PROXIMITY CARD READERS C-10, C-20, C60, C70



Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

P10 - Standalone Access Controller and Reader

GV- RK1352 Card Reader

Digital Keypad Use s Manual

Adaptability to Enhanced Security

Adaptability to Enhanced Security

Model 201 Wiegand Touchpad Reader Installation Guide

AR-721U/721K/661U User s Guide

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

User Manual. Before installation and use, please read the user manual carefully.

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

FSLIMRF

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

TrueAlarm Fire Alarm Systems

USER MANUAL V5.0 ST100

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

ACCESS CONTROL SYSTEM

[FAQ] Troubleshooting Access Control Issues

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ViZion Installation Guide

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

GSM Autodialer Professional GJD700 Speech & Text Autodialer

DT105X / PB105 Series

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

GV-AS/EV Controller. User s Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Business/Home GSM Alarm System. Installation and User Manual

1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document).

QR12 (1.22 ) Diameter Optical Encoder

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Advantium 2 Plus Alarm

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

Absolute Rotary Encoder E6CP

Connection and Configuration of Baudisch SIP unit with Display and RFID Reader Module

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Using the ievo fingerprint reader with Net2

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

GV-AS Controller. Installation Guide

AIS750 Series Alarm Annunciator

User Guide Reflow Toaster Oven Controller

Broadway 3D Security System

HM-W536 Install Guide

AYC-FGx4 Family. Instruction Manual. Backlit, Waterproof Convertible Reader / Controllers. Models: AYC-F54 AYC-F64 AYC-G54 AYC-G64

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Installation manual. Version

TECH SUPPORT NORTH SEMORAN BLVD ORLANDO FL32807

CRYPTOPAY QUICK START GUIDE

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Business/Home. GSM Alarm system

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Model SETR-50 and SETR-51 Trim Tab Control

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Business/Home GSM. Alarm System(III) Installation and Users guide

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

PCS300 Universal IP Reporting Module V1.0

HAI Access Control. The HAI Access Control Card Reader can be used for:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Shunt lock function 3066

STATUS POWER MONITOR ALARM SOS DISARM

Wireless Home Security Alarm System AM 500

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

User Manual. BARKODES BİLGİSAYAR SİSTEMLERİ ARF Panel

HCR3.2/.. Chipcard reader HOTEL SOLUTION

VARIO PROX CARD READER INSTALLATION MANUAL

Wireless Link. Introduction. Setup, Configuration and Connection ENGLISH

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Passive Infrared Motion Detector 5420/90. Installation Instructions

How To Use A Power Supply On A Powerline 2.2 (Ai)

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Transponder reader CÉLIANE TECHNICAL GUIDE

Introducing... The Word's Most Advance. Biometric Time Attendance Door Access Security System

CS TIMECLOCK QUICK START MANUAL

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Installation Manual Siren

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

EMBEDDED ACCESS CONTROL Hardware Installation Guide

FIREDEX Conventional Fire Panels

Transcription:

Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0

CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection table.................................... 5 4. Reader installation................................ 5 5. Keypad output format setup...... 6 ALL rights reserved AAT Holding sp. z o.o. 2

Installation & operation manual 1. GENERAL INFORMATION Series of proximity card readers C-XX includes the following models: C-10 C-20 C-60 C-70 These models differ in housing but are identical in terms of electrical parameters. Varied housing and colors matching the chosen model to the place and manner of assembly and to the interior color. The C-20 model is equipped with a keypad. All models are suitable for indoors and outdoors. Model C-10 Model C-20 Model C-60 Model C-70 ALL rights reserved AAT Holding sp. z o.o. 3

C-10, C-20, C-60, C-70 readers technical data Parameter or function name Model C-10 Model C-20 Model C-60 Model C-70 Electrical parameter - Supply power 9-15 VDC 9-15 VDC 9-15 VDC 9-15 VDC - Current load < 150 ma < 150 ma < 150 ma < 150 ma - Snti-static capability < 15kV < 15kV < 15kV < 15kV Environment parameter - Environment For indoor and outdoor For indoor and outdoor For indoor and outdoor For indoor and outdoor - Working Temperature Od -15 C do 55 C Od -15 C do 55 C Od -15 C do 55 C Od -15 C do 55 C - Relative Humidity 0% - 90% 0% - 90% 0% - 90% 0% - 90% - Dimensions 100 x 70 x 22 mm 115 x 75 x 22 mm 105 x 48 x 20 mm 85 x 85 x 20 mm Communication port For connection with controller Cards - Type UNIQUE (EM) UNIQUE (EM) UNIQUE (EM) UNIQUE (EM) - Format - Frequency 125 khz 125 khz 125 khz 125 khz Keypad No Yes No No Keypad format Not concern 4/8-bits, without buffering Not concern Not concern ALL rights reserved AAT Holding sp. z o.o. 4

Connection table No. Color of wire Function description 1 Red Power 9-15 VDC (+12 nominal) 2 Black GND - ground 3 Green DATA 0 - Wiegand output 4 White DATA 1 - Wiegand output 5 Yellow Buzzer 6 Blue LED Reader installation KZ-1000 controller Relay Buzzer - option Buzzer Alarm LED 12V Lock 12V Relay LED - option 1. Remove the cover from the reader gently undermining its edge at the bottom of the back of the reader (model C-10, 20). In models C-60, 70 unscrew the screw on the bottom edge of the housing. 2. Using the reader module (or the back cover) as a template to designate the holes on the wall. Drill holes and mount plugs. 3. Connect the cable from the reader terminal to the controller according to the above table. In the case of KZ-1000 controller, which has no output to control LED on the reader, you can install an additional relays controlled by the lock output, and the other to the buzzer controlled from the terminals of the alarm siren. 4. Screw the reader module and snap the cover. In models C-60, 70 fasten the screw on the bottom edge of the housing. ALL rights reserved AAT Holding sp. z o.o. 5

The procedure for changing the output format for the keypad - relates to the C-20 model Because different types of controllers require different encoding formats of information sent by the reader keypad, therefore the C-20 model has the ability to change the format of the codes sent to the controller after pressing the selected button. We can choose one of the two most popular formats: 4-bit (for use with KaDe controllers) 8 bit (for use with Kantech and RBH controllers) Currently set format is signaled after power: one beep / one flash a green LED - 4-bit format two beeps / two flashes green LED - 8-bit format Change the current format to another can be performed as follows: turn off the power reader power reader on again within 30 seconds after power, enter code: * # 444888 # The reader will confirm the change in the current format to another available by generating one or two sounds and the same number of flashes the green LED. From then set the format in effect until repeat the above procedure. Sequential change of the two available formats, you can perform any number of times. Code format changes (* # 444888 #) is one and the same. The above procedure applies only to the format of data sent through Wiegand output when you press the selected button on the keypad reader. The output format of data sent through the output after use card remains always the same - 26 bit Wiegand. ALL rights reserved AAT Holding sp. z o.o. 6

NOTES ALL rights reserved AAT Holding sp. z o.o. 7