Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth



Similar documents
Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

17,280 square feet Overview:

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

Facility Assessment for East Main Street, Huntley, IL

Building Condition Assessment Report

PUBLIC RESTROOMS, DESIGN INTENT

VJ ASSOCIATES 1825 K STREET NW, #1100 WASHINGTON, DC TEL: (202) INITIAL PROJECT COST ANALYSIS

Executive Summary. June 2005 Auke Bay Elementary School Condition Survey Report Page 4 of 228

Slavic Village Building Condition Review

ESTIMATE ORIG. ESTIMATE: TOTAL: $204,249 DATE: 01/15/08 DESCRIPTION OF WORK QUANTITY DIVISION TOTAL

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

SPACE TYPE: AUDITORIUM

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY

Architectural Inspection Site Structures

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Historic Preservation Certification Application Part Main Street West South Haven, Vermont NPS Project No

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Mequon - Thiensville School District Long Range Facilities Plan Monthly Project Schedule

Facility Assessment Report, Montgomery Independent School District

Sample Drawing Package for One and Two Family Dwelling Applications

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Mike and Jen Sample 111 Main St. Tabb, VA SPECIFICATION LIST

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Estimator: Miami Estimates Business: (305) Date Entered: 04/30/2008

Milestones Primary. Early Start. Orig Dur. Early Finish. Act ID. Description NOTICE TO PROCEED START CONSTRUCTION

8629 S. Kimbark, Chicago, IL PROJECT SPECIFIC SCOPE:

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Your Company Name. Your Company Address Your City, State, Zip Your Phone Number Your Address. Project Information

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Rehab Inspection Report Page 1

November 3, 2015 Bond and District Additional Assistance Election Information

March 19, Ms. Jean McDonald CAP Management th Street, Suite 1010 Denver, Colorado 80202

All bidders shall indicate in their bid/proposal that this Addendum has been received and considered in their bid proposal.

IMPROVEMENT COST ESTIMATE powered by HomeFixers

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Building Condition Assessment Report

Odd Fellows Hall Warren Avenue, East Providence, RI Historic Structure Assessment. June 2014

July 29, Revise Section 1.1 (BACKGROUND AND CONTEXT) to the following:

Estimating Database Checklist

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

Cascade Remodeling Inc. PO Box Portland, OR Catalyzing Euphoria Phone (503) , FAX (503) CCB # 67007

QUOTATION FOR EXAMPLE BATHROOM RENOVATION

How To Plan A Building

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

Additions and Alterations

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Mark Cramer Inspection Services, Inc.

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

October 5, 2015 Dear Client,

Property Condition Assessment

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

WEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204

Seattle Public Schools Building Excellence IV Projects Under Construction

SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE

3. Tile used in the toilets is generally in good shape, though somewhat dated looking. The floor tile is slippery when wet.

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

BUNKER HILL ELEMENTARY SCHOOL

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.

Residential Decks. Planning and Development Services Department

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

HISTORIC PRESERVATION COMMISSION ADMINISTRATIVE APPROVAL ISSUED JULY - SEPTEMBER 2014 DATE PROJECT ADDRESS PROJECT DESCRIPTION

Insulation R-Value Comparisons

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

CALLOWAY COUNTY SCHOOLS DISTRICT FACILITIES PLAN

Certification: Building Plans Examiner. Exam ID: B3

EnergyMate Homes - Lexington Series

BUILDING PERMIT SPECIFICATIONS

Certificate of Appropriateness Applications

Judy P. Rosenstreich, Senior Policy Advisor

SECTION 3 ONM & J STRUCTURAL ANALYSIS

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Program Demand Cost Model for Alaskan Schools

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

The Brickstone Condominiums At Minington. Transition Punch List 2008

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

A0 SHEET 1 OF LOCUST STREET FRANKFORT, KANSAS FRANKFORT, KANSAS ROOF REPAIR OF THE 400 LOCUST STREET

YOUR COMPANY NAME HERE

March 14, Installation of Bay, Bow and Garden Windows

BROWNSVILLE STRUCTURES STUDY. July Prepared by. LDA ARCHITECTS 33 Terminal Way, Suite 317 Pittsburgh, Pennsylvania

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

2014 British Columbia Building Code Changes

Transcription:

