Autoclave Design Considerations



Similar documents
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Originators of the Flexible Water Tube design

LARGE PROJECTS REQUIRE STRONG TEAMS

IVISIONS STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. INDUSTRIAL BOILER & MECHANICAL

heat treatment equipment & accessories

German engineering under high pressure

Boiler & Pressure Vessel Inspection discrepancies and failures

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioning Sign-Off Sheet

DIGITAL WARMING CABINETS

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Description of Thermal Oxidizers

Your Boiler Room: A Time Bomb?

ASME Packaged Indirect Fired Water Heater

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Backup Fuel Oil System Decommissioning & Restoration Plan

Commercial Gas Water Heaters

FVA/A1 saturated-steam sterilizer

Light Duty Commercial Electric Water Heater

RPV - RP - RA air handling units

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Cylinder HAZMAT & Fill Station Operations Compliance. PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham

Plan Number A Cross Beam Dr. Charlotte, NC Simplified Service Plan. Air Conditioning.

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

A World Class Manufacturer of Induction Bends

Free piston Stirling engine for rural development

BSL3 and BSL4 Autoclaves. Laboratory Line

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

I NI NP R Inspected Items

Commercial Gas Furnace Upflow

Restaurant & café guide

Ceiling Mount Air Handler Manual

Condensing Boiler Efficiency

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

FACT SHEET : Using Autoclaves Safely

WHAT IS INFRARED (IR) THERMOGRAPHY

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PTFE Slide Bearings 04/10 149

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Waterproofing and interior insulation for basements takes new twist in technology.


Packaged Terminal Air Conditioner Wall Sleeve Installation

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

Preventing Overheated Boiler Incidents

Simplified Service Plan

Medical Waste Autoclaves. Medical Waste Autoclaves

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Facilities Maintenance Standards rev

How to Conduct a Magnet Pull Test

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Steam Sterilization Cycles for Lab Applications

PROPERTY INSPECTION REPORT

Select Radiators Installation Guide

Influence of Belt Furnace on Glass-to-Metal Seal Process

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

HVAC Claims: Repair vs. Replacement

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Oil and Gas Pipeline Design, Maintenance and Repair

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

10 tips for getting more reliability from your air-conditioning system [reliability]

Copyright 1999 Inter-Industry Conference On Auto Collision Repair v.4.0

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

HVAC Repair and Maintenance Strategies by Ron Prager

Vision Home Inspection

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

CENTRIFUGAL DRYERS JUNE 2013 GALA INDUSTRIES, INC.

Boiler and Burner Cleaning and Servicing Specifications

Determining the Right Molding Process for Part Design

Gas Oven Repair Guide

Termite Inspection Protocol

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Basics of HVAC Cleaning

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Redefining Spray Technology

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

UDSA - UDSBD unit heater

Process Safety Management of Highly Hazardous & Explosive Chemicals. Management of Change

Acumen Enterprises, Inc.

Freezers - Ultrafreezers. Platilab & Irilab Series

North Carolina State University Emergency Facilities Closure Checklist- Part I

Using Portable Spot Air Conditioners in Industrial Applications

Nondestructive Testing: Why, When, What and How?

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Flange Insulation Sets

1A PLANNING AND DEVELOPMENT SHERIDAN COLLEGE GOES DANISH IMPLEMENTING THEIR DISTRICT ENERGY

Chapter 7 Hydraulic System Troubleshooting

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Intermodal Containers Presented by Bill Hand Training Coordinator Hazardous Materials Response Team Harris County, Texas

Standard Pneumatic Test Procedure Requirements for Piping Systems

Nominal Life Expectancy for Building Components

SL280UHV SERIES GAS FURNACE WARNING

Transcription:

Autoclave Design Considerations Most composite manufacturing personnel are familiar with autoclave processing and understand basic autoclave operating principles. The autoclave is considered the most robust of all composite processing options. It is tolerant of both mistakes by lay-up technicians and material problems. The extra compaction pressure available with an autoclave minimizes porosity and bridging and maximizes resin flow. Any shop can get great composite parts with an autoclave! Since an autoclave represents a fairly sizable investment and costs a lot to operate, this article will address autoclave design considerations. Autoclaves are used in a variety of industries. Medical device and waste sterilization, automotive and architectural glass lamination, rubber processing and wood treatments are just a few industries that utilize autoclave processing. Because of this, there are often a fair amount of used autoclaves on the market. These can represent a good deal to a prospective purchaser, if you know what to look for.

