How To Properly Maintain A Fiber Optic Infrastructure



Similar documents
Fibre optic testing best practices

Obsolete Fiber Technology? Not in my Data Center!

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

The Need for Low-Loss Multifiber Connectivity

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Overcoming OM3 Performance Challenges

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Upgrading Path to High Speed Fiber Optic Networks

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

How To Make A Data Center More Efficient

Optimizing Infrastructure Support For Storage Area Networks

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Data Center Design for 40/100G

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

A Guide to Patch Cord Management

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Polymer Coated Fiber Cable (PCF)

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

CISCO 10GBASE X2 MODULES

HUBER+SUHNER AG Phil Ward

40/100 Gigabit Ethernet: The Foundation of Virtualized Data Center and Campus Networks

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Data Center Topology Guide

Corning Cable Systems Optical Cabling Solutions for Brocade

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Loss & Continuity Testing with MPO/ MTP Connectors

MPO. Fast Fibre Solution for Data Centres

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

TIA Releases Guidelines for Maintaining Polarity Using Array Connectors

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

How To Make A Fibre Cable For A Data Centre

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Zone Distribution in the Data Center

Understanding Fiber Polarity: Implications at 10G, 40G, & 100G

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Structured Connectivity Solutions Field Testing Guidelines for Fiber-Optic Cabling Systems

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

InstaPATCH ZERO Solution Guide

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

HoW confident are You about Your connector cleanliness?

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Infrastructure for the next three generations

Corning Cable Systems Optical Cabling Solutions for Brocade

The ABC of Direct Attach Cables

Testing and troubleshooting enterprise fiber-optic cabling. Presenter: Neftali Usabal Fluke Networks - LATAM

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Living Infrastructure Solution Guide.

How To Create An Intelligent Infrastructure Solution

Inspection and Cleaning Procedures for Fiber Optic Connections

BICSI NxtGEN & Global Data Center Standards Update

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

Fiber in the Data Center

Category 8 Cabling Standards Update

Ethernet 102: The Physical Layer of Ethernet

MIGRATING TO A 40 GBPS DATA CENTER

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Choosing a Small Form Factor Connector Advantages of the LC Connector over the MT-RJ

CommScope Intelligent Building Infrastructure Solutions (IBIS)

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Enabling 21 st Century Connectivity

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

InstaPATCH Cu Cabling Solutions for Data Centers

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

SYSTIMAX Solutions. Intelligent Infrastructure (ipatch) Solutions Guide

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems

A Comparison of Total Costs of Ownership of 10 Gigabit Network Deployments in the Data Center

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

Pretium EDGE HD Solutions

Patch Cords for Data Center Applications

HIGH QUALITY FOR DATA CENTRES ACCESSORIES AND INFRASTRUCTURE. PRODUCT CATALOG 12/2014 PRO-ZETA a.s.

Gigabit Passive Optical Networks

Planning, Designing and Installing a Pre-Terminated Copper and Optical Cabling System for the Data Center

AMP NETCONNECT Data Center Cabling Solutions

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Field Testing Multimode 10 Gb/s (and beyond) Fiber Permanent Links

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

10GBASE T for Broad 10_Gigabit Adoption in the Data Center

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

4RU High Density Shelf Installation Instructions

The 8-Fiber Solution for Today s Data Center

Data Center Architecture with Panduit, Intel, and Cisco

Data Center Cabling Design Trends

CommScope Multi-Tenant Data Center Solutions: A solid advantage from the critical infrastructure experts. Data Center Solutions

Modern Data Center needs 10 th of April, Andrew Sedman, RCDD Head of Training and Technical Service R&M

Transcription:

How To Properly Maintain A Fiber Optic Infrastructure Best Practices to Minimize Damage and Failures in Fiber Optic Infrastructures White Paper Rodney Casteel, RCDD, NTS, OSP, Technical Manager, CommScope April 5, 2012 www.commscope.com