INTRODUCTION: Kronberg Wall Architects is pleased to present the Design Narrative for the Point University Auditorium conversion from the existing warehouse space. General Project Description: This project is the renovation of a portion of the existing warehouse structures at the 2 nd Avenue facility. The overall goal is to limit the amount of work required outside of the core renovation area. This project will also take a very concerted approach to addressing sound protection from the adjacent rail line to limit impact on interior events. An acoustic engineer has not been engaged for this preliminary investigation, so the amount of sound proofing required is subject to change after their review. We do not provide environmental testing, and leave the scope of any asbestos, lead based paint mitigation, etc. to the owner s consultants. Building Area Summary 4 existing buildings: approximate square footage 1. Southern most structure 8,000 SF; wood structure; future scope 2. Main middle structure 14,000 SF; steel prefab structure; current scope intended for theater space 3. Smaller prefab structure north of main - 2,600 SF; steel prefab structure; future scope 4. Structure north and east of main structure along rail 7300 SF; CMU structure w/ steel roof joist; future scope 5. Open air wood structure along rear of property 7900 SF; structure to be removed in current scope 6. Open air steel structure along north property line 4600 SF; portion of roof to be removed per egress requirements; columns and beams to remain in current scope Sitework: We are proposing site improvements at the street front of the building including new curb, tree planting zone, and sidewalk. There are limited site improvements proposed for the existing asphalt area at the South portion of the site. Some demolition of existing roofing and wood frame structures are required at the North and East sides of the site as well. The sidewalk and street trees may need to shift to a phase two scope based upon final budgets, but parking striping will be included regardless. Site Lighting: Exterior lighting will be provided at each building entrance, egress, and surface parking areas. Assume wall packs mounted to the walls for onsite parking. For front façade assume uplight along façade. See also front entry canopy description.

Demolition Narrative: All interior walls within boundaries of scope shall be removed. Rear wood structure along train track side of property shall be demolished and removed. Portion of roofing material along open structure at north side of property shall be removed per egress requirements, however structure shall remain intact. Building Exterior: We plan to upgrade the exterior façade per the initial concept drawings, adding some limited storefront windows at the West elevation. Exterior walls will be framed with metal studs offset from the exterior skin, cavity filled with insulation, and three layers of sheetrock added to the interior face of this wall. Additional items such as resilient channels may also be required by an acoustic engineer. Roofing: The existing roof will be replaced, we are assuming that decking can remain, but may require repair in limited areas. New R-20 insulation will be added above the existing roof deck. A minimum of three layers of ½ cementitious board (Densdeck or similar) will be provided above the insulation for sound protection for a total thickness of 1 ½. A new 60 mil, mechanically fastened TPO roof will be provided above. The additional thickness of roof material will necessitate a rebuild and re-flashing of existing gutters, conductor heads, and downspouts. Assuming new, pre-finished metal gutters, rectangular downspouts, and rectangular scupper heads. Mechanical: An entirely new mechanical system will be needed for the space including round, spiral, lined ductwork. Ductwork in performance space, entry hall, and back of house will be exposed, unpainted. Ductwork in restrooms will be hidden above drop ceiling. Currently considering split system with condensers mounted either at grade at the East side of the building or on the roof. Provide steel cage around each unit if located at grade. Exterior skin: It is the designer s intent to maintain as much of the patina finish existing corrugated metal panel as possible. We will replace existing paneling with a comparably appearing product for the first 10 of the Second Ave façade. Openings along the rear façade where existing fans are to be removed shall be patched and infilled with smooth cementitious panel. See concept elevations for more information.

New Entry Canopy: Provide new, steel frame entry canopy at entry into main lobby as located in site plan. Provide sloped roof and hidden gutter with overflow connecting to pre-finished metal downspout. Clad fascia in prefinished smooth metal panel. Underside of canopy to be clad in spar coated wood slats. Assume outdoor rated can lighting in soffit. Building Interior: Program Summary: Entry Sequence: o Front Corridor: 914 SF o Entry Lobby: 970 SF Restrooms: 863 SF Performance Hall: 8,306 SF Stage: 895 SF Back of House: Total 1,429 SF o Green Room/Meeting Room o Toilet o 4 wide poured concrete ramp to 29 ½ high stage The building will require the addition of (2) hour fire walls as shown on the plan. The unconditioned side of these walls will require a rated, weather resistant sheathing product, Densglass or similar. The floors will be polished concrete. Walls will be sheetrock with rubber base. The ceiling structure will have the existing insulation panels removed. The existing deck will be painted. Tectum panels will be added approximately 75% of the ceiling area. Entry Sequence: The floors will be polished concrete. The walls will be painted sheetrock with rubber base; all new walls will be brought to deck with acoustic batt insulation All storefront doors will be equipped with closers and panic hardware. All doors will be solid core doors equipped with closers and panic hardware Ceilings will be 50% sheetrock, 50% hanging tectum baffles. Lighting will be CFL cans and track lighting

