ROOF DRAINS TABLE OF CONTENTS



Similar documents
FLOOR AND AREA DRAINS

SECTION STORM DRAINAGE SYSTEM

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

CHAPTER 11 STORM DRAINAGE

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

roline Commercial Drainage Products Catalog & Price List Effective April 2, 2012 watts.com

CLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS

Fabricated Drainage Products

SECTION GROUND WATER STORAGE TANKS

SECTION SOIL AND WASTE SYSTEMS

INDEX. Sec. No. Items Page Nos.

ROOF DRAINS ROOF DRAINS. LEVELEZE Features. Conventional Features

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

GRATES AND DRAINS HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

CI/SfB. February Roof Outlets

CHAPTER 11 STORM DRAINAGE

SECTION PIPE HANGERS AND SUPPORTS

CHAPTER 11 STORM DRAINAGE

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

INSTALLATION OF A BAY WINDOW

Ver. 2. Guide to. Inspecting Residential Brick Veneer

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

MIFAB Floor Drain Selection Guide

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Welcome: What is U Drain? Drain Materials. Flow

frostdrainage.com Floor Drains & Rodding Eyes

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

ROOF DRAINS. 72(a) ROOF DRAINS MPB-2011-USA

FLOOR DRAINS FLOOR DRAINS. SUPER-FLO Features

WATER SERVICE 2

American- Darling 5¼" B-84-B-5.

Jay R. Smith Mfg. Co.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

PERIMETER FLASHING. Table of Contents

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Syphonic Roof Drainage

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

CODE GUIDE 302 and Glossary of Industry Terms

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

SECTION FACILITY STORM DRAINAGE PIPING

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SANITARY SEWER SPECIFICATIONS

PRESSURE REDUCING CONTROL VALVE

Syphonic Roof Drainage

MAST ARMS & POLES. Ornamental Pole Top & Bases

Soakage Trenches. A better way to manage stormwater. Thinking Globally and Acting Locally

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

倀 䰀 唀 䴀 䈀 䤀 一 䜀 刀 䄀 䤀 一 圀 䄀 吀 䔀 刀 匀 夀 匀 吀 䔀 䴀 匀

8.7 Schluter -KERDI-LINE

Fiberstars Mini Lighted Laminar Flow Fountains

2006 Codes. Please verify the following before calling for inspection

During severe flood events, such as those

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

SECTION STORM DRAINAGE TABLE OF CONTENTS

Town House Center Highway North Huntingdon, PA 15642

SECTION DUCTILE IRON PIPE AND FITTINGS

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

WINDOW INSTALLATION GUIDE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

SECTION STORM DRAIN SYSTEM

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Residential Decks. Planning and Development Services Department

SECTION DUCTILE IRON PIPE AND FITTINGS

Superform Products Ltd.

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

3. Geberit Pluvia Roof Drainage Systems

Roof Curbs, Extensions and Equipment Supports

SECTION WINDOW WASHING SYSTEMS

A. This Section includes the following for soil, waste, and vent piping inside the building:

SECTION UNDERGROUND ELECTRIC SERVICE

ACO Water Management: Civils + Infrastructure

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Drum Dispensing Stations

Constructing Cistern Installations

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Drainage Products Catalog. March 2011

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Preformed Metal Roofing and Siding

Storm Drainage Structures

NEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp

PArt# spout Length Adjusts /2 to 8-1/ /2 to 8-1/ /2 to 8-1/ /2 to 8-1/2. PArt# FIts Adjusts

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

James M. Pleasants Company

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Transcription:

Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF DRAINS Distributed by: BEST MATERIALS LLC Phoenix AZ Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 Email: sales@bestmaterials.com www.bestmaterials.com S-WD-RD-1 0812

