers (CT) p. 84 Technical characteristics p. 85-87 Conform to standards: - IEC 6557- - IEC 6053- class 0.5 S - IEC 6053-3 class Pack Cat.No. EMDX 3 - Access Multi-function metering unit 0 46 68 For mounting on door or solid faceplate Dimensions: 96 x 96 x 60 mm LCD display Measurement of currents, voltages, active, reactive and apparent power, internal temperature and power factor Metering: - Active energy consumed or produced - Reactive energy consumed or produced - Operating time - Pulses THD voltages and currents up to order 5 Programmable alarms on all functions Can take optional modules Modules for EMDX 3 - Access multi-function metering unit 0 46 7 RS485 communication module MODBUS link 0 46 7 -output module Can be assigned to pulse feedback, alarm feedback or control of wiring devices EMDX 3 - Premium Multi-function metering units 0 46 69 For mounting on door or solid faceplate Dimensions: 96 x 96 x 60 mm LCD display Measurement of currents, voltages, active, reactive and apparent power, internal temperature and power factor Metering: - Active energy consumed or produced - Reactive energy consumed or produced - Operating time - Pulses Individual harmonics up to order 63 Programmable alarms on all functions Can take 4 optional modules Modules for EMDX 3 - Premium multi-function metering units 0 46 73 RS 485 communication module MODBUS link 0 46 74 Storage module Storage of active and reactive power over 6 days, the last 0 alarms and the average voltage and frequency values over 60 days max. 0 46 75 Module with inputs/ outputs Up to 3 modules, i.e. 6 inputs/6 outputs, can be installed Outputs can be assigned to monitoring mode, remote control or timed remote control 0 46 77 Temperature module Indication of the internal temperature and possibility of connecting 3 sensors for measuring the external temperature Pack Cat.No. Communication and supervision Web servers Enable remote viewing, via a web browser on PCs, smartphones, web viewers, tablet computers such as ipads, Archos, etc., of values collected on electricity meters and multi-function metering units 0 6 78 For 3 metering points (meters or multi-function metering units) 0 6 79 For an unlimited number of metering points (meters or multi-function metering units) Legrand software dedicated to measurement For displaying the values collected from electricity meters or multi-function metering units on a PC connected to the network 0 6 88 For 3 metering points (supplied on CD) 0 6 89 For an unlimited number of metering points (supplied on CD) Legrand supervision software - made-to-measure 9 000 8 For customised display of the values collected and control of the power installation on a PC IP converter 0 046 88 For RS 485 / Ethernet conversion for connecting electricity meters and multi-function metering units to an IP network. Please consult Legrand for more information 83

