Alfa Laval Abatigo. Redefining adiabatic cooling



Similar documents
Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

Top performance now and in the future. Alfa Laval Performance Agreements

Get more from your GPHE. Complete Alfa Laval service offering for gasketed plate heat exchangers

360 Service Portfolio. The complete service offering from Alfa Laval

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Exclusive Stock for total peace of mind. Your private reserve of original spare parts

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Sanitary Heat Exchangers. The Complete Line

Alfa Laval PureBallast 3.1

Cool air. Air heat-exchanger solutions from Alfa Laval.

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

Controlling hygienic tank cleaning

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

White Paper: Free Cooling and the Efficiency of your Data Centre

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

Technical Systems. Helen Bedford

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Redefining Spray Technology

How To Get A Passive House

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Analysis of data centre cooling energy efficiency

Air-cooled Chillers with High Speed Centrifugal Compressors

Absolute and relative humidity Precise and comfort air-conditioning

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Defining Quality. Building Comfort. Precision. Air Conditioning

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Wet Bulb Temperature and Its Impact on Building Performance

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

System solution for data centres

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

White Paper #10. Energy Efficiency in Computer Data Centers

Healthcare Solutions. Hygiene, comfort and productivity for your healing environment

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

STULZ Water-Side Economizer Solutions

Scalable. Affordable. Flexible. Fast.

STULZ View On DataCenter Cooling

Save Up to on Your A/C Bills

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

PRODUCT DIRECT EVAPORATIVE COOLING PAD DATA SHEET

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

IV. Rear Mount System

Screw Compressors ESM Fixed Speed & VS Variable Speed

Heat Recovery from Compressed Air Systems. kaeser.com

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Building Energy Systems. - HVAC: Heating, Distribution -

HVAC Checklist - Long Form

OASIS PRODUCT GUIDE. Data Centre Cooling INDIRECT EVAPORATIVE COOLER. Data Centres. Telecoms. EPX technology. Class leading performance

Are these noise cancelling devices needed to make your chiller quiet??

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

ASTACEA4 Inspect complex/central air conditioning systems

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

Improving Data Center Energy Efficiency Through Environmental Optimization

State of the Art Energy Efficient Data Centre Air Conditioning

The Different Types of Air Conditioning Equipment for IT Environments

Free Cooling for Data Centers

CRITICAL COOLING FOR DATA CENTERS

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

Small-Scale Solar Heating and Cooling Systems

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Moving beyond colour. Alfa Laval bleaching processes for fats and oils

HVAC Systems: Overview

Tim Facius Baltimore Aircoil

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

Why and How we Use Capacity Control

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Guide to Minimizing Compressor-based Cooling in Data Centers

Elements of Energy Efficiency in Data Centre Cooling Architecture

Modular Chiller Plants for data centers. Downtime isn t acceptable

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Defining Quality. Building Comfort. Heating and Cooling Coils

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Evaporative Cooling for Residential and Light-Commercial

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Data Center RD&D at EPRI

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

Economizer Modes of Data Center Cooling Systems

GREEN DATA CENTER DESIGN

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

The Mean Green Cooling MachineTM

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Attachment J-C18.1. HVAC Work Instructions

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Transcription:

Alfa Laval Abatigo Redefining adiabatic cooling

Experience and expertise recognized throughout the world With decades of broad experience and practical expertise in heat transfer, Alfa Laval is today a world-leading supplier of heat exchangers. Innovation, performance, and sustainability are at the core of every product that we develop. With the Alfa Laval Abatigo, we continue setting a new standard for the cooling industry. Adiabatic coolers are designed for customers who are considering using cooling towers, but have concerns regarding the environment and performance, such as Legionella contamination or high costs. Worldwide support for total peace of mind To keep your equipment in top working condition, Alfa Laval offers a comprehensive portfolio of services including monitoring, smooth and safe start-up, and maintenance services. Our global sales channels and service engineers ensure that you get timely and reliable support where and when you need it. Alfa Laval near you - 103 sales offices in 53 countries - Worldwide support from product and application specialists - Original spare parts available from Alfa Laval channel partners

The next generation in efficient cooling Experience a new level of efficiency, delivered with greater performance, sustainability and adaptability. Alfa Laval pushes the boundaries of innovation to bring in the future s alternative in cooling with adiabatic technology. Introducing Alfa Laval Abatigo, a closed-chamber adiabatic cooler optimized for different applications to deliver long-term savings in water, energy, chemicals and maintenance time. Optimal cooling efficiency for different applications Alfa Laval Abatigo utilizes a unique method of cooling by spraying a fine mist of water to cool the air before it enters the heat exchanger coil. This state-of-the-art closed-loop cooling system has a moisture-absorbent cellulose honeycomb interior. It significantly reduces water consumption and energy use, and is highly adaptable to different applications and climates.

Sustainability Performance Adaptability The adiabatic chamber is activated with higher ambient temperatures to pre-cool incoming air. The closed-loop system with moisture absorption interior ensures that there is no evaporation of process water, keeping water clean and equipment scale-free while: Reducing water consumption by up to 95% vs. cooling tower. No water treatment required for adiabatic system. No need for anti-freezing treatment. No waterborne diseases thanks to absence of drift. The Alfa Laval Abatigo ensures that clean process liquid is supplied at the right temperature according to ambient climate conditions all year round, ensuring minimal monitoring and maintenance. Incorporating EC fans and other unique features into a quiet-operating design, Alfa Laval Abatigo delivers: Lower energy consumption by up to 95% vs. air-cooled central chiller. Higher cooling efficiency with optional fan exhaust diffusers. Perfect water temperature through precise controls that continuously adjust fans and adiabatic chamber activation as needed. Maximized uptime thanks to scalefree operation, durable construction, and safer acrylic-coated heat exchanger. The Alfa Laval Abatigo is easily optimized for different locations and applications. Its unique features help maintain precise cooling temperature and maximize uptime, regardless of climate, system demands or space constraints: Optimized for any climate with configurable options and set-up. Maximum capacity, low footprint compared to dry coolers. Air flow optimized in tight spaces with extended support legs.

Optimized for minimal lifetime costs Available with 1 20 EC fans per unit in single or double row configurations and capacities of 30 2100 kw (8 600 tons), depending on location, ΔT and supply temperature. Standard EC fans operate with close temperature control and energy consumption based on actual load conditions. Available fans with exhaust diffusers for increased energy efficiency and reduced noise levels. Adiabatic technology with zero moisture leakage Alfa Laval Abatigo prevents any water drift to the heat exchangers, keeping them completely dry preventing scaling, corrosion, and dangerous waterborne diseases such as Legionella. The cooler is designed to usually work in dry mode, when the adiabatic mode is activated, it works as follows: 1 2 3 4 5 High-temperature ambient air passes through lower adiabatic chamber. Inside this chamber, nozzles spray the coil with a fine mist of water from a separate source. The air is cooled due to humidification, prior to contact with heat exchangers. The chamber s design prevents any water drift outside the chamber when the cooled air travels to the heat exchanger. Digital control system continuously adjusts the amount of water sprayed to ensure consistent cooling.

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance of their processes. Time and time again. We help our customers to heat, cool, separate and transport products such as oil, water, chemicals, beverages, foodstuff, starch and pharmaceuticals. Our worldwide organization works closely with customers in almost 100 countries to help them stay ahead. How to contact Alfa Laval Up-to-date Alfa Laval contact details for all countries are always available on our website at www.alfalaval.com Scan the code to learn more about the Alfa Laval Abatigo. ECF00499EN 1503