Restrooms: Flooring and Base: Porcelain tile. Allowance per sf of $4-$6 material cost. Wet Walls: 4 high porcelain wall tile wainscot with painted moisture-resistant gypsum wallboard above. All walls around perimeter of restrooms will be brought to deck with 6 light gauge framing and acoustic batt insulation. Ceilings: Acoustic tiles with dropped GWB soffit over lavatory counters. Countertops: Solid surface, 1/2" thickness with edges built up to 1 1/4". Double eased edge detail, typical. Provide 4" backsplash and apron of same material. Mirrors: Wall-mounted float glass with safety backing film, 4-0 high x full width of adjacent countertop. Toilet Partitions: Floor-mounted, overhead braced solid core phenolic resin with fullheight stainless steel brackets. Toilet Accessories: Brushed stainless steel grab bars, tissue dispensers, deck-mounted soap dispensers, and combination paper towel / waste dispensers. Fixtures: Toilets and urinals shall be floor-mounted porcelain flush valve type with automatic flush. Lavatories shall be porcelain under-counter mounted type. See Plumbing portion of narrative for more information. All Common Bathrooms will be exhausted at a rate of 75 CFM / fixture, as required by the International Mechanical Code. Either in-line fans or roof mounted fans will be utilized for the toilet exhaust systems. CFL can lighting and decorative sconce fixture over each lavatory Performance Hall: Floors to be polished concrete with rubber wall base Carpet tile laid down on main aisles appx 20% of floor space 1 ½ & 2 tectum panel mix installed on walls above 8-0 AFF. 2 tectum panels hung along slope of roof for appx 75% of space Painted sheetrock walls with acoustic batt insulation furred out from existing metal walls All perimeter walls of space shall be furred out with 6 stud, filled with 5 acoustic batt insulation and finished with 2 layers of 5/8 GWB. Paint existing exposed steel structure Obtain pricing for the removal of existing columns at C.L. H/8 and H/10 and the running of a new steel box truss from C.L. F to C.L. K. Assumed LED high bay at every 15 O.C., dimmable

Stage: 6 light gauge walls to deck; painted sheetrock; acoustic batt insulation Assuming placeholder curtains along east wall of performance hall/stage for 90 LF at 15 ft high, manually operated, 75% fullness, cotton-lined. Stage to be light gauge framing, ¾ plywood, and hardwood maple with clear polyurethane finish; underside of stage shall be infilled with blown cellulose insulation; maple clad steps and steel handrails on either side as shown in plan. Stage will be 29 ½ AFF of performance hall. ¾ rubber underlayment between plywood and maple flooring. Back of House: Floors to be polished concrete with rubber wall base Ramp up to stage will be poured concrete with painted steel rails Walls to be light gauge with acoustic batt insulation o Green Room: Carpet tile flooring with rubber wall base Drop acoustic ceiling tile and CFL can lighting o Bathroom: Fixtures: Toilets and urinals shall be floor-mounted porcelain flush valve type with automatic flush. Lavatory shall be wall mounted. See Plumbing portion of narrative for more information. CFL can lighting, decorative sconce over lav mirrors: Wall-mounted float glass with safety backing film, 4-0 high x full width of adjacent countertop. Toilet Accessories: Brushed stainless steel grab bars, tissue dispensers, deck-mounted soap dispensers, and combination paper towel / waste dispensers. Signage Provide ADA-compliant interior signage at Common Bathrooms, exits, Stairs, and Service Rooms. Provide signage allowance for exterior building identification signage. The following items will require further coordination: Fire Suppression System Fire Alarm System Communication Systems Security Access System AV Systems Theatrical lighting and systems