current transformers CT current transformers CT n Current transformers (CT) Technical characteristics Degree of protection: IP 0 Operating frequency : 50/60 Hz 047 78 Dimensions Single-phase CTs Cat. No. 046 3/34/36 for 6 x.5 mm bar and Ø mm cable Fixing on EN 6075 rail 44 30 65 Pack Cat.No. Single-phase current transformers (CT) Used with ammeters, electricity meters or multi-function measuring units Provide a 0 to 5 A current at the secondary, proportional to the primary current For fixing on plates, EN 6075 4 rail Cat.No. 046 3/34/36, or bars Secondary connected by terminals or lugs Precision class % For 6 x.5 mm bar and Ø mm cable Transformation ratio Output (VA) 046 3 50/5.5 046 34 00/5.5 046 36 00/5 5.5 For 40.5 x 0.5 mm bar and Ø35 mm cable 046 38 400/5 For 65 x 3 mm bar 047 76 600/5 047 77 800/5 5 047 78 000/5 0 For 7 x 38 mm bar 046 45 500/5 5 046 46 000/5 0 For 7 x 54 mm bar 047 80 500/5 50 046 48 4000/5 50 47,5 Cat. No. 046 38 for 40.5 x 0.5 mm bar and Ø35 mm cable Fixing on EN 6075 rail or on plate D A B C 45 Cat. No. A B C D Ø Fixing centres on plate 046 38 77 46 07 54 35 54 x 45 Cat. No. 047 76/77/78 for 65 x 3 mm bar Fixing on bar D A B C Cat. No. A B C D 047 76/77/78 90 90 94 40 Cat. No. 046 45/46 for 7 x 38 mm bar Cat. No. 047 80 and 046 48 for 7 x 54 mm bar Fixing on bar B A 87 60 Cat. No. A B 046 45/46 99 58 046 48/047 80 5 40 Determination of the max. distance between CT and meter Cat. No. Max. power of CT Meter consump. (W) Max. loss in capac. (VA) Max. distance bet. CT & meter (m) Wiring.5 mm Wiring 4 mm Wiring 6 mm 046 3.5 0.5 0.75.8.7 3.9 046 34.5 0.5 4.9 7. 0.4 046 36 5.5 0.5 5. 7.8 5.9 046 38 047 76 047 77/79 046 45 046 46 047 78 047 80 046 48 0.5.5 8 40.8 59.6 5 0.5 4.5 35.3 5.5 75. 0 0.5 9.5 47.4 69.3 0. 50 0.5 49.5 0.4 75.8 56.7 84

EMDX 3 electrical energy meters 4 rail mounting n Technical characteristics Single-phase meters Cat. Nos 0 046 70/7/77/78/79/8 LCD display: 7 digits Resolution: 0. kwh Maximum indication: 99999.9 kwh Metrological LED: Wh/pulse (Cat.No. 0 046 70 : 0.5 Wh/pulse) Accuracy (EN 6053-): class Reference voltage Un: 30 V-40 V Reference frequency: 50-60 Hz : pulse/0 Wh (Cat.No. 0 046 70: pulse/wh) Three-phase meters Cat. Nos 0 046 73/74/80/8/83/84/85/86 LCD display: 8 digits Resolution: 0.0 kwh () Maximum indication: 99999.99 kwh () Metrological LED: 0. Wh/pulse or Wh/pulse Active energy accuracy (EN 6053-): class Reactive energy accuracy (EN 6053-3): class Reference voltage Un: - Single-phase: 30-40 V - Three-phase: 30(400)-40(45) V Operating limit range (EN 6053-, EN 6053-3): - Single-phase: 0 to 54 V - Three-phase: 0(90) to 54(440) V : pulse/0 Wh Cat. No. 0 046 70 046 8 046 7 0 046 77 0 046 78 0 046 79 046 73 0 046 80 0 046 8 0 046 83 046 74 0 046 84 0 046 85 0 046 86 Number of modules 4 4 4 4 4 4 4 4 Connection Direct Via a current transformer Single-phase Three-phase Max. current 3 A 36 A 63 A 63 A 63 A 63 A 63 A 63 A 63 A 63 A 5 A (CT) Metering Communication MID compliant Operating conditions Total active energy Total reactive energy Partial active energy (reset) Partial reactive energy (reset) Active power Reactive power Apparent power Current Voltage Frequency Power factor Time-of-use Average active power Max. average active power value Dual tariff RS 485 interface Reference temperature 3 C ± C Operating temperature -0 to +55 C -0 to +45 C -5 to +55 C Storage temperature -40 to +70 C -5 to +70 C -5 to +70 C Consumption 8 VA 4 VA per phase VA per phase Heat dissipation 6.5 W 6 W 4 W 5 A (CT) 5 A (CT) 5 A (CT) n Interfacing with IP communication network Pulse electricity meters RS 485 electricity meters Concentrator Cat. No 0 046 87 Connects up to 7 pulse electricity meters RS 485 - Fieldbus RS 485/IP converter Cat. No 0 046 88 IP network - Communication bus : For direct connection meters If connected via transformers, the resolution and maximum indication depend on the transformation ratios of these transformers 85