Pressure Vessel Industrial pressure vessels are required to be manufactured to ASME code and should be inspected in accordance with various national board standards. This information, as well as the working pressure and temperature and original manufacturer should be listed on a data plate affixed permanently to the autoclave. Corrosion, stress and fatigue can weaken an autoclave over time. Used equipment should always be inspected for condition prior to being placed back in service. It is not unusual for vessel walls to be corroded to less than half their original wall thickness. Door hinges and locking mechanisms can suffer from wear and misalignment. Many were poorly designed and built to begin with. Welds can crack. Consider that 60 PSI behind a 6 door is generating an opening force of over 100 tons. When purchasing new equipment, always specify inner working dimensions in length and diameter. Be aware that the fan, heat exchangers, plenums and insulation will take up significant internal volume. Speaking of insulation, if a pressure vessel is insulated externally, you will be heating and cooling the entire steel mass of the pressure vessel every time you run a load of parts. This is not only inefficient, but very hard on the structure and mechanical systems. We recommend a minimum of 4 internal rock wool insulation. Pressurization Autoclaves can be pressurized with air or nitrogen, depending on customer requirements. Industry standard seems to be that air is OK up to temperatures of around 250 F. above 250 F, nitrogen is usually used to assist heat transfer and mitigate the potential for fire. Fires are not common, but they can cause a lot of damage to the autoclave itself. Losses could

include a full load of parts and production down time while repairs are made. Fires can be caused by localized frictional heating from a bag leak and resin system exotherm. At higher pressures, more oxygen is available to feed the fire. Since the entire interior of the pressure vessel must be removed to inspect and repair an autoclave after a fire, nitrogen charging should be considered. Heat Transfer Energy costs are rising and along with them, the cost of heating and cooling your autoclave. Heat transfer is a very large percentage of both the purchasing and operating cost of any type of composite processing equipment. For heating, the customer needs to choose between electric and gas. In the Southeastern United States, shops are often located very close to inexpensive sources of hydroelectric power. Anyone else is pretty much committed to natural gas for their process heating requirements. Fan size and heat exchanger design have a huge effect on your heating bill. Fan motors should be mounted internally, oversized and heat exchangers should be manufactured from 321H stainless steel. Specify it. This costs more up front, but will result in very long (10-15 year) heat exchanger service life. Cheaper heat exchanger constructions require repair every 3 to 5 years. This means complete disassembly and removal of the vessel interior, resulting in higher maintenance costs and more equipment down-time. High efficiency burners will not only lower your energy bills, but reduce Nox emissions. Along with a larger capacity fan, design of the plenums within the pressure vessel affect energy use and the rate at which an autoclave can heat and cool and load of parts. All things being equal, an annulus type plenum design is much more efficient than under floor heat exchangers and ducting. It will quickly pay for itself in the first year of operation and generate significant savings every year thereafter.

Controls A non-aerospace shop batch processing laminated glass or automotive parts can get away with a simplified control system. These folks might utilize a single vessel mounted thermocouple and run a single vacuum line to each part. As long as the parts can pass a visual inspection and look good, everyone is happy. We still recommend proportional vessel pressurization control valves, even for simple autoclaves. Operation is much smoother and the pressurization system components last much longer. More complex parts and tighter quality requirements call for more sophisticated controls. Multiple thermocouple channels and dual vacuum circuits per part have become pretty much standard in the aerospace industry. The autoclave itself should be run by a high quality PLC. We prefer Allen Bradley. They cost a little more, but reliability and support are very good. Control software should be open source with graphing and data logging capability. That is to say that you should own any software you purchase and have the right to make changes or modify its function to fit your application. Any responsible autoclave manufacturer will be more than happy to help you customize your software, teach you how to use and support it. Shops doing aerospace MRO type work often request a heat blanket control interface. That way, they can direct localized heating only into the bond repair and utilize the autoclave for pressure. A tremendous advantage of the autoclave is its flexibility and any control system should be carefully designed to take advantage of this.

Safety Any new or used autoclave considered for purchase should have all safety features and devices specified by applicable code. The door locking mechanism should be fail safe, meaning that you cannot pressurize the autoclave unless it is securely locked. Toggle bolt style door locking mechanisms are fine for lab autoclaves 18 in diameter or smaller. They are to be avoided for any autoclave used in a production environment. There is just too much chance of a worker improperly tightening the bolts and no real way to make them fail safe. Remember Murphy s Law. If a mistake can be made, someone will eventually make it. Door or pressure vessel failures are potentially catastrophic, with serious injury or death a very real possibility. Every autoclave should receive a full safety inspection every year, with written results retained in your plant safety records. Most industrial insurance coverage now requires this. Conclusion Composite manufacturer s have a lot of process options available. VARTM, RTM, press and oven are only a few that come to mind. An autoclave offers manufacturing flexibility and a truly robust process. When you need perfect parts, nothing beats delta P. Steve Zeller is a manufacturer s representative with over 25 years experience in composite manufacturing tooling, process equipment and materials. His company, www.southbrooktech.com represents www.autoclaves.com in the southeastern United States.