In today s IT environment, many elements like high speed internet, streaming video, social networking, mobile devices, government regulations, virtualization, network based security, building automation and collaboration are all driving an explosion in information content that needs to be processed and stored. This ever increasing acceleration in information being generated, processed and stored is at the highest point in history. This trend is shifting the dynamics of how networks are being designed and implemented. One of the major shifts, especially in the data center space, is the ever increasing migration to fiber optic infrastructure to accommodate the thirst for higher bandwidths, densities and application support. For years, fiber optic media has been utilized in the IT space, however, its presence and role within the data center space is rapidly changing. Traditionally, fiber optic ports were used primarily in the core areas of the data center to handle the aggregation of multiple copper uplinks. However, in today s data center environment fiber ports are now used all the way out to the server level and are replacing those longer copper uplinks. This new dynamic is vastly increasing the number of fiber ports and thus fiber links being deployed in the data center space today. In addition to the increasing number of fiber ports, there is also a fast growing trend of utilizing preterminated fiber solutions in the data center space. With this changing landscape within the infrastructure comes a need for better focus and education on the proper way to maintain these fiber optic links. While there has always been a need to ensure that optical fiber ports are clean and free from contamination, the reality is that up until now there has really never been any true industry standard or guidance on how best to do this and so everyone just adopted their own processes and procedures. In many cases, those processes and procedures were either lacking in best practices or ignored all together. So, why now is it more urgent to address this issue? We now have International Electrotechnical Commission standard IEC 61300-3-35 that emphasizes proper cleaning and outlines acceptance criteria for inspection and testing of optical fiber components. This standard is also referenced in TIA-568-C.0-2, which was approved in February, 2012. TIA-526-14-B, TIA-526-7 and TIA-568-C.0 standards all give recommendations on proper cleaning, inspection and testing of optical components and systems. For example, according to TIA-568-C.0 Annex E.4: Several precautions should be taken when measuring the performance of optical fiber cabling. Some of these precautions include: Ensuring that all connectors, mating adapters, and test jumpers or launch fibers are clean prior to and during the test measurement. Ensuring that all test jumpers are verified per clause E.5.1.2. Using test jumpers that are of acceptable quality as they are subject to heavy use. Replace test jumpers when no longer meeting the criteria established in clause E.5.1.2. Keeping endface inspection equipment nearby to help ascertain connector quality. To further understand why there is an urgent need for better education and focus on the installation and maintenance of these fiber optic systems we simply need to look at the limitations of the applications these links are being designed to support. All optical applications have an associated link loss budget, which is derived from the overall power budget for those specific applications. When we look at how those link loss budgets have evolved over time, it becomes very apparent that the trend in loss budgets is on a consistantly downward slope. See tables 1 and 2 for reference. www.commscope.com 2

Table 1 Application 62.5um (OM1) 50um (OM2) 50um (OM3/OM4) Ethernet 10BASE-FL (850 nm) 12.5dB @ 2000m 7.8dB @ 2000m 7.8dB @ 1600m 100BASE-FX (1300 nm) 11.0dB @ 2000m 6.0dB @ 2000m 6.0dB @ 2000m 10/100BASE-SX (850 nm) 4.0dB @ 300m 4.0dB @ 300m 4.0dB @ 300m 1000BASE-SX (850 nm) 2.6dB @ 275m 3.6dB @ 550m 4.5dB @ 800m 10GBASE-SR (850 nm) 2.4dB @ 33m 2.3dB @ 82m 2.6dB @ 300m 40GBASE-SR4 (850 nm) and 100GBASE-SR10 (850 nm) Not Supported Not Supported 1.9dB @ 100m OM3 1.5dB @ 150m OM4 Table 2 Application Fibre Channel 50um (OM3) 50um (OM4) 1GFC 4.6dB @ 860m 4.6dB @ 860m 2GFC 3.3dB @ 500m 3.3dB @ 500m 4GFC 2.9dB @ 380m 3.0dB @ 400m 8GFC 2.0dB @ 150m 2.2dB @ 190m 16GFC 1.9dB @ 100m 2.0dB @ 125m So, as can been seen from the above tables, when migrating from a 10BASE-FL application all the way to the 10GBASE-S application on 62.5um the decrease in link loss budget is 10.1dB. On the newer OM3/OM4 fibers the decrease is at least 5.2dB. When migrating to the newest 40/100GBASE-SR applications the decrease in link loss budget on the OM3/OM4 fibers is 5.9dB. These large decreases in overall link loss budgets makes cleanliness of the fiber optic components and ports a much more critical issue today than in the past. www.commscope.com 3