EMDX 3 multi-function metering units n Technical characteristics Cat.No. 0 046 75/76 0 46 68 0 46 69 Connection Protection index Current measurement terminals 4 mm 6 mm 6 mm Other terminals.5 mm.5 mm.5 mm Front cover IP 5 IP 5 IP 5 Casing IP 0 IP 30 IP 30 Weight 05/5 g 400 g 400 g Display Backlit LCD Backlit LCD Backlit LCD Measurements 3P+N, 3P, P, P+N 3P+N, 3P, P, P+N 3P+N, 3P, P, P+N Direct Phase/phase 50 to 50 VA 50 to 500 VA 8 to 700 VA Phase/neutral 8 to 300 VA 8 to 89 VA to 404 VA Voltage measurement From a PT Primary - - 500 kv Secondary - - 60, 00, 0, 5, 0, 73, 90 VA Permanent overload between phases 760 VA 800 VA 760 VA Update period s s s From a CT Primary 5 to 9999 A 9999 A 9995 A Secondary 5 A 5 A or 5 A Minimum measurement 5 ma 5 ma 0 ma Input consumption < 0.6 VA < 0.6 VA < 0.3 VA Current measurement Display 0 to 9999 A to ka 0 to ka Permanent overload 6 A 6 A 0 A Intermittent overload 60 A/ s - 0 A/0.5 s 0 In/ s 0 In/ s Update period s s s Max. CT x PT ratio - - 0000000 Power measurement Total 0 to 9999 kw/kvar/kva 0 to MW/Mvar/MVA 0 to 8000 MW/Mvar/MVA Update period s s s Frequency measurement Measurement range 45.0 to 65.0 Hz 45.0 to 65.0 Hz 45.0 to 65.0 Hz Update period s s s 50/60 Hz 00 to 77 VA ±5% 0 to 400 VA ±0% 0 to 400 VA ±0% Auxiliary power supply DC - 0 to 350 V= ±0% 0 to 350 V= ±0% Consumption < 5 VA < 0 VA < 0 VA Operating temperature -0 C to +55 C -0 C to +55 C -0 C to +55 C Storage temperature -0 C to +70 C -0 C to +85 C -0 C to +85 C n Flush-mounting dimensions Cat.No. 0 46 68/69 n Fixing on door Cat.No. 0 46 68/69 9 + 0,8-0,0 96 9 + 0,8-0,0 60 0 96 n Fitting modules Cat.No. 0 46 68/69 86

n Connection solutions Unbalanced three-phase network (3 or 4-wire) (3-wire) I I I3 S S S V V V3 VN AUX I I I3 S S S V V V3 VN AUX I I I3 S S S V V V3 VN AUX L (R) L (S) L3 (T) N L (R) L (S) L3 (T) L (R) L (S) L3 (T) Balanced three-phase network (3 or 4-wire) I I I3 S S S V V V3 VN AUX Single-phase network (-wire) I I I3 S S S V V V3 VN AUX Two-phase network (-wire) I I I3 S S S V V V3 VN AUX L (R) L (S) L (R) N L (R) L (S) L3 (T) N a Auxiliary power supply: 0 400 VAC/0 350 VDC b Fuse: 0.5 A gg/bs 88 A gg/0.5 A class CC n Interfacing with IP communication network Ethernet TCP/IP network Web server Cat.Nos 0 6 78/79 or PC with supervision software Cat.Nos 0 6 88/89 RS485/Ethernet converter Cat.No 0 046 88 Multi-function measuring unit Cat.No 0 46 69 RS485/Ethernet converter Cat.No 0 046 88 RS485 fieldbus Multi-function measuring unit Cat.No 0 46 68 with RS485 communication module Cat.No 0 46 7 RS485 fieldbus RS485 modular multi-function measuring unit Cat.No 0 046 76 RS485 modular multi-function measuring unit Cat.No 0 046 76 RS485 modular multi-function measuring unit Cat.No 0 046 76 Main LV distribution board Secondary board 87