PICTORIAL INDEX RD-100 Large Area RD-100-SO Side Outlet RD-200-R External Overflow RD-240 Bottom Outlet Balcony RD-100-CP 12" Promenade Top RD-100-W Internal Overflow RD-200-SO Side Outlet RD-250 Overflow Combination RD-100-F Reversible Extension Flange RD-200 Small Area RD-200-W Internal Overflow RD-260 Overflow Combination RD-100-R External Overflow RD-200-CP Promenade Top RD-230 Side Outlet Balcony RD-270 Scupper w/angle Grate S-WD-RD-2 0812

PICTORIAL INDEX RD-280 General Purpose RD-300-CP15 15"x15" Promenade Top RD-400 Deck Receptor RD-900 Expansion Coupling RD-280-SO Side Outlet RD-300-F Reversible Extension Flange RD-410 Deck Receptor RD-940 Downspout Nozzle RD-290 Scupper w/flat Grate RD-300-R External Overflow RD-500 Super Max 12" Roof Drain RD-950 Downspout Cover RD-300 High Volume RD-300-W Internal Overflow RD-680-VC Vent Cap RD-970/RD-980 Downspout Boots S-WD-RD-3 0812

PRODUCT RECOMMENDATIONS Application Balcony or Canopy Deck Receptor Downspout Nozzle / Cover Downspout Boot Primary Roof Area Primary Roof Overflow Promenade or Patio Scupper or Parapet Secondary Roof Area Secondary Roof Overflow Product RD-230, RD-240 RD-400, RD-410 RD-940, RD-950 RD-970, RD-980 RD-300, RD-300-F RD-300-R, RD-300-W RD-100-CP, RD-200-CP, RD-300-CP15 RD-270, RD-290 RD-100, RD-100-F, RD-200, RD-200-F RD-100-R, RD-100-W, RD-200-R, RD-200-W ROOF DRAIN SELECTION FACTORS Sizing 1. Calculate roof area (sq. ft.) to be drained. 2. Determine average hourly rainfall rate at roof location (Chart A). 3. Approximate leader (drain pipe) size. In general, increasing leader size will decrease the number of drains required. 4. Reference leader size with hourly rainfall rate, to determine roof area drained by each leader (Chart B). 5. Divide roof area (1.) by area per leader (4.) to determine the number of drains required. 2" 2" 1-1/2" 6" 5" 5" 6" 2" 1-1/2" 5" 7" Chart A 5" 6" 7" 8" 8" 8" 8" 7" 9" S-WD-RD-4 0812

ROOF DRAIN SELECTION FACTORS cont. ROOF DRAINS Rainfall Rate (inches/hour) Placement For most efficient drainage, roof drains, to the extent possible, should be equally spaced. A roof drain must also be located in any potential water collection area. Material & Characteristics Bodies - Industrial grade cast iron, finished with Watts standard gray acid resistant epoxy coating. Many Watts roof drains can be specified with PVC (-60) or ABS (-61) bodies, for direct solvent weld connection. Combination Flashing Clamp/Gravel Guard - Standard acid resistant coated cast iron. Watts securing stud design helps spot flashing clamp bolt holes, which might otherwise be covered or filled during membrane application. Poly Dome - UV stabilized high density polyethylene, high resistance to breakage and weathering. Pipe Connection 2 Vertical Leader Sizing in Inches 3 4 5 Roof Area In Square Footage 1 2,880 8,800 18,400 34,600 54,000 116,000 2 1,440 4,400 9,200 17,300 27,000 58,000 3 960 2,930 6,130 11,530 17,995 38,660 4 720 2,200 4,600 8,650 13,500 29,000 5 575 1,760 3,680 6,920 10,800 23,200 6 480 1,470 3,070 5,765 9,000 19,315 7 410 1,260 2,630 4,945 7,715 16,570 8 360 1,100 2,300 4,325 6,750 14,500 Maximum tributary areas which can be drained by Roof Drains, Vertical Rainwater Leaders, or Storm-Water Conductors for Various Rainfall Rates. Source: ASPE Practical Plumbing Engineering (c) 1998 No Hub (Standard) - Butt connection using no hub or neoprene coupling, suitable for cast iron, plastic, and most other piping applications. Push-On (P) - Gasket connection ASTM C-564, with pipe stop. Suitable for no hub or service weight cast iron, Sch. 40 plastic, and steel pipe. Recommended for below grade use only. Threaded (T) - Female IPS thread in drain outlet. Inside Caulk (X) - Caulk ring on drain outlet, pipe is inserted and joint sealed with lead & oakum. PVC Socket (-60) - Sch. 40 PVC solvent weld female socket. ABS Socket (-61) - Sch. 40 ABS solvent weld female socket. Side Outlet (-SO) - No Hub (see above) side outlet. 6 8 Chart B S-WD-RD-5 0812