For example, in the past if the application being deployed was 100BASE-FX and this was running on a 62.5um fiber infrastructure the link loss budget was 11.0dB. If an installer or technician installed patch cords without cleaning them and those cords were contaminated they might have added an additional 2dB 3dB of attenuation to that channel, which would only represent a small percentage,18% - 27% of the overall budget. That channel could still work fine as long as the overall budget and distance were not exceeded. On the other hand, if today a 10GBASE-S application is being deployed over the OM3/OM4 fiber and an installer or technician installs a patch cord without cleaning and that cord is contaminated that same 2dB 3dB of additional attenuation would represent a large percentage, 76.9% - 115% of the overall budget and that link may not operate. The contamination from those dirty patch cords can also lead to permanent damage to the fiber end-faces, which would lead to further down time and replacement costs. Fiber cleaned by installer during installation Dirty patch cord plugged in by end-user after installation Installed fiber cross contaminated by dirty patch cord after installation For this reason, it is imperative that best practices procedures be adopted not only by the installation contractors, but also by the end-user. While business partners/contractors go through training programs that teach them how to properly install, clean and test fiber optic infrastructures, if the end-user does not implement those same policies for the daily maintenance of those systems, the systems can quickly become unusable. This can create a strain on the relationships between end-users, contractors and manufacturers, because, if a system fails who ultimately is to blame? So, to minimize this issue everyone should be responsible for adopting and implementing the following best practices guidelines for installing and maintaining fiber optic infrastructures. Best Practices 1. Always clean every fiber optic component before installing or using it. NEVER assume anything is clean!! This holds true for all pre-term fiber components, i.e. factory made patch cords, fiber modules, crimp on connectors and trunk cables. See CommScope s current Cleaning Procedures guide for proper cleaning techniques. 2. NEVER assume that dust covers or shutters will keep the connectors and ports clean!! 3. Per the IEC 61300-3-35 standard all fiber connectors shall be cleaned and inspected before they are connected into the system. The inspection equipment shall have a means to measure and quantify defects regardless of the method being used. If the inspection of the connector yields results that are below the acceptance criteria outlined in section 5.4 tables 3 6, additional cleaning is required and a final inspection. If final inspection still yields unacceptable criteria the connector is to be replaced. For complete details the standard can be purchased at www.webstore.ansi.org www.commscope.com 4

4. When installing multifiber components, like MPO modules or connectors, in addition to cleaning make sure to inspect the MPO ports inside the module or the MPO connector on the cable with an inspection scope or probe before mating the modules and trunk cables. If contamination is present re-clean and then re-inspect. With a multifiber connector there is a higher potential of contamination. Also with more fibers per connector more channels may be affected, so inspection is critical. 5. For new installations, make sure to test the fiber optic links per the CommScope testing guidelines and make sure to use quality reference grade launch cords that have been cleaned and inspected. 6. When performing routine moves, adds or changes always make sure to clean any patch cords that have been unplugged prior to plugging them back in. Also, clean the connector on the back side of the adapter before putting it back into service. 7. Any unused ports or connectors should be protected with a dust cap or shutter device. These devices will not prevent the connectors or ports from getting contaminated, but will minimize the contamination and prevent the connectors from getting damaged. 8. Before adding additional connection points into an existing link, make sure to verify the extra attenuation can be supported. See CommScope s current version of Performance Specification document for guidance. Maintenance Supplies To properly install and/or maintain a fiber optic infrastructure the following items should be purchased and kept on hand. 1. An inspection kit with proper inspection scope and/or probe along with the proper adapters for each connector style being used, i.e. MPO, LC or ST/SC. The inspection device needs to have the ability to measure and quantify any defects. For example, CommScope s inspection kit, KIT-Clean/Inspect 2. Cassette based cleaner which utilizes an anti-static non-contaminating cloth. For example, USConec Optipop Cassette Cleaner (www.usconec.com) 3. In-bulk-head or in-adapter cleaning tools for the appropriate connector styles being used, i.e. MPO, LC or ST/SC. For example, USConec I.B.C (www.usconec.com) 4. Appropriate cleaning solution for fiber connectors, such as > 92% isopropyl alcohol 5. Optical loss test set to measure end-to-end link loss www.commscope.com 2012 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. 4/12