Commonly Specified Options ROOF DRAIN SELECTION FACTORS cont. Galvanized Body & Flashing Clamp (-13) - Cold zinc galvanizing, commonly specified in highly corrosive environments, such as coastal or industrial areas. Watts standard acid resistant epoxy coating eliminates the need for galvanizing in many applications. Accutrol Flow Restrictor (-A) - Regulates flow during heavy rains, reducing load on storm sewer system. Available 1 to 3 weirs, max. flow 30GPM per weir. Specification detail upon request. Sump Receiver (-B) - Drops roof drain flange flush with top of roof deck, eliminating strain on roofing membrane, and potential puddling around drain. Underdeck Clamp (-D) - Securely fastens drain to roof deck. Adjustable Extension (-E) - Raises roof drain from main deck, drain body and membrane clamp adjust level with top of insulation. Reversible Extension Flange (-F) - Heavy gauge zinc plated steel, creates stable surface over deck opening for quick installation and adjustment of drain body to height of insulation. Replaces specification for cumbersome sump receiver/extension combination. Stainless Steel Ballast Guard (-GSS) - 8" high perforated stainless steel, specified for high ballast, or in IRMA installations. Ductile Iron Dome (-K) - Epoxy coated, durable and impact resistant. Galvanized Ductile Iron Dome (-K13) - Cold zinc galvanizing, commonly specified in highly corrosive environments, such as coastal or industrial areas. Watts standard acid resistant epoxy coating eliminates the need for galvanizing in many applications. Ductile Iron Low Dome (-K) - Low profile, epoxy coated, durable and impact resistant. Aluminum Dome (-K80) - Epoxy coated, corrosion resistant. SS Mesh Covered Aluminum Dome (-K83) - Screen prevents small debris from entering drain. Vandal Proof (-6) - Allen head screws regularly furnished, torx & pin may be specified for high security applications. 2" High External Water Dam (-R) - Fixed water dam specified for primary overflow roof drains. Adjustable Internal Water Dam (-W) - Specified for primary overflow, standard dia. X high standpipe. S-WD-RD-6 0812

TYPICAL INSTALLATIONS WATERPROOFING WATERPROOFING INSULATION SUMP RECEIVER METAL DECK UNDERDECK CLAMP CAST IRON NO HUB DRAIN BODY RD-100-B-D DOME FLASHING CLAMP FLASHING CLAMP B15 BODY B15 BODY 2" INSULATION 2" INSULATION ADJUSTABLE EXTENSION FLANGE FLANGE RD-300-D-F METAL DECK UNDERDECK CLAMP ABS INTERNAL STANDPIPE WATERPROOFING CONCRETE UNDERDECK CLAMP RD-100-D-W NO HUB CAST IRON DRAIN BODY S-WD-RD-7 0812

TYPICAL INSTALLATIONS NICKEL BRONZE HEEL-PROOF GRATE PROM DECK GROUT WATERPROOFING CONCRETE RD-300-CP-15 PIPE SIZE NO HUB CAST IRON DRAIN BODY UNDERDECK CLAMP PARAPET WALL WALL FLASHING FLASHING CONCRETE RD-270 Distributed by: BEST MATERIALS LLC Phoenix AZ Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 Email: sales@bestmaterials.com www.bestmaterials.com S-WD-RD-8 0812